Synthesis of atomically precise single-crystalline Ru[subscript 2]-based coordination polymers
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Not provided.
Active voltage divider applies different logic signals to field-effect transistor switches to generate various voltage levels at output. Circuit is compact and reduces errors from drifting component values.
Explore the source record for details and available documents.
Over the last year, the ECP xSDK-multiprecision effort has made tremendous progress in developing and deploying new mixed precision technology and customizing the algorithms for the hardware deployed in the ECP flagship supercomputers. The effort also has succeeded in creating a cross-laboratory community of scientists interested in mixed precision technology and now working together in deploying this technology for ECP applications. In this report, we highlight some of the most promising and impactful achievements of the last year. Among the highlights we present are: Mixed precision IR using a dense LU factorization and achieving a 1.8× speedup on Spock; results and strategies for mixed precision IR using a sparse LU factorization; a mixed precision eigenvalue solver; Mixed Precision GMRES-IR being deployed in Trilinos, and achieving a speedup of 1.4× over standard GMRES; compressed Basis (CB) GMRES being deployed in Ginkgo and achieving an average 1.4× speedup over standard GMRES; preparing hypre for mixed precision execution; mixed precision sparse approximate inverse preconditioners achieving an average speedup of 1.2×; and detailed description of the memory accessor separating the arithmetic precision from the memory precision, and enabling memory-bound low precision BLAS 1/2 operations to increase the accuracy by using high precision in the computations without degrading the performance. We emphasize that many of the highlights presented here have also been submitted to peer-reviewed journals or established conferences, and are under peer-review or have already been published.
Over the last year, the ECP xSDK-multiprecision effort has made tremendous progress in developing and deploying new mixed precision technology and customizing the algorithms for the hardware deployed in the ECP flagship supercomputers. The effort also has succeeded in creating a cross-laboratory community of scientists interested in mixed precision technology and now working together in deploying this technology for ECP applications. In this report, we highlight some of the most promising and impactful achievements of the last year. Among the highlights we present are • Mixed precision IR using a dense LU factorization and achieving a 1.8× speedup on Spock; • Results and strategies for mixed precision IR using a sparse LU factorization; • A mixed precision eigenvalue solver; • Mixed Precision GMRES-IR being deployed in Trilinos, and achieving a speedup of 1.4× over standard GMRES; • Compressed Basis (CB) GMRES being deployed in Ginkgo and achieving an average 1.4× speedup over standard GMRES; • Preparing hypre for mixed precision execution; • Mixed precision sparse approximate inverse preconditioners achieving an average speedup of 1.2×; • Detailed description of the memory accessor separating the arithmetic precision from the memory precision, and enabling memory-bound low precision BLAS 1/2 operations to increase the accuracy by using high precision in the computations without degrading the performance. We emphasize that many of the highlights presented here have also been submitted to peer-reviewed journals or established conferences, and are under peer-review or have already been published.
Abstract Low precision arithmetic, in particular half precision (16‐bit) floating point arithmetic, is now available in commercial hardware. Using lower precision can offer significant savings in computation and communication costs with proportional savings in energy. Motivated by this, there has been a renewed interest in mixed precision iterative refinement schemes for solving linear systems , and new variants of GMRES‐based iterative refinement have been developed. Each particular variant with a given combination of precisions leads to different condition number‐based constraints for convergence of the backward and forward errors, and each has different performance costs. The constraints for convergence given in the literature are, as an artifact of the analyses, often overly strict in practice, and thus could lead a user to select a more expensive variant when a less expensive one would have sufficed. In this work, we develop a multistage mixed precision iterative refinement solver which aims to combine existing mixed precision approaches to balance performance and accuracy and improve usability. For a user‐specified initial combination of precisions, the algorithm begins with the least expensive approach and convergence is monitored via inexpensive computations with quantities produced during the iteration. If slow convergence or divergence is detected using particular stopping criteria, the algorithm switches to use a more expensive, but more reliable variant. A novel aspect of our approach is that, unlike existing implementations, our algorithm first attempts to use “stronger” GMRES‐based solvers for the solution update before resorting to increasing the precision(s). In some scenarios, this can avoid the need to refactorize the matrix in higher precision. We perform extensive numerical experiments on a variety of random dense problems and problems from real applications which confirm the benefits of the multistage approach.
