Beam test results for the Endcap Timing ReadOut Chip (ETROC2) for the CMS ETL upgrade

The Endcap Timing ReadOut Chip (ETROC) for the Compact Muon Solenoid (CMS) Minimum ionizing particle Timing Detector (MTD) is designed to process Low Gain Avalanche Diode (LGAD) signals with a time resolution of 40-50ps per hit, with 30-35 ps per charged particle using two layer detector. The ETROC2, is the first full size (16x16 pixels) and full functionally design that has been tested in hadron and electron beams at CERN and DESY (Sep 2023 - June 2024). Precision timing studies at these test beams are done using a self-referential beam telescope composed of up to 4 layers/chips. This talk describes the ETROC2 beam telescope and summarizes the performance of the ETROC2 chips bump-bonded to (16x16) Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) LGAD sensors using results from recent test beams. The experiences and lessons learned during the course of these test beams are also detailed in this talk.

Safdari, Murtaza↗

Development of an ab initio learned model of electron deposition range in deuterium-tritium plasmas through time-dependent density functional theory calculations and machine learning

Accurate hydrodynamic modeling for laser-direct-drive (LDD) inertial-confinement-fusion (ICF) relies on precise calculations of the electron thermal conduction in all target materials. The nonlocal stopping range of electrons in ICF plasmas directly influences thermal conduction; yet, no first principles model exists for the electron mean free path in the conduction-zone regime. This work utilized time-dependent stochastic density-functional theory (TD-sDFT) to calculate the electron stopping power in deuterium-tritium (DT) plasmas at (ρ, T) conditions relevant to the conduction zone and the compressed shell in ICF. Using a combination of our TD-sDFT data and already established analytical models, we developed and trained an artificial neural network to create a global model for the nonlocal electron deposition range, λ E . We compared our machine-learning (ML) based model for λ E to the currently-used modified-Lee-More model in LDD radiation-hydrodynamic codes, such as lilac, and saw an overall decrease in the deposition range. To understand the effects of λ E on LDD ICF implosion dynamics, we implemented the ML-based model into lilac; specifically, we looked at designs consistent with a current experiment on the OMEGA laser and for a newly designed LDD-ICF target for the future OMEGA-Next facility. In both cases, we saw an overall drop in predicted ablation pressure, peak areal density, and neutron yield due to the reduced thermal conduction (smaller λ E ) in DT plasmas. Comparisons with the experiment on OMEGA are also made.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High energy particle detection with large area superconducting microwire array

We present the first detailed study of an 8-channel2×2 mm$^{2}$ WSi superconducting microwire single photondetector (SMSPD) array exposed to 120 GeV proton beam and 8 GeVelectron and pion beam at the Fermilab Test Beam Facility. TheSMSPD detection efficiency was measured for the first time forprotons, electrons, and pions, enabled by the use of a silicontracking telescope that provided precise spatial resolution of30 μm for 120 GeV protons and 130 μm for 8 GeVelectrons and pions. The result demonstrated consistent detectionefficiency across pixels and at different bias currents. Timeresolution of 1.15 ns was measured for the first time for SMSPDwith proton, electron, and pions, enabled by the use of an MCP-PMTwhich provided a ps-level reference time stamp. The resultspresented is the first step towards developing SMSPD array systemsoptimized for high energy particle detection and identification forfuture accelerator-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the highfidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars.

SEXTANT↗

SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the high-fidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars

Pulsar↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Recent Advances in Precision Clock Synchronization Protocols for Power Grid Control Systems

With the advent of a new Precision Time Protocol specification, new opportunities abound for clock synchronization possibilities within power grid control systems. The third iteration of the Institute of Electrical and Electronics Engineers Standard 1588 specification provides several new features specifically aimed at complex, wide-area deployments in which situational awareness and control require precise time agreement. This paper describes the challenges faced by existing technology, introduces the new time distribution specification, and provides examples to explain how it represents a game-changing innovation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Continuous-time probabilistic models for longitudinal electronic health records

Analysis of longitudinal Electronic Health Record (EHR) data is an important goal for precision medicine. Difficulty in applying Machine Learning (ML) methods, either predictive or unsupervised, stems in part from the heterogeneity and irregular sampling of EHR data. Here, we present an unsupervised probabilistic model that captures nonlinear relationships between variables over continuous-time. This method works with arbitrary sampling patterns and captures the joint probability distribution between variable measurements and the time intervals between them. Inference algorithms are derived that can be used to evaluate the likelihood of future using under a trained model. As an example, we consider data from the United States Veterans Health Administration (VHA) in the areas of diabetes and depression. Likelihood ratio maps are produced showing the likelihood of risk for moderate-severe vs minimal depression as measured by the Patient Health Questionnaire-9 (PHQ-9).

