Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proficiency Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automation and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance and mood-state parameters during 30-day 6 degrees head-down bed rest with exercise training

The study was designed to determine if performance and mood impairments occur in bed-rested subjects, and if different exercise-training regimens modify or prevent them. Eighteen normal, healthy men were divided on the basis of age, peak oxygen uptake, and maximal isometric knee extension strength into three similar groups: no exercise (NOE), isotonic exercise (ITE), and isokinetic exercise (IKE). A 15-min battery of 10 performance tests and 8 mood and 2 sleep scales were administered daily during ambulatory control, 30 d of absolute bed rest (BR), and 4 d of ambulatory recovery. Performance test proficiency increased (p < 0.05) for all three groups during BR in 7 of 10 tests and there were no consistent significant differences between the three groups. However, during BR, the ITE group was distinguished from the other groups by a decline (p < 0.05) in the activation mood dimension and in two of its constituent scales (motivation and concentration), and by improvement (p < 0.05) in the trouble-falling-asleep and psychological-tension scales. Since few deleterious changes in performance and mood occurred in the three groups and did not exceed baseline ambulatory levels, we conclude that mood and performance did not deteriorate in response to prolonged BR and were not altered by exercise training. However, the decline in activation mood scales in the ITE group may reflect overtraining or excess total workload in this group.

NASA Center ARC↗

NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive onsite assessment that includes proficiency testing and documentation review. The ATL NVLAP accreditation currently applies specifically to its ISO 3744 soundpower- level determination procedure (see the photograph) and supporting ISO 17025 quality system, although all ATL operations are conducted in accordance with its quality system. The ATL staff is currently developing additional procedures to adapt this quality system to the testing of space flight hardware in accordance with International Space Station acoustic emission requirements.<

Akers, James C.↗

Esterification of 3-quinuclidinol, a marker for the incapacitant BZ, for analysis by EI-GC-MS in OPCW test matrices

The analysis by EI-GC-MS of 3-quinuclidinol (3Q), a marker for the riot control and incapacitating agent quinuclinidyl benzilate (BZ), using several, new acylation strategies is described. After evaluating and optimizing conditions for the acylations, these were tested on their ability to successfully derivatize 3Q in three different matrices featured in the 44th Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test (PT). As 3Q is a highly polar compound, the work here describes acylation strategies that generate 3Q analogs with superior gas chromatographic profiles relative to the underivatized material. The acyl groups studied in this work included acetyl, benzoyl, pentafluorobenzoyl and the bis(3,5-trifluoromethyl)benzoyl. The acylated 3Q products provide sharp, detectable peaks with significantly different retention times from that of the unmodified 3Q. Thus, the retention times for acetyl-, benzoyl-, pentafluorobenzoyl- and 3,5-bis(trifluoromethyl)benzoyl-3Q were determined to be 15.9, 24.9, 22.8 and 22.1 min respectively, in stark contrast to the unmodified 3Q which provides a sharp peak with a retention time centered at ~ 13.5 min only at high concentrations (> 10 µg/mL or µg/g) while a broad peak (RT ~ 15–15.5 min) at low concentrations (< 5 µg/mL or µg/g). The developed protocol was used to derivatize 3Q in three separate matrices. The first two matrices were liquid samples featured during the 44th OPCW PT at two separate concentrations in each (5 and 50 µg/mL). The last matrix was a soil sample featured in the same 44th OPCW PT wherein the 3Q had been spiked at a 12 µg/g concentration. The approach involves the extraction of 3Q from all matrices followed by its acylation resulting in a second reportable analytical method for an OPCW PT. The presented derivatization strategies should find wide applicability particularly in laboratories involved with the analysis of this chemical weapon agent degradation product and those participating in the yearly OPCW PTs.

3-quinuclidinol↗

The 1st International Round-Robin on Bi-Facial Modules

This presentation discusses validation of methods and ensuring the validity of results when testing bifacial PV modules, both of which are requirements in ISO/IEC 17025:2017; electrical parameters to be reported per IEC TS 60904-1-2; and statistical design proficiency testing per ISO 17043.

