Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pneumatic Valve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

MISTE flight experiment status

The MISTE flight experiment has made significant scientific and technical progress in preparing for a future microgravity flight. We are collaborating with several theoretical modeling groups that have developed crossover (equation-of-state) models for predicting thermodynamic behavior near the liquid-gas critical point. Several of these models have already been used to test experimental measurements of the heat capacity at constant volume, isothermal susceptibility, and coexistence curve in the crossover region near the 3He liquid-gas critical point. A brief description of these models and a representative fit to experimental data will be presented. In collaboration with Mission Research Corporation, MISTE has been testing a new small pneumatic valve for use at low temperatures. The results of recent successful low temperature actuation tests will also be discussed.

critical phenomena liquid-gas critical point↗

Overview and Assessment of the ESM Pressure Control Performance on Artemis I

The European Service Module propulsion system is a bipropellant hypergolic serial system used to provide translational thrust and attitude control for Orion. To control propellant tank pressure, a bang-bang pressure control system is employed. Each propellant commodity is regulated by a pressure control assembly consisting of two pressurization branches (a primary and redundant pressurization path) where each branch includes 3 valves in series. Regulation is accomplished via flight software control of two downstream solenoid valves triggered off propellant tank ullage pressure. This paper presents an overview of system level challenges which have been overcome to enable a successful Artemis I flight. Principle among the challenges was valve-to-valve pneumatic interactions which drove changes to the control scheme. During the Artemis I mission, the pressure control assembly was able to control tank pressure within allowable tolerances. Comparison between flight data and mathematical models are presented showing excellent agreement. Finally, during flight, a pressure surge was observed during the first regulation cycle when there was propellant in the upstream propellant tank. This was attributed to a gas hammer effect within the pressurization system and was not observable in a 1g environment. This paper also discusses the conclusion that this gas hammer effect is a nominal feature of the system during operations. Assessment of the in-flight performance of the electronic pressure regulation scheme on the European Service Module propulsion system shows the system behaved nominally during the Artemis I mission.

propulsion system↗

Overview and Assessment of the ESM Pressure Control Performance on Artemis I

The European Service Module propulsion system is a bipropellant hypergolic serial system used to provide translational thrust and attitude control for Orion. To control propellant tank pressure, a bang-bang pressure control system is employed. Each propellant commodity is regulated by a pressure control assembly consisting of two pressurization branches (a primary and redundant pressurization path) where each branch includes 3 valves in series. Regulation is accomplished via flight software control of two downstream solenoid valves triggered off propellant tank ullage pressure. This paper presents an overview of system level challenges which have been overcome to enable a successful Artemis I flight. Principle among the challenges was valve-to-valve pneumatic interactions which drove changes to the control scheme. During the Artemis I mission, the pressure control assembly was able to control tank pressure within allowable tolerances. Comparison between flight data and mathematical models are presented showing excellent agreement. Finally, during flight, a pressure surge was observed during the first regulation cycle when there was propellant in the upstream propellant tank. This was attributed to a gas hammer effect within the pressurization system and was not observable in a 1g environment. This paper also discusses the conclusion that this gas hammer effect is a nominal feature of the system during operations. Assessment of the in-flight performance of the electronic pressure regulation scheme on the European Service Module propulsion system shows the system behaved nominally during the Artemis I mission.

propulsion system↗

Independent Orbiter Assessment (IOA): Analysis of the orbiter main propulsion system

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Orbiter Main Propulsion System (MPS) hardware are documented. The Orbiter MPS consists of two subsystems: the Propellant Management Subsystem (PMS) and the Helium Subsystem. The PMS is a system of manifolds, distribution lines and valves by which the liquid propellants pass from the External Tank (ET) to the Space Shuttle Main Engines (SSMEs) and gaseous propellants pass from the SSMEs to the ET. The Helium Subsystem consists of a series of helium supply tanks and their associated regulators, check valves, distribution lines, and control valves. The Helium Subsystem supplies helium that is used within the SSMEs for inflight purges and provides pressure for actuation of SSME valves during emergency pneumatic shutdowns. The balance of the helium is used to provide pressure to operate the pneumatically actuated valves within the PMS. Each component was evaluated and analyzed for possible failure modes and effects. Criticalities were assigned based on the worst possible effect of each failure mode. Of the 690 failure modes analyzed, 349 were determined to be PCIs.