59 BASIC BIOLOGICAL SCIENCES↗

Report of the Panel on Guidance, Navigation, and Control

Guidance, navigation, and control (GNC) systems have historically been vital to improving operational capability of aircraft. The development of autopilots and electronic navigation systems has greatly aided the crew in flying precise routes in all weather conditions while at the same time reducing pilot workload. Advances in high-integrity onboard computing and electronics technology have resulted in a significant increase in the capability of these subsystems to perform more reliably, efficiently, and safely. Onboard computing and control system capability has provided new design approaches for the aircraft designer. By using automatic control systems to stabilize the aircraft, the designer can relax certain conventional aerodynamic stability requirements and achieve aircraft performance benefits. Thus, modern fighter aircraft are designed with low levels, or in fact, negative levels of longitudinal static stability to boost maneuvering capability and cruise performance, relying on the use of full-time, full-authority automatic stability augmentation systems to stabilize the aircraft. During the next 20 years, GNC systems will become a driving force in aircraft design. Instead of making separately designed major aircraft systems work together, the designer will exploit the interaction and integration of aerodynamic, structural, and propulsion system controls to provide a better aircraft. The benefits of such integrated designs have been demonstrated already. Integrated digital control of the engine inlet and autopilot systems on a NASA YF-12 research aircraft resulted in a range increase of 7 percent. A civil transport derivative using extensions on each wing and an active control system to minimize the requirement for structural modifications achieved significant cruise performance improvements. These are first-generation applications of advanced GNC systems. More significant benefits are achievable by the year 2000. Complete integration of aerodynamic, propulsion and structural controls, and mission avionics will provide dramatically better aircraft performance, new capability (low observability, supermaneuverability) and/or improved mission effectiveness. This requires a concurrent, multidisciplinary design approach early in the design stage. The role of advanced GNC systems in future aircraft is not an option.

Fraser, Donald C.↗

Calorimetry for low-energy electrons using charge and light in liquid argon

Precise calorimetric reconstruction of 5–50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stopping cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT’s well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of σ/E≃9.3%/E⊕1.3% is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N≃30, for example, the energy resolution for electrons below 40 MeV is improved by ≈10%, ≈20%, and ≈40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of DARHT Axis 1 Injector Voltage

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injector electron beam energy. The technique for time resolved measurement of the electron beam energy using electron Permanent Magnet Spectrometer (ePMSpec) has been developed. The electron energy then is used to infer the voltage produced by the injector pulsed power. The injector pulsed power of DARHT I consists of a 1.5-MV, glycol-insulated Blumlein that is pulsecharged by a step-up transformer and switched by four, laser-triggered spark gaps. A series of increasing impedance transmission lines are used to transform the output voltage of the Blumlein to a maximum of 3.8MV at the diode. Figure 1a shows a graphic of the Axis-1 prime power tank, Blumlein and downstream transmission lines. The injector pulse power is designed to produce voltage on a velvet cathode located in the vacuum vessel. The specifications of the voltage-pulse flat-top over 60ns is +/-1%. A key element in the high-voltage circuit is the ethylene glycol Blumlein. The outer volume, adjacent to the laser triggered switches of the Blumlein, is a peaking capacitor. This is an independent volume that contains a mixture of ethylene glycol and water to make it an adjustable capacitor of 380 to 750 pF.

43 PARTICLE ACCELERATORS↗

Ilmenite as Dual-Use Material

This paper addresses the subject of dual-use space technology transfer of a novel, non-traditional material termed ilmenite, found in a large percentage in the moon rocks brought back by NASA's APOLLO missions. The paper is somewhat premature in the sense that though the material as a mineral has been known for a long time, very little is known about pure single crystal ilmenite and hence few applications have been demonstrated. Yet, in another sense, it is very timely due to the fact that ilmenite promises to be a very interesting competition to silicon, silicon carbide and other compound semiconductors, especially those that are employed in high power, high temperature and large data storage/retrieval applications. It seems to be an excellent example of a small investment-high return situation. While some of the applications of this material - for production of oxygen, for instance - have been well-known, electronic applications have received relatively little attention. One reason for this was the fact that growth of single crystal ilmenite requires precise process conditions and parameters. We believe for the first time these have been determined in the Center for Electronic Materials, Texas A&M University. The work being done at Texas A&M University and Prairie View A&M University (supported by Battelle Pacific Northwest Laboratories and the Center for Space Power) indicates the excellent potential this material has in space as well as in terrestrial applications. To mention a few: as a wide band gap semiconductor it has applications in high temperature, high power situations, especially when heat dissipation is a problem such as may occur in the Space Station; the possibility of this material radiating in the blue region, it has immense applications in optoelectronics; as a material with a high density of highly directional d-bands, it lends itself to novel processing conditions and perhaps even to 'tunability' of physical parameters; as a potential scintillating material, it has possible applications as a sensor in waste management; as an oxygen sensor it has possible applications in automotive electronics; and as a radiation resistant material, it has obvious applications in the space environment. Results - experimental and theoretical - obtained so far in our laboratories will be reported with particular emphasis on the transfer of technology involving this fascinating material.

