Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polypropylene”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Genesis Non-flight Implant Sample Archive

Introduction: For the past 20 years the Genesis science community has been analyzing solar wind captured in sample collectors now curated at Johnson Space Center (JSC). Non-flown flight like collector materials (non-flight) considered reference material was always allocated by the JSC Genesis team for testing experimental procedures. However, to expedite Genesis science, distribution of non-flown reference materials were also provided by, D. S. Burnett (Genesis PI, Caltech) and A. J. G. Jurewicz (ASU) who were funded to aid all Genesis PIs by providing engineering test materials archived at Caltech pre-flight as well as ion implants into these materials [1]. Implanted materials (non-flight reference, flight-like semiconductor materials, and NIST SRM glass) received from the Caltech collection during a pilot project are being used to develop an accession procedure for the purpose of making these materials available to researchers in the future. These implant samples are important because they can be utilized as measurement standards [2]. This is a work in progress and this work reports progress in documentation and imaging. The pilot program received 63 implanted reference materials with known implanted ions. Genesis Non-Flight Database: The existing non-flight material database was modified to allow for the description of implant sessions and to allow correlation of the implant information to individual specimens. An implant session has three main components: a known ion, a known dose (ion/cm2), and a known energy (keV). Procedure: Laboratory Procedure. Upon receiving non-flight analytical standards (independently calibrated implants), or implant samples (nominally calibrated implants), they will be imaged in their current containers to capture any information written before being brought into the Genesis Sample Laboratory. Documentation is provided by the donor and used for correlating the data between the implant sessions and implant samples. This information is not verified by Genesis Curation. The microscope used to image samples in the laboratory has an automated stage with a stainless-steel plate to hold samples and a camera that utilizes the software Surveyor to take photomosaic images of the implant samples. The camera attached to the microscope is a QICAM High Performance IEEE 1394 FireWire Digital CCD Camera. This setup, shown in Fig. 1, allows for photomosaics of small-scale samples with a 10x objective or 25x objective. Examples of images taken with this microscope setup are shown in Fig.2 and Fig. 3. After imaging, samples get stored in a clean fluoroware container or polypropylene vial depending on sample size for long term storage. Database Procedure. The Genesis Non-Flight Database currently allows for the addition of implant sessions. The required fields for adding an implant session are the implant session ion, the implant session dose, and the implant session energy. There are also fields for the date and vendor of the sessions as well as a field for if the session was calibrated or not. Once an implant session has been inserted into the database, additional documentation from the session can be attached. The database will automatically assign an Implant Session Number. After inserting an implant session, the implanted samples can be inserted. The fields required for an implant sample are the material of the sample and the size of the sample. The Generic name for the implant sample with be automatically generated by the database once it has been inserted. Implant sample numbers begin with 3X to distinguish from flown Genesis sample numbers. There are also fields for processors to add the location (room, cabinet, tray) and container type (fluoroware, polypropylene vial). Once an implant session and an associated sample(s) have been inserted into the database the sample can be then tied to all associated implant sessions. An implant sample can be tied to multiple implant sessions. Future work: For curation, future work consists of creating an online catalogue for implant samples as well as updating the database with more samples as we receive them. For the scientific community these implant samples have many potential uses. For Genesis research, they are directly applicable for testing and, in some cases, as analytical standards. For non-Genesis research, implants (especially calibrated implants) could be used for calibrating other, unique planetary materials [1].

C D Calva↗

Novel dielectric reduces corona breakdown in ac capacitors

Dielectric system was developed which consists of two layers of 25-gage paper separated by one layer of 50-gage polypropylene to reduce corona breakdown in ac capacitors. System can be used in any alternating current application where constant voltage does not exceed 400 V rms. With a little research it could probably be increased to 700 to 800 V rms.

Loehner, J. L.↗

A rocket borne instrument for the study of soft X-ray emission from cosmic X-ray sources

Details about a rocket-borne instrument designed for studying the various characteristics of soft X-ray emission from cosmic X-ray sources in the energy range of 0.2 to 3 keV are presented. The X-ray detector consists of a bank of four multilayer, wall-less proportional counters, each with an area of 400 sq cm. The detectors are covered by windows of 1.4-micron polypropylene and are maintained at a constant pressure in flight using a gas control system. Two of the detectors are equipped with 0.4- by 10-deg collimators for mapping the spatial distribution of soft X-rays from extended X-ray sources. A pair of balanced filters consisting of oxygen and CF4 are used for detecting oxygen emission lines.