Industrial separations require enormous amounts of energy, accounting for approximately half the industrial energy use and 10–15% of the total energy consumption. Distillation alone accounts for about half the energy demand for industrial separations. If these processes could be replaced by an energy-efficient membrane separation process, this energy demand could be reduced by 90%. However, although some membrane processes have made inroads into thermal distillation, for membrane-based separations to replace the distillation process to a far more significant and practical level, new membranes with higher robustness, selectivity, and flux still need be developed. In this membrane development program, we leveraged Temple University’s prior work in spiroligomers to develop robust membrane structures. These structures can be formed into atomically precise pores by controlling the chemical synthesis and the oligomer building blocks to first build precisely controlled macrocycles and then subsequently crosslinking these macrocycles to produce a membrane. Furthermore, through the highly controllable chemistry of our molecular building blocks, not only can we integrate pores with highly controllable and reproducible size and morphology, but we can also target internal functionalization. By using a range of scalable membrane synthesis approaches, combined with control of each and every pores internal chemistry and molecular conformation we can achieve membrane structures that can display the ultimate in high selectivity and permeance. The Mainstream-Temple University membranes can be designed to achieve ultra-selective separations based on the key factors of molecular size, shape, and functionality. In our approach to fabricate scalable atomically precise membranes, we used our molecular Lego nanostructures. We demonstrated an approach to create atomically precise pores within the membrane with pores that are the dimensions of the molecule we are trying to separate. Moreover, in addition to controlling the morphology of the membrane structure by controlling the size of every pore, we can also decorate every pore with precisely targeted and placed functional groups. These accurately placed functional groups can provide selective binding to molecules and provide enhanced selectivity via a facilitated transport mechanism. In Phase II, the Mainstream-Temple University team demonstrated the scalable synthesis of oligomers and the ability to control the pore internal and external functionality, or chemistry, to allow the fabrication of a thin-film membrane. The initial steps of the spiroligomer synthesis to produce the two key bis-amino enantiomer building blocks were scaled from the gram scale to the kilogram scale, obtaining 25 kg of the materials by transferring the procedure to a toll manufacturer. Finally, we successfully optimized the fabrication of these macrocycles into robust membranes. We successfully transitioned from a laboratory based, hard-to-scale Langmuir trough synthesis to a highly scalable, roll-to-roll applicable, interfacial polymerization process. During this Phase II program, we established a platform of atomically precise membranes where our highly controllable, atomically precise macrocycles served as a scaffold with precisely and uniformly controlled pores. Furthermore, this layer can be tailored to accommodate a diverse range of functional groups, which both further controlled the pore size to enhance the sieving effect as well as imparting precisely controlled targeted selectivity through biomimetic molecular interactions. In this Phase II, we established and scaled up a platform approach to both tune the pore size and chemistry as well as scale it to produce membranes that can be applied to a wide range of industries. In future development, the project team expects to scale up both the macrocycle building block production and interfacial polymerization process to produce the atomically precise membrane with targeted pore sizes and pore chemistries.
The explosive demand for artificial intelligence (AI) workloads has led to a significant increase in silicon area dedicated to lower-precision computations on recent high-performance computing hardware designs. However, mixed-precision capabilities, which can achieve performance improvements of up to 8x compared to double-precision in extreme compute-intensive workloads, remain largely untapped in most scientific applications. A growing number of efforts have shown that mixed-precision algorithmic innovations can deliver superior performance without sacrificing accuracy. These developments should prompt computational scientists to seriously consider whether their scientific modeling and simulation applications could benefit from the acceleration offered by new hardware and mixed-precision algorithms. In this survey, we (1) review progress across diverse scientific domains—fluid dynamics, weather and climate, quantum chemistry, and computational genomics—that have begun adopting mixed-precision strategies; (2) examine state-of-the-art algorithmic techniques such as iterative refinement, splitting and emulation schemes, and adaptive precision solvers; (3) assess their implications for accuracy, performance, and resource utilization; and (4) survey the emerging software ecosystem that enables mixed-precision methods at scale. We conclude with perspectives and recommendations on cross-cutting opportunities, domain-specific challenges, and the role of co-design between application scientists, numerical analysts, and computer scientists. Collectively, this survey underscores that mixed-precision numerics can reshape computational science by aligning algorithms with the evolving landscape of hardware capabilities.
