At least 37 records · Page 2

Guest Editorial Special Section on Advanced Medium-Voltage Power Electronics for Grid Interactive Applications

Medium-voltage power electronics (MVPE) plays essential roles in power grid modernization and links the MV distribution grid with low-voltage consumers and prosumers. Various MVPE devices, such as solid-state transformers or circuit breakers, inverter-based resources, power flow controllers, etc., bring the benefits of voltage conversion and power regulation in small footprint, power quality and efficiency improvements, and enhancements of grid controllability, flexibility, stability, and resilience. The MVPE also makes it possible for sustainable energy systems, such as solar/wind farms and energy storage generating facilities, to directly access to MV grids without multistage conversions. With their intrinsic intelligence and communications, MVPE enables many new smart grid functions and applications, e.g., dc interconnections and electric vehicle charging, which were not envisioned by traditional power grids otherwise. In addition, the integration of physical power processing units with cyber components forms a cyber-physical system, which is essential for long-term sustainability, development, and environmental preservation. Nonetheless, technical challenges on MVPE device reliability, scalable and efficient converter topologies, control stability, large-scale modeling and simulation, to name a few, need to be addressed and advanced to the next level. In conclusion, this Special Section on Advanced MV Power Electronics for Grid Interactive Applications in IEEE Transactions on Power Electronics (TPEL) provides an insight on some of the recent advances in MVPE and emerging challenges and potential solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Wind turbine power phase control with DC collection bus for onshore/offshore windfarms

A DC bus collection system for a wind farm reduces the overall required number of converters and minimizes the energy storage system requirements. The DC bus collection system implements a power phasing control method between wind turbines that filters the variations and improves power quality. The phasing control method takes advantage of a novel power packet network concept with nonlinear power flow control design techniques that guarantees both stable and enhanced dynamic performance.

Weaver, Wayne W.↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Computationally Improved Heuristic Algorithm for Transmission Switching Using Line Flow Thresholds for Load Shed Reduction

We present a computationally improved heuristic algorithm for transmission switching (TS) to recover load shed. Research from the past showed that changing power system topology may control power flows and remove line congestion. Hence, TS may reduce the required load shed. One of the main challenges is to find a potential TS candidate in a suitable time. Here, we propose a novel heuristic method that is capable of finding the potential TS candidate faster than existing algorithms in literature. The proposed method is compatible with both the AC and DC optimal power flows (OPF). Three metrics are used to compare the proposed algorithm with the state-of-the-art from literature to show the speedup and accuracy achieved. The proposed method is implemented on the IEEE 30-bus system, PEGASE 89-bus system, IEEE 118-bus system, and Polish 2383- bus system. The results on the large-scale Polish 2383-bus system shows that the proposed algorithm is scalable to large real-world systems. Parallel computing is implemented to further improve the computational performance of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Protection of Grid-Connected Devices Through Embedded Online Security

Cybersecurity research regarding the electric power grid has primarily been focused on protecting the communication layer of grid-connected devices against cyber-attack threats. Although many developed methods have greatly reduced the effects of a cyber-attack on the vulnerabilities of grid-connected devices, discovering new vulnerabilities is inevitable and a constant threat. As a result, the overall reliability and security of network communications with regard to grid-connected devices is a concern. Here, this paper proposes a method that further secures a system by focusing on the control and hardware layer of grid-connected devices. The device’s controller firmware will be validated and authenticated using integrated device emulation resources prior to being activated to control the grid-connected device. This verification process is performed while the controller is online and actively controlling power flows related to the device. Therefore, an attack to the system through a malicious firmware patch would be detected by the online security and rejected while safely maintaining continuous and stable control of the device. This method integrates the concepts of firmware hot-patching, digital twins, and active monitoring into an overall cybersecurity protection system.

cybersecurity↗

Advanced Transmission Technologies – GETs and HPCs Session 1: ATT Foundations and Dynamic Line Ratings (DLRs)

