Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proficiency testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

OPCW Twining Project Visit by the National Laboratory of Scientific and Technical Police (LNPST) to Lawrence Livermore National Laboratory Forensic Science Center (LLNL)

PURPOSE FOR TRIP Through the Organisation for Prohibition of Chemical Weapons (OPCW) Twinning and Assistance Program, Lawrence Livermore National Laboratory, Forensic Science Center (LLNL) has been paired with Morocco’s National Laboratory of Scientific and Technical Police (LNPST), with the goal of mentoring LNPST to become an OPCW Designated Laboratory. The purpose of this visit was for LLNL staff to mentor staff from LNPST as they participated in hands-on, laboratory-based exercises to analyze proficiency test samples prepared by LLNL. This visit was designed to help LNPST scientists strengthen their skills in OPCW proficiency testing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Code Comparison Study Fosters Confidence in the Numerical Simulation of Enhanced Geothermal Systems

Numerical simulation has become a standard analytical tool for scientists and engineers to evaluate the potential and performance of enhanced geothermal systems. A variety of numerical simulators developed by industry, universities, and national laboratories are currently available and being applied to better understand enhanced geothermal systems at the field scale. To yield credible predictions and be of value to site operators, numerical simulators must be able to accurately represent the complex coupled processes induced by producing geothermal systems, such as fracture aperture changes due to thermal stimulation, fracture shear displacement with fluid injection, rate of thermal depletion of reservoir rocks, and permeability alteration with mineral precipitation or dissolution. A suite of numerical simulators was exercised on a series of test problems that considered coupled thermal, hydraulic, geomechanical, and geochemical (THMC) processes. Problems were selected and designed to isolate selected coupled processes, to be executed on workstation class computers, and have simple but illustrative metrics for result comparisons. This paper summarizes the initial suite of seven benchmark problems, describes the code comparison activities, provides example results for problems and documents the capabilities of currently available numerical simulation codes to represent coupled processes that occur during the production of geothermal resources. Code comparisons described in this paper use the ISO (International Organization for Standardization) standard ISO-13538 for proficiency testing of numerical simulators. This approach was adopted for a recent code comparison study within the radiation transfer-modeling field of atmospheric sciences, which was focused on canopy reflectance models. This standard specifies statistical methods for analyzing laboratory data from proficiency testing schemes to demonstrate that the measurement results do not exhibit evidence of an unacceptable level of bias.

benchmark problems↗

Effective methylation of phosphonic acids related to chemical warfare agents mediated by trimethyloxonium tetrafluoroborate for their qualitative detection and identification by gas chromatography-mass spectrometry

The effective methylation of phosphonic acids related to chemical warfare agents (CWAs) employing trimethyloxonium tetrafluoroborate (TMO·BF 4 ) for their qualitative detection and identification by gas chromatography-mass spectrometry (GC-MS) is presented. The methylation occurs in rapid fashion (1 h) and can be conveniently carried out at ambient temperature, thus providing a safer alternative to the universally employed diazomethane-based methylation protocols. Optimization of the methylation parameters led us to conclude that methylene chloride was the ideal solvent to carry out the derivatization, and that even though methylated products can be observed surfacing after only 1 h, additional time was not found to be detrimental but beneficial to the process particularly when dealing with analytes at low concentrations (~10 μg mL -1 ). Due to its insolubility in methylene chloride, TMO·BF 4 conveniently settles to the bottom during the reaction and does not produce additional interfering by-products that may further complicate the GC-MS analysis. We demonstrated the method to successfully methylate a variety of Schedule 2 phosphonic acids, including their half esters, resulting in derivatives that were readily detected and identified using the instrument's spectral library. Most importantly, the method was shown to simultaneously methylate a mixture of the organophosphorus-based nerve agent hydrolysis products: pinacolyl methylphosphonate (PMPA), cyclohexyl methylphosphonate (CyMPA) and ethyl methylphosphonate (EMPA) (at a 10 μg mL - 1 concentration each) in a fatty acid ester-rich organic matrix (OPCW-PT-O 3 ) featured in the 38th Organisation for the Prohibition of Chemical Weapons (OPCW) Proficiency Test. Additionally, the protocol was found to effectively methylate N,N-diethylamino ethanesulfonic acid and N,N-diisopropylamino ethanesulfonic acid that are products arising from the oxidative degradation of the V-series agents VR and VX respectively. This work described herein represents the first report on the use of TMO·BF 4 as a viable, stable and safe agent for the methylation of phosphonic acids and their half esters and within the context of an OPCW Proficiency Test sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - Statistical Analysis of RDX Standard Data Sets