Mcnicoll, W. J.↗

Actuator device schedules rate of valve closure

Prevalve actuator schedules the closure rate of a valve. The actuator is spring loaded to produce a normally open valve and pneumatically powered to close the valve. The closure rate is controlled by means of pneumatic snubber and booster circuitry.

Source record↗

Precision control system for engine fuel

System controls two or more pneumatically operated metering valves from common pneumatic source without interaction between valve controls. Unit affords independent metering of liquid from single source to two concurrent applications. Calibration and testing demonstrate complete absence of interaction between valves and corresponding flow rates.

Hawkins, D. E.↗

Miniature valve accurately controls small volume fluid flow

Hydraulic or pneumatic actuated valve accurately controls small volume flow of liquids or gases by expanding or relaxing an O-ring within an annular flow space. In one application, 2 such valves were used to accurately meter small volumes of helium under a pressure of 1000 psi.

Grunwald, A.↗

Automatic protective vent has fail-safe feature

Delayed vent valve system in a mechanical backing pump in a vacuum system allows the pneumatic foreline valve to seal before the pump vent opens. The system is designed to be fail-safe and operate even though there is loss of electrical power.

Dameron, C. E.↗

Reciprocating engines

An intake valve arrangement for positively controlling the opening and closing of the poppet valve in a hot gas cylinder in a hydrazine powered engine is described. The poppet valve is operated by the piston and gas pressure only. The poppet valve uses a pneumatic spring which holds the poppet valve against the piston while the valve is opened and closed. To accomplish this, a poppet valve is slidably mounted in a pneumatic spring chamber which reaches a pressure approaching the gas supply pressure and, during the opening of the valve, the spring chamber retains enough pressure to hold the poppet valve onto the piston. In addition, the bottom of the poppet valve can have a suction cup type configuration to hold the poppet valve on the piston during the down stroke.

Akkerman, J. W.↗

Low torque three-piece valve seat

Hydroproof, pneumatic proof, cycle, and seat erosion qualification tests on low torque three piece valve sets with various material components for upper seat ring

VALVE↗

Design and Operation of the Planetary In-Situ Capillary Electrophoresis System (PISCES)

The PISCES instrument is a portable, miniature, modular instrument designed to analyze organic molecular signatures of life. PISCES uses microcapillary electrophoresis (μCE) with laser-induced fluorescence detection (LIFD) to analyze fluorescently-labeled analytes prepared on a multi-layer microfluidic chip. As a modular instrument composed of five independently functioning units, each module can be easily detached from the system and used for subsystem testing in different environments, e.g. low temperature. The pneumatic module contains mechanical and electrical components necessary to control pneumatically-actuated valves for on-chip sample processing. A prototype LabVIEW program and two custom printed circuit boards (PCBs) operate the pneumatics module using an Arduino microcontroller, and a tentative design for the module’s housing has been developed. The high-voltage module contains circuitry required to apply varying electrical potentials to the electrophoretic channel of the microdevice. Work is currently being done to design the circuit and PCB for this module in collaboration with our SBIR partners at Los Gatos Research. The optical electronics module contains the spectrometer, laser, and laser power supply. The mounting components for the electronics and housing for the module have been designed, assembled, and tested. The optical module contains optical components to focus the laser to a 20μm spot in the center of the electrophoretic channel.The housing for this module has been designed and assembled with the aligned optical components inside.

Willis, Peter A.↗

Cryogenic Fuel Valve Testbed Development

The goal for this project is to update the cryogenic valve testbed program in LabVIEW to schedule and automate tests and experiments. By using an automated system, tens or hundreds of tests may be performed. This will ensure that accurate data is being collected for testing of the remaining useful life and end of life predictions. From the data obtained, new diagnostic and prognostic methods will be developed to manage or predict potential leaks which may occur in the future. The Cryogenic valve testbed injects controlled faults into the cryogenic fuel valve system in order to accurately determine failure behavior.

