Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision health”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Medicine and Pharmacogenomics for Human Deep Space Exploration

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expanding duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be even more essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to further tailor medications included in the spacecraft formulary and increased examination of appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of cutting-edge research and medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique factors and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. One example is the field of pharmacogenomics (PGX),the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on pharmaceutical choice and dosing to avoid adverse drug events and maximize pharmacological efficacy. The goal of this study was to evaluate which drugs in the current space pharmacy could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs onboard the International Space Station (ISS) was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both personal astronaut medications, including supplements and over the counter drugs (n=151) and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in 157 total drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure. Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent adverse events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost or technical and ranked from 1 (very low) to 5 (very high).A comprehensive assessment of commercially available PGX solutions is currently underway to evaluate specimen requirements, cost/benefit analysis (cost vs. number of alleles assessed), utility of variant analysis, relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments(LxC 5x5 table) indicated29medicationswere in the yellow or red zone driven predominantly by drug failure or safety concerns, with the remainder(n=128)of the medications in the green zone where risk is acceptable. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive pre-flight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve targeting drug efficacy and safety, and further open the door to countermeasure research exploring PGX-related allelic variants. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more cost effective and more efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing crew autonomy and providing tailored countermeasures

Alice R W Tang↗

Identification of Health Events in Astronaut Missions Using Longitudinal Molecular Signature Detection

Individualized health monitoring can now incorporate a precision medicine approach, profiling multiple molecular and physiological measures of health (generalized omics) longitudinally to enable the timely diagnosis and treatment of disease. Such measurements can include blood chemistries, gene expression data, metabolite measurements, and digital device data. We will present our work on extending such an approach to monitoring individual astronaut health for deep space missions. We have developed and implemented novel algorithms to monitor and detect physiolgical state departures from individualized healthy astronaut baselines , utilizing and biologically annotating generalized omics. Our new methods can detect baseline deviations across omics corresponding to potentially adverse medical events. Events pointing to changes in individual health are then compared across individuals to identify common responses and detect changes affecting multiple crewmembers. We show the utility of our methods in detecting temporal health changes across subjects using retrospective Earth and astronaut mission data (metabolite and immune marker data across multiple missions), in order for this technique t o be applicable for future missions.

G I Mias↗

Battery Energy Storage Systems: A Review of Energy Management Systems and Health Metrics

With increasing concerns about climate change, there is a transition from high-carbon-emitting fuels to green energy resources in various applications including household, commercial, transportation, and electric grid applications. Even though renewable energy resources are receiving traction for being carbon-neutral, their availability is intermittent. To address this issue to achieve extensive application, the integration of energy storage systems in conjunction with these resources is becoming a recommended practice. Additionally, in the transportation sector, the increased demand for EVs requires the development of energy storage systems that can deliver energy for rigorous driving cycles, with lithium-ion-based batteries emerging as the superior choice for energy storage due to their high power and energy densities, length of their life cycle, low self-discharge rates, and reasonable cost. As a result, battery energy storage systems (BESSs) are becoming a primary energy storage system. The high-performance demand on these BESS can have severe negative effects on their internal operations such as heating and catching on fire when operating in overcharge or undercharge states. Reduced efficiency and poor charge storage result in the battery operating at higher temperatures. To mitigate early battery degradation, battery management systems (BMSs) have been devised to enhance battery life and ensure normal operation under safe operating conditions. Some BMSs are capable of determining precise state estimations to ensure safe battery operation and reduce hazards. Precise estimation of battery health is computed by evaluating several metrics and is a central factor in effective battery management systems. In this scenario, the accurate estimation of the health indicators (HIs) of the battery becomes even more important within the framework of a BMS. This paper provides a comprehensive review and discussion of battery management systems and different health indicators for BESSs, with suitable classification based on key characteristics.

