Search NASASearch

SEARCH · Search NASA

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A

Bayesian Inference of Hybrid Star Properties from Future High-precision Measurements of Their Radii

Future high-precision X-ray and gravitational-wave observations of neutron stars (NSs) are expected to constrain NS radii with uncertainties as small as σ ≃ 0.1 km. Such unprecedented precision offers a unique opportunity to extract new information about the nature and equation of state (EOS) of supradense matter in NS cores. Using mock radius data with uncertainties ranging from σ = 1.0 to 0.1 km, together with a flexible meta-model NS EOS that allows for a first-order hadron–quark phase transition, we perform a Bayesian statistical analysis to assess the impact of radius measurements on EOS constraints. We find that high-precision radius measurements, particularly for massive NSs, significantly tighten constraints on the hadron–quark transition density ρ t , the quark matter mass fraction in NS cores, and several parameters characterizing the EOS of supranuclear hadronic matter, although the degree of improvement depends on the assumed prior range of ρ t . In contrast, even with the highest precision considered, NS radii—including those of massive stars—remain largely insensitive to the stiffness of quark matter, independent of the measurement accuracy or the prior range adopted for ρ t .

Neutron stars

Construct design for precise DNA insertion in plants

Precise insertion of DNA sequences at targeted locations in plant genomes is pivotal for synthetic biology, genetics, and crop improvement. Construct design plays a critical role in achieving precise insertions, yet practical guidance remains limited. This review provides an in-depth overview of construct design principles and targeted DNA insertion (knock-in) strategies in plants. We assess the strengths, limitations, and construct requirements of current knock-in methods for specific applications, including short, large, and multifragment insertions. Additionally, we explore the potential of adopting advanced nonplant technologies to enhance knock-in efficiency and precision in plants. This review provides a valuable resource for facilitating the effective application of knock-in technologies to genetically improve crops with minimal off-target effects.

DNA construct

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Exploring isospin symmetry breaking in exotic nuclei: High-precision mass measurement of 23 Si and shell-model calculations of 𝑇 = 5/2 nuclei

Here, we present a high-precision mass measurement of the proton-rich nucleus 23 Si, performed with the LEBIT Penning trap at the Facility for Rare Isotope Beams (FRIB) utilizing the time-of-flight ion cyclotron resonance (TOF-ICR) technique. We determined a mass excess of 23362.9(5.8) keV, which agrees with a recent storage-ring measurement from the experimental Cooler-Storage Ring (CSRe) in Lanzhou but has a factor of 20 improved precision 23 Si is hence the nucleus with the most precisely known mass among all nuclei with an isospin projection of 𝑇 𝑧 = −5/2. We performed shell-model calculations with the USDC and USDCm Hamiltonians to study binding energy differences and Thomas-Ehrmann shifts in mirror systems with an isospin up to 𝑇 = 5/2. Our experimental result and other recently reported masses of neutron-deficient sd-shell nuclei agree well with the theoretical predictions, demonstrating that isospin symmetry breaking in sd-shell nuclei—even at high isospin values—is well described by modern shell-model calculations.

20 ≤ A ≤ 38

The Radical Atom: Mechanosynthetic 3D Printing of an Atomically Precise SPM Tip

This research effort sought to overcome current limitations in scanning probe-based atomic manipulation to enable atomically precise manufacturing (APM). Previous theoretical and experimental works on atom by atom and molecule by molecule fabrication of precise structures are limited to essentially to two-dimensions. APM will enable a paradigm shift in 21st century manufacturing practices in which every single atom in a electronic chip, device or machine can be placed in an exact and predefined position in three-dimensions. By providing a general method for generating reproducible SPM tip structure, this project will drive forward the entire field of atomically precise scanning probe microscopy, opening the door to positional control of nearly arbitrary covalent chemistry. Such control could, for example, be used in applications such as novel 2.5 or 3D microchip fabrication. The creation of a unique manufacturing method through APM has the potential to impact technologies at the theoretical limits of performance, weight, and utility including: solid-state quantum and spintronic computing systems, high efficiency optical antenna, solar power systems, defect engineered materials and extremely efficient catalysts. Although this experiment focused on pick-and-place non-scalable APM, the better understanding of the chemistry is crucial to the eventual goal of scalable APM. To place individual atoms into a specified location is a seminal aspiration of researchers and engineers in the many fields and may have early premium applications in medical devices and microelectronics.

