Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position-sensitive detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

36 records · Page 2

Epithermal Neutron Resonance Analysis Using a Compact D-T Generator

Nuclear material identification and isotopic composition analysis are important capabilities for safeguards and the verification of nuclear arms control and nonproliferation treaties. Epithermal neutron resonance imaging has been proposed for spent fuel assay measurements, and the development of a mobile neutron imaging system could provide such a tool for on-site applications. This technique is highly sensitive to isotopes of interest for safeguards applications (e.g. 235,238 U, 238,239,240 Pu) and yields unique transmission spectra for a target containing actinides and some mid- and high-Z elements. Paired with a position-sensitive neutron detector, such a system could provide spatial information of the target isotopic composition. Recent progress in the development of high intensity neutron sources could make mobile epithermal neutron imaging designs increasingly feasible to serve as a tool for nuclear inspectors. In this work, Monte Carlo (MC) simulations were performed to further optimize a previous design for an epithermal neutron resonance-based analysis apparatus using a D-T portable neutron generator. Additionally, experimental work is being performed to test the feasibility of this method. The MC simulations of moderation time distributions for different moderator compositions and thicknesses were measured to provide a multi-group correction for neutron time-of-flight energy reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3x3 array module of 8×8×32 mm 3 position-sensitive virtual frisch-grid CdZnTe detectors for imaging and spectroscopy of cosmic gamma-rays

Here, we evaluated the performance of the 3x3 array of 32-mm long position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors read out by the IDEAS GDS-100 data acquisition system. The array is a mechanically solid module designed for integration into a large effective area gamma-ray telescope proposed for imaging and spectroscopy of cosmic gamma-rays. The array employs the bar-shaped 8x8x32 mm 3 CZT crystals which recently became available from Redlen Technologies, Inc. and Kromek-eV Group PLC at affordable costs. The waveform sampling IDE3421 application-specific integrated circuit (ASIC), developed by the University of Michigan and IDEAS for CZT pixel detectors, was adapted to capture the signals from the array's VFG detectors. We showed good spectral performance of the Redlen detectors with an energy resolution of <1% FWHM at 662 keV and slightly poorer performance of the Kromek-eV detectors with a resolution of <2% measured at a reduced temperature of 13 °C. By testing the same detectors as single devices using hybrid charge-sensitive preamplifiers, we demonstrated improved energy resolutions at a normal temperature of ~25°C: <1% and 1.3-1.7%, respectively. However, the Kromek-eV detectors did not perform as well as the Redlen ones. We explained this by the space charge formation (polarization) decreasing the electric field and the electron drift times. The polarization was likely caused by the high injections of holes from the anode contacts. The absence of polarization in Redlen detectors suggested that the quality of the contacts might have played a role in this case.

47 OTHER INSTRUMENTATION↗

Prospects for Surrogate Neutron Capture Measurements with Radioactive Ion Beams and GODDESS

Neutron capture reactions are responsible for the synthesis of almost all of the elements heavier than iron through the slow s-process, that proceeds close to the line of stability, and the rapid r-process, with very neutron-rich waiting points. Uncertainties in (n,γ) rates in neutron rich nuclei, especially near closed neu- tron shells, can have significant impact [1] on the predictions of final abundances for different astrophysical scenarios for the r process. Understanding (n,γ) rates on neutron-rich fission fragments is also important for nuclear forensics and stockpile stewardship science. Ratkiewicz et al. [2 and references therein] has recently demonstrated that the (d,pγ) reaction is a valid surrogate for (n,γ), where the formation of the compound nucleus from the breakup of the deuteron has been calculated in a reaction model and the subsequent measured gamma-decay probabilities are reproduced with standard level density and strength functions in a Bayesian approach. In parallel to the surrogate validation efforts, we have demonstrated that the (d,pγ) reaction can be measured in inverse kinematics with Gammasphere ORRUBA: Dual Detectors for Experimental Structure Studies (GODDESS) [3] where the Gammasphere array of Compton-suppressed HPGe detectors is coupled to the Oak Ridge Rutgers University Barrel Array of position-sensitive silicon strip detectors. During the commissioning campaign we measured the (d,pγ) reaction with 134 Xe and 95 Mo beams, the latter to demonstrate the surrogate method in inverse kinematics. The present talk will present preliminary results from this campaign including γ-decay probabilities and prospects for surrogate (n,γ) measurements with 143 Ba fission-fragment beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Multianode Photomultiplier Tubes for use in the CLAS12 RICH detector

