Search NASASearch

SEARCH · Search NASA

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Towards the GEOSAT Follow-On Precise Orbit Determination Goals of High Accuracy and Near-Real-Time Processing

The US Navy's GEOSAT Follow-On spacecraft (GFO) primary mission objective is to map the oceans using a radar altimeter. Satellite laser ranging data, especially in combination with altimeter crossover data, offer the only means of determining high-quality precise orbits. Two tuned gravity models, PGS7727 and PGS7777b, were created at NASA GSFC for GFO that reduce the predicted radial orbit through degree 70 to 13.7 and 10.0 mm. A macromodel was developed to model the nonconservative forces and the SLR spacecraft measurement offset was adjusted to remove a mean bias. Using these improved models, satellite-ranging data, altimeter crossover data, and Doppler data are used to compute both daily medium precision orbits with a latency of less than 24 hours. Final precise orbits are also computed using these tracking data and exported with a latency of three to four weeks to NOAA for use on the GFO Geophysical Data Records (GDR s). The estimated orbit precision of the daily orbits is between 10 and 20 cm, whereas the precise orbits have a precision of 5 cm.

Lemoine, Frank G.

Platform Precision Autopilot Overview and Flight Test Results

The Platform Precision Autopilot is an instrument landing system interfaced autopilot system, developed to enable an aircraft to repeatedly fly nearly the same trajectory hours, days, or weeks later. The Platform Precision Autopilot uses a novel design to interface with a NASA Gulfstream III jet by imitating the output of an instrument landing system approach. This technique minimizes, as much as possible, modifications to the baseline Gulfstream III jet and retains the safety features of the aircraft autopilot. The Platform Precision Autopilot requirement is to fly within a 5-m (16.4-ft) radius tube for distances to 200 km (108 nmi) in the presence of light turbulence for at least 90 percent of the time. This capability allows precise repeat-pass interferometry for the Uninhabited Aerial Vehicle Synthetic Aperture Radar program, whose primary objective is to develop a miniaturized, polarimetric, L-band synthetic aperture radar. Precise navigation is achieved using an accurate differential global positioning system developed by the Jet Propulsion Laboratory. Flight-testing has demonstrated the ability of the Platform Precision Autopilot to control the aircraft within the specified tolerance greater than 90 percent of the time in the presence of aircraft system noise and nonlinearities, constant pilot throttle adjustments, and light turbulence.

Lin, V.

Platform Precision Autopilot Overview and Mission Performance

The Platform Precision Autopilot is an instrument landing system-interfaced autopilot system, developed to enable an aircraft to repeatedly fly nearly the same trajectory hours, days, or weeks later. The Platform Precision Autopilot uses a novel design to interface with a NASA Gulfstream III jet by imitating the output of an instrument landing system approach. This technique minimizes, as much as possible, modifications to the baseline Gulfstream III jet and retains the safety features of the aircraft autopilot. The Platform Precision Autopilot requirement is to fly within a 5-m (16.4-ft) radius tube for distances to 200 km (108 nmi) in the presence of light turbulence for at least 90 percent of the time. This capability allows precise repeat-pass interferometry for the Unmanned Aerial Vehicle Synthetic Aperture Radar program, whose primary objective is to develop a miniaturized, polarimetric, L-band synthetic aperture radar. Precise navigation is achieved using an accurate differential global positioning system developed by the Jet Propulsion Laboratory. Flight-testing has demonstrated the ability of the Platform Precision Autopilot to control the aircraft within the specified tolerance greater than 90 percent of the time in the presence of aircraft system noise and nonlinearities, constant pilot throttle adjustments, and light turbulence.

Strovers, Brian K.