14 SOLAR ENERGY↗

Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Standard Gear Metrics in Helicopter Flight Operation

Each false alarm made by a machine monitoring system carries a high price tag. The machine must be taken out of service, thoroughly inspected with possible disassembly, and then made ready for service. Loss of use of the machine and the efforts to inspect it are costly. In addition, if a monitoring system is prone to false alarms, the system will soon be turned off or ignored. For aircraft applications, one growing concern is that the dynamic flight environment differs from the laboratory environment where fault detection methods are developed and tested. Vibration measurements made in flight are less stationary than those made in a laboratory, or test facility, and thus a given fault detection method may produce more false alarms in flight than might be anticipated. In 1977. Stewart introduced several metrics, including FM0 and FM4, for evaluating the health of a gear. These metrics are single valued functions of the vibration signal that indicate if the signal deviates from an ideal model of the signal. FM0 is a measure of the ratio of the peak-to-peak level to the harmonic energy in the signal. FM4 is the kurtosis of the signal with the gear mesh harmonics and first order side bands removed. The underlying theory is that a vibration signal from a gear in good condition is expected to be dominated by a periodic signal at the gear mesh frequency. If one or a small number of gear teeth contain damage or faults, the signal will change, possibly showing increased amplitude, local phase changes or both near the damaged region of the gear. FM0 increases if a signal contains a local increase in amplitude. FM4 increases if a signal contains a local increase in amplitude or local phase change in a periodic signal. Over the years, other single value metrics were also introduced to detect the onset and growth of damage in gears. These various metrics have detected faults in several gear tests in experimental test rigs. Conditions in these tests have been steady state in the sense that the rpm, torque and forces on the gear have been held steady. For gears used in a dynamic environment such as that occurring in aircraft, the rpm, torque and forces on the gear are constantly changing. The authors have measured significant variation in rpm and torque in the transmissions of helicopters in controlled steady flight conditions flown by highly proficient test pilots. Statistical analyses of the data taken in flight show significant nonstationarity in the vibration measurements. These deviations from stationarity may increase false alarms in gear monitoring during aircraft flight. In the proposed paper, the authors will study vibration measurements made in flight on an AH- 1 Cobra and an OH-58C Kiowa helicopters. The primary focus will be the development of a methodology to assess the impact of nonstationarity on false alarms. Issues to be addressed include how time synchronous averages are constructed from raw data as well as how lack of stationarity effects the behavior of single value metrics. Emphasis will be placed on the occurrence of false alarms with the use of standard metrics. In order to maintain an acceptable level of false alarms in the flight environment, this study will also address the determination of appropriate threshold levels, which may need to be higher than for test rigs.

Mosher, M.↗

Efficient derivatization of methylphosphonic and aminoethylsulfonic acids related to nerve agents simultaneously in soils using trimethyloxonium tetrafluoroborate for their enhanced, qualitative detection and identification by EI-GC–MS and GC–FPD