Nazaralizadeh, Solmaz (ORCID:0009000737004039)↗

Predictive Risk Mapping of Schistosomiasis in Madagascar Using Ecological Niche Modeling and Precision Mapping

Schistosomiasis is a neglected tropical disease (NTD) found throughout tropical and subtropical Africa. In Madagascar, the condition is widespread and endemic in 74% of all administrative districts in the country. Despite the significant burden of the disease, high-resolution risk maps have yet to be produced to guide national control programs. This study used an ecological niche modeling (ENM) and precision mapping approach to estimate environmental suitability and disease transmission risk. The results show that suitability for schistosomiasis is widespread and covers 264,781 km 2 (102,232 sq miles). Covariates of significance to the model were the accessibility to cities, distance to water, enhanced vegetation index (EVI), annual mean temperature, land surface temperature (LST), clay content, and annual precipitation. Disease transmission risk is greatest in the central highlands, tropical east coast, arid-southwest, and northwest. An estimated 14.9 million people could be at risk of schistosomiasis; 11.4 million reside in rural areas, while 3.5 million are in urban areas. This study provides valuable insight into the geography of schistosomiasis in Madagascar and its potential risk to human populations. Because of the focal nature of the disease, these maps can inform national surveillance programs while improving understanding of areas in need of medical interventions.

60 APPLIED LIFE SCIENCES↗

ICESat-2 Constraint Analysis and Monitoring System (CAMS)

The Ice, Cloud and land Elevation Satellite-2 was launched on 15 September 2018 with mission goals of collecting surface elevation data that can precisely measure ice sheet topography, cloud and aerosol heights, land topography, as well as vegetation height for ecosystems studies. The Constraint Analysis and Monitoring System (CAMS) was implemented as an ICESat-2 ground system element to perform Mission Planning and Spacecraft Safety Monitoring. Mission Planning requires CAMS to serve as an interface between the Project Science Office, the Instrument Support Facility and the Mission Operation Control Center. By ingesting inputs received from all three groups, the CAMS builds an optimized and deconflicted timeline of science and instrument activities. Based upon the timeline of activities, the CAMS utilizes a sophisticated set of algorithms to model and predict the location and pointing of the spacecraft instrument relative to the Earth and Sun. From the predicted position and pointing, the CAMS provides precise monitoring of instrument health, and performs space asset laser conjunction detection. Furthermore, the CAMS determines alternative plans to prevent detected health constraint violations or mitigate potential laser conjunctions. This paper provides an overview of the CAMS and presents the operational performance of planning science and instrument activities, the monitoring of instrument constraints for health and safety, and the space asset laser conjunction screening and mitigation process.

ICESat-2↗

Intrinsically stretchable neuromorphic devices for on-body processing of health data with artificial intelligence

For leveraging wearable technologies to advance precision medicine, personalized and learning-based analysis of continuously acquired health data is indispensable, for which neuromorphic computing could provide the most efficient implementation of artificial intelligence (AI) data processing. For realizing on-body neuromorphic computing, skin-like stretchability is required, but yet to be combined with the suite of desired neuromorphic metrics, including linear, symmetric weight update, and sufficient state retention, for achieving high computing efficiency. Here, we report an intrinsically stretchable neuromorphic device based on an electrochemical transistor, which provides a large number (>800) of states, linear/symmetric weight update, excellent switching endurance (>100 million), good state retention (>10 4 s), together with high stretchability of 100% strain. Further integration into a prototype array successfully realized the implementation of vector-matrix multiplication even at 100% strain. Finally, we demonstrate the feasibility of implementing AI-based classification of health signals (as exemplified by electrocardiograms) with a high accuracy that is minimally influenced by the stretched state of the neuromorphic hardware. Finally, this work breaks the ground for combining AI data analysis into skin-like wearable electronics for achieving human-integrated/mimetic intelligent systems.

