Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position-sensitive detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A position-sensitive X-ray detector for the HEAO-A satellite.

A position-sensitive, low-energy proportional counter system is described which will be used on the High-Energy Astronomical Observatory, Mission A, spacecraft. The associated system incorporates the capability to employ pulse-shape discrimination for background rejection and interpolation circuitry to locate the centroid of an X-ray event with an accuracy of approximately one eighth the cathode-wire spacing.

Held, D.↗

Wedge-and-strip anodes for centroid-finding position-sensitive photon and particle detectors

The paper examines geometries employing position-dependent charge partitioning to obtain a two-dimensional position signal from each detected photon or particle. Requiring three or four anode electrodes and signal paths, images have little distortion and resolution is not limited by thermal noise. An analysis of the geometrical image nonlinearity between event centroid location and the charge partition ratios is presented. In addition, fabrication and testing of two wedge-and-strip anode systems are discussed. Images obtained with EUV radiation and microchannel plates verify the predicted performance, with further resolution improvements achieved by adopting low noise signal circuitry. Also discussed are the designs of practical X-ray, EUV, and charged particle image systems.

Martin, C.↗

The Photicon

The Photicon is a novel imaging optical detector utilizing a conventional semitransparent photocathode, imaging electrostatic optics, microchannel plates, and a crossed-wire-grid position-sensitive charge detector. Its sensitivity to single optical photons over a two-dimensional area, high-resolution imaging, and timing capability render it useful for recording scintillations from X-ray image converters in X-ray astronomy. A digital word indicating the position of a single photon event is produced; the image can be stored in an array or serially. Spatial resolution to 20 microns in a 25 mm diam active area detector is reported, and modifications to achieve a spectral range of 120-730 nm are mentioned.

Kellogg, E.↗

Calibration and performance of the energetic X-ray imaging telescope experiment

The final integration and testing of the Energetic X-ray Imaging Telescope Experiment (EXITE) are described. The detector and telescope as finally assembled are described, and problems as well as solutions are detailed. The preflight calibration of the position-sensitive NaI detector revealed unanticipated effects in the energy spectra. In particular, an effect due to surface roughness (lack of firm optical polishing) on the crystal was found and calibrated. The radial variation of gain and resolution in the detector was also measured, and so-called flat fielding methods have been derived to analyze the data. The integration of the EXITE detector and gondola systems is described. Several novel features were developed for the EXITE gondola, most notably a shock absorber system. The performance of the detector and gondola systems was evaluated on a first balloon flight from Australia (May 1988) and a second flight from Ft. Sumner, New Mexico (October 1988).

Braga, Joao↗

Solar aspect determination system

Sensor containing commercially available solid-state position-sensitive light detector provides complete space-vehicle sun or moon vector information.

Farthing, W. H.↗

The curved crystal X-ray spectrometer for the HEAO-B satellite

The Focal Plane Crystal Spectrometer on HEAO-B is a moderate to high resolution, curved-crystal, Bragg spectrometer which operates behind a grazing incidence X-ray telescope. It is designed to allow detailed spectral studies of both point and extended celestial X-ray sources in the energy range 0.2-3.3 keV, with resolutions of 50 to 1000. The analyzing elements are six torroidal diffractors, and the detectors are position-sensitive, flow, proportional counters. HEAO-B is scheduled for launch in June, 1978.

Canizares, C. R.↗

Direct detection of XUV radiation with a CCD

A thinned CCD illuminated from the back has been used for direct imaging in the 584 and 304 A resonance lines of helium and in the 736 A line of neon. During operation, the CCD was cooled to minus 10 C and output was displayed on a CRT screen or in numerical printout. The results demonstrate that the back-illuminated CCD can be used as a position-sensitive flux detector with good imaging properties over a wide range of photon energies, including the extreme ultraviolet.

Burstein, P.↗

The energetic X-ray imaging telescope experiment (EXITE)

A new position-sensitive scintillation detector (NaI(Tl)), coded mask, and precision pointing system (resolution less than 1 arcmin) are being developed for balloon-borne imaging and spectral studies of cosmic X-ray sources in the 20-300 keV band. The scientific objectives of EXITE, as well as the general design of the detector, telescope and balloon gondola systems are presented.

Grindlay, J. E.↗

Planar double delay-line readout technique for microchannel plate detectors

A two-dimensional position-sensitive electrical readout system for microchannel plate detectors in spectroscopic applications has been devised. Two adjacent parallel coplanar delay lines are used. The difference in time of arrival of the electron event signal between the ends of the delay lines gives one coordinate of the centroid of each event pulse. The ratio of the event amplitudes on the two delay lines gives the orthogonal coordinate by means of charge partitioning. The performance characteristics of operational double delay lines for systems of this type are presented.

Lampton, M.↗

Separation of surface and bulk minority-carrier lifetimes in silicon

A photoexcitation technique is suggested which is direct and convenient, requiring little special equipment. No change in the dimensions of the crystal sample is necessary. Although related to the technique of interposing a filter between the light source and the sample, it differs in that the filter is part of the crystal itself. Basically, one of the electrodes is split into two electrodes, one collecting charge from carriers excited in the bulk. This phenomenon in which the carriers follow very closely the electric field lines has been used in position-sensitive semiconductor radiation detectors (Norbeck and Carlson, 1963) but has not been applied to lifetime measurements. In a sense, the split electrode creates a sample without a surface.

Carroll, K. A.↗

Soft X-ray spectrographs for solar observations

Recent advances in soft X-ray spectrometery are reviewed, with emphasis on techniques for studying the windowless region from roughly 1-100 A. Recent technological developments considered include multilayer mirrors, large-format CCD detectors which are sensitive to X-rays, position-sensitive photon counting detectors, new kinds of X-ray films, and optical systems based on gratings with nonuniform ruling spacings. Improvements in the extent and accuracy of the atomic physics data sets on which the analysis of spectroscopic observatons depend are also discussed.

