Search NASA⌕ Search

SEARCH · Search NASA

Results for “Portable mass spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Smaller, Lighter Magnetic Sector For Mass Spectrometer

Miniature, lightweight focal-plane magnetic sector of mass spectrometer (Mattauch-Herzog type) developed. Magnetic sector integral part of portable gas-chromatograph/mass spectrometer (GC/MS). Focal plane covers nominal range of 40 to 240 atomic mass units for 1-keV ion energy. System used for analyzing pollutants in field environments.

Sinha, Mahadeva P.↗

Pressure-Sensitive Adhesive Combined with Paper Spray Mass Spectrometry for Low-Cost Collection and Analysis of Drug Residues

Illicit drug use causes over half a million deaths worldwide every year. Drugs of abuse are commonly smuggled through customs and border checkpoints and, increasingly, through parcel delivery services. Improved methods for detection of trace drug residues from surfaces are needed. Such methods should be robust, fieldable, sensitive, and capable of detecting a wide range of drugs. In this work, commercially produced paper with a pressure-sensitive adhesive coating was utilized for the collection and analysis of trace drug residues by paper spray mass spectrometry (MS). This modified substrate was used to combine sample collection of drug residues from surfaces with rapid detection using a single paper spray ticket. The all-in-one ticket was used to probe different surfaces commonly encountered in forensic work including clothing, cardboard, glass, concrete, asphalt, and aluminum. A total of 10 drugs (acetyl fentanyl, fentanyl, clonazolam, cocaine, heroin, ketamine, methamphetamine, methylone, U-47700, and XLR-11) were evaluated and found to be detectable in the picogram range using a benchtop mass spectrometer and in the low nanogram range using a portable ion trap MS. Finally, the novel approach demonstrates a simple yet effective sampling strategy, allowing for rapid identification from difficult surfaces via paper spray mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Portable Universal Hazardous Gas Detector

Experimental work on the Miniature Mass Spectrometer (MMS) at JPL has resulted in a 'table top' configuration with a CCD detector that has demonstrated a detection limit of 50 parts per billion. The CCD detector operates at ambient temperature. Intelligent Ion, Inc., a commercial instrument developer, has taken out a license on the JPL technology and has built a prototype using a Faraday Cup Array detector as a placeholder detector. The prototype instrument was tested at Kennedy Space Center and demonstrated detection limits in the parts per million range. The test results are presented as well as detailed photographs of the prototype instrument. A presentation of the MMS was made to an expert review panel for 'On-Board Environmental Monitoring Systems for the International Space Station (ISS).' The scores obtained by the MMS system are presented. The prototype instrument will be retro fitted with a CCD array detector in August 2004 and will again be tested at KSC. The instrument is expected to show a detection level for hydrazines of 10 ppb and a detection level for solvents below 10 ppb.The expectations are based on raw data from the first batch of CCD's that was tested.

spacecraft fuels↗

Advances in space technology: the NSBRI Technology Development Team

As evidenced from Mir and other long-duration space missions, the space environment can cause significant alterations in the human physiology that could prove dangerous for astronauts. The NASA programme to develop countermeasures for these deleterious human health effects is being carried out by the National Space Biomedical Research Institute (NSBRI). The NSBRI has 12 research teams, ten of which are primarily physiology based, one addresses on-board medical care, and the twelfth focuses on technology development in support of the other research teams. This Technology Development (TD) Team initially supported four instrumentation developments: (1) an advanced, multiple projection, dual energy X ray absorptiometry (AMPDXA) scanning system: (2) a portable neutron spectrometer; (3) a miniature time-of-flight mass spectrometer: and (4) a cardiovascular identification system. Technical highlights of the original projects are presented along with an introduction to the five new TD Team projects being funded by the NSBRI.

Non-NASA Center↗

A miniature mass spectrometer for hydrazine detection

A Miniature Mass Spectrometer (MMS) with a focal plane (Mattauch-Herzog) geometry has been developed at the Jet Propulsion Laboratory. The MMS has the potential to meet the NASA requirements of 10 parts per billion sensitivity for Hydrazine detection, as well as the requirements for instant response, portability, and low maintenance.

