Search NASASearch

SEARCH · Search NASA

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Precision in Assembled Discrete Lattice Space Structures for Next-Generation ISAM Applications

Robust autonomous robotic assembly of large-scale space structures has been a long-term and challenging goal to enable higher quality in-space communication and science instrumentation. For optical observatory support structures and antenna structures, the challenge is the strict dimensional precision requirements (generally RMS surface error) driven by the operational radiation wavelength. Early theoretical work in the area linked RMS surface error of a reflector support truss plate to the natural passive dynamic mode frequencies of the structure, as well as to the error distribution in dimensions of constituent structural elements. Prior robotic truss assembly demonstrations focused on designing ultra-high precision structural elements, joints, and robotic actuators. Recently, an alternative space structure assembly strategy based on a programmable matter approach (NASA ARMADAS) was demonstrated. This approach uses lattice building blocks (voxels) that are reversibly, mechanically joined into a bulk lattice structure by robots that locomote in and on the structure itself. Such a system can achieve high-level autonomy with low computation, robustly assemble utilizing inexpensive and imprecise robots, and efficiently build structures several orders of magnitude larger than the assembly robots. However, for instrumentation support structure applications, the resulting precision of these building block-based lattice structures is not well studied. Since they are demonstrated with many more assembly units than prior art trusses, it is unclear whether the same precision design approaches apply. In this work, we study in simulation the effects of voxel geometry, error in distribution, assembly resolution (module size), and assembly geometry on the error of both beam and plate lattice structures. While average RMS error of a plate increases with plate size, increasing plate thickness quickly collapses RMS error towards a limit that is on the order of the error of the constituent parts. We validate our models against previously published precision measurements of built systems. Results from this study will guide manufacturing precision requirements, as well as designs, for future robotically assembled structural applications and establish feasibility for different applications.

Christine E Gregg

Extended precision software packages

A description of three extended precision packages is presented along with three small conversion subroutines which can be used in conjunction with the extended precision packages. These extended packages represent software packages written in FORTRAN 4. They contain normalized or unnormalized floating point arithmetic with symmetric rounding and arbitrary mantissa lengths, and normalized floating point interval arithmetic with appropriate rounding. The purpose of an extended precision package is to enable the user to use and manipulate numbers with large decimal places as well as those with small decimal places where precision beyond double precision is required.

Phillips, E. J.

A mathematical basis for the design and design optimization of adaptive trusses in precision control

A mathematical basis for the optimal design of adaptive trusses to be used in supporting precision equipment is provided. The general theory of adaptive structures is introduced, and the global optimization problem of placing a limited number, q, of actuators, so as to maximally achieve precision control and provide prestress, is stated. Two serialized optimization problems, namely, optimal actuator placement for prestress and optimal actuator placement for precision control, are addressed. In the case of prestressing, the computation of a 'desired' prestress is discussed, the interaction between actuators and redundants in conveying the prestress is shown in its mathematical form, and a methodology for arriving at the optimal placement of actuators and additional redundants is discussed. With regard to precision control, an optimal placement scheme (for q actuators) for maximum 'authority' over the precision points is suggested. The results of the two serialized optimization problems are combined to give a suboptimal solution to the global optimization problem. A method for improving this suboptimal actuator placement scheme by iteration is presented.

Das, S. K.

Engine Performance of Precision-forged, Electropolished and Machined Blades of Nimonic 80 and 80A Alloys

An investigation was conducted to determine the effect of electropolishing precision-forged blades and of machining blades from oversize forgings on the engine performance of Nimonic 80 and Nimonic 80A turbine blades. These blades, along with precision-forged blades, were run in a J33-9 turbojet engine. The tests resulted in the following conclusions: (1) Electropolishing of precision-forged blades did not improve engine life relative to the life of nonelectropolished blades. (2) Machining blades from oversize forgings did not improve the engine life of precision-forged blades. (3) The precision-forging and heat-treating practice used in fabricating the blades investigated was such that the surface roughness and oxide penetration was so slight, approximately 0.0005 inch in depth, as to preclude any benefits derived from surface removal by electropolishing or machining.