Trimethyloxonium tetrafluoroborate (TMO·BF 4 ) has been used here in the simultaneous derivatization of phosphonic and 2-aminoethylsulfonic acids related to nerve agents in different soils for their enhanced detection and identification by electron ionization gas chromatography-mass spectrometry (EI-GC–MS). The panel of acids consisted of five Schedule 2 phosphonic acids (methyl methylphosphonic acid, ethyl methylphosphonic acid, isopropyl methylphosphonic acid, pinacolyl methylphosphonic acid and cyclohexyl methylphosphonic acid) along with two sulfonic acids, N,N-diethyl-2-aminoethylsulfonic acid and N,N-diisopropyl-2-aminoethylsulfonic acid. The acids were converted to their corresponding methyl esters at ambient temperature when present at a 10 μg g -1 concentration in three separate soils: Virginia type A soil, Ottawa sand and Nebraska EPA soil. The concentration of the acids reflects values typically encountered during proficiency tests (PTs) administered annually by the Organisation for the Prohibition of Chemical Weapons (OPCW). Derivatization times to yield detectable signals for the methyl ester products for all the acids was found to vary among all three soil samples, however, it was found that generally the most optimal time across all the matrices involved was 3 h after the addition of TMO·BF 4 . Concomitantly, the analysis of the samples was complemented using GC coupled to flame photometric detection (GC–FPD). The inclusion of GC–FPD in the analysis yielded stronger signals for all seven methylated analytes making their detection after merely 3 h possible relative to the ones initially obtained with EI-GC–MS. Regarding the three soils employed in our study, a greater methylating efficiency was found in the Virginia type A soil and Ottawa sand yielding results that were significantly larger in magnitude to those found during the same time points for the Nebraska EPA soil sample. Prolonged reaction times (up to 72 h) were explored to find the time for the highest yield of methyl ester production were found instead to be deleterious to the process showcasing the importance of the fast yielding nature of the process specifically in situations where time-sensitive analysis is crucial (e.g. OPCW-PT).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbamoylation as an Effective Tool in the Analysis of the Soman Nerve Agent Marker Pinacolyl Alcohol in Soil Matrices by EI-GC-MS and LC-HRMS

Pinacolyl alcohol (PA) is a Schedule 2 chemical commonly featured in most proficiency tests (PTs) administered by the Organisation for the Prohibition of Chemical Weapons (OPCW) due to its direct as well as forensic link to the nerve agent Soman. Therefore, its detection by Chemical Weapons Convention (CWC) inspection teams during on-site investigations is a strong indicator of the past or latent presence of Soman in the environment. Its small molecular weight (102), early elution time, and poor ionization profile make PA a challenging analyte to detect particularly at low concentrations (∼1–10 μg/g). In this work, 1,1′-carbonyldimidazole (CDI) has been used to effectively modify PA for the first time in two different soil matrices (Virginia type A soil and silt sediment) at two separate concentrations (1 and 10 μg/g) for its subsequent detection by EI-GC-MS and LC-HRMS methods. For the EI-GC-MS analysis, the PA carbamate derivative (PIC) exhibits improved chromatography relative to PA such as improved peak shape, increased molecular weight (196 for PIC and 102 for PA) and increased retention time (16.9 min for PIC and ∼4.1 min for PA). In addition, the derivatization also improves the detection of PA by LC-HRMS as the PIC product possesses protonation sites (i.e., imidazole ring) relative to none exhibited by PA. More importantly, the carbamoylation proceeds under mild conditions (55 °C, no base) and rapidly (3 h), characteristics that make it an appealing protocol for the analysis of PA during OPCW PTs or real case scenarios particularly in instances where it is present at low concentrations. It is anticipated that the protocol can be applied to the forensic analysis of this important Soman marker in various environmental matrices.

Chemistry↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Extended Study on the Uncertainty Quantification of a Photodiode's Spectral Responsivity

An extended study was done on the analysis procedure for spectral responsivity of a silicon detector from the range of 200 nm to 1100 nm for the Optical Component Calibration laboratory at Livermore Operations in Livermore California. As a result, the uncertainty of the procedure was quantified to account for variables that contribute to uncertainty; such as the reproducibility and repeatability of the working standards, quantifying Type A and B uncertainties, validating laboratory equipment and associated software, and looking at environmental variables. The findings lead to a revised analysis reporting procedure that reports uncertainties depending on three spectral ranges, 300 nm to 400 nm, 400 nm to 700 nm, and 700 nm to 1100 nm. A proficiency test was done to compare the difference between both methods and a noticeable difference was found. The results showed that the previous reporting method over estimated uncertainty as much as 3.5% for the 300 nm to 400 nm range, 4% in the >400 nm to 700 nm range, and 2% in the >700 nm to 1100 nm range. The findings lead to the use of the revised procedure when producing calibration certificates, better quantified measurement uncertainties, and will be used for the process of updating the scope of accreditation from the National Voluntary Laboratory Accreditation Program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NWAL Validation Report for U Assay by Potentiometric Titration (Modified Davies and Gray Technique) and U and PU Assay by Isotope Dilution Mass Spectrometry