77 NANOSCIENCE AND NANOTECHNOLOGY

Quantitative Electron Beam‐Single Atom Interactions Enabled by Sub‐20‐pm Precision Targeting

The ability to probe and control matter at the picometer scale is essential for advancing quantum and energy technologies. Scanning transmission electron microscopy offers powerful capabilities for materials analysis and modification, but sample damage, drift, and scan distortions hinder single atom analysis and deterministic manipulation. Materials analysis and modification via electron–solid interactions can be transformed by precise delivery of electrons to a specified atomic location, maintaining the beam position despite drift, and minimizing collateral dose. Here a fast, low-dose, sub-20-pm precision electron beam positioning technique is developed, “atomic lock-on,” (ALO), which offers the ability to position the beam on a specific atomic column without previously irradiating that column. This technique is used to lock onto a single selected atomic location to repeatedly measure its weak electron energy loss signal despite sample drift. Moreover, electron beam-matter interactions in single atomic events are measured with μ s time resolution. This enables observation of single-atom dynamics, such as atomic bistability, revealing partially bonded atomic configurations and recapture phenomena. This opens prospects for using electron microscopy for high-precision measurements and deterministic control of matter for quantum technologies.

2D materials

Observable optimization for precision theory: machine learning energy correlators

The practice of collider physics typically involves the marginalization of multi-dimensional collider data to uni-dimensional observables relevant for some physics task. In many cases, such as classification or anomaly detection, the observable can be arbitrarily complicated, such as the output of a neural network. However, for precision measurements, the observable must correspond to something computable systematically beyond the level of current simulation tools. In this work, we demonstrate that precision-theory-compatible observable space exploration can be systematized by using neural simulation-based inference techniques from machine learning. We illustrate this approach by exploring the space of marginalizations of the energy 3-point correlator to optimize sensitivity to the top quark mass. We first learn the energy-weighted probability density from simulation, then search in the space of marginalizations for an optimal triangle shape. Although simulations and machine learning are used in the process of observable optimization, the output is an observable definition which can be then computed to high precision and compared directly to data without any memory of the computations which produced it. We find that the optimal marginalization is isosceles triangles on the sphere with a side ratio approximately $1 : 1 : \sqrt{2}$ (i.e. right triangles) within the set of marginalizations we consider.

Jets and Jet Substructure

Calculation of machine precision second order derivatives using dual-complex numbers

It is well known that both complex and dual numbers can be employed to obtain machine precision first-order derivatives; however, neither, on their own, can compute machine precision 2nd order derivatives. To address this limitation, it is demonstrated in this paper that combined dual-complex numbers can be used to compute machine precision 1st and 2nd order derivatives. The dual-complex approach is simpler than utilizing multicomplex or hyper-dual numbers as existing dual libraries can be used as is or easily augmented to accept complex numbers, and the complexity of developing, integrating, and deploying multicomplex or hyper-dual libraries is avoided. The efficacy of this approach is demonstrated for both univariate and multivariate functions. Finally, source code examples using the Python, Julia, and Mathematica languages are provided as supplemental material.

97 MATHEMATICS AND COMPUTING

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Utilizing Single-Crystalline Transformations for Precise Atom Placement in Multicomponent Cluster-Based Coordination Networks

