Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power delivery networks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Machine Learning-based False Data Injection Attack Detection and Localization in Power Grids

Cyberattacks on critical infrastructures can be catastrophic and bring nations to their knees. Therefore, detecting these attacks is crucial and challenging. This paper presents a novel approach for detecting and locating cyberattacks affecting an electrical power system. The adversary employs a man-in-the-middle technique to inject false data into the communication between distributed energy resources (DER) and Microgrid Controller (MGC) with the goal of disrupting power delivery. The approach for detection and localization is based on integrating multiple machine learning-based anomaly detection models that combine network traffic data and grid measurements. Experiments are performed to assess the method's performance using a hardware-in-the-loop real-time simulation testbed which includes Modbus TCP/IP communication. Power system topology and operating conditions are based on actual topology and real-world data provided by the Holy Cross Energy utility network. Results confirm that the method can be successfully employed for detecting and localizing cyberattacks.

Leao, Bruno P.↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

Cybersecurity for Electric Vehicle Charging Infrastructure

As the U.S. electrifies the transportation sector, cyberattacks targeting vehicle charging could impact several critical infrastructure sectors including power systems, manufacturing, medical services, and agriculture. This is a growing area of concern as charging stations increase power delivery capabilities and must communicate to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid operator communication systems could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks — or public perception of such — would ripple across the industry and produce lasting effects. Unfortunately, there is currently no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured inter faces. Comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project provided the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team created a cybersecurity threat model and performed a technical risk assessment of EVSE assets across multiple manufacturers and vendors, so that automotive, charging, and utility stakeholders could better protect customers, vehicles, and power systems in the face of new cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Center for Alternate Synchronization and Timing (CAST) PTP Network Monitoring Report

The Oak Ridge National Laboratory Center for Alternative Synchronization and Timing (CAST) performs research, development, testing, and evaluation of alternative terrestrial-based timing and synchronization infrastructure for the US power grid and other critical infrastructures. Alternative timing options reduce reliance on GPS and enhance the overall resilience of critical infrastructures. CAST infrastructure uses Precision Time Protocol (PTP) as the primary conduit for delivery of synchronization packets. CAST deploys PTP over long terrestrial links to synchronize a multitude of remote boundary clocks and downstream power grid components with the authoritative grand master clocks. Network traffic issues can severely degrade PTP accuracy. This report focuses on examining network traffic anomalies and their effects on PTP operation as well as the potential implications to CAST’s high-precision remote synchronization operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Securing Vehicle Charging Infrastructure

As the US electrifies the transportation sector, cyber attacks targeting vehicle charging could bring consequences to electrical system infrastructure. This is a growing area of concern as charging stations increase power delivery and must communicate to a range of entities to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and are complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid communication system cybersecurity could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks - or public perception of such - ripples across the industry and has lasting and devastating effects. Unfortunately, there is no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured interfaces. Thus, comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project is providing the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team is creating a cybersecurity threat model and performing a technical risk assessment of EVSE assets, so that automotive, charging, and utility stakeholders can better protect customers, vehicles, and power systems in the face of new cyber threats.

33 ADVANCED PROPULSION SYSTEMS↗

MPC4CLR (Model-Predictive-Control-for-Critical-Load-Restoration-in-Power-Distribution-Systems) [SWR-22-24]

Model predictive control (MPC) is a system or process control technique for making decisions under uncertainty via rolling look-ahead optimizations at each control step where only the current step decisions are applied, and the rest are discarded. In this work, we developed an MPC for a critical load restoration (CLR) in power distribution systems to recover system service (electricity delivery) following an extreme event-triggered substation outage. The method considers the problem of controlling distributed energy resources (DERs) of the distribution system with the objective of achieving maximum load pick up while satisfying distribution network flow and voltage constraints. A linearized optimal power flow (OPF) model is employed to represent the physics of the network. The problem formulation is augmented with a ramping (up) reserve product for the DERs to ensure improved and upward monotonic load restoration as time evolves. Simulation analysis and performance tests are performed using a modified IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage battery. The software is developed using various software packages in Julia and Python. The MPC model is implemented using the JuMP optimization language in Julia while the data analytics including renewable generation and load demand forecasts, running the MPC simulation and visualizations is performed in Python.