SRNL Sensing & Metrology, previously Analytical Laboratory, is a member of the IAEA Network of Analytical Laboratories for Nuclear Material Measurement that is qualified to provide Uranium and Plutonium isotopic analysis of nuclear materials by Thermal Ionization Mass Spectrometry. As part of the membership, SRNL participated in the 2019 Nuclear Material Round Robin to maintain the qualification to provide isotopic analysis. SRNL also participated with the additional intent to qualify Uranium Assay by Potentiometric Titration (Davies and Gray method) and Uranium and Plutonium Isotope Dilution by Thermal Ionization Mass Spectrometry as part of the International Atomic Energy Agency’s Network of Analytical Laboratories. The proficiency test exercise was conducted by the Office of Safeguards Analytical Services, Department of Safeguards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Training Materials for Pathologists to Provide Machine Learning Validation Data of Tumor-Infiltrating Lymphocytes in Breast Cancer

The High Throughput Truthing project aims to develop a dataset for validating artificial intelligence and machine learning models (AI/ML) fit for regulatory purposes. The context of this AI/ML validation dataset is the reporting of stromal tumor-infiltrating lymphocytes (sTILs) density evaluations in hematoxylin and eosin-stained invasive breast cancer biopsy specimens. After completing the pilot study, we found notable variability in the sTILs estimates as well as inconsistencies and gaps in the provided training to pathologists. Using the pilot study data and an expert panel, we created custom training materials to improve pathologist annotation quality for the pivotal study. We categorized regions of interest (ROIs) based on their mean sTILs density and selected ROIs with the highest and lowest sTILs variability. In a series of eight one-hour sessions, the expert panel reviewed each ROI and provided verbal density estimates and comments on features that confounded the sTILs evaluation. We aggregated and shaped the comments to identify pitfalls and instructions to improve our training materials. From these selected ROIs, we created a training set and proficiency test set to improve pathologist training with the goal to improve data collection for the pivotal study. We are not exploring AI/ML performance in this paper. Instead, we are creating materials that will train crowd-sourced pathologists to be the reference standard in a pivotal study to create an AI/ML model validation dataset. The issues discussed here are also important for clinicians to understand about the evaluation of sTILs in clinical practice and can provide insight to developers of AI/ML models.

60 APPLIED LIFE SCIENCES↗

The three R's of training: Recording, Retaining, and Reporting - The training management system that synergizes

NASA's Kennedy Space Center employs a Training and Certification Record System (TCRS) which tracks and maintains records for each of its employees, encompassing all aspects of training history: training courses, physical examinations, proficiency tests, on-the-job training, standboards, and certifications with completions and expiration dates. TCRS, which is fully automated, includes an expiration-alert notification capability to project recurring expirations, thereby functioning as a forecasting tool for training budgets.