Sikora, Paul F

Precision orbit determination of altimetric satellites

The ability to determine accurate global sea level variations is important to both detection and understanding of changes in climate patterns. Sea level variability occurs over a wide spectrum of temporal and spatial scales, and precise global measurements are only recently possible with the advent of spaceborne satellite radar altimetry missions. One of the inherent requirements for accurate determination of absolute sea surface topography is that the altimetric satellite orbits be computed with sub-decimeter accuracy within a well defined terrestrial reference frame. SLR tracking in support of precision orbit determination of altimetric satellites is significant. Recent examples are the use of SLR as the primary tracking systems for TOPEX/Poseidon and for ERS-1 precision orbit determination. The current radial orbit accuracy for TOPEX/Poseidon is estimated to be around 3-4 cm, with geographically correlated orbit errors around 2 cm. The significance of the SLR tracking system is its ability to allow altimetric satellites to obtain absolute sea level measurements and thereby provide a link to other altimetry measurement systems for long-term sea level studies. SLR tracking allows the production of precise orbits which are well centered in an accurate terrestrial reference frame. With proper calibration of the radar altimeter, these precise orbits, along with the altimeter measurements, provide long term absolute sea level measurements. The U.S. Navy's Geosat mission is equipped with only Doppler beacons and lacks laser retroreflectors. However, its orbits, and even the Geosat orbits computed using the available full 40-station Tranet tracking network, yield orbits with significant north-south shifts with respect to the IERS terrestrial reference frame. The resulting Geosat sea surface topography will be tilted accordingly, making interpretation of long-term sea level variability studies difficult.

Shum, C. K.

Precision orbit determination using TOPEX/Poseidon TDRSS observations

The TOPEX/Poseidon (T/P) Mission carries a variety of packages to support experimental, precision and operational orbit determination. Included are a GPS transponder, laser retro-reflectors, the French-developed Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) Doppler tracking system and a Tracking Data Relay Satellite System (TDRSS) transponder. Presently, TDRSS tracking is used for operational orbit support and is processed with force and measurement modeling consistent with this purpose. However, the low noise and extensive geographical coverage of the TDRSS/TOPEX data allows an assessment of TDRSS Precision Orbit Determination (POD) capabilities by comparison to the T/P precision orbit determination. The Geodynamics (GEODYN) Orbit Determination System is used to process laser and DORIS data to produce the precision orbits for the T/P Project. GEODYN has been modified recently to support the TDRSS observations. TDRSS data analysis can now benefit from the extensive force modeling and reference frame stability needed to meet the orbit determination (OD) goals of the T/P Mission. This analysis has concentrated on the strongest of the TDRSS measurement types, its two-way average range rate. Both the TDRSS and T/P orbits have been assessed in combination with the global satellite laser ranging (SLR) data and by themselves. These results indicate that significant improvement in the TDRSS ephemerides is obtained when the T/P orbit is well determined by SLR, and the TDRSS/TOPEX Doppler link is used to position TDRSS. Meter-level TDRSS positioning uncertainty is achieved using this approach. When the TDRSS orbit location is provided by this approach, the two-way range rate from a single TDRSS (i.e. West only) can provide T/P orbits with sub-meter radial accuracies and two meter RMS total position agreement with SLR defined orbits. These preliminary results indicate improved modeling of the TDRSS measurement through the elimination of heretofore neglected effects like the motion of the T/P TDRSS antenna and improved modeling of ionospheric and atmospheric refractive effects, and the inclusion of TDRSS East in the analysis are warranted. Through these improvements, TDRSS can make a significant contribution to geopotential recovery and precision OD.