MMS Miniature Mass Spectrometer hydrazine detectio↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Air Monitoring for Hazardous Gas Detection

The Hazardous Gas Detection Lab is involved in the design and development of instrumentation that can detect and quantify various hazardous gases. Traditionally these systems are designed for leak detection of the cryogenic gases used for the propulsion of the Shuttle and other vehicles. Mass spectrometers are the basis of these systems, which provide excellent quantitation, sensitivity, selectivity, response and limits of detection. Unfortunately, these systems are large, heavy and expensive. This feature limits the ability to perform gas analysis in certain applications. Smaller and lighter mass spectrometer systems could be used in many more applications primarily due to the portability of the system. Such applications would include air analysis in confined spaces, in-situ environmental analysis and emergency response. In general, system cost is lowered as size is reduced. With a low cost air analysis system, several systems could be utilized for monitoring large areas. These networked systems could be deployed at job-sites for worker safety, throughout a community for pollution warnings, or dispersed in a battlefield for early warning of chemical or biological threats. Presented will be information on the first prototype of this type of system. Included will be field trial data, with this prototype performing air analysis autonomously from an aircraft.

Arkin, C. Richard↗

Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC). Vista Photonics developed the core technology and built the sensor. Nanoracks designed, constructed the enclosure, interfaces, and battery power management circuitry, integrated all subsystems into the enclosure, and then managed the certification tests, documentation and manifesting. The unit was calibrated in the JSC Toxicology Laboratory. The Multi-Gas Monitor is manifested to fly as a technology demonstration to the ISS in November 2013 and will operate for at least 6 months with data sent to the ground for evaluation. The primary goal is to demonstrate long term interference free operation in the real spacecraft environment.

Pilgrim, Jeffrey S.↗

GC/MS Gas Separator Operates At Lower Temperatures

Experiments show palladium/silver tube used to separate hydrogen carrier gas from gases being analyzed in gas-chromatography/mass-spectrometry (GC/MS) system functions satisfactorily at temperatures as low as 70 to 100 degrees C. Less power consumed, and catalytic hydrogenation of compounds being analyzed diminished. Because separation efficiency high even at lower temperatures, gas load on vacuum pump of mass spectrometer kept low, permitting use of smaller pump. These features facilitate development of relatively small, lightweight, portable GC/MS system for such uses as measuring concentrations of pollutants in field.

Sinha, Mahadeva P.↗

Virtual Slit Cycloidal Mass Spectrometry for Isotopic Measurements of Actinide Particles

The Virtual Slit Cycloidal Mass Spectrometer is a unique instrument for analysis of particles with mass spectrometry. It combines the unique properties of the cycloidal mass analyzer with capacitive transimpedance amplifier array detectors to make a portable instrument potentially capable of high sensitivity measurements on single particles, including high precision isotope ratios.

47 OTHER INSTRUMENTATION↗

Interfacing Atmospheric Flow Tube to Ion Mobility Spectrometry: FY 2021 Final Report

An atmospheric flow tube (AFT) provides extended ion-molecule reaction times of 2-3 seconds compared to milliseconds in typical mass spectrometers. This results in several orders of magnitude enhanced sensitivity allowing for vapor detection at the parts-per-quadrillion levels when an AFT is coupled to a mass spectrometer (MS). The goal of this project was to demonstrate the feasibility of integrating an AFT ionization source to a more portable ion mobility spectrometer (IMS). This project was successful in integrating AFT to IMS, as shown in Figure ES.1. The PNNL team demonstrated measurable ion signal from an AFT-IMS with a Faraday plate detector. Reasonable ion signals were detectable at low flow rates approaching 1 m/s. This is close to the flow rates used with the AFT-MS, which has demonstrated parts-per-quadrillion vapor detection. Vapor detection enables non-contact detection of a variety of illicit substances for various applications including cargo screening, mail sorting facilities, and checkpoints. With further improvements to enhance detection, AFT-IMS has the potential to allow ultra-trace vapor detection in a more portable device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delay-Line Anode For Microchannel-Plate Spectrometer

Photon-counting read-out system for microchannel-plate spectrometer includes delay line and timing circuit to measure wavelength coordinate and wedge/wedge charge-division system to measure orthogonal spatial coordinate. System proves advantageous for portable two-dimensional spectrometers having large image planes and for which design requirements include simplicity, reliability, low power consumption, and low mass.