In this work, we present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high voltages and light intensities of the laser test setup. Using the same dedicated front-end electronics as in the first RICH detector, the setup allowed us to characterize each pixel’s properties such as gain, quantum efficiency, signal crosstalk between neighboring pixels, and determine the signal threshold values to optimize their efficiency to detect Cherenkov photons. A recently published state-of-the-art mathematical model, describing photon detector response functions measured in low light conditions, was extended to include the description of the crosstalk contributions to the spectra. The database of extracted parameters will be used for the final selection of the MaPMTs, their arrangement in the new RICH detector, and the optimization of the operational settings of the front-end electronics. The results show that the characteristics of the H12700 MaPMTs satisfy our requirements for the position-sensitive single photoelectron detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

24.1.3.1.1 - Frisch Grid CZT Spectrometer

Brookhaven National Laboratory (BNL) worked with FLIR System Inc., the manufacturer of the nanoRAIDER, to develop a handheld field deployable detector based on the novel position-sensitive virtual Frisch-grid (VFG) Cadmium-Zinc-Telluride (CdZnTe or CZT) detectors (with 1% FWHM at 662 keV or better energy resolution). The detector called nanoRAIDER-VFG would be an improvement to the current nanoRAIDER, which is a compact gamma-ray detection instrument manufactured by FLIR Systems Inc. that employs relatively lower-performing CZT hemispheric detectors (i.e., 3%-FWHM CZT detectors). The nanoRAIDER-VFG would have significantly improved accuracy of measurements while maintaining similar efficiency, as compared to the nanoRAIDER, for in-field analysis of nuclear materials and detection of undeclared activities during inspections conducted by the International Atomic Energy Agency (IAEA). Since the nanoRAIDER is currently used by the IAEA as part of its Complementary Access toolkit, a relatively quick acceptance of the nanoRAIDER-VFG for safeguards was anticipated. The nanoRAIDER-VFG project was undertaken to address the following items in the IAEA's Long-Term R&D Plan, 2012-2023: 2.2 (elemental and isotopic signatures of fuel cycle processes); 2.3 (detect signatures of undeclared activity and improve analysis); and 2.6 (detect process emanations). The high energy-resolution of the nanoRAIDER-VFG would also have had applicability to 3.2 (fissile content of metal mixtures containing actinides Np, Am, etc.). The project was not completed due to a change in priorities within FLIR.

36 MATERIALS SCIENCE↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Development of a low-pressure Multi-Mesh THGEM detector for fission experiments at FRIB

Abstract A small-area imaging detector prototype for position measurement of fission fragments produced in low energy heavy-ion reactions is presented in this study. The detector readout is equipped with a 2-dimensional, position-sensitive gaseous avalanche readout based on the novel Multi-Mesh Thick-GEM (MM-THGEM), and is coupled to a delay-line board for particle localization. The prototype has an effective area of 10 × 10 cm 2 and is operated in isobutane at low pressure (7–10 Torr). We present and discuss a series of systematic evaluation tests performed by irradiating the detector with α-particles and fission fragments emitted by small-rate sources ( 241 Am, 249 Cf and 252 Cf). Position and time resolutions of about 0.42 mm and 1 ns were achieved, respectively. This work serves as a benchmark for the development of a large-scale array of detectors for experiments with fission and fission-like reaction products at the Facility for Rare Isotope Beams (FRIB).

Instruments & Instrumentation↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thickness and uniformity mapping of thin foils using resistive silicon detectors

Alpha energy loss is a common tool used for measuring target thicknesses. However, these measurements are often made without position information, which either forfeits knowledge of material uniformity and local thickness or requires a prohibitive number of measurements per target to partially recover this information. In consideration of this, a method for measuring position-dependent thicknesses is described in this work; by using the position-sensitivity of the dual-axis duo-lateral (DADL) silicon detector, thicknesses across the entire face of the material can be measured to sub-mm precision with a single measurement. Several examples are presented using a number of targets with varying characteristics, which altogether demonstrate the precision, accuracy, and versatility of this technique.