Teles, Jerome

Astrophysical Adaptation of Points, the Precision Optical Interferometer in Space

POINTS (Precision Optical INTerferometer in Space) would perform microarcsecond optical astrometric measurements from space, yielding submicroarcsecond astrometric results from the mission. It comprises a pair of independent Michelson stellar interferometers and a laser metrology system that measures both the critical starlight paths and the angle between the baselines. The instrument has two baselines of 2 m, each with two subapertures of 35 cm; by articulating the angle between the baselines, it observes targets separated by 87 to 93 deg. POINTS does global astrometry, i.e., it measures widely separated targets, which yields closure calibration, numerous bright reference stars, and absolute parallax. Simplicity, stability, and the mitigation of systematic error are the central design themes. The instrument has only three moving-part mechanisms, and only one of these must move with sub-milliradian precision; the other two can tolerate a precision of several tenths of a degree. Optical surfaces preceding the beamsplitter or its fold flat are interferometrically critical; on each side of the interferometer, there are only three such. Thus, light loss and wavefront distortion are minimized. POINTS represents a minimalistic design developed ab initio for space. Since it is intended for astrometry, and therefore does not require the u-v-plane coverage of an imaging, instrument, each interferometer need have only two subapertures. The design relies on articulation of the angle between the interferometers and body pointing to select targets; the observations are restricted to the 'instrument plane.' That plane, which is fixed in the pointed instrument, is defined by the sensitive direction for the two interferometers. Thus, there is no need for siderostats and moving delay lines, which would have added many precision mechanisms with rolling and sliding parts that would be required to function throughout the mission. Further, there is no need for a third interferometer, as is required when out-of-plane observations are made. An instrument for astrometry, unlike those for imaging, can be compact and yet scientifically productive. The POINTS instrument is compact and therefore requires no deployment of precision structures, has no low-frequency (i.e., under 100 Hz) vibration modes, and is relatively easy to control thermally. Because of its small size and mass, it is easily and quickly repointed between observations. Further, because of the low mass, it can be economically launched into high Earth orbit which, in conjunction with a solar shield, yields nearly unrestricted sky coverage and a stable thermal environment.

Reasenberg, Robert D.

Effect of Correlated Precision Errors on Uncertainty of a Subsonic Venturi Calibration

An uncertainty analysis performed in conjunction with the calibration of a subsonic venturi for use in a turbine test facility produced some unanticipated results that may have a significant impact in a variety of test situations. Precision uncertainty estimates using the preferred propagation techniques in the applicable American National Standards Institute/American Society of Mechanical Engineers standards were an order of magnitude larger than precision uncertainty estimates calculated directly from a sample of results (discharge coefficient) obtained at the same experimental set point. The differences were attributable to the effect of correlated precision errors, which previously have been considered negligible. An analysis explaining this phenomenon is presented. The article is not meant to document the venturi calibration, but rather to give a real example of results where correlated precision terms are important. The significance of the correlated precision terms could apply to many test situations.

Hudson, S. T.

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Done Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift, The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values ( < 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Bone Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift. The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values (less than 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher

An Astronomical Test of CCD Photometric Precision

Ground-based differential photometry is limited to a precision of order 10(exp -3) because of atmospheric effects. A space-based photometer should be limited only by the inherent instrument precision and shot noise. Laboratory tests have shown that a precision of order 10-5 is achievable with commercially available charged coupled devices (CCDs). We have proposed to take this one step further by performing measurements at a telescope using a Wollaston prism as a beam splitter First-order atmospheric effects (e.g., extinction) will appear to be identical in the two images of each star formed by the prism and will be removed in the data analysis. This arrangement can determine the precision that is achievable under the influence of second-order atmospheric effects (e.g., variable point-spread function (PSF) from seeing). These telescopic observations will thus provide a lower limit to the precision that can be realized by a space-based differential photometer.

Koch, David G.

