Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Double nanosecond pulses generation in ytterbium fiber laser

Double pulse generation mode for nanosecond ytterbium fiber laser was developed. Two sequential 60-200 ns laser pulses with variable delay between them were generated by acousto-optic modulator opening with continuous diode pumping. A custom radio frequency generator was developed to produce two sequential “opening” radio pulses with a delay of 0.2–1 μs. It was demonstrated that double pulse generation did not decrease the average laser power while providing the control over the laser pulse power profile. Surprisingly, a greater peak power in the double pulse mode was observed for the second laser pulse. Laser crater studies and plasma emission measurements revealed an improved efficiency of laser ablation in the double pulse mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single attosecond pulse generation from multicycle nonlinear chirped pulses

We present a method of producing single attosecond pulses by high-order harmonic generation with multicycle nonlinear chirped driver laser pulses. The symmetry of the laser field in several optical cycles near the pulse center is broken, and then the photons near the cutoff burst only in half optical cycle. By selecting out the harmonics near the cutoff, an isolated attosecond pulse could be obtained. The results are almost independent of the length and chirp form of the driver laser pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terahertz pulse generation from noble gases

Terahertz pulse generation in the laser-induced plasma from a series of noble gases (He, Ne, Ar, Kr, and Xe) was systematically investigated. Femtosecond laser pulses consisting of both a fundamental and its second-harmonic frequency were used for the terahertz generation. Experimental results reveal that terahertz generation efficiency of these noble gases increases with decreasing ionization potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of High Voltage Bipolar Pulse Generator with Fast Push-Pull Solid-State Switch Modules

Four identical pulse generators (pulsers) provide fast beam deflection in the Low Energy Beam Transport (LEBT) beam chopping system at the Spallation Neutron Source (SNS) Linac. The existing pulsers have become obsolete and need to be replaced to improve overall performance of the chopper system. A new bipolar pulse generator has been designed, and a prototype has been built and tested at the SNS. The generator uses fast push-pull transistor BEHLKE switch modules. It can produce a 1MHz burst of alternate 2.5kV with adjustable pulse widths during the 1-ms macro-pulse at a burst repetition frequency of 60Hz with rise/fall times of less than 40ns into a 100pF capacitive load. The performance enhancements of this new pulser in comparison with existing and previous versions of the pulse generator are discussed in the paper. The pulser can be used in applications requiring a series of bipolar ±3.5kV pulses, or unipolar pulses of positive or negative polarity with amplitude up to 4.5kV and various pulse widths with a minimum of 150ns. The maximum switching frequency, number of pulses, or burst repetition frequency in burst mode is limited by maximum power dissipation in the switches and other components. The features of this new pulser along with the results of timing control adjustments, timing and temperature measurements, and HV full power testing on the test stand are presented.

Peplov, Vladimir↗

Development of a 100 kV pulse generator for driving an electron scanner used in proton beam profile measurements

The Spallation Neutron Source (SNS) utilizes an electron scanner in the accumulator ring for nondestructive transverse profiling of the proton beam. The electron scanner consists of a high voltage pulse generator driving an electron gun, a medium voltage ramp generator, and a CCD camera. A new high voltage pulse generator that provides negative 100 kV pulses with rise times of less than 200 ns, +/-0.5% flattop of greater than 100 ns has been designed, delivered, and undergone extensive testing. The pulse generator has been operationally verified with the existing control system and simulated loads. Full system testing with the actual electron scanner is planned. This paper details the requirements, design, setup, and test results of the high voltage pulse generator.

Morris, B↗

Coiled transmission line pulse generators

Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

McDonald, Kenneth Fox↗

High-Precision Pulse Generator

A document discusses a pulse generator with subnanosecond resolution implemented with a low-cost field-programmable gate array (FPGA) at low power levels. The method used exploits the fast carry chains of certain FPGAs. Prototypes have been built and tested in both Actel AX and Xilinx Virtex 4 technologies. In-flight calibration or control can be performed by using a similar and related technique as a time interval measurement circuit by measuring a period of the stable oscillator, as the delays through the fast carry chains will vary as a result of manufacturing variances as well as the result of environmental conditions (voltage, aging, temperature, and radiation).

Katz, Richard↗

X-ray pulse generation with ultra-fast flipping of its orbital angular momentum

A method to temporally tailor the properties of X-ray radiation carrying Orbital Angular Momentum (OAM) is presented. In simulations, an electron beam is prepared with a temporally modulated micro-bunching structure which, when radiating at the second harmonic in a helical undulator, generates OAM light with a corresponding temporally modulated intensity. This method is shown to generate attosecond pulse trains of OAM light without the need for any additional external optics, making the wavelength range tunable. In addition to the OAM pulse train, the method can be adapted to generate radiation where the handedness of the OAM mode may also be temporally modulated (flipped).

