Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polymer solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Upper critical solution temperature polymer assemblies via variable temperature liquid phase transmission electron microscopy and liquid resonant soft X-ray scattering

Abstract Here, we study the upper critical solution temperature triggered phase transition of thermally responsive poly(ethylene glycol)- block -poly(ethylene glycol) methyl ether acrylate- co -poly(ethylene glycol) phenyl ether acrylate- block -polystyrene nanoassemblies in isopropanol. To gain mechanistic insight into the organic solution-phase dynamics of the upper critical solution temperature polymer, we leverage variable temperature liquid-cell transmission electron microscopy correlated with variable temperature liquid resonant soft X-ray scattering. Heating above the upper critical solution temperature triggers a reduction in particle size and a morphological transition from a spherical core shell particle with a complex, multiphase core to a micelle with a uniform core and Gaussian polymer chains attached to the surface. These correlated solution phase methods, coupled with mass spectral validation and modeling, provide unique insight into these thermoresponsive materials. Moreover, we detail a generalizable workflow for studying complex, solution-phase nanomaterials via correlative methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of Bottlebrush Polymers in Solution by Neutron Spin Echo Spectroscopy

In this work, we present dynamical and morphological studies on poly(dimethylsiloxane) (PDMS)-based bottlebrush polymers in solution. A combination of small-angle neutron scattering (SANS), pulsed field gradient nuclear magnetic resonance (PFG NMR), and neutron spin echo (NSE) spectroscopy was used to identify structural changes inherent in changing the side-chain length while keeping the backbone constant. These morphological changes are mirrored in the diffusion coefficient determined by PFG NMR, resulting in two coefficients for the elongated and one for the more spherical sample. Faster motions are tracked by NSE using the advantage of time- and length-scale resolutions with the diffusion coefficient predetermined by PFG NMR. Hereby, the sample with short side chains relaxes like wormlike micelles considering the longitudinal direction, whereas the dynamics along the radial extension shows a much stronger Q-dependence as known from any theory. The dynamical behavior within the blob region, covered with the more spherical sample, follows the predictions of Zimm as well as of Zilman and Granek (ZG).

36 MATERIALS SCIENCE↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

Thermally-rearranged polymer blends for gas separation membranes

Polymer blends comprising an ortho-functionalized polyimide homo or copolymer and a polybenzimidazole homo or copolymer, wherein the ortho-functionalized polyimide thermally rearranges to a polymer comprising a phenylene heterocyclic group, such as, polybenzoxazole, polybenzothiazole, polybenzimidazole and/or other heterocyclic structure upon heating. Also disclosed are method of forming a polymer blend comprising dissolving an ortho-functionalized polyimide homo or copolymer and a polybenzimidazole homo or copolymer in a solvent, and optional compatibilizer, to form a polymer solution; contacting a support with the polymer solution; and evaporating the solvent to provide a thin layer comprising the polymer blend on the support. Further, methods of heat treating these polymer blends to thermally rearrange the disclosed polyimides are disclosed, as are the polymer blends prepared thereby. Methods of using these polymer blends to separate gases are also disclosed.

Freeman, Benny D.↗

Ion Exchange Gels Allow Organic Electrochemical Transistor Operation with Hydrophobic Polymers in Aqueous Solution

Conjugated-polymer-based organic electrochemical transistors (OECTs) are being studied for applications ranging from biochemical sensing to neural interfaces. While new polymers that interface digital electronics with the aqueous chemistry of life are being developed, the majority of high-performance organic transistor materials are poor at transporting biologically relevant ions. Here, the operating mode of an organic transistor is changed from that of an electrolyte-gated organic field-effect transistor (EGOFET) to that of an OECT by incorporating an ion exchange gel between the active layer and the aqueous electrolyte. This device works by taking up biologically relevant ions from solution and injecting more hydrophobic ions into the active layer. Using poly[2,5-bis(3-tetradecylthiophen-2-yl) thieno[3,2-b]thiophene] as the active layer and a blend of an ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, and poly(vinylidene fluoride-co-hexafluoropropylene) as the ion exchange gel, four orders of magnitude improvement in device transconductance and a 100-fold increase in kinetics are demonstrated. The ability of the ion-exchange-gel OECT to record biological signals by measuring the action potentials of a Venus flytrap is demonstrated. These results show the possibility of using interface engineering to open up a wider palette of organic semiconductors as OECTs that can be gated by aqueous solutions.