The Integrated Data Collection Analysis (IDCA) program is conducting a Proficiency Test for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard. The material was tested as a well-characterized standard several times during the proficiency study to assess differences among participants and the range of results that may arise for well-behaved explosive materials. The analyses show that there are detectable differences among the results from IDCA participants. While these differences are statistically significant, most of them can be disregarded for comparison purposes to assess potential variability when laboratories attempt to measure identical samples using methods assumed to be nominally the same. The results presented in this report include the average sensitivity results for the IDCA participants and the ranges of values obtained. The ranges represent variation about the mean values of the tests of between 26% and 42%. The magnitude of this variation is attributed to differences in operator, method, and environment as well as the use of different instruments that are also of varying age. The results appear to be a good representation of the broader safety testing community based on the range of methods, instruments, and environments included in the IDCA Proficiency Test.

round-robin test↗

Integrated Data Collection Analysis (IDCA) Program - Final Review September 12, 2012 at DHS

The Integrated Data Collection Analysis (IDCA) program conducted a final program review at the Department of Homeland Security on September 12, 2012. The review was focused on the results of the program over the complete performance period. A summary presentation delineating the accomplished tasks started the meeting, followed by technical presentations on various issues that arose during the performance period. The presentations were completed with a statistical evaluation of the testing results from all the participants in the IDCA Proficiency Test study. The meeting closed with a discussion of potential sources of funding for continuing work to resolve some of these technical issues. This effort, funded by the Department of Homeland Security (DHS), put the issues of safe handling of these materials in perspective with standard military explosives. The study added Small-Scale Safety and Thermal (SSST) testing results for a broad suite of different HMEs to the literature, and suggested new guidelines and methods to develop safe handling practices for HMEs. Each participating testing laboratory used identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results were compared among the laboratories and then compared to historical data from various sources. The testing performers involved were Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Naval Surface Warfare Center, Indian Head Division (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory, Tyndall AFB (AFRL/RXQL). These tests were conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automation and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Esterification of 3-quinuclidinol, a marker for the incapacitant BZ, for analysis by EI-GC-MS in OPCW test matrices

The analysis by EI-GC-MS of 3-quinuclidinol (3Q), a marker for the riot control and incapacitating agent quinuclinidyl benzilate (BZ), using several, new acylation strategies is described. After evaluating and optimizing conditions for the acylations, these were tested on their ability to successfully derivatize 3Q in three different matrices featured in the 44th Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test (PT). As 3Q is a highly polar compound, the work here describes acylation strategies that generate 3Q analogs with superior gas chromatographic profiles relative to the underivatized material. The acyl groups studied in this work included acetyl, benzoyl, pentafluorobenzoyl and the bis(3,5-trifluoromethyl)benzoyl. The acylated 3Q products provide sharp, detectable peaks with significantly different retention times from that of the unmodified 3Q. Thus, the retention times for acetyl-, benzoyl-, pentafluorobenzoyl- and 3,5-bis(trifluoromethyl)benzoyl-3Q were determined to be 15.9, 24.9, 22.8 and 22.1 min respectively, in stark contrast to the unmodified 3Q which provides a sharp peak with a retention time centered at ~ 13.5 min only at high concentrations (> 10 µg/mL or µg/g) while a broad peak (RT ~ 15–15.5 min) at low concentrations (< 5 µg/mL or µg/g). The developed protocol was used to derivatize 3Q in three separate matrices. The first two matrices were liquid samples featured during the 44th OPCW PT at two separate concentrations in each (5 and 50 µg/mL). The last matrix was a soil sample featured in the same 44th OPCW PT wherein the 3Q had been spiked at a 12 µg/g concentration. The approach involves the extraction of 3Q from all matrices followed by its acylation resulting in a second reportable analytical method for an OPCW PT. The presented derivatization strategies should find wide applicability particularly in laboratories involved with the analysis of this chemical weapon agent degradation product and those participating in the yearly OPCW PTs.

3-quinuclidinol↗

The 1st International Round-Robin on Bi-Facial Modules

This presentation discusses validation of methods and ensuring the validity of results when testing bifacial PV modules, both of which are requirements in ISO/IEC 17025:2017; electrical parameters to be reported per IEC TS 60904-1-2; and statistical design proficiency testing per ISO 17043.

14 SOLAR ENERGY↗

Validating the Melusine Gamma Spectroscopy Tool

This technical report describes testing to evaluate the gamma spectroscopy tool, Melusine, under development by Pacific Northwest National Laboratory. The goal was to verify that the software can successfully be used to provide accurate results and statistical uncertainties for the detection of isotopes of interest and their activities. Of special interest were spectra similar to those produced by radionuclide stations that contribute to the Comprehensive Nuclear Test Ban Treaty Organization’s International Monitoring System. Two data sets were used to test Melusine’s capabilities. The first was the result of a multi-lab calibration effort based on neutron activations produced at the University of California at Davis. The second was taken from the Proficiency Test Exercises conducted by the CTBTO directly in 2005. In 37 of 42 cases, Melusine produced results in agreement with the best answer presently available, in most cases with calculated uncertainties comparable to or better than competing analyses. In fact, Melusine technically provided one more result than CTBTO’s PTE analyses that agreed with the “book answer” (Monte Carlo simulation). Despite these promising results, the Melusine software is still under development. Effort is especially needed to simplify its analysis process, improve stability, and provide user documentation. Some significant analysis tasks require further vetting, such as those to address summing effects. However, our test results indicate that Melusine’s calculations as presently implemented are sound and can be used to reliably analyze spectra from the CTBTO’s radionuclide stations.