The INL TADA GETs Cohort Session 1, held on November 4, 2025, convened experts to address the integration of advanced transmission technologies, including Grid-Enhancing Technologies (GETs) and High Performance Conductors (HPCs), with a focus on digital assurance challenges. The session highlighted the growing importance of cybersecurity, supply chain transparency, reliability, and business risk management in deploying GETs, especially Dynamic Line Ratings (DLRs). Participants examined how expanded attack surfaces, limited vendor pools, and new regulatory requirements—such as FERC Orders 881, 2023, and 1920—are influencing utilities and technology providers. The workshop underscored the need for cyber-informed engineering, secure-by-design principles, and practical risk management strategies, while fostering collaboration and knowledge sharing among industry peers. Technical discussions covered the evolution from static to dynamic line ratings, complexities of cloud-based architectures, and NERC CIP compliance challenges. The session concluded with a collaborative risk exercise and a preview of future workshops on advanced power flow control and transmission topology optimization, reinforcing the cohort’s commitment to advancing digital assurance in the energy sector.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Demand Response Optimization and Management System for Real-TIme (DROMS-RT)

To design and demonstrate DROMS-RT, a highly distributed Demand Response Optimization and Management System for Real-Time (DROMS-RT) power flow control to support large scale integration of distributed renewable generation into the grid. AutoGrid developed a novel control and communications platform to allow highly dispatchable demand response (DR) services in time frames suitable for providing ancillary services to the transmission grid. These services will be substantially less expensive and more efficient than other forms of ancillary services options currently available to manage the intermittency associated with large-scale renewable integration. DROMSRT successfully leveraged Automated Demand Response (ADR) by fundamentally re-thinking the architecture of the DR platform from the ground up and by developing innovative new technologies in a number of areas related to DR. DROMS-RT leveraged the low-cost, open, interoperable DR signaling technology, OpenADR, and low-cost, internet-protocol based telemetry solutions to reduce the cost of hardware. This allowed DROMS-RT to provide dynamic price signals to millions of OpenADR clients. Statistically rigorous signal processing techniques were developed to reliably detect even small load reductions in the presence of noisy baseline profiles. Novel forecasting engines based on modern online machine learning algorithms enabled accurate individualized forecasts for customer loads in the presence of dynamic pricing signals, and a real-time decision engines enabled continuous optimization and optimal dispatch of DR resources across a large portfolio of heterogeneous loads that respond at varying time-scales. Moreover, the real-time optimization conducted by the decision engine can utilize grid physics to maximize load reduction at the transmission system in addition to the distribution sites, for more efficient grid operation. Finally, the Software-as-a-Service (SaaS) availability of the DROMS-RT platform has reduced the cost of deployment and enable participation of small commercial and residential customers in DR who otherwise would not be able to do so.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load Shed Recovery With Transmission Switching and Intentional Islanding Methods After (N-2) Line Contingencies

Changing power system configuration may result in load shed recovery (LSR) because topology change can provide power flow control in meshed network. Some topologies may favor generation redispatch as compared to others and can eliminate line congestion which leads to LSR. One of the known methods for topology change is called transmission switching (TS) and research conducted in the past showed that TS is an effective means of mitigating load shedding. Another method of topology control is intentional islanding (IIS). In this manuscript, we explore IIS as a potential solution for LSR. IIS based on generator coherency has been presented in literature for mitigating cascading failures. However, IIS has not been explored solely as a LSR mechanism. In this paper, we compare the LSR based on IIS with well known LSR algorithm based on TS. The comparison is performed for IEEE 39-bus system and IEEE 118- bus system. The results show that IIS has a potential to perform better than TS in terms of computational efficiency and LSR.

42 ENGINEERING↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

As we know, power transformers are the most critical asset of the transmission network. Although highly reliable, they still can fail prematurely or ultimately retire at the end of their service life. In today’s design practices, transformers are tailored to their specific application and therefore cannot replace each other unless identical. Additionally, they provide minimal support to the grid operation and therefore limit the grid flexibility and resiliency when facing severe conditions. In this presentation, we will introduce the concept of flexible power transformer and demonstrate how one single unit can serve as a spare to multiple units in a given fleet, allow to control the power flow between transformers or lines operating in parallel and ultimately be used to limit subsequent faults in transmission lines. We will also introduce the world’s first prototype in operation, a 60MVA, 165kV flexible autotransformer.