Lampton, M.↗

Mass Spectrometer Containing Multiple Fixed Collectors

A miniature mass spectrometer that incorporates features not typically found in prior mass spectrometers is undergoing development. This mass spectrometer is designed to simultaneously measure the relative concentrations of five gases (H2, He, N2, O2, and Ar) in air, over the relative-concentration range from 10(exp -6) to 1, during a sampling time as short as 1 second. It is intended to serve as a prototype of a product line of easy-to-use, portable, lightweight, highspeed, relatively inexpensive instruments for measuring concentrations of multiple chemical species in such diverse applications as detecting explosive or toxic chemicals in air, monitoring and controlling industrial processes, measuring concentrations of deliberately introduced isotopes in medical and biological investigations, and general environmental monitoring. The heart of this mass spectrometer is an integral combination of a circular cycloidal mass analyzer, multiple fixed ion collectors, and two mass-selective ion sources. By circular cycloidal mass analyzer is meant an analyzer that includes (1) two concentric circular cylindrical electrodes for applying a radial electric field and (2) a magnet arranged to impose a magnetic flux aligned predominantly along the cylindrical axis, so that ions, once accelerated into the annulus between the electrodes, move along circular cycloidal trajectories. As in other mass analyzers, trajectory of each ion is determined by its mass-to-charge ratio, and so ions of different species can be collected simultaneously by collectors (Faraday cups) at different locations intersected by the corresponding trajectories (see figure). Unlike in other mass analyzers, the installation of additional collectors to detect additional species does not necessitate increasing the overall size of the analyzer assembly.

Moskala, Robert↗

Matrix-Assisted Ionization of Molecular Uranium Species

Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

NASA Tech Briefs, March 2012

The topics include: 1) Spectral Profiler Probe for In Situ Snow Grain Size and Composition Stratigraphy; 2) Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control; 3) In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer; 4) Physics Mining of Multi-Source Data Sets; 5) Photogrammetry Tool for Forensic Analysis; 6) Connect Global Positioning System RF Module; 7) Simple Cell Balance Circuit; 8) Miniature EVA Software Defined Radio; 9) Remotely Accessible Testbed for Software Defined Radio Development; 10) System-of-Systems Technology-Portfolio-Analysis Tool; 11) VESGEN Software for Mapping and Quantification of Vascular Regulators; 12) Constructing a Database From Multiple 2D Images for Camera Pose Estimation and Robot Localization; 13) Adaption of G-TAG Software for Validating Touch and Go Asteroid Sample Return Design Methodology; 14) 3D Visualization for Phoenix Mars Lander Science Operations; 15) RxGen General Optical Model Prescription Generator; 16) Carbon Nanotube Bonding Strength Enhancement Using Metal Wicking Process; 17) Multi-Layer Far-Infrared Component Technology; 18) Germanium Lift-Off Masks for Thin Metal Film Patterning; 19) Sealing Materials for Use in Vacuum at High Temperatures; 20) Radiation Shielding System Using a Composite of Carbon Nanotubes Loaded With Electropolymers; 21) Nano Sponges for Drug Delivery and Medicinal Applications; 22) Molecular Technique to Understand Deep Microbial Diversity; 23) Methods and Compositions Based on Culturing Microorganisms in Low Sedimental Fluid Shear Conditions; 24) Secure Peer-to-Peer Networks for Scientific Information Sharing; 25) Multiplexer/Demultiplexer Loading Tool (MDMLT); 26) High-Rate Data-Capture for an Airborne Lidar System; 27) Wavefront Sensing Analysis of Grazing Incidence Optical Systems; 28) Foam-on-Tile Damage Model; 29) Instrument Package Manipulation Through the Generation and Use of an Attenuated-Fluent Gas Fold; 30) Multicolor Detectors for Ultrasensitive Long-Wave Imaging Cameras; 31) Lunar Reconnaissance Orbiter (LRO) Command and Data Handling Flight Electronics Subsystem; and 32) Electro-Optic Segment-Segment Sensors for Radio and Optical Telescopes.