Apparatus for Precise Indium-Bump Bonding of Microchips

An improved apparatus has been designed and built for use in precise positioning and pressing of a microchip onto a substrate (which could, optionally, be another microchip) for the purpose of indium-bump bonding. The apparatus (see figure) includes the following: A stereomicroscope, A stage for precise positioning of the microchip in rotation angle (theta) about the nominally vertical pressing axis and in translation along two nominally horizontal coordinate axes (x and y), and An actuator system that causes a bonding tip to press the microchip against the substrate with a precisely controlled force. In operation, the microscope and the stage are used to position the microchip under the bonding tip and to align the indium bumps on the chip and the substrate, then the actuator system is used to apply a prescribed bonding force for a prescribed time. The improved apparatus supplants a partly similar prior apparatus that operated with less precision and repeatability, producing inconsistent and unreliable bonds. Results of the use of the prior apparatus included broken microchips, uneven bonds, and bonds characterized, variously, by overcompression or undercompression. In that apparatus, the bonding force was generated and controlled by use of a micrometer head positioned over the center of a spring-loaded scale, and the force was applied to the microchip via the scale, which was equipped for digital readout of the force. The inconsistency of results was attributed to the following causes: It was not possible to control the bonding force with sufficient precision or repeatability. Particularly troublesome was the inability to control the force at levels less than the weight of 150 g. Excessive compliance in the spring-loaded scale, combined with deviations from parallelarity of the substrate and bonding-tip surfaces, gave rise to nonuniformity in the pressure applied to the microchip, thereby generating excessive stresses and deformations in the microchip. In the improved apparatus, the bonding tip and the components that hold the substrate and the microchip are more rigid and precise than in the prior apparatus, so as to ensure less deviation from parallelarity of the bonding-tip and substrate surfaces, thereby ensuring more nearly uniform distribution of bonding force over the area of the microchip. The bonding force is now applied through, and measured by, a load cell that makes it possible to exert finer control over the force. The force can be set at any value between 0 and the weight of 800 g in increments of 0.2 g.

Wild, Larry

Precision in Assembled Discrete Lattice Space Structures for Next-Generation ISAM Applications

Robust autonomous robotic assembly of large-scale space structures has been a long-term and challenging goal to enable higher quality in-space communication and science instrumentation. For optical observatory support structures and antenna structures, the challenge is the strict dimensional precision requirements (generally RMS surface error) driven by the operational radiation wavelength. Early theoretical work in the area linked RMS surface error of a reflector support truss plate to the natural passive dynamic mode frequencies of the structure, as well as to the error distribution in dimensions of constituent structural elements. Prior robotic truss assembly demonstrations focused on designing ultra-high precision structural elements, joints, and robotic actuators. Recently, an alternative space structure assembly strategy based on a programmable matter approach (NASA ARMADAS) was demonstrated. This approach uses lattice building blocks (voxels) that are reversibly, mechanically joined into a bulk lattice structure by robots that locomote in and on the structure itself. Such a system can achieve high-level autonomy with low computation, robustly assemble utilizing inexpensive and imprecise robots, and efficiently build structures several orders of magnitude larger than the assembly robots. However, for instrumentation support structure applications, the resulting precision of these building block-based lattice structures is not well studied. Since they are demonstrated with many more assembly units than prior art trusses, it is unclear whether the same precision design approaches apply. In this work, we study in simulation the effects of voxel geometry, error in distribution, assembly resolution (module size), and assembly geometry on the error of both beam and plate lattice structures. While average RMS error of a plate increases with plate size, increasing plate thickness quickly collapses RMS error towards a limit that is on the order of the error of the constituent parts. We validate our models against previously published precision measurements of built systems. Results from this study will guide manufacturing precision requirements, as well as designs, for future robotically assembled structural applications and establish feasibility for different applications.

Christine E Gregg

A GPU Accelerated Mixed‐Precision Finite Difference Informed Random Walker (FDiRW) Solver for Strongly Inhomogeneous Diffusion Problems

In nature, many complex multi‐physics coupling problems exhibit significant diffusivity inhomogeneity, where one process occurs several orders of magnitude faster than others temporally. Simulating rapid diffusion alongside slower processes demands intensive computational resources due to the necessity for small time steps. To address these computational challenges, we have developed an efficient numerical solver named Finite Difference informed Random Walker (FDiRW). In this study, we propose a GPU‐accelerated, mixed‐precision configuration for the FDiRW solver to maximize efficiency through GPU multi‐threaded parallel computation and lower precision computation. Numerical evaluation results reveal that the proposed GPU‐accelerated mixed‐precision FDiRW solver can achieve a 117× speedup over the CPU baseline, while an additional 1.75× speedup is achieved by employing lower precision GPU computation. Notably, for large model sizes, the GPU‐accelerated mixed‐precision FDiRW solver demonstrates strong scaling with the number of nodes used in simulation. When simulating radionuclide absorption processes by porous wasteform particles with a medium‐sized model of 192 × 192 × 192, this approach reduces the total computational time to 10 min, enabling the simulation of larger systems with strongly inhomogeneous diffusivity.