Bruner, M. E.↗

Hybrid gas scintillation proportional counter/phoswich detector for hard X-ray astronomy

A concept is presented for a balloon-borne imaging hybrid proportional counter/phoswich detector of medium to hard X-rays. The phoswich would be optically coupled to the exit window of the proportional counter, and both detectors would use a common position-sensitive readout. It is anticipated that such a detector could combine the good energy and position resolution and excellent background rejection ability of the proportional counter for incident photon energies less than 100 keV with the extended response of the phoswich for higher energies. The phoswich could also be used to reject Compton scattering events in the proportional counter. This detector concept is studied using numerical simulations of a 400 sq cm square prototype detector. Results from this simulation indicate that current levels of proportional counter and phoswich performance are attainable at small cost in quantum efficiency, compared to a bare phoswich detector.

Grindlay, Jonathan E.↗

The nuclear and ionic charge distribution particle experiments on the ISEE-1 and ISEE-C spacecraft

The ISEE-1 and ISEE-C instruments are designed to measure the elemental abundances, charge state composition, energy spectra, and angular distributions of energetic ions in the energy range 2 keV/charge to 80 MeV/nucleon and electrons between 75 and 1300 keV. The instrument consists of three sensor systems: (1) ULECA which is an electrostatic deflection system with rectangular solid-state detectors for the 3-560 keV/charge range; (2) ULEWATT which is a double dE/dX vs E thin-window flowthrough proportional counter/solid-state detector telescope for the 0.2-80 MeV/nucleon (Fe) range; and (3) ULEZEQ which is a combination of an electrostatic deflection analyzer and a thin-window dE/dX vs E system with thin-window proportional counter and position-sensitive solid-state detector. The applications of the instruments to solar and interplanetary phenomena and to magnetospheric acceleration and trapped particles are discussed.

Hovestadt, D.↗

Development of a fast ion mass spectrometer for space research

An ion mass spectrometer having a cylindrical E bar x B bar analyzer and either a cylindrical or spherical electrostatic analyzer is described. The instrument has two nested channels and a postacceleration between the electrostatic and E bar x B bar analyzers for wide ranges of energy and mass responses. It is noted that the dual-channel construction not only doubles the data acquisition rate but also permits a reversal of the electrostatic field orientation in the inner channel for lighter ions. The outer channel is then optimized for ions of medium to high mass numbers, resulting in increased mass resolution for such heavy ions. When combined with a cylindrical E bar x B bar analyzer, a 90-deg-deflection angle spherical electrostatic analyzer provides an extremely wide viewing angle. The angular distribution of ions can be derived from such geometry if a position-sensitive resistive anode or a detector array is used at the exit aperture. Details on the principles of operation, the instrument design, and calibration are presented.

Hahn, S. F.↗

Studies with the Pinhole/Occulter Facility

The scientific justifications for high-resolution hard X-ray astronomy are reviewed, and a scheme for making such observations from the Space Shuttle payload bay is presented. High-resolution X-ray observations at photon energies above 10 keV are important for the understanding of the physics of solar flares, coronal disturbances related to flares, and corona fine structure, as well as nonsolar X-ray sources. In order to study these phenomena, concepts have been developed for the Shuttle Pinhole/Occulter Facility (P/OF), an instrument based on the principles of the pinhole camera which will have an angular resolution of 0.2 arc sec. The proposed P/OF configuration consists of four separate telescopes or position-sensitive counters mounted on a detector plane and looking toward the target through separate portions of an aperture mask (occulter plane). The two planes are separated by a self-deployable 50-m boom, which is to be made essentially rigid by direct control of its lowest normal modes.

Tandberg-Hanssen, E.↗

Construction and evaluation of an imaging focussed-mesh electron multiplier for space instrumentation

A focused-mesh electron multiplier (FMEM) has been combined with a wedge and strip position-sensitive anode to create a novel detector that is considered likely to have a number of applications in space astronomy and laboratory image sensing. Results from the first application of a wedge and strip anode to an FMEM are presented including spatial resolution, spatial linearity, background rate, and pulse risetime. The converted multiplier retains the attributes of an FMEM that made it attractive in the first place, such as low background, high speed, and high dynamic range.

Vallerga, J.↗

The development and test of ultra-large-format multi-anode microchannel array detector systems

The specific tasks that were accomplished with each of the key elements of the multi-anode microchannel array detector system are described. The modes of operation of position-sensitive electronic readout systems for use with high-gain microchannel plates are described and their performance characteristics compared and contrasted. Multi-anode microchannel array detector systems with formats as large as 256 x 1024 pixels are currently under evaluation. Preliminary performance data for sealed ultraviolet and visible-light detector tubes show that the detector systems have unique characteristics which make them complementary to photoconductive array detectors, such as CCDs, and superior to alternative pulse-counting detector systems employing high-gain MCPs.

Timothy, J. G.↗

A position sensitive microchannel photomultiplier for ultraviolet space astronomy

The 25-mm microchannel-plate, position-sensitive UV astronomy photomultiplier tube presented is intended for the EOM-1 Spacelab Mission's FAUST payload and conducts wide-field imaging surveys in the VUV over the 1400-1800-A range. The sealed detector encompasses a CsI photocathode deposited on the inner surface of a MgF2 window, a stack of microchannel plates, and a wedge-and-strip two-dimensional position-sensing anode. Since the wedge-and-strip principle requires only three anode signals, flight electronics can be reduced to three charge amplifiers and three analog-to-digital converters.

Lampton, M.↗