The assembly of cluster or superatom building-blocks into extended solids has revolutionized materials design, enabling the synthesis of modular semiconductors with well-defined structures and tunable electronic, magnetic or optical properties. This strategy has recently advanced the synthesis of complex metal oxides with multifunctional or emergent behaviors, but precise atom placement of multiple elements with similar chemistries or preferred coordination environments remains a significant challenge. Here, in this study, we present a strategy for synthesizing polyoxometalate (POM)-based coordination networks with up to three different cations in precisely defined positions. Our approach leverages a single-crystal-to-single-crystal (SCSC) transformation in which the spatial placement of cations is governed by their availability at distinct stages of crystallization and transformation. Specifically, [ZP 5 W 30 O 110 ] (15-n)- (Z = Na + , K + , Ca 2+ , Ag + , Bi 3+ , Y 3+ , any Ln 3+ , Th 4+ ) is coordinatively assembled with various bridging metal cations (Y 3+ , any Ln 3+ , Th 4+ ). By using the encapsulated cation (Z) to "label" the POM, we track the phase-transformation and confirm the retention of single crystallinity. The integrated use of POM labeling and SCSC transformation enables rational control over cation distribution and establishes a versatile strategy for constructing multicomponent materials with high compositional and spatial precision.

Chen, Linfeng [Univ. of California, San Diego, CA

Investigating the effects of precise mass measurements of Ru and Pd isotopes on machine learning mass modeling

Atomic masses are a foundational quantity in our understanding of nuclear structure, astrophysics, and fundamental symmetries. The longstanding goal of creating a predictive global model for the binding energy of a nucleus remains a significant challenge, however, and prompts the need for precise measurements of atomic masses to serve as anchor points for model developments. We present precise mass measurements of neutron-rich Ru and Pd isotopes performed at the Californium Rare Isotope Breeder Upgrade facility at Argonne National Laboratory using the Canadian Penning Trap mass spectrometer. The masses of 108 Ru, 110 Ru, and 116 Pd were measured to a relative mass precision $\delta$⁢$m/m$ ≈ 10 -8 via the phase-imaging ion-cyclotron-resonance technique, and represent an improvement of approximately an order of magnitude over previous measurements. Further, these mass data were used in conjunction with the physically interpretable machine learning (PIML) model, which uses a mixture density neural network to model mass excesses via a mixture of Gaussian distributions. The effects of our new mass data on a Bayesian-updating of a PIML model are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Precise absolute 𝛾–ray intensities following the 𝛽 decay of 156 Eu

The most recent 𝛽-decay data for 156 Eu is over 40 years old, and the 𝛾-ray intensities are only known with a fractional precision of about 10% or worse. Here, in this work, we present new results for the absolute intensities of more than 60 𝛾 rays emitted following the 𝛽 decay of 156 Eu with many measured to ≲1% accuracy, representing an order-of-magnitude improvement in precision. This was achieved by leveraging the fission-product beams produced at the CARIBU facility to create radio-pure samples and detecting the radiation with a 4⁢𝜋 𝛽-particle counter coupled with a precisely efficiency-calibrated HPGe detector at Texas A and M University.

Physics - Nuclear physics and radiation physics

NCCS High Performance GMRES Mixed Precision

HPG-MxP is a software package that performs a fixed number of multigrid preconditioned (using a Gauss-Seidel smoother) Generalized minimal residual (PGMRES) iterations in order to solve a possibly nonsymmetric large sparse linear system of equations. It is designed to be a benchmark to measure a computer's performance for sparse linear algebra workloads typical in scientific computing while allowing the use of mixed precision methods. The solution is required to have convergence characteristics and accuracy similar to double precision GMRES. It is based on the High Performance Conjugate Gradient Benchmark (HPCG) which restricts all implementations to use only the IEEE double precision format (FP64). The original implementation (https://github.com/hpg-mxp/hpg-mxp) was written by Ichitaro Yamazaki, Jennifer Loe, Christian Glusa, Sivasankaran Rajamanickam, Piotr Luszczek, and Jack Dongarra. Please refer to that repository for documentation on the original implementation. This version is maintained by the National Center for Computational Sciences at Oak Ridge National Laboratory. It is highly scalable and optimized for Oak Ridge Leadership Computing Facility (OLCF) systems, particularly Frontier.