60 APPLIED LIFE SCIENCES↗

Detection and Screening of Organic Contaminants in A Riverine System of Georgia Using Non-Targeted Analysis

Numerous organic chemicals exist within aquatic environments, yet effectively screening and prioritizing them is a huge challenge. This study provides a comprehensive investigation into the ecological dynamics of the North Oconee River within Athens-Clarke County, Georgia, with a specific focus on the distribution of 33 identified compounds, including a prominent pesticide. The research, conducted in the riverine ecosystems proximal to the Firefly trail, employs advanced analytical techniques to elucidate potential contamination sources arising from agricultural and urban runoff. Intriguingly, the study reveals North Oconee River near the Firefly Trail as a notable site for heightened pesticide contamination, warranting a meticulous exploration of its origins. Furthermore, the investigation unveils the intricate microbial degradation processes of malathion within the North Oconee River, elucidating the pivotal role played by microbial activity in river water. The detection of degradant byproducts prompts the considerations of bioavailability and toxicity, associating potential implications for the river’s overall ecological health. Ongoing research endeavors to precisely quantify environmental risks and unravel indigenous microbial degradation pathways, presenting pivotal contributions to the scientific community’s understanding of complex riverine ecosystems. This research serves as a foundational piece in informing sustainable environmental management practices and emphasizes the urgency of comprehensive stewardship in safeguarding aquatic ecosystems.

54 ENVIRONMENTAL SCIENCES↗

High-Temperature Hybrid Rotor Support System Developed

The Army Research Laboratory Vehicle Technology Directorate and the NASA Glenn Research Center demonstrated a unique high-speed, high-temperature rotor support system in September 2003. Advanced turbomachinery is on its way to surpassing the capabilities of rolling-element bearings and conventional dampers. To meet these demands, gas turbine engines of the future will demand increased efficiency and thrust-to-weight ratio, and reduced specific fuel consumption and noise. The more-electric engine replaces oil-lubricated bearings, dampers, gears, and seals with electrical devices. One such device is the magnetic bearing. The Vehicle Technology Directorate and Glenn have demonstrated the operation of a radial magnetic bearing in combination with a hydrostatic bearing at 1000 F at 31,000 rpm (2.3 MDN1). This unique combination takes advantage of a high-temperature rub surface in the event of electrical power loss or sudden overloads. The hydrostatic bearings allow load sharing with the magnetic bearing. The magnetic-hydrostatic bearing combination eliminates wear and high contact stress from sudden acceleration of the rolling-element bearings and overheating. The magnetic bearing enables high damping, adaptive vibration control, and precise rotor positioning, diagnostics, and health monitoring. A model of the test facility used at Glenn for this technology demonstration is shown. A high-temperature heteropolar radial magnetic bearing is located at the center of gravity of the test rotor. There is a 0.022-in. radial air gap between the rotor and stator. Two rub surface hydrostatic bearings were placed on either side of the magnetic bearing. The rotor is supported by a 0.002-in. hydrostatic air film and the magnetic field. The prototype active magnetic bearing cost $24,000 to design and fabricate and a set of four high temperature, rub-surface, hydrostatic bearings cost $28,000. This work was funded by the Turbine-Based Combined Cycle program.

Montague, Gerald T.↗

Robust Platinum Resistor Thermometer (PRT) Sensors and Reliable Bonding for Space Missions

Platinum resistance thermometers (PRTs) provide accurate temperature measurements over a wide temperature range and are used extensively on space missions due to their simplicity and linearity. A standard on spacecraft, PRTs are used to provide precision temperature control and vehicle health assessment. This paper reviews the extensive reliability testing of platinum resistor thermometer sensors (PRTs) and bonding methods used on the Mars Science Laboratory (MSL) mission and for the upcoming Soil Moisture Active Passive (SMAP) mission. During the Mars Exploration Rover (MER) mission, several key, JPL-packaged PRTs failed on those rovers prior to and within 1-Sol of landing due to thermally induced stresses. Similar failures can be traced back to other JPL missions dating back thirty years. As a result, MSL sought out a PRT more forgiving to the packaging configurations used at JPL, and extensively tested the Honeywell HRTS-5760-B-U-0-12 sensor to successfully demonstrate suitable robustness to thermal cycling. Specifically, this PRT was cycled 2,000 times, simulating three Martian winters and summers. The PRTs were bonded to six substrate materials (Aluminum 7050, treated Magnesium AZ231-B, Stainless Steel 304, Albemet, Titanium 6AL4V, and G-10), using four different aerospace adhesives--two epoxies and two silicones--that conformed to MSL's low out-gassing requirements. An additional epoxy was tested in a shorter environmental cycling test, when the need for a different temperature range adhesive was necessary for mobility and actuator hardware late in the fabrication process. All of this testing, along with electrostatic discharge (ESD) and destructive part analyses, demonstrate that this PRT is highly robust, and not subject to the failure of PRTs on previous missions. While there were two PRTs that failed during fabrication, to date there have been no in-flight PRT failures on MSL, including those on the Curiosity rover. Since MSL, the sensor has gone through a change in construction such that the manufacturer significantly restricts the minimum temperature. However, significant subsequent testing was performed with this new version of the part to show that it indeed is still robust to at least Mars minimum temperatures of -135(sup o)C. The additional completed testing will be described. This work has resulted in a successful sensor package qualification and a reliable bonding method suitable for use over large temperature extremes.