Bischak, Connor G.↗

Manipulation and statistical analysis of the fluid flow of polymer semiconductor solutions during meniscus-guided coating

Recent work in structure–processing relationships of polymer semiconductors have demonstrated the versatility and control of thin-film microstructure offered by meniscusguided coating (MGC) techniques. Here, we analyze the qualitative and quantitative aspects of solution shearing, a model MGC method, using coating blades augmented with arrays of pillars. The pillars induce local regions of high strain rates—both shear and extensional—not otherwise possible with unmodified blades, and we use fluid mechanical simulations to model and study a variety of pillar spacings and densities. We then perform a statistical analysis of 130 simulation variables to find correlations with three dependent variables of interest: thin-film degree of crystallinity and transistor field-effect mobilities for charge-transport parallel (Μ para ) and perpendicular (Μ perp ) to the coating direction. Our study suggests that simple fluid mechanical models can reproduce substantive correlations between the induced fluid flow and important performance metrics, providing a methodology for optimizing blade design.

36 MATERIALS SCIENCE↗

Modeling Solution Drying by Moving a Liquid-Vapor Interface: Method and Applications

A method of simulating the drying process of a soft matter solution with an implicit solvent model by moving the liquid-vapor interface is applied to various solution films and droplets. For a solution of a polymer and nanoparticles, we observe “polymer-on-top” stratification, similar to that found previously with an explicit solvent model. Furthermore, “polymer-on-top” is found even when the nanoparticle size is smaller than the radius of gyration of the polymer chains. For a suspension droplet of a bidisperse mixture of nanoparticles, we show that core-shell clusters of nanoparticles can be obtained via the “small-on-outside” stratification mechanism at fast evaporation rates. “Large-on-outside” stratification and uniform particle distribution are also observed when the evaporation rate is reduced. Polymeric particles with various morphologies, including Janus spheres, core-shell particles, and patchy particles, are produced from drying droplets of polymer solutions by combining fast evaporation with a controlled interaction between the polymers and the liquid-vapor interface. Our results validate the applicability of the moving interface method to a wide range of drying systems. The limitations of the method are pointed out and cautions are provided to potential practitioners on cases where the method might fail.

36 MATERIALS SCIENCE↗

Chemical Amplification of Subthreshold Base Triggers To Drive Sol–Gel Transitions in Polymers

Chemical amplification has been widely applied in applications ranging from stimuli sensing to advanced photoresists, but it is rarely utilized to drive productive mechanical property changes. Here, we demonstrate the use of a base amplifier to drive the gelation of a functional polymer solution, in response to a subthreshold base trigger through a mechanism whereby the trigger drives a dramatic increase in the base concentration driven by base amplification, resulting in complexation of Fe(III) and polymer-bound catechol groups and subsequent gelation of the polymer solution. Furthermore, the concomitant crystallization of dibenzofulvene, which is a byproduct of base amplification, led to significant stiffening of the resultant gel and an unexpected temperature-sensitive change of gel stiffness.

Aromatic compounds↗

Hanging droplets from liquid surfaces

Natural and man-made robotic systems use the interfacial tension between two fluids to support dense objects on liquid surfaces. Here, we show that coacervate-encased droplets of an aqueous polymer solution can be hung from the surface of a less dense aqueous polymer solution using surface tension. The forces acting on and the shapes of the hanging droplets can be controlled. Sacs with homogeneous and heterogeneous surfaces are hung from the surface and, by capillary forces, form well-ordered arrays. Locomotion and rotation can be achieved by embedding magnetic microparticles within the assemblies. Direct contact of the droplet with air enables in situ manipulation and compartmentalized cascading chemical reactions with selective transport. Applications including functional microreactors, motors, and biomimetic robots are evident.