43 PARTICLE ACCELERATORS↗

Single attosecond pulse generation in an orthogonally polarized two-color laser field combined with a static electric field

We investigate theoretic high-order harmonic generation and single attosecond pulse generation in an orthogonally polarized two-color laser field, which is synthesized by a mid-infrared (IR) pulse (12.5 fs, 2000 nm) in the y component and a much weaker (12 fs, 800 nm) pulse in the x component. We find that the width of the harmonic plateau can be extended when a static electric field is added in the y component. We also investigate emission time of harmonics in terms of a time-frequency analysis to illustrate the physical mechanism of high-order harmonic generation. We calculate the ionization rate using the Ammosov-Delone-Krainov model and interpret the variation of harmonic intensity for different static electric field strengths. When the ratio of strengths of the static and the y-component laser fields is 0.1, a continuous harmonic spectrum is formed from 220 to 420 eV. By superposing a properly selected range of the harmonic spectrum from 300 to 350 eV, an isolated attosecond pulse with a duration of about 75 as is obtained, which is near linearly polarized.

74 ATOMIC AND MOLECULAR PHYSICS↗

A comparison between characteristics of atmospheric-pressure plasma jets sustained by nanosecond- and microsecond-pulse generators in helium

Power source is an important parameter that can affect the characteristics of atmospheric-pressure plasma jets (APPJs), because it can play a key role on the discharge characteristics and ionization process of APPJs. In this paper, the characteristics of helium APPJs sustained by both nanosecond-pulse and microsecond-pulse generators are compared from the aspects of plume length, discharge current, consumption power, energy, and optical emission spectrum. Experimental results showed that the pulsed APPJ was initiated near the high-voltage electrode with a small curvature radius, and then the stable helium APPJ could be observed when the applied voltage increased. Moreover, the discharge current of the nanosecond-pulse APPJ was larger than that of the microsecond-pulse APPJ. Furthermore, although the nanosecond-pulse generator consumed less energy than the microsecond-pulse generator, longer plume length, larger instantaneous power per pulse and stronger spectral line intensity could be obtained in the nanosecond-pulse excitation case. In addition, some discussion indicated that the rise time of the applied voltage could play a prominent role on the generation of APPJs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pattern generator circuit for high-speed pulse generation

A pattern generator circuit includes a high-speed shift register and a non-overlap generator. The shift register is programmable to produce a pulse train of pulses having a defined pulse duration and a defined pulse-to-pulse interval. The non-overlap generator deserializes the incoming pulse train, and it produces a time-separated reset pulse based on the pulse train. The shift register is configured to permit the pulse durations and pulse-to-pulse interval to be selected arbitrarily over specified ranges in increments of a basic time unit that depends on the oscillator period.

42 ENGINEERING↗

Recent progress in picosecond pulse generation from semiconductor lasers

This paper reviews the recent progress in producing picosecond optical pulses from semiconductor laser diodes. The discussion concentrates on the mode-locking of a semiconductor laser diode in an external resonator. Transform-limited optical pulses ranging from several picoseconds to subpicosecond durations have been observed with active and passive mode-locking. Even though continuing research on the influence of impurities and defects on the mode-locking process is still needed, this technique has good promise for being utilized in fiber-optic communication systems. Alternative methods of direct electrical and optical excitation to produce ultrashort laser pulses are also described. They can generate pulses of similar widths to those obtained by mode-locking. The pulses generated will find applications in laser ranging and detector response measurement.

Auyeung, J. C.↗

Submonolayer Quantum-Dot Based Saturable Absorber for Femtosecond Pulse Generation

Semiconductor saturable absorber mirrors (SESAMs) enable passive modelocking of several ultrafast solid-state lasers. Conventionally, SESAMs in the 1-µm wavelength range have employed InGaAs quantum wells (QWs) as absorbers. Here we demonstrate a SESAM based on InAs/GaAs submonolayer quantum dots (SML QDs) capable of generating femtosecond pulses by passively modelocking a vertical-external-cavity surface-emitting laser (VECSEL). Structural measurements are carried out to verify the quality and composition of the QDs. Modelocking experiments with a VECSEL and the QD SESAM in a ring cavity configuration yield pulses as short as 185 fs at 1025 nm. Compared to a traditional QW absorber, SML QD SESAMs exhibit ~ 25% faster recovery times. This also translates to slower power degradation rates or higher damage thresholds in SML QD SESAMs.

36 MATERIALS SCIENCE↗