Prognostics↗

The novel Mechanical Ventilator Milano for the COVID-19 pandemic

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Furthermore, following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world

60 APPLIED LIFE SCIENCES↗

Design of a Continuous Pellet Fueling System for Wendelstein 7-X

A continuous pellet fueling system (CPFS) is currently being designed at the Oak Ridge National Laboratory (ORNL) for the long pulse operation of the Wendelstein 7-X (W7-X) stellarator. The purpose of the CPFS is to provide deep continuous fueling for feedback-controlled high-density operation and mitigation of predicted hollow density profiles. As described here, the system will provide the capability to inject cylindrical pellets of solid hydrogen or deuterium into the plasma core, with flexibility to vary the pellet size, velocity, and injection frequency. Pellets are nominally of 3 mm in diameter and have a length between 1 and 4 mm. The heart of the CPFS is a vertically oriented, twin-screw extruder, cooled by three Gifford-McMahon cryocoolers in parallel, designed to form a continuous filament of hydrogen or deuterium. The filament width, which determines the pellet length, can be adjusted by means of a variable nozzle driven by a linear actuator at the base of the extruder. Coupled to the nozzle is a solenoid-operated gas gun and cutter assembly. A pneumatic propellant valve pulses a burst of ~60 bar helium to accelerate the cut pellet into W7-X. Three gaps in the guide tubes provide pumping locations to remove the helium propellant before it reaches the plasma. The maximum velocity of the pellet is limited by its ability to survive navigating the guide tube trajectory intact. A microwave cavity located within the guide tube provides the capability to measure the pellet size and velocity. The mechanical and thermal designs of the W7-X extruder, adjustable nozzle, and gun and cutter assembly design are described. A guide tube design and experimental pellet survivability test results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A buckling-sheet ring oscillator for electronics-free, multimodal locomotion

Locomotion of soft robots typically relies on control of multiple inflatable actuators by electronic computers and hard valves. Soft pneumatic oscillators can reduce the demand on controllers by generating complex movements required for locomotion from a single, constant input pressure, but either have been constrained to low rates of flow of air or have required complex fabrication processes. Here, we describe a pneumatic oscillator fabricated from flexible, but inextensible, sheets that provides high rates of airflow for practical locomotion by combining three instabilities: out-of-plane buckling of the sheets, kinking of tubing attached to the sheets, and a system-level instability resulting from connection of an odd number of pneumatic inverters made from these sheets in a loop. This device, which we call a “buckling-sheet ring oscillator” (BRO), directly generates movement from its own interaction with its surroundings and consists only of readily available materials assembled in a simple process—specifically, stacking acetate sheets, nylon film, and double-sided tape, and attaching an elastomeric tube. A device incorporating a BRO is capable of both translational and rotational motion over varied terrain (even without a tether) and can climb upward against gravity and downward against the buoyant force encountered under water.

Robotics↗

Pneumatic shutoff and time-delay valve operates at controlled rate

Shutoff and time delay valve, which incorporates a metering spool that moves at constant velocity under pneumatic pressure and spring compression, increases fluid-flow area at a uniform rate. Diaphragm areas, control cavity volume, and bleed-orifice size may be varied to give any desired combination of time delay and spool travel time.

Horning, J. L.↗

Pioneer Venus Sounder Probe Neutral Gas Mass Spectrometer

A neutral gas mass spectrometer was flown to Venus as part of the Pioneer Venus Multiprobe to measure the composition of its lower atmosphere. The instrument, mounted in the Sounder Probe, was activated after the probe entered the top of the atmosphere, and it obtained data during the descent from 62 km to the surface. Atmospheric gases were sampled through a pair of microleaks, the effluent from which was pumped by a combination of ion and getter pumping. A pneumatically operated valve, controlled by the ambient atmospheric pressure, maintained the ion source pressure at a nearly constant value during descent while the atmospheric pressure varied by three orders of magnitude. A single focusing magnetic sector field mass spectrometer with mass resolution sufficient to reasonably separate argon from C3H4 at 40 amu provided the mass analysis and relative abundance measurements. A microprocessor controlled the operation of the mass spectrometer through a highly efficient peak-tip stepping routine and data compression algorithm that effected a scan of the mass spectrum from 1 to 208 amu in 64 sec while requiring an information rate of only 40 bits/sec to return the data to earth. A subscale height altitude resolution was thus obtained. Weight, size, and power requirements were minimized to be consistent with interplanetary flight contraints.

Hoffman, J. H.↗