A Task-Analytic Approach to the Determination of Training Requirements for the Precision Descent

A task-analytic approach was used to evaluate the results from an experiment comparing two training methods for the "Precision Descent," a cockpit procedure designed to complement a new, computer-based air traffic control advisory system by allowing air traffic controllers to assign precise descent trajectories to aircraft. A task model was developed for the procedure using a methodology that represents four different categories of task-related knowledge: (1) ability to determine current flight goals; (2) ability to assess the current flight situation relative to those goals; (3) operational knowledge about flight-related tasks; and (4) knowledge about task selection. This model showed what knowledge experienced pilots already possessed, and how that knowledge was supplemented by training material provided in the two training conditions. All flight crews were given a "Precision Descent Chart" that explained the procedure's clearances and compliance requirements. This information enabled pilots to establish appropriate flight goals for the descent, and to monitor their compliance with those goals. In addition to this chart, half of the crews received a "Precision Descent Bulletin" containing technique recommendations for performing procedure-related tasks. The Bulletin's recommendations supported pilots in task selection and helped clarify the procedure's compliance requirements. Eight type-rated flight crews flew eight Precision Descents in a Boeing 747-400 simulator, with four crews in each of the two training conditions. Both conditions (Chart and Chart-with-Bulletin) relied exclusively on the use of those documents to introduce the procedure. No performance feedback was provided during the experiment. Preliminary result show better procedure compliance and higher acceptability ratings from flight crews in the Chart-with-Bulletin condition. These crews performed flight-related tasks less efficiently, however, using the simpler but less efficient methods suggested in the Bulletin. When a more efficient method was recognized, these crews tended to use the more efficient method in addition to the Bulletin's recommendation, instead of replacing it.

Smith, Nancy

Taking the Measure of the Universe : Precision Astrometry with SIM PlanetQuest

Precision astrometry at microarcsecond accuracy has application to a wide range of astrophysical problems. This paper is a study of the science questions that can be addressed using an instrument with flexible scheduling that delivers parallaxes at about 4 microarcsec (microns)as) on targets as faint as V = 20, and differential accuracy of 0.6 (microns)as on bright targets. The science topics are drawn primarily from the Team Key Projects, selected in 2000, for the Space Interferometry Mission PlanetQuest (SIM PlanetQuest). We use the capabilities of this mission to illustrate the importance of the next level of astrometric precision in modern astrophysics. SIM PlanetQuest is currently in the detailed design phase, having completed in 2005 all of the enabling technologies needed for the flight instrument. It will be the first space-based long baseline Michelson interferometer designed for precision astrometry. SIM will contribute strongly to many astronomical fields including stellar and galactic astrophysics, planetary systems around nearby stars, and the study of quasar and AGN nuclei. Using differential astrometry SIM will search for planets with masses as small as an Earth orbiting in the 'habitable zone' around the nearest stars, and could discover many dozen if Earth-like planets are common. It will characterize the multiple-planet systems that are now known to exist, and it will be able to search for terrestrial planets around all of the candidate target stars in the Terrestrial Planet Finder and Darwin mission lists. It will be capable of detecting planets around young stars, thereby providing insights into how planetary systems are born and how they evolve with time. Precision astrometry allows the measurement of accurate dynamical masses for stars in binary systems. SIM will observe significant numbers of very high- and low-mass stars, providing stellar masses to 1%, the accuracy needed to challenge physical models. Using precision proper motion measurements, SIM will probe the Galactic mass distribution, and through studies of tidal tails, the formation and evolution of the Galactic halo. SIM will contribute to cosmology through improved accuracy of the Hubble Constant. With repeated astrometric measurements of the nuclei of active galaxies, SIM will probe the dynamics of accretion disks around supermassive black holes, and the relativistic jets that emerge from them.

Quasars and Active Galactic Nuclei

Value of Sample Return and High Precision Analyses: Need for A Resource of Compelling Stories, Metaphors and Examples for Public Speakers

There is widespread agreement among planetary scientists that much of what we know about the workings of the solar system comes from accurate, high precision measurements on returned samples. Precision is a function of the number of atoms the instrumentation is able to count. Accuracy depends on the calibration or standardization technique. For Genesis, the solar wind sample return mission, acquiring enough atoms to ensure precise SW measurements and then accurately quantifying those measurements were steps known to be non‐trivial pre‐flight. The difficulty of precise and accurate measurements on returned samples, and why they cannot be made remotely, is not communicated well to the public. In part, this is be-cause "high precision" is abstract and error bars are not very exciting topics. This paper explores ideas for collecting and compiling compelling metaphors and colorful examples as a resource for planetary science public speakers.