97 MATHEMATICS AND COMPUTING

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85

High-precision measurement of the W boson mass with the CMS experiment

In the standard model of particle physics, the masses of the W and Z bosons, the carriers of the weak interaction, are uniquely related. A precise determination of their masses is important because quantum loops of heavy, undiscovered particles could modify this relationship. Although the Z mass is known to the remarkable precision of 22 parts per million (2.0 MeV), the W mass is known much less precisely. A global fit to measured electroweak observables predicts the W mass with 6 MeV uncertainty [1$-$3]. Reaching a comparable experimental precision would be a sensitive and fundamental test of the standard model, made even more urgent by a recent challenge to the global fit prediction by a measurement from the CDF Collaboration at the Fermilab Tevatron collider [4]. Here we report the measurement of the W mass by the CMS Collaboration at the CERN LHC, based on a large data sample of $W \to \mu \nu$ events collected in 2016 at the proton-proton collision energy of 13 TeV. The measurement exploits a high-granularity maximum likelihood fit to the kinematic properties of muons produced in W decays. By combining an accurate determination of experimental effects with marked in situ constraints of theoretical inputs, we reach a precise measurement of the W mass, of 80 360.2 $\pm$ 9.9 MeV, in agreement with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics

Quantifying the impact of precision errors on quantum approximate optimization algorithms

The quantum approximate optimization algorithm (QAOA) is a hybrid quantum-classical algorithm that seeks to achieve approximate solutions to optimization problems by iteratively alternating between intervals of controlled quantum evolution. Here, we examine the effect of analog precision errors on QAOA performance from the perspective of both algorithmic training and performance guarantees. Leveraging cumulant expansions, we recast the faulty QAOA as a control problem in which precision errors are expressed as multiplicative control noise and derive bounds on the performance of QAOA. We show using both analytical techniques and numerical simulations that fixed precision implementations of QAOA circuits are subject to an exponential degradation in performance dependent upon the number of optimal QAOA layers and magnitude of the precision error. Despite this significant reduction, we show that it is possible to mitigate precision errors in QAOA via digitization of the variational parameters at the cost of increasing circuit depth.

quantum algorithms

Precision Agriculture using Networks of Degradable Analytical Sensors (PANDAS) (Final Technical Report)

Precision agriculture, where sensing of soil, environment and crop conditions are used to precisely synchronize inputs (such as water and fertilizer) to crop needs enhances input use efficiency. This can improve yields and farm profitability while mitigating environmental losses, improving soil carbon content and substantially decreasing energy use for food, feed and fuel crops. Unfortunately, farmers are not yet able to harness the full potential of these management technologies as there is a lack of available management information, and there is therefore a need for sensors that are able to economically measure spatio-temporal variability in soil and crop properties of extremely heterogeneous farm fields precisely at high resolution and at low cost. Real-time, in-situ monitoring of agricultural soil conditions is today carried out using devices that limit the total number of nodes that can be used economically to typically one per acre or less. Higher spatio-temporal resolution sensing would enable more precise agricultural input optimization, with significant benefits to the farmer and the environment. In order to address this issue, this project focused on developing additively manufactured, biodegradable, soil sensors with predicted costs of < $\$$1 per unit to monitor crop inputs (such as water and fertilizer) that predictably, harmlessly degrade away into the soil when no longer needed. These sensor nodes should be easy to place, accurately and continuously monitor soil and crop conditions for an entire season, be read remotely using existing farm equipment, require no ongoing maintenance, not impede farm operations and produce no persistent waste. This approach could enable a >100× increase in information density over current solutions for precision farming of row and other crops, and lead to significant reductions in input energy use and provide increased yield for biofuel crops. Over the course of this project the team at the University of Colorado Boulder, University of California Berkeley, and Colorado State University/Kansas State University investigated a wide range of printable biodegradable electronic materials and sensor designs for determining soil moisture and soil nitrate concentration. These efforts expanded the available materials set for printed soil degradable electronic materials, particularly for conductors, enabling high conductivity and stability. Printed soil moisture and nitrate sensors with suitable sensitivity and selectivity were developed and characterized. Low power and passive wireless electronic systems were integrated with the soil sensors, and testing was carried out with completed sensors to understand their functionality under agricultural conditions. Additionally, other sensor types enabled by the biodegradable materials set created during this project, such as soil microbial activity sensors, were also developed and demonstrated. Project outputs include 10 peer reviewed publications, 4 patent applications, 21 technical presentations, 3 PhD thesis, 10 media reports, 8 additional grants worth over $\$$6M, and the formation of 3 start-up companies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Precision of ENDF and ENDL Formatted Data Files