CTBTO↗

Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rapid separation and purification of uranium and plutonium from dilute-matrix samples

This work presents a streamlined separation and purification approach for trace uranium and plutonium from dilute (carrier-free) matrices. The method, effective for nanogram quantities of U and femtogram to picogram quantities of Pu, is ideally suited for environmental swipe samples that contain a small amount of collected bulk material. As such, it may be applicable for processing swipe samples such as those collected in IAEA inspection activities as well as swipes that are loaded with unknown analytes, such as those implemented in interlaboratory round-robin or proficiency tests. Additionally, the simplified actinide separation could find use in internal laboratory monitoring of clean room conditions prior to or following more extensive chemical processing. We describe key modifications to conventional techniques that result in a relatively rapid, cost-effective, and efficient U and Pu separation process. We demonstrate the efficacy of implementing anion exchange chromatography in a single column approach. We also show that hydrobromic acid is an effective substitute in lieu of hydroiodoic acid for eluting Pu. Lastly, we show that nitric acid is an effective digestion agent in lieu of perchloric acid and/or hydrofluoric acid. A step by step procedure of this process is detailed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Localized accumulation of lead within and among bones from lead-dosed goats

The principal aim of this study was to gain a better understanding of where lead (Pb) accumulates and how it is distributed, within the bones of dosed goats. Adult goats were periodically dosed with Pb over a number of years for the primary purpose of producing blood pools containing endogenously bound Pb, for the New York State Blood Lead Proficiency Testing Program. Bone samples (e.g., primarily tibia, femur, humerus, and radius) were collected post-mortem from 11 animals and were analyzed for Pb content by acid digestion and electrothermal atomic absorption spectrometry (ETAAS or GFAAS). Average tibia Pb levels were found to correlate strongly with the cumulative Pb dose (r{sup 2}=0.81). However, the concentration of Pb in different bones and even within a small area of the same bone varied tremendously. Blood-rich trabecular (spongy) bone, such as the patella and calcaneus, were much more enriched in Pb than was cortical (compact) bone. In some dosed animals, the Pb concentration in the tibia was markedly higher at the proximal and distal ends of the bone compared to the mid-shaft. The implications of these findings with regard to the noninvasive measurement of lead in bone by XRF methods are discussed.

60 APPLIED LIFE SCIENCES↗

Efficient derivatization of methylphosphonic and aminoethylsulfonic acids related to nerve agents simultaneously in soils using trimethyloxonium tetrafluoroborate for their enhanced, qualitative detection and identification by EI-GC–MS and GC–FPD

Trimethyloxonium tetrafluoroborate (TMO·BF 4 ) has been used here in the simultaneous derivatization of phosphonic and 2-aminoethylsulfonic acids related to nerve agents in different soils for their enhanced detection and identification by electron ionization gas chromatography-mass spectrometry (EI-GC–MS). The panel of acids consisted of five Schedule 2 phosphonic acids (methyl methylphosphonic acid, ethyl methylphosphonic acid, isopropyl methylphosphonic acid, pinacolyl methylphosphonic acid and cyclohexyl methylphosphonic acid) along with two sulfonic acids, N,N-diethyl-2-aminoethylsulfonic acid and N,N-diisopropyl-2-aminoethylsulfonic acid. The acids were converted to their corresponding methyl esters at ambient temperature when present at a 10 μg g -1 concentration in three separate soils: Virginia type A soil, Ottawa sand and Nebraska EPA soil. The concentration of the acids reflects values typically encountered during proficiency tests (PTs) administered annually by the Organisation for the Prohibition of Chemical Weapons (OPCW). Derivatization times to yield detectable signals for the methyl ester products for all the acids was found to vary among all three soil samples, however, it was found that generally the most optimal time across all the matrices involved was 3 h after the addition of TMO·BF 4 . Concomitantly, the analysis of the samples was complemented using GC coupled to flame photometric detection (GC–FPD). The inclusion of GC–FPD in the analysis yielded stronger signals for all seven methylated analytes making their detection after merely 3 h possible relative to the ones initially obtained with EI-GC–MS. Regarding the three soils employed in our study, a greater methylating efficiency was found in the Virginia type A soil and Ottawa sand yielding results that were significantly larger in magnitude to those found during the same time points for the Nebraska EPA soil sample. Prolonged reaction times (up to 72 h) were explored to find the time for the highest yield of methyl ester production were found instead to be deleterious to the process showcasing the importance of the fast yielding nature of the process specifically in situations where time-sensitive analysis is crucial (e.g. OPCW-PT).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residual Agar Determination in Bacterial Spores by Electrospray Ionization Mass Spectrometry