Allton, J. H.

NASA SPLICE Project: Development and Testing of Precision Landing GN&C Technologies

NASA's technology advancement needs for entry, descent and landing call for high-precision, high-rate sensors that can improve navigation accuracy and vehicle control performance. Higher landing accuracy is required for any future human lander missions, and likely, for most robotic missions 1,2. Sensors and algorithms that significantly reduce navigation errors and can image the local terrain will enable landing at locations of high scientific interest that would otherwise pose significant risk to the vehicle. The Safe and Precise Landing-Integrated Capabilities Evolution project, or SPLICE, is developing precision landing and hazard avoidance (PL&HA) technologies for NASA and for potential commercial space flight missions. SPLICE technologies include sensors, algorithms, advanced space flight computing capabilities, and simulation tools used to integrate and study guidance, navigation, and control (GN&C) system performance. SPLICE efforts include hardware-in-the-loop (HWIL) simulation testing, ground testing, and flight testing, including reuse of hardware from the CoOperative Blending of Autonomous Landing Technologies (COBALT) suborbital flight-test payload3,4. Two of the precise navigation sensors that are being developed and matured within SPLICE are LiDARs. Since 2006, NASA Langley has been developing a Navigation Doppler LiDAR (NDL) for precise velocity measurements, and SPLICE is building an NDL engineering test unit (ETU) that will be brought up to TRL 6 following environmental and high-speed1,2 testing. NASA Goddard is developing a Hazard Detection LiDAR (HD LiDAR) engineering development unit (EDU) for SPLICE that has relevance to future human and robotic lander missions. The HD LiDAR will be flight test and matured to TRL 5.

Restrepo, Carolina I.

A Simulation Framework for Precision Landing and Hazard Avoidance Technology Assessments

To meet NASA’s challenge to return humans to the Moon in 2024 and establish a sustainable presence in 2028 requires advances in autonomous spacecraft navigation. The Safe and Precise Landing Integrated Capabilities Evolution (SPLICE) project, which leverages previous work at NASA to develop multi-mission precision landing and hazard avoidance technologies, is using a multi-faceted approach to achieve the advanced landing requirements. In addition to increasing the technology readiness level of key sensors and developing high performance space computing, SPLICE uses simulations to determine navigation requirements and evaluate sensor performance. The effort evaluates various precision landing concepts of operations, not only for the lunar human and robotic missions, but also for potential missions to other solar system destinations. This paper summarizes the six degree-of-freedom high fidelity simulation framework, trajectory design methodology, and sensor models being considered for a variety of precision lander missions. Initial results of the navigation sensor performance for a human Mars mission are presented. Finally, trade and sensitivity studies are outlined for future work to fully characterize sensor performance assumptions and modifications required to achieve precision landing and hazard avoidance.