dectector↗

Robust Platinum Resistor Thermometer (PRT) Sensors and Reliable Bonding for Space Missions

Platinum resistance thermometers (PRTs) provide accurate temperature measurements over a wide temperature range and are used extensively on space missions due to their simplicity and linearity. A standard on spacecraft, PRTs are used to provide precision temperature control and vehicle health assessment. This paper reviews the extensive reliability testing of platinum resistor thermometer sensors (PRTs) and bonding methods used on the Mars Science Laboratory (MSL) mission and for the upcoming Soil Moisture Active Passive (SMAP) mission. During the Mars Exploration Rover (MER) mission, several key, JPL-packaged PRTs failed on those rovers prior to and within 1-Sol of landing due to thermally induced stresses. Similar failures can be traced back to other JPL missions dating back thirty years. As a result, MSL sought out a PRT more forgiving to the packaging configurations used at JPL, and extensively tested the Honeywell HRTS-5760-B-U-0-12 sensor to successfully demonstrate suitable robustness to thermal cycling. Specifically, this PRT was cycled 2,000 times, simulating three Martian winters and summers. The PRTs were bonded to six substrate materials (Aluminum 7050, treated Magnesium AZ231-B, Stainless Steel 304, Albemet, Titanium 6AL4V, and G-10), using four different aerospace adhesives--two epoxies and two silicones--that conformed to MSL's low out-gassing requirements. An additional epoxy was tested in a shorter environmental cycling test, when the need for a different temperature range adhesive was necessary for mobility and actuator hardware late in the fabrication process. All of this testing, along with electrostatic discharge (ESD) and destructive part analyses, demonstrate that this PRT is highly robust, and not subject to the failure of PRTs on previous missions. While there were two PRTs that failed during fabrication, to date there have been no in-flight PRT failures on MSL, including those on the Curiosity rover. Since MSL, the sensor has gone through a change in construction such that the manufacturer significantly restricts the minimum temperature. However, significant subsequent testing was performed with this new version of the part to show that it indeed is still robust to at least Mars minimum temperatures of -135 degrees Centigrade. The additional completed testing will be described. This work has resulted in a successful sensor package qualification and a reliable bonding method suitable for use over large temperature extremes

Platinum Resistor Thermometer (PRT)↗

A Knowledge Graph Approach to Analyze Systems and Assets Health

Nuclear power plants collect large amounts of equipment reliability data elements that contain information on the statuses of component, assets, and systems. All these data elements precisely record asset and system performance and health throughout the lifecycle of those assets and systems. However, several challenges have proved to be roadblocks to this process. While some of these challenges are technical in nature (i.e., data are often distributed over several physical servers or databases), others are conceptual in nature (i.e., data elements come in different formats, numeric or textual), and measured values have different scales (e.g., vibration spectra and oil temperature). This paper directly focuses on the integration of numeric and textual data elements in order to assist plant system engineers in analyzing equipment reliability data. This task begins with preprocessing the data by extracting knowledge from textual data via natural language processing methods and quantifying system, asset, and component health based on numeric data. We then employed model-based system engineering (MBSE) models of systems and assets to identify their architecture and functional (i.e., cause and effect) relations. Data elements were then associated with a single MBSE graph element, based on their nature. This bonding of MBSE models and data elements constitutes a first-of-its-kind knowledge graph of a nuclear power plants system, with data elements being organized in a structured manner that enables system engineers to identify cause-effect trends in data elements and carry out appropriate actions in response.