Agrawal, P. C.↗

New separators for nickel-zinc batteries

Flexible separators consisting of a substrate coated with a mixture of a polymer and organic and inorganic additives were cycle tested in nickel-zinc cells. By substituting a rubber-based resin for polyphenylene oxide in the standard inorganic-organic separator, major improvements in both cell life and flexibility were made. Substituting newsprint for asbestos as the substrate shows promise for use on the zinc electrode and reduces separator cost. The importance of ample electrolyte in the cells was noted. Cycle lives and the characteristics of these flexible, low-cost separators were compared with those of a standard microporous polypropylene separator.

Sheibley, D. W.↗

Fabrication and testing of large size nickel-zinc cells

The design and construction of nickel zinc cells, containing sintered nickel electrodes and asbestos coated inorganic separator materials, were outlined. Negative electrodes were prepared by a dry pressing process while various inter-separators were utilized on the positive electrodes, consisting of non-woven nylon, non-woven polypropylene, and asbestos.

Klein, M.↗

Measurements of the frequency spectrum of transition radiation

We report a measurement of the frequency spectrum of X-ray transition radiation. X rays were generated by electrons of 5 and 9 GeV in radiators of multiple polypropylene foils, and detected in the range 4 to 30 keV with a calibrated single-crystal Bragg spectrometer. The experimental results closely reproduce the features of the theoretically predicted spectrum. In particular, the pronounced interference pattern of multifoil radiators and the expected hardening of the radiation with increasing foil thickness are clearly observed. The overall intensity of the radiation is somewhat lower than predicted by calculations.

Cherry, M. L.↗

A portable hypergolic oxidizer vapor sensor for NASA's Space Shuttle program

The design and performance characteristics of an electrochemical NO2 sensor selected by NASA for the space shuttle program is described. The instrument consists of a sample pump, an electrochemical cell, and control and display electronics. The pump pushes the sample through the electrochemical cell where the vapors are analyzed and an output proportional to the NO2 concentration is produced. The output is displayed on a panel meter, and is also available at a recorder jack. The electrochemical cell is made up of a polypropylene chamber covered with teflon membrane faceplates. Plantinum electrodes are bonded to the faceplates, and the sensing and counter electrodes are potentiostatically controlled at -200 mV with respect to the reference electrode. The cell is filled with electrolyte, consisting of 13.5 cc of 23% solution of KOH.

Helms, W. R.↗

Energy storage cycling tests

Results of cyclic tests on seven 3-cell 100 A-H nickel cadmium batteries on 1.5 hr cycles are presented. The failure of the nylon and polypropylene separators was not analyzed.

Bragg, B. J.↗

Lithium cell tests at Marshall Space Flight Center

Three 18 AH Li-CF batteries with a polypropylene separator and using dimethyl sulfite in Li as F6 for the electrolyte will be placed in each shuttle solid rocket booster for range safety and frustrum location aid. Mechanical vibration, acceleration, random and design vibration, and discharge evaluation tests are discussed.

Paschal, L. E.↗

Cell design and manufacturing changes during the past decade

Eight of the most important changes that occurred in the GE 12 AH cell over the past ten years, which are currently being used are evaluated, and a systematic approach to compare their relative merits is presented. Typical positive thickness, typical negative thickness, positive loading, negative loading, final KOH quantity, and precharge as adjustment are shown for the control cell, and the following variables: Teflon treatment; silver treatment; light loading; no PQ treatment; polypropylene separator; the A.K. 1968 plate design no PQ, old elec process, no decarb process and the A.K. 1968 plate design, no PQ, present aerospace processes. The acceptance test cell voltage and cell pressure performance and capacity test results are included.

Baer, D. A.↗

Toxicity of pyrolysis gases from some synthetic polymers

Nine samples of synthetic polymers were evaluated for toxicity of pyrolysis gases, using the toxicity screening test method developed at the University of San Francisco. The materials were polyoxymethylene, polyethylene (five samples), polypropylene, polymethyl methacrylate, and polystyrene. Of the five polyethylene samples, three contained known levels of chlorine. These test results were combined with earlier data to provide a comparison of 25 samples of synthetic polymers. Polyoxymethylene appeared to exhibit the greatest toxicity, and polystyrene the least toxicity, under these particular test conditions

Hilado, C. J.↗

The application of a drift multiwire proportional counter to the imaging of low energy X-rays

A 75 mm x 75 mm multiwire proportional counter (MWPC) with a 1 micron polypropylene window has been built to map low energy X-rays. The MWPC is constructed with a large drift region which allows us to use the center-of-gravity technique to improve the counter's efficiency and position resolution. Using 330 torr of propane as the gas fill and an anode plane composed of 20 micron diameter Au-plated tungsten wire spaced 1 mm apart, a position resolution of better than 240 microns (FWHM) in two orthogonal directions at an X-ray energy of 0.94 keV has been achieved.

Ku, W. H.-M.↗