Kumar, A. A.↗

A hybrid 3D/2D field response calculation for liquid argon detectors with PCB based anode plane

Liquid Argon Time Projection Chamber (LArTPC) technology is commonly utilized in neutrino detector designs. It enables detailed reconstruction of neutrino events with high spatial precision and low energy threshold. Its field response (FR) model describes the time-dependent electric currents induced in the anode-plane electrodes when ionization electrons drift nearby. An accurate and precise FR is a crucial input to LArTPC detector simulations and charge reconstruction. Established LArTPC designs have been based on parallel wire planes. It allows accurate and computationally economic two-dimensional (2D) FR models utilizing the translational symmetry along the direction of the wires. Recently, novel LArTPC designs utilize electrodes formed on printed circuit board (PCB) in the shape of strips with through holes. The translational symmetry is no longer a good approximation near the electrodes and a new FR calculation that employs regions with three dimensions (3D) has been developed. Extending the 2D models to 3D would be computationally expensive. Fortuitously, the nature of strips with through holes allows for a computationally economic approach based on the finite-difference method (FDM). In this paper, we present a new software package pochoir that calculates LArTPC field response for these new strip-based anode designs. This package combines 3D calculations in the volume near the electrodes with 2D far-field solutions to achieve fast and precise field response computation. We apply the resulting FR to simulate and reconstruct samples of cosmic-ray muons and 39 Ar decays from a Vertical Drift (VD) detector prototype operated at CERN. We find the difference between real and simulated data within 5%. Current state-of-the-art LArTPC software requires a 2D FR which we provide by averaging over one dimension and estimate that variations lost in this average are smaller than 7%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strong ultrafast nonlinear optical response from megaelectronvolt electrons in semiconductors

Understanding radiation–matter interactions on ultrafast timescales is essential for radiation detection technologies, particularly those requiring precise timing, such as plasma monitoring, synchrotron diagnostics and medical imaging. However, the detection of highly ionizing radiation is challenging due to the stochastic nature of the interactions, resulting in dispersed energy deposition. Here we show a nonlinear optical response in semiconductors induced by 150-fs, 4.2-MeV electrons that generate highly localized charge carriers. The induced sub-10-ps optical modulation reached up to 24.5%, accompanied by a blueshift in the absorption edge consistent with band filling and carrier densities of 10 18 cm −3 . These carrier densities are 100-fold higher than expected from the deposited energy, indicating the extreme spatial localization of carriers at inelastic collisions along the ionization trajectories, thereby leading to the observed modulation. The strong nonlinearity of the MeV-electron-induced optical response enables the precise spatiotemporal detection of ionizing radiation at room temperature using common semiconductors and laser systems.

Jeong, D. [Stanford Univ., CA (United States)] (OR↗

MicroBooNE Electron-Neutrino Cross-Section Results

Measurement of the electron-neutrino cross-section with argon ($\nu$-Ar) is crucial for current and future neutrino experiments. Results from MicroBooNE detector, a liquid argon time projection chamber (LArTPC) based at Fermilab, provide the most extensive and precise determination of these electron-neutrino cross-sections. MicroBooNE is situated on both on-axis and off-axis beams: the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam, respectively. The background for both beams is dominated by showers from neutral pion decay, necessitating an electron-photon separation technique. In this proceeding, we review three recent electron-neutrino cross-section results from MicroBooNE using NuMI and BNB.

Guzzo, Marina [Edinburgh U.]↗

Flight management - Pilot procedures and system interfaces for the 1980-1990's

In the air transportation system of the 1980-1990's, aircraft must perform with greater precision in time and position than is possible today. Rapid development in electronics technology makes renovation in airborne-system concepts feasible. The Ames Research Center is conducting research on pilot procedures and pilot-system interfaces for such systems. Research on various pilot-system interface devices and manned simulations was conducted to study rules of distributed decision making authority among pilots and controllers with various airborne display concepts, and a pilot-oriented command logic for the control of avionic systems was studied. Results are summarized, and ongoing work and future research plans described.

Wempe, T. E.↗

Reduction and analysis of data from experiment CAI on the IMP-8 mission

The Caltech Electron/Isotope Spectrometer (EIS) on the Interplanetary Monitoring Platform 8 (IMP-8) has provided precise measurements of the energy spectra and time variations of low energy electrons (0.16 to 6 MeV), the isotopes of hydrogen and helium (approximately 2 to 40 MeV/nucleon), and the elements from lithium through oxygen (approximately 5 to 50 MeV/nucleon) in energetic particle fluxes of solar, galactic, interplanetary, and magnetospheric origin since 1973. The accomplishments that have resulted from EIS measurements during the period March 24, 1980 to December 31, 1984 are summarized.

Stone, E. C.↗