Quantization, effective Neural Network architecture, and efficient accelerator hardware are three important design paradigms to maximize accuracy and efficiency. Mixed Precision Quantization is a process of assigning different precision to different Neural Network layers for optimized inference. Neural Architecture Search (NAS) is a process of automatically designing the neural network for a task and can also be extended to search for the precision of each weight and activation matrix. In this paper, we develop the following three methods: (i) Fast Differentiable Hardware-aware Mixed Precision Quantization Search method to find optimal precision, (ii) Joint Differentiable hardware-aware Architecture and Mixed Precision Quantization Co-search, (iii) Joint Accelerator, Architecture, and Precision triple co-search to find best possibilities in all the three worlds. We demonstrate the effectiveness of our proposed methods targeting Bitfusion accelerator by searching mixed precision models on MobilenetV2. We achieve better accuracy-latency trade-off models than the manually designed and previously proposed search methods.
The third quarter of the project was spent performing theoretical finite precision analysis of Krylov subspace method variants that use mixed precision. Our focus here is on the Conjugate Gradient (CG) method and the Lanczos method. We have performed an analysis of maximum attainable accuracy for the classical CG method in which 3 precisions are used: a working precision ε, a precision ε IP for the inner product computations, and a precision ε MV for the matrix-vector products. Our results show that performing inner product computations in lower precision does not affect the attainable accuracy. Further, we have performed a complete error analysis of the s-step Lanczos algorithm. In this case, we show that the numerical behavior of the algorithm can be significantly improved by using extra precision in a small part of the computation. We summarize the main theorems in the remainder of the document. Other activities include attending biweekly xSDK meetings. The subsequent quarter will be spent finalizing these results into technical reports and/or manuscripts for submission to journals, as well as identifying opportunities for future work.
Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.
Dynamic measurement precision assessment has been achieved for a differential circle measurement application. Differential circle diameter measurement, in image analysis, typically requires fitting a circle model that optimizes for image distortions, defects or occlusions. The differential task occurs when precise measurements of diameter change are required given object size variation with time. An automated system was designed to provide diameter measurements and associated measurement precision of images of a fuel droplet undergoing combustion in zero gravity for the FLEX-2 dataset. An image gradient-based, least-squares boundary point fitting method to a circle or ellipse model is used for diameter measurement. The presence of soot aggregates poses significant challenges for diameter measurements when it occludes part of the droplet boundary. The precision of the diameter measurements depends upon the image quality. Using synthetic image simulations that model the soot behavior, we developed a model based on image quality measures that assesses the measurement precision for each individual diameter measurement. Thus, diameter measurements with precision assessments were made available for follow-up scientific analysis. As a result, the algorithm's success rate for measurable runs was 98%. In cases of limited occlusion, a measurement precision of ±0.2 pixels for the FLEX-2 dataset was achieved.
Here, we investigate whether (and how) experimental design could aid in the estimation of the precision matrix in a Gaussian chain graph model, especially the interplay between the design, the effect of the experiment and prior knowledge about the effect. Estimation of the precision matrix is a fundamental task to infer biological graphical structures like microbial networks. We compare the marginal posterior precision of the precision matrix under four priors: flat, conjugate Normal-Wishart, Normal-MGIG and a general independent. Under the flat and conjugate priors, the Laplace-approximated posterior precision is not a function of the design matrix rendering useless any efforts to find an optimal experimental design to infer the precision matrix. In contrast, the Normal-MGIG and general independent priors do allow for the search of optimal experimental designs, yet there is a sharp upper bound on the information that can be extracted from a given experiment. We confirm our theoretical findings via a simulation study comparing (i) the KL divergence between prior and posterior and (ii) the Stein’s loss difference of MAPs between random and no experiment. Our findings provide practical advice for domain scientists conducting experiments to better infer the precision matrix as a representation of a biological network.
Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.