Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pool Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration

Heat transfer enhancement techniques have been adapted on the shell side to improve the overall performance of the flooded evaporators, such as finned tubes. In recent years, it has been demonstrated that the metal foam structure can offer enhanced heat transfer performance under pool boiling conditions. However, there are not much research in the open literature that examine the feasibility of metal foam embedded tubes in horizontal tube bundle configurations. Therefore, this paper proposed a novel metal foam embedded tube (i.e., foam embedded outside the tube) to improve the heat transfer behavior of flooded evaporators. Further, the experiments were performed on a horizontal tube bundle with a staggered arrangement. Moreover, the performance of low global warming potential (GWP) refrigerants (R-1234yf and R-1234ze(E)) is compared against R-134a for both plain tubes and metal foam tubes with porosities of 81%, 75%, and 62%. The results showed that a metal foam tube with a porosity of 62% showed a maximum heat transfer coefficient (HTC) enhancement of 291% compared to the plain tube. As compared with R-134a, the HTCs of R-1234yf and R-1234ze(E) are nearly 10% higher and 5% lower, respectively.

42 ENGINEERING↗

Three‐Tier Hierarchical Structures for Extreme Pool Boiling Heat Transfer Performance

Abstract Boiling is an effective energy‐transfer process with substantial utility in energy applications. Boiling performance is described mainly by the heat‐transfer coefficient (HTC) and critical heat flux (CHF). Recent efforts for the simultaneous enhancement of HTC and CHF have been limited by an intrinsic trade‐off between them—HTC enhancement requires high nucleation‐site density, which can increase bubble coalescence resulting in limited CHF enhancement. In this work, this trade‐off is overcome by designing three‐tier hierarchical structures. The bubble coalescence is minimized to enhance the CHF by defining nucleation sites with microcavities interspersed within hemi‐wicking structures. Meanwhile, the reduced nucleation‐site density is compensated for by incorporating nanostructures that promote evaporation for HTC enhancement. The hierarchical structures demonstrate the simultaneous enhancement of HTC and CHF up to 389% and 138%, respectively, compared to a smooth surface. This extreme boiling performance can lead to significant energy savings in a variety of boiling applications.

36 MATERIALS SCIENCE↗

Mitigation of Boiling-Induced Thermal Degradation Using Microporous Nickel Inverse Opals Structures

Engineered microporous structures have received much attention in high-heat-flux electronics cooling due to their high thermal conductivity and permeability, and large surface area for heat transfer, but are susceptible to boiling-induced thermal degradation. Here, this study investigates the efficacy of nickel inverse opals (NiIOs) in mitigating structural degradation caused by corrosion-assisted erosion during pool boiling with water as the working fluid. First, we compared the reliability of NiIOs to copper inverse opals (CuIOs) for a 3-day pool boiling test at constant heat flux. The NiIOs demonstrated superior resistance to thermal degradation due to their inherent corrosion resistance and mechanical strength. Subsequently, we conducted a more controlled experiment to show the effect of heat flux on the degradation of the NiIOs while excluding the effect of temperature variations. Pool boiling tests of 20-μm-thickness NiIOs covering an area of ∼11 × 11 mm 2 with a 2.5 × 2.5 mm 2 heater at the center were conducted at heat flux levels of 20%, 40%, and 60% of the critical heat flux (CHF) for 3 days. The NiIOs subjected to heat flux levels of 20% and 40% CHF showed minimal degradation, while the sample subjected to 60% CHF showed erosion on the top surface due to higher bubble formation and departure rate. These results show the potential of NiIOs as a promising solution for long-term thermal management in high-power electronic devices, although design considerations for maximum allowable heat flux are necessary for reliable operation.

36 MATERIALS SCIENCE↗

Microchannel Geometries for Improved Heat Transfer with Low-GWP refrigerants

Due to efforts aimed at decarbonizing industries, the use of refrigerants with low global warming potential (GWP) is highly recommended in the air-conditioning and refrigeration sectors. Despite possessing low-GWP values of less than 150, hydrofluoroolefins (HFO) exhibit relatively lower heat transfer performance compared to conventional hydrofluorocarbons (HFC) under certain operating conditions. In contrast to HFCs, there is a high demand for enhanced surfaces to meet the needs of heat transfer systems utilizing low GWP refrigerants. Accordingly, this study analyzes the pool boiling performance of low-GWP refrigerants in microchannel geometries. The experiments were carried out at various heat flux levels on both smooth and enhanced surfaces. The pool boiling behavior of low-GWP refrigerant R1234yf was compared to that of R-134a refrigerant in terms of heat transfer coefficient and wall superheat. The results indicate that the heat transfer coefficients of the enhanced surface are significantly higher than those of the smooth surface. Furthermore, the microchannel geometry demonstrated a lower wall superheat compared to the smooth surface. Additionally, a visualization study was performed using a high-speed camera to understand the pool boiling mechanism of low-GWP refrigerants on both smooth and enhanced surfaces.