Presented here is an analytical method to detect residual agar from a bacterial spore sample as an indication of culturing on an agar plate. This method is based on the resolubilization of agar polysaccharide from a bacterial spore sample, enzymatic digestion, followed by electrospray ionization tandem mass spectrometry (ESI-MSn) analysis for detection of a specific agar fragment ion. A range of Bacillus species and strains were selected to demonstrate the effectiveness of this approach. The characteristic agar fragment ion was detected in the spores grown on agar that were washed from 1 to 5 times, irradiated or non-irradiated and not in the spores grown in broth. A sample containing approximately 108 spores is currently needed for confident detection of residual agar from culture on agar plates in the presence of bacterial spores with a limit of detection of approximately 1 ppm agar spiked into a broth-grown spore sample. The results of a proficiency test with 42 blinded samples are presented demonstrating the utility of this method with no false positives and only 3 false negatives for samples that were below the detection level of the method as documented.

59 BASIC BIOLOGICAL SCIENCES↗

Carbamoylation as an Effective Tool in the Analysis of the Soman Nerve Agent Marker Pinacolyl Alcohol in Soil Matrices by EI-GC-MS and LC-HRMS

Pinacolyl alcohol (PA) is a Schedule 2 chemical commonly featured in most proficiency tests (PTs) administered by the Organisation for the Prohibition of Chemical Weapons (OPCW) due to its direct as well as forensic link to the nerve agent Soman. Therefore, its detection by Chemical Weapons Convention (CWC) inspection teams during on-site investigations is a strong indicator of the past or latent presence of Soman in the environment. Its small molecular weight (102), early elution time, and poor ionization profile make PA a challenging analyte to detect particularly at low concentrations (∼1–10 μg/g). In this work, 1,1′-carbonyldimidazole (CDI) has been used to effectively modify PA for the first time in two different soil matrices (Virginia type A soil and silt sediment) at two separate concentrations (1 and 10 μg/g) for its subsequent detection by EI-GC-MS and LC-HRMS methods. For the EI-GC-MS analysis, the PA carbamate derivative (PIC) exhibits improved chromatography relative to PA such as improved peak shape, increased molecular weight (196 for PIC and 102 for PA) and increased retention time (16.9 min for PIC and ∼4.1 min for PA). In addition, the derivatization also improves the detection of PA by LC-HRMS as the PIC product possesses protonation sites (i.e., imidazole ring) relative to none exhibited by PA. More importantly, the carbamoylation proceeds under mild conditions (55 °C, no base) and rapidly (3 h), characteristics that make it an appealing protocol for the analysis of PA during OPCW PTs or real case scenarios particularly in instances where it is present at low concentrations. It is anticipated that the protocol can be applied to the forensic analysis of this important Soman marker in various environmental matrices.

Chemistry↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - KClO 4 /Aluminum Mixture

The Integrated Data Collection Analysis (IDCA) program is conducting a Proficiency Test for Small-Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and aluminum—KClO 4 /Al mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solids. The mixture was found to be: 1) much less sensitive to impact than RDX, (LLNL being the exception) and PETN, 2) more sensitive to friction than RDX and PETN, and 3) extremely sensitive to spark. The thermal analysis showed little or no exothermic character. One prominent endothermic feature was observed in the temperature range studied and identified as a phase transition of KClO 4 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Extended Study on the Uncertainty Quantification of a Photodiode's Spectral Responsivity

An extended study was done on the analysis procedure for spectral responsivity of a silicon detector from the range of 200 nm to 1100 nm for the Optical Component Calibration laboratory at Livermore Operations in Livermore California. As a result, the uncertainty of the procedure was quantified to account for variables that contribute to uncertainty; such as the reproducibility and repeatability of the working standards, quantifying Type A and B uncertainties, validating laboratory equipment and associated software, and looking at environmental variables. The findings lead to a revised analysis reporting procedure that reports uncertainties depending on three spectral ranges, 300 nm to 400 nm, 400 nm to 700 nm, and 700 nm to 1100 nm. A proficiency test was done to compare the difference between both methods and a noticeable difference was found. The results showed that the previous reporting method over estimated uncertainty as much as 3.5% for the 300 nm to 400 nm range, 4% in the >400 nm to 700 nm range, and 2% in the >700 nm to 1100 nm range. The findings lead to the use of the revised procedure when producing calibration certificates, better quantified measurement uncertainties, and will be used for the process of updating the scope of accreditation from the National Voluntary Laboratory Accreditation Program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