Source record↗

Evaluation of Small Mass Spectrometer Systems

This work is aimed at understanding the aspects of designing a miniature mass spectrometer (MS) system. A multitude of commercial and government sectors, such as the military, environmental agencies and industrial manufacturers of semiconductors, refrigerants, and petroleum products, would find a small, portable, rugged and reliable MS system beneficial. Several types of small MS systems are evaluated and discussed, including linear quadrupole, quadrupole ion trap, time of flight and sector. The performance of each system in terms of accuracy, precision, limits of detection, response time, recovery time, scan rate, volume and weight is assessed. A performance scale is setup to rank each systems and an overall performance score is given to each system. All experiments involved the analysis of hydrogen, helium, oxygen and argon in a nitrogen background with the concentrations of the components of interest ranging from 0-5000 part-per-million (ppm). The relative accuracies of the systems vary from < 1% to approx. 40% with an average below 10%. Relative precisions varied from 1% to 20%, with an average below 5%. The detection limits had a large distribution, ranging from 0.2 to 170 ppm. The systems had a diverse response time ranging from 4 s to 210 s as did the recovery time with a 6 s to 210 s distribution. Most instruments had scan times near, 1 s, however one instrument exceeded 13 s. System weights varied from 9 to 52 kg and sizes from 15 x 10(exp 3)cu cm to 110 x 10(exp 3) cu cm.

Arkin, C. Richard↗

Evolved Gas Analysis of Mars Analog Samples from the Arctic Mars Analog Svalbard Expedition: Implications for Analyses by the Mars Science Laboratory

The 2011 Arctic Mars Analog Svalbard Expedition (AMASE) investigated several geologic settings on Svalbard, using methodologies and techniques being developed or considered for future Mars missions, such as the Mars Science Laboratory (MSL). The Sample Analysis at Mars (SAM) instrument suite on MSL consists of a quadrupole mass spectrometer (QMS), a gas chromatograph (GC), and a tunable laser spectrometer (TLS), which analyze gases created by pyrolysis of samples. During AMASE, a Hiden Evolved Gas Analysis-Mass Spectrometer (EGA-MS) system represented the EGA-QMS capability of SAM. Another MSL instrument, CheMin, will use x-ray diffraction (XRD) and x-ray fluorescence (XRF) to perform quantitative mineralogical characterization of samples. Field-portable versions of CheMin were used during AMASE. AMASE 2011 sites spanned a range of environments relevant to understanding martian surface materials, processes and habitability. They included the basaltic Sverrefjell volcano, which hosts carbonate globules, cements and coatings, carbonate and sulfate units at Colletth0gda, Devonian sandstone redbeds in Bockfjorden, altered basaltic lava delta deposits at Mt. Scott Keltie, and altered dolerites and volcanics at Botniahalvoya. Here we focus on SAM-like EGA-MS of a subset of the samples, with mineralogy comparisons to CheMin team results. The results allow insight into sample organic content as well as some constraints on sample mineralogy.

McAdam, A.↗

Portable fiber optic sensor for rare earth elements and other critical metals using photoluminescence methods

Rare earth elements and other metals are vital to a range of technologies that are used in the energy and defense sectors. However, monopolistic market conditions have caused significant concern over the stability of the critical metal supply chain, and this has spurred extensive efforts in many nations to produce these metals domestically, both from conventional sources such as mining and well as from unconventional sources such as coal and its utilization byproducts. Slow and expensive characterization methods pose a significant barrier for both metals prospecting and process monitoring. A promising solution to this challenge is the development of highly sensitive luminescent sensors for metals, which can offer low costs, portability, and sensitivity. Anionic zinc adeninate metal-organic frameworks (BioMOFs) are known to distinguishing and detect part-per-billion levels of terbium, europium, samarium, and dysprosium in water by sensitizing the narrow, element-specific emission bands from these lanthanides. Here, a BioMOF material is immobilized onto a large diameter, solarization-resistant fiber optic tip integrated with a portable, low-cost spectrometer for rare earth element sensing. Immobilizing the sensing material on fiber instead of dispersing the sensing material in solution offers several advantages: it facilitates solvent removal, which enhances luminescent signal from the sensitized lanthanides, and it also allows the BioMOF to be recycled for multiple uses. The sensing system was deployed on a simulated process stream and exhibited qualitative agreement with inductively-coupled plasma mass spectrometry for terbium and europium detection, highlighting the potential for the sensing system to be deployed for real-world applications. By using different sensing materials, the same portable sensor may be deployed to detect other energy relevant metals such as cobalt, providing a cost-effective and sensitive platform for critical metal characterization.

Crawford, Scott↗