Foil uniformity↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

A Call to Arms Control: Synergies between Nonproliferation Applications of Neutrino Detectors and Large-Scale Fundamental Neutrino Physics Experiments (A Snowmass White Paper)

The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts. Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security Administration (NNSA), have been studying a range of possible applications of relatively large (100 ton) to very large (hundreds of kiloton) water and scintillator neutrino detectors. In parallel, the fundamental physics community has been developing detectors at similar scales and with similar design features for a range of high-priority physics topics, primarily in fundamental neutrino physics. These topics include neutrino oscillation studies at beams and reactors, solar, and geological neutrino measurements, supernova studies, and others. Examples of ongoing synergistic work at U.S. national laboratories and universities include prototype gadolinium-doped water and water-based and opaque scintillator test-beds and demonstrators, extensive testing and industry partnerships related to large area fast position-sensitive photomultiplier tubes, and the development of concepts for a possible underground kiloton-scale water-based detector for reactor monitoring and technology demonstrations. Some opportunities for engagement between the two communities include bi-annual Applied Antineutrino Physics conferences, collaboration with U.S. National Laboratories engaging in this research, and occasional NNSA funding opportunities supporting a blend of nonproliferation and basic science R&D, directed at the U.S. academic community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrades to the TRIUMF Fast Ion Counter, TRIFIC

TRIFIC, the TRIUMF Fast Ion Counter, is a downstream ionization chamber which provides beam composition monitoring and recoil tagging for in-beam reaction experiments. TRIFIC has been commissioned and deployed for use with radioactive isotope beams at the TRIUMF-ISAC facility. Recently, the detector has been upgraded to include an improved gas window that can accommodate higher beam rates and position-sensitive electrode grids for better position reconstruction.

Gaseous detectors↗

Half-life measurement of the 199-keV isomeric state in Ga 76

Background: Isomeric states in atomic nuclei are a sensitive probe of their underlying microscopic structure and can be used to study the evolution of shell structure far from stability. Recent studies have identified and provided detailed spectroscopy of isomers in neutron-rich nuclei with Z = 28-50. Isomeric states in the odd-odd gallium isotopes have been reported for all gallium isotopes from A = 72 to A = 80 with the exception of 76 Ga. Purpose: The purpose of this experiment was to observe short-lived isomeric states in the vicinity of 78 Ni. Methods: In-beam fragmentation of a 86 Kr primary beam at the National Superconducting Cyclotron Laboratory produced radioactive ions which were delivered to and deposited in a Ce Br 3 scintillator coupled to a position-sensitive photomultiplier tube. Beta-delayed γ rays were measured by ancillary HPGe clover and LaBr 3 detectors which surrounded the implantation detector. Results: The previously observed J π = 1 + , 199-keV level in 76 Ga, populated following the β decay of 76 Zn, was identified as isomeric with a half-life of 34(1) stat. (8) sys. ns. Shell-model calculations suggest this state is formed by the coupling of protons in negative-parity configurations to 1/2 - neutron configurations. Transition strengths assuming a ground-state spin of J = 2 and J = 3 were determined from the experimental data.

59 ≤ A ≤ 89↗

Improving Chirped Fiber Bragg Grating Resolution for Position-Sensitive Sensors in Shock- and Detonation-Driven Experiments

Chirped fiber Bragg gratings (CFBGs) are robust diagnostic sensors that are widely used to track detonation-driven and shock wave propagation. CFBGs are inscribed with a linearly chirped periodic index of refraction changes that alter the Bragg wavelength along the length of the probe. The light return of each individual Bragg element is captured by a detector at a unique time to map the full reflected spectrum. The CFBG spectrum is measured with a dispersive Fourier transform of the reflected light that temporally stretches the spectrum to increase spatial resolution and make a one-to-one map of the wavelength on a time axis. Here, we propose an improvement of CFBG temporal resolution by incorporating two co-linear laser pulses with orthogonal polarization states and a 5 ns time offset. The two separate signals were split and tracked by two separate detectors. An oscilloscope captured good separation in the signals, and two separate spectrograms were generated and interleaved in the post-processing of the data. This novel technique doubled the CFBG temporal resolution and led to a doubled location resolution. As a proof-of-concept of this technique, the resolution improvement was compared between standard CFBG measurements and the two polarization states method on a position-sensitive CFBG sensor. CFBG resolution doubling will advance sensor capabilities and will have a direct impact on improving capture and analysis in dynamic, high-explosive experiments.

42 ENGINEERING↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