Murugan, Muneeshwaran↗

Porous mesh manifold for enhanced boiling performance

High-performance electronics are continuously demanding cooling of higher heat fluxes. Phase-change cooling, including pool boiling, is a useful approach to address this challenge; however, competition between liquid and vapor flows generally limit the heat fluxes that can be dissipated. A range of strategies to control these flows have been investigated previously, including capillary guides. Here a manifold structure formed from a metallic mesh is investigated to control the disposition of liquid and vapor phases above a pool fed boiling surface enhanced with porous structures. Copper mesh forms defined liquid flow paths, using capillary action to guide and distribute liquid evenly over the heated surface, along with open channels to facilitate vapor escape. The mesh provides a novel structure for liquid guidance that imposes low resistance to liquid flow while occluding a minimal area of heated surface underneath. The manifold performance is characterized in boiling fed by a pool of water above a laser-textured aluminum nitride heat dissipation surface with pin–fin structures having heights of 110 µm and spacing of 30 µm with a heated area of 5 mm x 5 mm. A maximum heat flux of 490 W/cm 2 is reached with the manifold in the pool fed configuration, representing an increase of more than 65% over the porous pin fin surface alone. The maximum stable superheat observed for the manifold of 36K is 14K higher than that for the porous surface without the manifold. The factors limiting performance of the manifold are analyzed. High superheat is attributed to partial flooding of the boiling surface as suggested by the reduction in superheat using external suction. Similar systems and structures for enhanced two-phase cooling are compared.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Safety [Vol. 16, No. 1, January-February 1975]

Nuclear Safety covers significant developments in the field of nuclear safety. The scope is limited to topics relevant to the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, safety considerations in regard to the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 AEC Working Paper on Population Density Around Nuclear Power-Plant Sites Adapted by J. Ft. Buchanan, 8 Water-Reactor Safety-Research Information Meeting by Wm. B. Cottrell, D. O. Hobson, and G. D. Whitman; ACCIDENT ANALYSIS: 29 Burnout in Boiling Heat Transfer. Part I: Pool-Boiling Systems by A. E. Bergles; PLANT SAFETY FEATURES: 43 Radionuclide Behavior During Normal Operation of Liquid-Metal-Cooled Fast Breeder Reactors. Part 1: Production by C. A. Erdman and A. B. Reynolds; CONSEQUENCES OF EFFLUENT RELEASE: 60 The Control, Monitoring, and Reporting of Radioactivity in Effluents. Part 1: AEC-Owned Facilities by M. B. Biles and F. E. Coffman, 71 The Control, Monitoring, and Reporting of Radioactivity in Effluents. Part 2: AEC-Licensed Facilities by L. B. Higginbotham and J. T. Collins; OPERATING EXPERIENCES: 76 Incident at the Lucens Reactor by J. M. Miller, 79 IAEA Symposium on Experience from Operating and Fueling of Nuclear Power Reactors by William A. Pryor, 87 Recent Occurrences at Nuclear Reactors and Their Causes Compiled by William R. Casto, 98 Summary of Operating U. S. Power Reactors as of Nov. 1. 1974, 101 Selected Safety-Related Occurrences Reported in September and October 1974 Compiled by William R. Casto; CURRENT EVENTS: 104 General Administrative Activities Compiled by Wm. B. Cottrell, 110 Action on Power-Reactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B. Cottrell, 119 Action on Nonreactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B. Cottrell, 121 Proposed Rule Changes as of Oct. 31, 1974; MISCELLANY: 97 ASTM—Euratom Symposium on Radiation Dosimetry: Developments and Standardization (Announcement), 118 Workshops on In-Pile Filter Testing (Announcement), 119 IAEA Symposium on Radiological Impacts from Releases from Nuclear Facilities into Aquatic Environments (Announcement).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental investigation on nucleate boiling heat transfer of low GWP refrigerants over metal-foam enhanced tube bundles

The objective of this work is to develop an enhanced tube bundle to improve the nucleate boiling heat transfer for the application of flooded evaporators. The enhanced tube bundle was made by deploying metal foam around the outer surface of aluminum tubes, which provide higher heat transfer area and nucleation site density. The pool boiling experiments for horizontal tube bundles were conducted in a pressure vessel at difference heat fluxes. The heat transfer performance of bare aluminum tube bundle was compared against the metal-foam enhanced tube bundle using low GWP refrigerant, R-1234yf. The experimental results showed that the heat transfer coefficient of the metal-foam enhanced tube bundle was at least two times higher than that of the bare tube bundle, and the enhancement ratio depended on the heat flux condition.