36 MATERIALS SCIENCE↗

Evidence for Photoinduced Polaron Generation in a High Persistence Length Low Bandgap Conjugated Polymer in Solution

Using ultrafast time-resolved infrared (TRIR) spectroscopy, we studied the solution-phase excited-state structural evolution of an indacenodithiophene-co-benzothiadiazole polymer (C8-IDTBT). Following band gap excitation, the TRIR spectra reveal vibrational features that develop within 10 ps and decay over 4 ns. Using pulse radiolysis measurements, charge-modulation spectroscopy, and quantum-chemical calculations, the IR features are assigned to polaron pairs. Interestingly, these features appear on an evolving broad mid-IR electronic absorption background, with kinetics correlating with the formation and decay of the cationradical vibrational bands. A three-state kinetic model successfully reproduces the spectral evolution, revealing that the polaron and exciton populations exist in dynamic equilibrium on picosecond time scales, with time constants for exciton dissociation in the range of 3− 5 ps and polaron-to-exciton reformation between 20 and 100 ps, while both species decay to the ground state on much slower nanosecond time scales (∼1 ns), yielding a remarkably high polaron-generation efficiency, higher than 50%. These findings provide fundamental insights into intramolecular charge photogeneration mechanisms in conjugated polymers, demonstrating efficient bound-polaron formation in isolated polymer chains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Rheology Models on Horizontal Well Polymer Flooding in a Heavy Oil Reservoir on Alaska North Slope: A Simulation Study

Polymer rheology can have either a positive or a negative effect on polymer flooding performance under varied circumstances. Many researchers have studied the effect of polymer rheology in a vertical well, but no field scale studies have been conducted to investigate whether polymer rheology is beneficial to polymer flooding in heavy oil reservoirs developed by horizontal wells. In this paper, we conducted a numerical simulation study to examine the effect of HPAM polymer rheology on a polymer flooding pilot, which is the first-ever project conducted on a heavy oil reservoir from Alaska North Slope (ANS) developed by horizontal wells. Three rheology types were considered in the study including the apparent viscosity measured during coreflooding of using a HPAM polymer, the bulk viscosity measured with a viscometer, and a Newtonian flow model. The results suggest that using the bulk viscosity in simulation underestimates the conformance control and the water-oil-ratio reduction capability of the HPAM polymer solution. When the apparent viscosity is used, the incremental oil and sweep were largely increased, and the optimal recovery period of polymer flooding was extended greatly, especially for the heterogeneous formations. Therefore, the rheology type of polymer plays a significant role in the incremental oil recovery and injection profile of the horizontal well system given the pilot test conditions. This study has provided practical guidance to field operators for the ongoing polymer flooding pilot on ANS and will also provide valuable information for other polymer projects conducted in similar conditions.

Leng, Jianqiao↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-ever Polymer Flood Pilot on Alaska North Slope

Polymer flooding has been validated in the lab and by successful applications in other countries, such as Canada and China, to be an effective EOR technique for heavy oil reservoirs. Currently, polymer flooding is being pilot tested for the first time in the Schrader Bluff viscous oil reservoir at Milne Point field on Alaska North Slope (ANS). One of the major concerns of the operator is the impact of polymer on the oil production system after polymer breakthrough, especially the polymer induced fouling issues in the heat exchanger. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. A unique experimental set-up was indigenously designed and developed to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Under each test condition, the test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution were heated from 77°F to 122°F to mimic field operating conditions. The heating time and fouling amount were recorded for each run. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It has been found that, in general, the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless steel surfaces at all tested skin temperatures (165°F, 250 °F and 350°F), but only higher skin temperatures of 250°F and 350°F could cause polymer induced fouling issues on the copper tube surface and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer induced fouling would not occur and only mineral scale deposited, but above which the polymer would obviously aggravate the fouling issue. The heating efficiency of the tube would be reduced gradually as more fouling material accumulates on its surface. The ESEM results indicate that if polymer precipitated and deposited on the surface, it would bond to the mineral crystals to form a stronger three- dimensional network structure, and that is why the polymer induced fouling was tougher and more difficult to be removed from the tube surface. The XRD analysis results confirm that the presence of polymer in the fluids can enhance the mineral scale propensity. Overall, the study results have provided practical guidance to the field operator for the ongoing polymer flooding pilot test on ANS. This study may also prove to be valuable for other chemical EOR projects around the world.