Eseye, Abinet Tesfaye↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration: Preprint

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Generic FSC Wind Park EMT Model with IEEE Std 2800-Compliant Fault Ride-Through Capability

The modern power grid is seeing more and more electricity come from renewable sources like wind farms, which use sophisticated power electronics instead of traditional spinning generators. To keep everything running smoothly and meet industry standards such as IEEE 2800, these systems need smart control strategies. In our work, we built a flexible computer model of a full-scale wind farm converter that can handle grid disturbances without shutting down. When a fault or storm hits, the model’s built-in logic automatically adjusts the currents it sends to the grid and protects its internal energy storage, ensuring the wind farm stays connected and doesn’t damage its own equipment. Once the disturbance clears, the model restores normal operation seamlessly, so there’s no long interruption in power delivery. At the same time, it carefully regulates the voltage where the wind farm ties into the larger grid, helping to maintain safe voltage levels across the network. Our simulations show that this control setup not only meets all the requirements of IEEE Standard 2800 but also allows the wind farm to recover quickly and predictably, keeping the lights on no matter what happens on the grid.

17 WIND ENERGY↗

FLISR in the Presence of DERs ADMS Test Bed Use Case

Fault location, isolation, and restoration (FLISR) is one of the distribution automation applications that utilities are most interested in. It operates groups of switches on distribution feeders to improve the reliability of power delivery after localizing outages. FLISR is an essential function for enabling a self-healing grid, and it directly affects grid reliability and resilience. The presence of DERs brings both new opportunities and challenges for FLISR applications. For instance, some DERs can work as backup generation sources and help energize local networks so more switching options can be achieved with the coordination of FLISR operations; however, the existence of DERs also brings new challenges. The bidirectional power flow resulting from DERs might require dynamic changes to protective devices' fault current settings, and thus the FLISR application will need to dynamically adjust its operations in coordination with the dynamic protection settings. Also, some FLISR applications make their service restoration decisions and close tie-switches based on predefined rules; however, the presence of DERs and their impact on altering net loads on the local feeder network are not considered. For this use case, the project team is using the FLISR application of the Survalent ADMS operating on a real-time simulation of a feeder from Central Georgia EMC, a cooperative electric utility. The performance of the FLISR application is being evaluated for different locations and combinations of DERs, including grid-forming battery energy storage systems.

ADMS↗

Joint routing of conventional and range-extended electric vehicles in a large metropolitan network

Range-extended electric vehicles combine the higher efficiency and environmental benefits of battery-powered electric motors with the longer mileage and autonomy of conventional internal combustion engines. This combination is particularly advantageous for time-constrained delivery routing in dense urban areas, where battery recharging along routes can be too time-consuming to economically justify the use of all-electric vehicles. However, switching from electric to conventional fossil fuel modes also results in higher costs and emissions and lower efficiency. This paper analyzes this heterogeneous vehicle routing problem and describes two solution methods: an exact branch-price-and-cut algorithm and an iterated tabu search metaheuristic. From a methodological perspective, we find that the exact algorithm consistently obtains tight lower bounds that also serve to certify the metaheuristic solutions as near-optimal. From a policy standpoint, we examine a large-scale real-world case study concerning parcel deliveries in the Chicago metropolitan area and quantify various operational metrics including energy costs and vehicle miles traveled. We find that by deploying roughly 20% of range -extended vehicles with a modest all-electric range of 33 miles, parcel distributors can save energy costs by up to 17% while incurring less than 0.5% increase in vehicle miles traveled. Increasing the range to 60 miles further reduces costs by only 4%, which can alternatively be achieved by decreasing the average service time by 1 minute or increasing driver working time by 1 hour. In conclusion, our study reveals several key areas of improvement on which vehicle manufacturers, distributors, and policy makers can focus their attention.

33 ADVANCED PROPULSION SYSTEMS↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Roadmap for Advancement of Low-Voltage Secondary Distribution Network Protection

Downtown low-voltage (LV) distribution networks are generally protected with network protectors that detect faults by restricting reverse power flow out of the network. This creates protection challenges for protecting the system as new smart grid technologies and distributed generation are installed. This report summarizes well-established methods for the control and protection of LV secondary network systems and spot networks, including operating features of network relays. Some current challenges and findings are presented from interviews with three utilities, PHI PEPCO, Oncor Energy Delivery, and Consolidated Edison Company of New York. Opportunities for technical exploration are presented with an assessment of the importance or value and the difficulty or cost. Finally, this leads to some recommendations for research to improve protection in secondary networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Systems Integration Facility (ESIF): World-Class Systems Integration Capabilities and Research