Yang, Cheng-Min↗

Microbubble dynamics and heat transfer in boiling droplets

Dissipating large heat fluxes from a surface is critically important in numerous industrial and natural applications. Boiling based spray cooling and surface texturing are two of the most promising methods being investigated to address this problem. Although our understanding on these topics has significantly improved over past decades, critical gaps remain in the knowledgebase stymieing the realization of their full potential. As an example, while bubble growth in pool boiling have been investigated in detail, comparatively little is known about how the bubbles evolve inside boiling drops. In the present work, we have investigated for the first time, the microbubble dynamics inside water droplets boiling on superhydrophilic textured substrates using high-speed X-ray phase contrast imaging (XRPCI). Our observations show that the transient bubble density variation follows similar characteristics irrespective of the texture spacing at a given surface temperature. For an example microstructure, we found that the number of discrete bubbles on the surface decreases as temperature is increased although their growth rate increases. Here, we observe that bubble growth is highly non-uniform during the lifetime of a drop on the surface. Initially, bubbles grow under diffusion-limited regime, but at later times they grow as ~t 1.45 due to combined effects of coalescence and evaporation. In some conditions, we found that bubbles shrink dramatically af- ter the initial growth spurt presumably due to severe quenching of the surface, and migration of bubbles on the surface. Using the bubble sizes, for the first time we analyzed the heat flux removed by a single bubble and also by all the bubbles at a given time. We find that the highest dissipation through latent- heat component (~600 W/cm 2 ) occurs just in the beginning and thereafter it decreases. We expect that our findings and the analysis would guide further work on the topic and will aid in the overarching goal of engineering surfaces that are more efficient in boiling heat transfer.

42 ENGINEERING↗

Falling-film thermosyphons: Application to water harvesting from humid gas streams

Water harvesting from humid gas streams is central to fresh-water production, desalination, and particulate removal from combustion gas streams. Two-phase thermosyphons are well suited for these applications due to their very low thermal resistance, but have several operating limits at the high heat flows required for such applications. This work introduces the falling-film thermosyphon for large-scale condensation applications. Working fluid is pumped to the top of the evaporator to provide the evaporating liquid film on the inner tube wall, rather than by vapor condensation. The flooding, dry-out and pool-boiling limits are eliminated, resulting in significantly higher maximum heat fluxes for the same physical evaporator size. Furthermore, the condenser no longer needs to be located vertically above the evaporator, which allows for a standard steam condenser to be used. A model for the condensation process in humid air was developed that estimates the fluid and heat transfer and is confirmed experimentally. Further benefits include the use of a high-thermal-conductivity polymer material for the evaporator section to minimize corrosion, and the ability to impose a temperature boundary condition on the evaporator, which is made possible due to the elimination of a liquid pool.

42 ENGINEERING↗

A unifying criterion of the boiling crisis

Abstract We reveal and justify, both theoretically and experimentally, the existence of a unifying criterion of the boiling crisis. This criterion emerges from an instability in the near-wall interactions of bubbles, which can be described as a percolation process driven by three fundamental boiling parameters: nucleation site density, average bubble footprint radius and product of average bubble growth time and detachment frequency. Our analysis suggests that the boiling crisis occurs on a well-defined critical surface in the multidimensional space of these parameters. Our experiments confirm the existence of this unifying criterion for a wide variety of boiling surface geometries and textures, two boiling regimes (pool and flow boiling) and two fluids (water and liquid nitrogen). This criterion constitutes a simple mechanistic rule to predict the boiling crisis, also providing a guiding principle for designing boiling surfaces that would maximize the nucleate boiling performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calculation of Spent Fuel Pool Time-to-Boil using Polaris/ORIGAMI [Slides]

The goal of this experiment was to calculate time-to-boil (TTB) for a Spent Fuel Pool (SFP). TTB is important for SFP management that represents the amount of time available to address loss of forced cooling. Researchers calculated and compared TTB for two cases using SCALE: SFP containing representative LEU fuel (≤ 5 wt %) and SFP containing representative LEU+ fuel (5 – 8 wt %). There were approximately 2300 fuel assemblies in the SFP for each case. Researchers concluded that the impact of LEU+ core on time-to-boil is very small. At such low cooling times, the impact of increased decay heat is not significant. Decay heat of SFP assemblies is small compared to discharge core decay heat.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