Alaska North Slope↗

Characterizing the Influence of Organic Polymers on the Specific Reactivity of Particulate Remedial Amendments

Commercially available particulate amendments demonstrate high reactivity for effective treatment of water soluble organic and inorganic contaminants in laboratory studies; however, transport of these particles is constrained in the subsurface. In many field applications, particulate amendments are mixed with organic polymers to enhance mobility for direct push applications or stabilize suspensions for high mass loadings. As such, the interactions between particulate amendments, organic polymers and contaminant species need to be systematically investigated to properly understand mechanistic processes that facilitate predictive performance metrics for specific applications in situ . In this study, batch experiments were conducted to quantify the effects of organic polymers (xanthan gum, guar gum, and sodium alginate), polymer concentration (800 and 4,000 mg/L), and aging (up to 28 days) on chromate treatment rate and capacity by two classes of amendments: reductants [granular zero-valent iron (gZVI), micron-ZVI (mZVI), sulfur modified iron (SMI)], and an adsorbent (bismuth sub-nitrate). When particulate amendments were suspended in polymer solutions, reductants retained between 84–100% of the amendment treatment capacity. Conversely, the adsorbent maintained 63–97% relative treatment capacity of the no-polymer control. Polymer solutions had a more pronounced impact on the rate of chromate removal; first order rates of chemical reduction decreased by as much as 70% and adsorption by up to 81% relative to the no-polymer controls. Polymer–amendment aging experiments also showed decreased Cr(VI) treatment capacity; reductants decreased by as much as 24% and adsorption decreased by as much as 44% after 28 days of incubation. While polymer suspensions are needed to aid the injection of particulate amendments into the subsurface, the results from this study indicate potential losses of treatment capacity and a decrease in the rate of remedial performance due to the physical and chemical interactions between polymer suspensions and reactive particulate amendments. Simple batch systems provide baseline characterization of tripartite interactions for the removal of Cr(VI). Additional work is needed to quantify the full impact of polymers on remedial outcomes under site relevant conditions at field scale.

54 ENVIRONMENTAL SCIENCES↗

Development of 3D Printing Techniques for Solid-State Lithium Batteries: Energy Storage Internship (Final Report)

The goal of this internship was to develop a solid polymer electrolyte with a suitable ionic conductivity and mechanical properties and integrate it with 3D printed cathode for solid state lithium batteries. While liquid electrolytes will have much higher conductivities and therefore higher power densities than solid electrolytes, batteries with such electrolytes suffer from extreme dendritic growth, short-circuiting, and general failure. Typically, batteries prevent this by including a solid yet porous separator somewhere between the anode and cathode to suppress dendritic growth. Solid polymer electrolyte acts as the conductive medium between electrodes as well as the separator that prevents failure from short-circuiting. The specific system explored is a vinyl ethylene carbonate (VEC) and polyethylene glycol diacrylate (PEGDA) mixed polymer solution using both 2,2’-azobis(2-methylpropionitrile) (AIBN) and Irgacure 819, respectively as thermal and photo- initiators. Electrochemical and rheological techniques were used to determine the optimal polymer solution and curing conditions. Through this research, multiple new pathways of exploration have been determined to create a usable solid polymer electrolyte through a combination of varying cure intensities and initiator concentrations.

25 ENERGY STORAGE↗

Tailoring Lifetimes and Properties of Carbodiimide-Fueled Covalently Cross-linked Polymer Networks

The mechanical properties of nonequilibrium polymer hydrogels obtained from the transient cross-linking of polymer chains by a chemical fuel were investigated. Aqueous polymers featuring pendant carboxylic acids were treated with a carbodiimide to give anhydride-cross-linked gels. The anhydrides spontaneously hydrolyze back to the polymer solution, and the cycle can be repeated multiple times. Oscillatory rheology was employed to study the effects of temperature, fuel concentration, chain length, and polymer composition on the storage and loss moduli of the polymeric materials as well as the time taken for the polymers to undergo decross-linking. Regardless of the temperature used, at constant carbodiimide concentration, degelation times are more sensitive to experimental temperature than are the peak storage moduli. Decross-linking times decrease with increasing temperature. As carbodiimide concentration decreases, there is a decrease in moduli and decross-linking times. Within the scope of materials studied, the polymer structure was found to have a relatively small impact on the transient properties of gel networks compared to the fuel concentration and temperature. Furthermore, these findings facilitate the design of tunable on-demand networks and gels.