97 - MATHEMATICS AND COMPUTING↗

Active Solid State Dosimetry for Lunar EVA

The primary threat to astronauts from space radiation is high-energy charged particles, such as electrons, protons, alpha and heavier particles, originating from galactic cosmic radiation (GCR), solar particle events (SPEs) and trapped radiation belts in Earth orbit. There is also the added threat of secondary neutrons generated as the space radiation interacts with atmosphere, soil and structural materials.[1] For Lunar exploration missions, the habitats and transfer vehicles are expected to provide shielding from standard background radiation. Unfortunately, the Lunar Extravehicular Activity (EVA) suit is not expected to afford such shielding. Astronauts need to be aware of potentially hazardous conditions in their immediate area on EVA before a health and hardware risk arises. These conditions would include fluctuations of the local radiation field due to changes in the space radiation field and unknown variations in the local surface composition. Should undue exposure occur, knowledge of the dynamic intensity conditions during the exposure will allow more precise diagnostic assessment of the potential health risk to the exposed individual.[2]

Wrbanek, John D.↗

The Vertebrate Breed Ontology: Toward Effective Breed Data Standardization

Abstract Background Limited universally-adopted data standards in veterinary medicine hinder data interoperability and therefore integration and comparison; this ultimately impedes the application of existing information-based tools to support advancement in diagnostics, treatments, and precision medicine. Hypothesis/Objectives A single, coherent, logic-based standard for documenting breed names in health, production, and research-related records will improve data use capabilities in veterinary and comparative medicine. Animals No live animals were used. Methods The Vertebrate Breed Ontology (VBO) was created from breed names and related information compiled from the Food and Agriculture Organization of the United Nations, breed registries, communities, and experts, using manual and computational approaches. Each breed is represented by a VBO term that includes breed information and provenance as metadata. VBO terms are classified using description logic to allow computational applications and Artificial Intelligence–readiness. Results VBO is an open, community-driven ontology representing over 19 500 livestock and companion animal breed concepts covering 49 species. Breeds are classified based on community and expert conventions (e.g., cattle breed) and supported by relations to the breed's genus and species indicated by National Center for Biotechnology Information (NCBI) Taxonomy terms. Relationships between VBO terms (e.g., relating breeds to their foundation stock) provide additional context to support advanced data analytics. VBO term metadata includes synonyms, breed identifiers/codes, and attributed cross-references to other databases. Conclusion and Clinical Importance The adoption of VBO as a standard for breed names in databases and veterinary electronic health records enhances veterinary data interoperability and computability, supporting precision medicine.

Veterinary Sciences↗

Understanding and applying coulombic efficiency in lithium metal batteries

Coulombic Efficiency (CE) has been widely used in battery research as a quantifiable monitor to compare the properties and performances of materials, electrolytes, interfaces and the entire electrochemical cells. While CE with ultra high precision effectively predicts the lifespan and health for lithium ion (Li-ion) batteries, it is not necessarily true in rechargeable lithium (Li) metal batteries. A large variation of CE is often seen even from the same materials and electrolytes in Li metal cells. This work discusses the fundamental definition of CE in different configurations of Li metal-based cells. The similarities and differences of CE in Li-ion and Li metal cells have been clarified and used to understand the relevance/irrelevance between CE and cycling. Long-standing goal of this study is to help rational design of cell testing protocols and elaborate electrochemical results. The insights from this work are broadly applicable in many other rechargeable metal cells e.g., Zn, Mg and Na batteries to accelerate reseach innovation.

Xiao, Jie↗

Solid-State Personal Dosimetry

This document is a web site page, and a data sheet about Personal protection (i.e., space suits) presented to the Radiation and Micrometeoroid Mitigation Technology Focus Group meeting. The website describes the work of the PI to improve solid state personal radiation dosimetry. The data sheet presents work on the active personal radiation detection system that is to provide real-time local radiation exposure information during EVA. Should undue exposure occur, knowledge of the dynamic intensity conditions during the exposure will allow more precise diagnostic assessment of the potential health risk to the exposed individual.