Alicia Dwyer Cianciolo

Green Solvents for Precision Cleaning

Aerospace machinery used in liquid oxygen (LOX) fuel systems must be precision cleaned to achieve a very low level of non-volatile residue (< 1 mg0.1 m2), especially flammable residue. Traditionally chlorofluorocarbons (CFCs) have been used in the precision cleaning of LOX systems, specifically CFC 113 (C2Cl3F3). CFCs have been known to cause the depletion of ozone and in 1987, were banned by the Montreal Protocol due to health, safety and environmental concerns. This has now led to the development of new processes in the precision cleaning of aerospace components. An ideal solvent-replacement is non-flammable, environmentally benign, non-corrosive, inexpensive, effective and evaporates completely, leaving no residue. Highlighted is a green precision cleaning process, which is contaminant removal using supercritical carbon dioxide as the environmentally benign solvent. In this process, the contaminant is dissolved in carbon dioxide, and the parts are recovered at the end of the cleaning process completely dry and ready for use. Typical contaminants of aerospace components include hydrocarbon greases, hydraulic fluids, silicone fluids and greases, fluorocarbon fluids and greases and fingerprint oil. Metallic aerospace components range from small nuts and bolts to much larger parts, such as butterfly valves 18 in diameter. A fluorinated grease, Krytox, is investigated as a model contaminant in these preliminary studies, and aluminum coupons are employed as a model aerospace component. Preliminary studies are presented in which the experimental parameters are optimized for removal of Krytox from aluminum coupons in a stirred-batch process. The experimental conditions investigated are temperature, pressure, exposure time and impeller speed. Temperatures of 308 - 423 K, pressures in the range of 8.3 - 41.4 MPa, exposure times between 5 - 60 min and impeller speeds of 0 - 1000 rpm were investigated. Preliminary results showed up to 86 cleaning efficiency with the moderate processing conditions of 323 K, 13.8 MPa, 30 min and 750 rpm.

solvents

Alternative, Green Processes for the Precision Cleaning of Aerospace Hardware

Precision cleaning is necessary to ensure the proper functioning of aerospace hardware, particularly those systems that come in contact with liquid oxygen or hypergolic fuels. Components that have not been cleaned to the appropriate levels may experience problems ranging from impaired performance to catastrophic failure. Traditionally, this has been achieved using various halogenated solvents. However, as information on the toxicological and/or environmental impacts of each came to light, they were subsequently regulated out of use. The solvent currently used in Kennedy Space Center (KSC) precision cleaning operations is Vertrel MCA. Environmental sampling at KSC indicates that continued use of this or similar solvents may lead to high remediation costs that must be borne by the Program for years to come. In response to this problem, the Green Solvents Project seeks to develop state-of-the-art, green technologies designed to meet KSCs precision cleaning needs.Initially, 23 solvents were identified as potential replacements for the current Vertrel MCA-based process. Highly halogenated solvents were deliberately omitted since historical precedents indicate that as the long-term consequences of these solvents become known, they will eventually be regulated out of practical use, often with significant financial burdens for the user. Three solvent-less cleaning processes (plasma, supercritical carbon dioxide, and carbon dioxide snow) were also chosen since they produce essentially no waste stream. Next, experimental and analytical procedures were developed to compare the relative effectiveness of these solvents and technologies to the current KSC standard of Vertrel MCA. Individually numbered Swagelok fittings were used to represent the hardware in the cleaning process. First, the fittings were cleaned using Vertrel MCA in order to determine their true cleaned mass. Next, the fittings were dipped into stock solutions of five commonly encountered contaminants and were weighed again showing typical contaminant deposition levels of approximately 0.00300g per part. They were then cleaned by the solvent or process being tested and then weighed a third time which allowed for the calculation of the cleaning efficiency of the test solvent or process.Based on preliminary experiments, five solvents (ethanol, isopropanol, acetone, ethyl acetate, and tert-butyl acetate) were down selected for further testing. When coupled with ultrasonic agitation, these solvents removed hydrocarbon contaminants as well as Vertrel MCA and showed improved removal of perfluorinated greases. Supercritical carbon dioxide did an excellent job dissolving each of the five contaminants but did a poor job of removing Teflon particles found in the perfluorinated greases. Plasma cleaning efficiency was found to be dependent on which supply gas was used, exposure time, and gas pressure. Under optimized conditions it was found that breathing air, energized to the plasma phase, was able to remove nearly 100% of the contamination.These findings indicate that alternative cleaning methods are indeed able to achieve precision levels of cleanliness. Currently, our team is working with a commercial cleaning company to get independent verification of our results. We are also evaluating the technical and financial aspects of scaling these processes to a size capable of supporting the future cleaning needs of KSC.

Vertrel MCA