Kashi, Aditya [Oak Ridge National Laboratory (ORNL

MAMBA: A Prototype Modern Modular Bubble Chamber for Precision Measurement of Neutrino Nucleus Cross Sections

High precision measurements of neutrino interactions are essential for the success of future neutrino oscillation experiments. Understanding the interaction rate and precise energy spectrum requires understanding of neutrino interactions and nuclear effects. Measuring interactions in a light nuclear target , such as Hydrogen or deuterium, would provide highly valuable input to reduce reduce the uncertainties associated with neutrino-nucleus cross sections, relevant for upcoming experiments like the Deep Underground Neutrino Experiment (DUNE) and Hyper-Kamiokande (Hyper-K). A bubble chamber presents an opportunity to study a light nuclear target using hydrogen in the liquid phase as a working fluid. However historical hydrogen bubble chamber designs if placed in modern neutrino beams would miss a significant fraction of the total number of available interactions. We present a bubble chamber prototype, MAMBA, which will be used to investigate strategies for inexpensively enabling continuous cycling through improved cooling at scale and expanding the active time of historic bubble chambers. MAMBA aims to demonstrate the feasibility of precision neutrino–nucleon measurements at conditions comparable to modern beams.

Martínez Casales, María [Fermilab] (ORCID:00000003

A High-Precision, Fast, Robust, and Cost-Effective Muon Detector Concept for the FCC-ee

We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements. The drift tubes deliver two-dimensional position measurements perpendicular to the tubes with a resolution around 100~$\mu$m. Meanwhile, the scintillator strips, read out with the wavelength-shifting fibers and silicon photomultipliers, provide fast timing information with a precision of 200~ps or better and measure the third coordinate along the tubes with a resolution of about 1~mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Atomically Precise Nanoclusters as Co‐Catalysts for Light‐Activated Microswimmer Motility

Microswimmers are self-propelled particles that navigate fluid environments, offering significant potential for applications in environmental pollutant decomposition, biosensing, and targeted drug delivery. Their performance relies on engineered catalytic surfaces. Gold nanoclusters (AuNCs), with atomically precise structures, tunable optical properties, and high surface area-to-volume ratio, provide a new optimal catalyst for enhancing microswimmer propulsion. Unlike bulk gold or nanoparticles, AuNCs may deliver tunable photocatalytic activity and increased catalytic specificity, making them ideal co-catalysts for hybrid microswimmers. For the first time, this study combines AuNCs with TiO 2 /Cr 2 O 3 Janus microswimmers, combining the unique properties of both materials. This hybrid system capitalizes on the tuned optical properties of AuNCs and their role as co-catalysts with TiO 2 , driving enhanced photocatalytic performance under ultraviolet (UV) excitation. Using motion analysis, it is shown that the AuNC-microswimmers exhibit significantly greater propulsion and mean squared displacement (MSD) as compared to controls. These findings suggest that the integration of nanoclusters with semiconductor materials enables state of the art, light-switchable microswimmers. These AuNC-microswimmer systems may thus offer new opportunities for environmental catalysis and other applications, providing precise control over catalytic and motile behaviors at the microscale.

36 MATERIALS SCIENCE

Multi-physics melt pool modeling and process optimization for laser direct energy deposition of Nb-based refractory C103: Defect formation, geometric precision, and process mapping

Recent developments in additive manufacturing (AM) technology have reignited interest in the fabrication of the Nb-based refractory C103 alloy offering solutions to the challenges posed by traditional manufacturing methods. However, the limited numerical and experimental studies on laser direct energy deposition (DED) of C103 have hindered the understanding of the relationships between process parameters and build quality. This has made it challenging to consistently produce parts with the desired quality and microstructure suitable for critical applications. In this study, we focus on optimizing the laser DED process for C103 by employing a hybrid approach that combines experimental techniques and computational fluid dynamics (CFD). This approach facilitates the development of process maps for defect detection and geometric precision. To achieve this, multi-layer C103 samples were fabricated using laser DED under various process parameters, enabling the creation of a process map for defect detection. Additionally, a multi-physics, multiphase simulation framework was developed within a high-performance computing (HPC) environment to establish process maps for geometric precision. Using these process maps, printability windows were identified for achieving both the desired geometric accuracy and defect-free prints. It was observed that prints with a power-to-velocity (P/V) ratio close to unity resulted in defect-free outcomes. This study provides a foundation for reducing design lead time and rejected parts, ultimately optimizing the laser DED process for C103.

Defect formation and geometric precision