flexible power transformer, autotransformer, varia↗

Series FACTS Devices for Increasing Resiliency in Severe Weather Conditions

Severe weather conditions are low-probability, high-impact events that affect grid operations. The majority of power outages are caused by severe weather conditions. Grid resiliency to weather events can be enhanced by decreasing the reliance on its affected sections. One way to do this is to reduce the power flow through lines vulnerable to severe weather. If a line is disconnected, its initial power flow is distributed through the neighbor lines, which may cause congestion in the grid. FACTS devices can be used to control the power flow of lines that have a higher chance of power outages. Most previous works do not consider weather events in power flow control. In this work, a linearized optimal power flow (OPF)–based algorithm is developed to minimize the real power flow of vulnerable lines considering the thermal limits of lines to prevent infeasible solutions; the simulation is fast, making it suitable for large-scale systems. The proposed optimization problem is presented as a mixed-integer linear program (MILP), making it capable of using short-term load forecasting due to its high solution speed. The proposed optimization problem considers multiple lines with different outage probabilities and the uncertainties of the weather forecast. Moreover, it estimates the power reduction in vulnerable lines due to changes in the series FACTS devices. The performance of the proposed optimization problem is tested on IEEE 14-, 30-, and 118-bus systems for several scenarios. The results are validated with the AC power flow results from MATPOWER.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Privacy-Preserving Distributed Control of Optimal Power Flow

Here, we consider a distributed optimal power flow formulated as an optimization problem that maximizes a nondifferentiable concave function. Solving such a problem by the existing distributed algorithms can lead to data privacy issues because the solution information exchanged within the algorithms can be utilized by an adversary to infer the data. To preserve data privacy, in this paper we propose a differentially private projected subgradient (DP-PS) algorithm that includes a solution encryption step. We show that a sequence generated by DP-PS converges in expectation, in probability, and with probability 1. Moreover, we show that the rate of convergence in expectation is affected by a target privacy level of DP-PS chosen by the user. We conduct numerical experiments that demonstrate the convergence and data privacy preservation of DP-PS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design Principles for Resonant Wave Energy Converters: Benchmarking Power Capture and Flow

Control co-design (CCD) in Wave Energy Converters (WECs) integrates the controller, power take-off (PTO), and buoy models during system design to optimize power output. Using the bi-conjugate impedance matching principle, this study models the PTO as a two-port network, revealing impedance matching conditions at the input and output ports as a function of the buoy, PTO, and controller. Here, this study examines the pairing of a flywheel-type pitch resonator PTO within a given buoy constrained by limited space and ballast capacity. The results show that physical constraints imposed by the buoy affect PTO performance. While controller tuning achieves optimal output impedance matching and flywheel inertia is maximized within the buoy's limitations, the PTO's input impedance remains smaller than the complex conjugate of the buoy's intrinsic impedance. This mismatch limits the PTO's ability to generate sufficient reaction torque, particularly outside the resonance frequency, resulting in narrow-band power transfer. The findings emphasize the need for PTO design modifications to improve input power transfer. Pendulum-based PTO mechanisms are proposed as alternatives to couple with multiple buoy motion modes and improve wave-to-wire efficiency while respecting system constraints.

Control Co-Design↗

Visual Tool for Assessing Stability of DER Configurations on Three-Phase Radial Networks

Here, we present a method and tool for evaluating the placement of Distributed Energy Resources (DER) on distribution circuits in order to control voltages and power flows. Our previous work described Phasor-Based Control (PBC), a novel control framework where DERs inject real and reactive power to track voltage magnitude and phase angle targets. Here, we employ linearized power flow equations and integral controllers to develop a linear state space model for PBC acting on a three-phase unbalanced network. We use this model to evaluate whether a given inverter-based DER configuration admits a stable set of controller gains, which cannot be done by analyzing controllability nor by using the Lyapunov equation. Instead, we sample over a parameter space to identify a stable set of controller gains. Our stability analysis requires only a line impedance model and does not entail simulating the system or solving an optimization problem. We incorporate this assessment into a publicly available visualization tool and demonstrate three processes for evaluating many control configurations on the IEEE 123-node test feeder (123NF).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Minimization of the Power Generation Cost in Prosumer-Based Distribution Networks: Preprint

Traditionally, electrical power was generated in big power plants. The cost of producing energy was related to the cost of fuel, e.g., carbon or gas, and by the cost of maintaining the power plants. With the advent of distributed energy resources, power can be produced directly at the edge of the electrical network by a new type of agents: the prosumers. Prosumers are entities that both consume and generate power, e.g., by means of photovoltaic panels. The cost of the power produced by prosumers is no longer related to fuel consumption since energy coming from distributed generators is essentially free. Rather, the cost is related to the remuneration that is due to the prosumers for the services they provide. The proposed control strategy minimizes the active power generation cost in the aforementioned scenario. The control scheme requires that the prosumers measure their voltage and then adjust the amount of injected power, according to a continuous time feedback control law that is indeed a projected gradient descent strategy. Simulations are provided in order to illustrate the algorithm behavior.

distributed control↗