The purpose is to ensure that today’s processing codes produced output to meet today’s accuracy needs. Since 1958 ENDL and about 1965 ENDF have each used a text format to define nuclear and atomic data in 11 columns for each data field. When these formats originated this was judged to be adequate to reproduce the accuracy of data at the time and to meet the needs of our applications. When these formats originated the dominant computer language of the day was FORTRAN and if written using an E11.4 format it would include only 4 or 5 digits of precision, e.g., 0.1234E-03 or 1.2345E-02, varying from one computer/system to another the result was not even unique. In the case of ENDF the 4 digit precision was not even adequate to uniquely define the atomic weight of the target, e.g., U238 = 92238 = 0.9224E+5 = WRONG! From its inceptions the ENDF format had a precision problem. One of my first tasks when in 1967 fresh out of graduate school I joined what later became the National Nuclear Data Center (NNDC), was to address this precision problem. By working with ENDF producers and users throughout the U.S. we verified, 1) E or D is not required to define FORTRAN readable numbers, e.g., E+4 or +4 are both o.k. 2) With ENDF energy eV and cross section in barns, 2 digit exponents are almost never required. 3) Since energy is never negative we could use the first of the 11 columns for a digit. Knowing this allowed us to produce ENDF/B-II to 6 or 7 digit precision, e.g., blank, decimal point, 2 or 3 digit exponent, e.g., ^1.23456-12 or ^1.234567-3. Below is an example of the actual ENDF/B-II data released. Note, the date 1970 and the atomic weight, ZA, uniquely defined to 6-digit accuracy, ^9.22350+ 4.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Extended precision software packages

A description of three extended precision packages is presented along with three small conversion subroutines which can be used in conjunction with the extended precision packages. These extended packages represent software packages written in FORTRAN 4. They contain normalized or unnormalized floating point arithmetic with symmetric rounding and arbitrary mantissa lengths, and normalized floating point interval arithmetic with appropriate rounding. The purpose of an extended precision package is to enable the user to use and manipulate numbers with large decimal places as well as those with small decimal places where precision beyond double precision is required.

Phillips, E. J.

A mathematical basis for the design and design optimization of adaptive trusses in precision control

A mathematical basis for the optimal design of adaptive trusses to be used in supporting precision equipment is provided. The general theory of adaptive structures is introduced, and the global optimization problem of placing a limited number, q, of actuators, so as to maximally achieve precision control and provide prestress, is stated. Two serialized optimization problems, namely, optimal actuator placement for prestress and optimal actuator placement for precision control, are addressed. In the case of prestressing, the computation of a 'desired' prestress is discussed, the interaction between actuators and redundants in conveying the prestress is shown in its mathematical form, and a methodology for arriving at the optimal placement of actuators and additional redundants is discussed. With regard to precision control, an optimal placement scheme (for q actuators) for maximum 'authority' over the precision points is suggested. The results of the two serialized optimization problems are combined to give a suboptimal solution to the global optimization problem. A method for improving this suboptimal actuator placement scheme by iteration is presented.

Das, S. K.