36 MATERIALS SCIENCE↗

First Ever Polymer Flood Field Pilot to Enhance the Recovery of Heavy Oils on Alaska North Slope – Producer Responses and Operational Lessons Learned

The US Department of Energy and Hilcorp Alaska, LLC are jointly cosponsoring a field pilot project entitled “First Ever Field Pilot on Alaska’s North Slope to Validate the Use of Polymer Floods for Heavy Oil Enhanced Oil Recovery (EOR).” The objective of this pilot is to perform a field experiment to validate the use of an advanced polymer flooding technology to unlock the vast heavy oil resources on Alaska North Slope (ANS). Two pairs of horizontal injection and production wells have been deployed in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field to conduct a polymer flood pilot which was designed to acquire field performance data to optimize polymer flood design in the Schrader Bluff heavy oil reservoirs on ANS. Hydrolyzed polyacrylamide (HPAM) polymer injection started on August 28, 2018 using a custom made polymer mixing and pumping unit. Polymer solution properties such as concentration, viscosity, and filter ratio, have been closely monitored and adjusted as necessary. Operational procedures have been improved to ensure adequate injectivity and polymer propagation through the formation. Oil and water production is tested frequently to monitor water cut performance, and produced water is sampled and analyzed for polymer content. Tracers were pumped pre and post polymer injection startup to compare polymer flood breakthrough timing and sweep efficiency. Polymer injectivity of the horizontal wells drilled in the Schrader Bluff NB sand is found to be sufficient to replace the reservoir production voidage although there were some declines as high viscosity polymer swept the near wellbore region. Production data show significant reduction in water cut and the oil production rate has stabilized. No polymer production has been confirmed from the two horizontal producers after 22 months of polymer injection into the two supporting horizontal injectors. Tracer data show very low sweep efficiencies with waterflood alone, whereas significant improvement has been achieved with polymer flood. Many operational lessons have been learned and improvements have been made regarding polymer mixing, pumping, and onsite quality control, particularly in a challenging Arctic environment. Adequate polymer injection rate can be achieved with diligent monitoring and quality assurance of the properties of the injected polymer solution.

Ning, Samson↗

Polymers in molten inorganic salt hydrate phase change materials: solubility and gelation

Inorganic salt hydrates are of interest as phase change materials (PCMs) for thermal energy storage because of their unique properties, such as high latent heats of fusion, moderate melting temperatures, high volumetric energy storage densities, and enhanced thermal conductivities compared to their organic counterparts. Because of the low viscosities of molten salt hydrates, the leakage and settling of solids can easily occur during their application. Polymers are promising candidates for preventing these issues. In addition, the non-flammability, non-volatility, and nontoxicity of many molten salt hydrates make them attractive options as “green” solvents for polymers. However, solutions of polymers in molten salt hydrates have rarely been studied and are poorly understood. The highly ionic environments in these materials created due to a scarcity of hydration water for ions leads to strong ionic interactions, with ramifications for polymer solubility and chain expansion. This Perspective article aims to focus on polymer solutions and gels in inorganic salt hydrates by comparing these systems with existing knowledge of polymers in traditional ionic liquids and aqueous salt solutions. To provide insight into the states of ions and water in molten salt hydrates and the degree of hydration of polymers in these solvents, infrared spectroscopy experiments have been performed, and the data are correlated with the temperature-responsive gelation of poly(vinyl alcohol), one candidate material currently used for the shape stabilization of inorganic PCMs. Finally, the thermal properties of inorganic salt hydrates and ionic liquids are compared and strategies for the shape stabilization of inorganic salt hydrates using polymers, through the formation of physical gels, are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