The Energy Systems Integration Facility (ESIF), located at the National Renewable Energy Laboratory (NREL) South Table Mountain campus, is a world-renowned user facility for research and development of modern, advanced, and clean energy technologies. ESIF is distinguished by its continuously evolving, highly integrated systems that span throughout the building, connecting research capabilities across multiple laboratories and test areas. The primary ESIF research systems include: [1] data, cyber, and control networks, [2] research electrical distribution buses (REDB), [3] thermal integration infrastructure, and [4] hydrogen systems. The data, cyber, and control networks provide monitoring, control, communication, automation, visualization, and time series data storage and tagging capabilities for research projects and ESIF systems, including facility safety functions. The REDB system consists of four dedicated AC and DC electrical power networks that can connect devices located across the facility through versatile, automatic circuit configuration to support complex power electronics experiments up to the megawatt-scale. The thermal integration infrastructure consists of three temperature-conditioned water loops that provide heating and cooling interfaces and capabilities for thermal energy research. The hydrogen systems provide megawatt-scale hydrogen production, drying, compression, high-pressure storage, and delivery to laboratory end uses, including hydrogen fuel cell vehicle fueling. The ESIF research systems interconnect and extend throughout the various lab areas of the facility to create elaborate networks composed of diverse technologies for cutting-edge research. The ESIF capabilities are operated and stewarded by the ESIF Research Operations group, who also actively upgrade and advance the systems to ensure they remain ahead of anticipated research - enabling the success of many pioneering energy integration projects. The poster, created by members of the ESIF Research Operations team, highlights and summarizes the four core integrated systems at ESIF. The poster was first presented at the internal NREL Energize Forum on May 13th, 2024, and received the "Best Poster" award.

capabilities↗

nnopf

SAND2026-19433O The nnopf tool addresses the optimal power flow (OPF) problem by optimizing electricity delivery from generating plants to consumers. At the same time, it minimizes costs and adheres to power grid constraints. While traditional methods for solving OPF can be computationally intensive, the tool mitigates this challenge by training neural networks on power grids to predict optimal solutions for the OPF problem. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Hart, William [Sandia National Lab. (SNL-CA), Live↗

Net-zero Microgrid Program Report: Microrred de la Montaña Feasibility Study (Executive Summary Extended)

This feasibility study provides the technical and economic rationale for the Microrred de la Montaña as a viable solution for supplying reliable and resilient electricity to an underserved region in Puerto Rico – a region that is the first to be disconnected from the grid and the last to be restored, enduring months long outages. It begins the process of the development of the microgrid through conceptual design, engineering, detailed electrical design, implementation, and operation. The Microrred de la Montaña is organized under the governance of the Cooperativa Hidroeléctrica de la Montaña (Cooperativa) which has legal status as a cooperative and power provider under the laws of Puerto Rico. The members are the municipalities of Adjuntas, Jayuya, Lares and Utuado with a combined population of 90,000. These municipalities are in central Puerto Rico – a mountainous region that is extremely vulnerable to weather events and excessive, long-duration power outages and are among the poorest and most disadvantaged regions in Puerto Rico. Funding from external sources is necessary to acquire the resources for a resilient power delivery system. Regulatory support is necessary to establish operational relationships with the incumbent power providers. The Microrred de la Montaña is envisioned as a resilient microgrid that manages distributed energy resources – local solar, storage, and hydroelectricity over an upgraded distribution network within the boundaries of four municipalities. This feasibility study provides the results of an extensive techno-economic analysis to form a sound basis for decision-making by community leaders, their constituents, funding and investment agencies, and regulators to realize the benefits that are achievable by fully implementing the design and planning recommended for the Microrred de la Montaña.

13 HYDRO ENERGY↗

Preliminary Design of Nuclear Reactor Heat Delivery Systems: Integration with Reference Oil Refinery, Methanol Synthesis, and Hydrogen Production

The Department of Energy’s (DOE) Integrated Energy Systems (IES) program is generating comprehensive analyses validating the opportunity for using nuclear energy in a variety of applications including future clean grids, providing heat for direct use, and providing heat to help reduce emissions in chemical commodities. This work focuses on the preliminary designs of thermal delivery systems that can integrate heat produced from a nuclear core to industrial processes. The key research question that needs to be answered is: what is the prospective method for integrating nuclear generated heat energy into non-electric applications that can facilitate combined heat and power operations by advanced nuclear reactor systems? This research is a composition of case studies showing preliminary conceptual designs for thermal delivery systems integrating advanced nuclear systems with a few industrial systems including high temperature steam electrolysis, a reference oil refinery, and potential future methanol systems that supplant some natural gas use with nuclear energy. Piping and instrumentation diagrams have been developed to show the conceptual integration of nuclear systems with representative industrial systems. Different features of the configurations are dependent on the specific integration requirements including energy source conditions, demand quantity, and require energy application conditions. Design concepts are validated using thermodynamic balance calculations to verify system performance including calculating system losses during transport. Key components: pumps and compressors, heat exchangers, and network piping are reported with key design information and sizing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