Engine Performance of Precision-forged, Electropolished and Machined Blades of Nimonic 80 and 80A Alloys

An investigation was conducted to determine the effect of electropolishing precision-forged blades and of machining blades from oversize forgings on the engine performance of Nimonic 80 and Nimonic 80A turbine blades. These blades, along with precision-forged blades, were run in a J33-9 turbojet engine. The tests resulted in the following conclusions: (1) Electropolishing of precision-forged blades did not improve engine life relative to the life of nonelectropolished blades. (2) Machining blades from oversize forgings did not improve the engine life of precision-forged blades. (3) The precision-forging and heat-treating practice used in fabricating the blades investigated was such that the surface roughness and oxide penetration was so slight, approximately 0.0005 inch in depth, as to preclude any benefits derived from surface removal by electropolishing or machining.

Sikora, Paul F

Precision orbit determination of altimetric satellites

The ability to determine accurate global sea level variations is important to both detection and understanding of changes in climate patterns. Sea level variability occurs over a wide spectrum of temporal and spatial scales, and precise global measurements are only recently possible with the advent of spaceborne satellite radar altimetry missions. One of the inherent requirements for accurate determination of absolute sea surface topography is that the altimetric satellite orbits be computed with sub-decimeter accuracy within a well defined terrestrial reference frame. SLR tracking in support of precision orbit determination of altimetric satellites is significant. Recent examples are the use of SLR as the primary tracking systems for TOPEX/Poseidon and for ERS-1 precision orbit determination. The current radial orbit accuracy for TOPEX/Poseidon is estimated to be around 3-4 cm, with geographically correlated orbit errors around 2 cm. The significance of the SLR tracking system is its ability to allow altimetric satellites to obtain absolute sea level measurements and thereby provide a link to other altimetry measurement systems for long-term sea level studies. SLR tracking allows the production of precise orbits which are well centered in an accurate terrestrial reference frame. With proper calibration of the radar altimeter, these precise orbits, along with the altimeter measurements, provide long term absolute sea level measurements. The U.S. Navy's Geosat mission is equipped with only Doppler beacons and lacks laser retroreflectors. However, its orbits, and even the Geosat orbits computed using the available full 40-station Tranet tracking network, yield orbits with significant north-south shifts with respect to the IERS terrestrial reference frame. The resulting Geosat sea surface topography will be tilted accordingly, making interpretation of long-term sea level variability studies difficult.

Shum, C. K.

Precision orbit determination using TOPEX/Poseidon TDRSS observations

The TOPEX/Poseidon (T/P) Mission carries a variety of packages to support experimental, precision and operational orbit determination. Included are a GPS transponder, laser retro-reflectors, the French-developed Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) Doppler tracking system and a Tracking Data Relay Satellite System (TDRSS) transponder. Presently, TDRSS tracking is used for operational orbit support and is processed with force and measurement modeling consistent with this purpose. However, the low noise and extensive geographical coverage of the TDRSS/TOPEX data allows an assessment of TDRSS Precision Orbit Determination (POD) capabilities by comparison to the T/P precision orbit determination. The Geodynamics (GEODYN) Orbit Determination System is used to process laser and DORIS data to produce the precision orbits for the T/P Project. GEODYN has been modified recently to support the TDRSS observations. TDRSS data analysis can now benefit from the extensive force modeling and reference frame stability needed to meet the orbit determination (OD) goals of the T/P Mission. This analysis has concentrated on the strongest of the TDRSS measurement types, its two-way average range rate. Both the TDRSS and T/P orbits have been assessed in combination with the global satellite laser ranging (SLR) data and by themselves. These results indicate that significant improvement in the TDRSS ephemerides is obtained when the T/P orbit is well determined by SLR, and the TDRSS/TOPEX Doppler link is used to position TDRSS. Meter-level TDRSS positioning uncertainty is achieved using this approach. When the TDRSS orbit location is provided by this approach, the two-way range rate from a single TDRSS (i.e. West only) can provide T/P orbits with sub-meter radial accuracies and two meter RMS total position agreement with SLR defined orbits. These preliminary results indicate improved modeling of the TDRSS measurement through the elimination of heretofore neglected effects like the motion of the T/P TDRSS antenna and improved modeling of ionospheric and atmospheric refractive effects, and the inclusion of TDRSS East in the analysis are warranted. Through these improvements, TDRSS can make a significant contribution to geopotential recovery and precision OD.

Teles, Jerome