Ingram, Dick D.↗

Approach to Quality Assurance for Complex Environmental Modeling - 20407

A strong Quality Assurance (QA) program for complex environmental modeling is essential for regulatory and public acceptance and trust, but it does not have to be onerous. Neptune and Company, Inc. (Neptune) has developed a strong QA program that improves transparency, traceability, reproducibility, and therefore, defensibility and trust. Neptune's QA program has evolved over the past 27 years, transitioning from an ad hoc QA program, to a program that is currently Nuclear Quality Assurance-1 (NQA-1) compliant, and will soon be NQA-1/DOE approved for DOE EM modeling work. In addition, Neptune is a qualified laboratory assessor and qualified auditor for reference materials, a proficiency testing provider, and fully complies with the Environmental Protection Agency (EPA) QA program. Neptune's President and CEO, Kelly Black, was recently named the Chairperson of the International Organization for Standardization (ISO) Technical Committee 69, Application of Statistical Methods. A strong QA program has been developed for Neptune's radiological performance assessment (PA) program. Although pieces of their QA program are currently in development, their current program includes document control using Subversion, issue tracking and work flow tracking using JIRA, and transparency and traceability via a system of 'calc sheets' for documentation of all data analysis and modeling combined with 'check print' documentation of QA checking, and rigorous model testing and configuration control. All work is reviewed by an independent subject matter expert who is not associated with the collection and assembly of information, for an internal peer review. The program is enforced with a handful of Standard Operation Procedures (SOPs), Work Instructions, QA Project Plans (QAPPs), and Quality Management Plans (QMPs) that are updated frequently, with required annual training and acknowledgment. In addition, effective communication of modeling approaches and results to clients and stakeholders are integral to their QA program. Many of their models are built using the GoldSim modeling platform, for which their models are well-known for their level of transparency, documentation, and QA traceability. This level of QA is also applied to their process-level models. Neptune has taken some lessons learned from the extremely rigorous QA program required for the Yucca Mountain Project (YMP), and imposed the YMP requirements of complete traceability, transparency, and reproducibility, but avoided the inflexibility of a QA program that likely contributed to the suspect e-mails in 2005 that resulted in loss of trust in the YMP, and in nuclear waste disposal (and nuclear power) in general. There are far too many examples of loss of public trust due to poor QA that could have been easily avoided with a simple and straight-forward QA program combined with stakeholder engagement. The purpose of this paper is to share features of Neptune's Radiological Performance Assessment program QA program, and some of their QA related lessons learned over the past 27 years of QA for complex environmental modeling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine learning for continuous quantum error correction on superconducting qubits

Abstract Continuous quantum error correction has been found to have certain advantages over discrete quantum error correction, such as a reduction in hardware resources and the elimination of error mechanisms introduced by having entangling gates and ancilla qubits. We propose a machine learning algorithm for continuous quantum error correction that is based on the use of a recurrent neural network to identify bit-flip errors from continuous noisy syndrome measurements. The algorithm is designed to operate on measurement signals deviating from the ideal behavior in which the mean value corresponds to a code syndrome value and the measurement has white noise. We analyze continuous measurements taken from a superconducting architecture using three transmon qubits to identify three significant practical examples of non-ideal behavior, namely auto-correlation at temporal short lags, transient syndrome dynamics after each bit-flip, and drift in the steady-state syndrome values over the course of many experiments. Based on these real-world imperfections, we generate synthetic measurement signals from which to train the recurrent neural network, and then test its proficiency when implementing active error correction, comparing this with a traditional double threshold scheme and a discrete Bayesian classifier. The results show that our machine learning protocol is able to outperform the double threshold protocol across all tests, achieving a final state fidelity comparable to the discrete Bayesian classifier.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Savannah River National Laboratory Participation in the International Atomic Energy Agency CPC Interlaboratory Comparison Exercise 2

International Atomic Energy Agency Safeguards Analytical Services (IAEA-SGAS) oversees coordinating the second Controlled Potential Coulometry Quality Control Interlaboratory Comparison (CPC QC ILC) on behalf of the Nuclear Material Laboratory (NML). The purpose of the exercise is to: (1) verify the ability of participating laboratories to measure the Pu concentration in the sample solutions, and (2) estimate the method performance (repeatability and intermediate reproducibility). Sample shipping coordination was performed by IAEA-SGAS. The test sample is a plutonium nitrate solution (estimated molarity of 3-5 M), delivered in two PTFE screw-capped quartz ampoules. Each participating laboratory is to receive two ampoules. Each ampoule holds approximately 8 mL of solution containing approximately 10 mg Pu/g. The gross weights of the ampoules were provided. The test sample is assumed to have an iron content below the level of significance for the CPC. The isotopic composition of the plutonium test sample was provided; however, no analysis date was provided. In addition, IAEA-SGAS provided analytical instructions to participants. On September 20, 2022, SRNL received the samples sent by IAEA-SGAS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