Wrbanek, John D.↗

State of battery health estimation based on swelling characteristics

There is disclosed an electrical device including a battery, and a battery management system. The battery management system includes a controller in electrical communication with a pressure sensor to monitor the state of health of the battery. The controller applies a method for determining the state of health that uses a non-electrical (mechanical) signal of force measurements combined with incremental capacity analysis to estimate the capacity fading and other health indicators of the battery with better precision than existing methods. The pressure sensor may provide the force measurement signal to the controller, which may determine which incremental capacity curve based on force to use for the particular battery. The controller then executes a program utilizing the data from the pressure sensor and the stored incremental capacity curves based on force to estimate the capacity fading and signal a user with the state of health percentage.

Stefanopoulou, Anna G.↗

The health, climate, and equity benefits of freight truck electrification in the United States

Abstract Long-haul freight shipment in the United States relies on diesel trucks and constitutes ∼3% of U.S. greenhouse gas emissions and a significant share of local air pollution. Here, we compare the climate and air pollution-related health damages from electric versus diesel long-haul truck fleets. We use truck commodity flows to estimate tailpipe emissions from diesel trucks and regional grid emissions intensities to estimate charging emissions from electric trucks under various grid scenarios. We use a reduced complexity air quality model combined with valuation of air pollution-related premature deaths (using two hazard ratios (HRs)) and quantify the distributional health impacts in different scenarios. We find that annual health and climate costs of the current diesel fleet are $195–$249/capita compared to $174–$205/capita for a new diesel fleet, and $156–$177/capita for an electric fleet, depending on the HR. We find that freight electrification could avoid $6.2–8.5 billion in health and climate damages annually when compared to a fleet of new diesel vehicles (with even higher benefits when compared to the current diesel fleet). However, the Midwest and parts of the Gulf Coast would experience an increase in health damages due to vehicles charging using electricity from coal power plants. If old coal power plants (operating in 1980 or earlier) are replaced with zero-emission generation, electrification of all U.S. freight would result in $32.3–39.2 billion in avoided damages annually and health benefits throughout the U.S. Electrifying transport of consumer manufacturing goods (including electronics, transport equipment, and precision instruments) and food, beverage, and tobacco products would provide the largest absolute health and climate benefits, whereas mixed freight and manufacturing goods would result in the largest benefits per tonne-km. We find small variations in health damages across race and income. These results will help policymakers prioritize electrification and charging investment strategies for the freight transportation sub-sector.

Hennessy, Eleanor M. (ORCID:0000000294715765)↗

Structural Mechanism of an Efficacy Photoswitch Targeting the β 2 ‐adrenergic Receptor

The field of photopharmacology develops light-responsive drugs that can modulate protein activity, enabling precise and dynamic investigations of their roles in health and disease. Adrenergic receptors are prominent targets for this approach because they are prototypical G protein-coupled receptors with high clinical relevance in bronchial and cardiovascular diseases. Here, we employed the azobenzene-based compound photoazolol-1 in combination with time-resolved serial crystallography at X-ray free-electron lasers to resolve the molecular mechanisms by which photoswitchable β-blockers modulate activity of the β 2 -adrenoceptor (β 2 AR). Time-resolved structures of the receptor bound to trans-photoazolol-1 (pre-photoconversion), a strained intermediate in the nanosecond range, and the fully photoisomerized cis-photoazolol-1 reveal how isomerization of the azobenzene moiety induces distinct conformational changes within the orthosteric ligand binding pocket. Within seconds, light-excited photoazolol-1 adopts a new binding pose, altering interactions with extracellular loop 2 and shifting the positions of transmembrane helices 5, 6, and 7. Functional assays of β 2 AR in cellular membranes show that photoazolol-1 acts as an efficacy photoswitch, changing from an inverse agonist to a neutral antagonist upon isomerization without leaving the binding pocket. In combination, these findings suggest a molecular mechanism for activity modulation via efficacy photoswitches and provide a framework for designing ligands that exploit light-driven transitions within the binding pocket to achieve spatiotemporal control of receptor function.

G protein-coupled receptors↗