Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse pileup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

26 records · Page 2

Pulse shape discrimination in CUPID-Mo using principal component analysis

CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. It uses 20 scintillating $^{100}$Mo-enriched Li$_2$MoO$_4$ bolometers instrumented with Ge light detectors to perform active suppression of $\alpha$ backgrounds, drastically reducing the expected background in the $0\nu\beta\beta$ signal region. As a result, pileup events and small detector instabilities that mimic normal signals become non-negligible potential backgrounds. These types of events can in principle be eliminated based on their signal shapes, which are different from those of regular bolometric pulses. We show that a purely data-driven principal component analysis based approach is able to filter out these anomalous events, without the aid of detector response simulations.

47 OTHER INSTRUMENTATION↗

Non-Equilibrium Doping of Poly-Si:Ga/SiOx Passivating Contacts Solar Cells

In this contribution, we show that Ga-hyperdoped poly-Si/SiOx contacts are realized by pulsed laser annealing and post-hydrogenation. The motivation behind this work is to improve the inferior performance of boron-doped poly- Si/SiOx contacts when compared to the phosphorus-doped contacts. Here we used Ga as a novel p-type dopant to replace B, as B is known to accumulate at the interface between the oxide and the crystalline silicon and cause recombination. Due to a high diffusivity of Ga in oxide and a much higher segregation coefficient (Si:SiOx), Ga is shown to be immune to the oxide pileup phenomenon. However, Ga has a low solid solubility limit in Si (5x10^19 cm-3), which is not enough to form a low resistivity contact. To overcome this problem, we explored pulsed laser annealing via excimer laser by varying the laser energy densities and pulses. The passivation and electrical properties are studied systematically using photoluminescence (PL), secondary ion mass spectrometry (SIMS), and Van der Pauw-Hall measurements. We show an active Ga doping concentration above 1x10^20 cm^-3, which is above the solid solubility limit of Ga in Si. Good passivation quality is demonstrated with the highest implied Voc (iVoc) of 721 mV on single side polished samples. Furthermore, a low diode contact resistivity of ~22 m..omega.. cm^2 is obtained using Ti/Ag contacts, with minimal metal-to-semiconductor contact resistivity of 0.9 m..omega.. cm^2.

non-equilibrium doping↗

Correcting x ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

Correcting X-ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters, correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

Novel technique for the study of pileup events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetohydrodynamics in free surface liquid metal flow relevant to plasma-facing components

Abstract While flowing Liquid Metal (LM) Plasma-Facing Components (PFCs) represent a potentially transformative technology to enable long-pulse operation with high-power exhaust for fusion reactors, Magnetohydrodynamic (MHD) drag in the conducting LM will reduce the flow speed. Experiments have been completed in the linear open-channel LMX-U device [Hvasta et al 2018 Nucl. Fusion 58 01602] for validation of MHD drag calculations with either insulating or conducting walls, with codes similar to those used to design flowing LM PFCs for a Fusion Nuclear Science Facility [Kessel et al 2019 Fusion Sci. Technol . 75 886]. We observe that the average channel flow speed decreased with the use of conducting walls and the strength of the applied transverse magnetic field. The MHD drag from the retarding Lorentz force resulted in an increase of the LM depth in the channel that ‘piled up’ near the inlet, but not the outlet. As reproduced by OpenFOAM and ANSYS CFX calculations, the magnitude and characteristics of the pileup in the flow direction increased with the applied traverse magnetic field by up to 120%, as compared to the case without an applied magnetic field, corresponding to an average velocity reduction of ∼45%. Particle tracking measurements confirmed a predicted shear in the flow speed, with the surface velocity increasing by 300%, despite the 45% drop in the average bulk speed. The MHD effect makes the bulk flow laminarized but keeps surface waves aligned along the magnetic field lines due to the anisotropy of MHD drag. The 3D fringe field and high surface velocity generate ripples around the outlet region. It was also confirmed that the MHD drag strongly depends on the conductivity of the channel walls, magnetic field, and volumetric flow rate, in agreement with the simulations and a developed analytical model. These validated models are now available to begin to determine the conditions under which the ideal LM channel design of a constant flow speed and fluid depth could be attained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an MCP-Based Timing Layer for the LHCb ECAL Upgrade-2

The increase in instantaneous luminosity during the high-luminosity phase of the LHC represents a significant challenge for future detectors. A strategy to cope with high-pileup conditions is to add a fourth dimension to the measurements of the hits, by exploiting the time separation of the various proton–proton primary collisions. According to LHCb simulation studies, resolutions of about 10–20 picoseconds, at least an order of magnitude shorter than the average time span between primary interactions, would be greatly beneficial for the physics reach of the experiment. Microchannel plate (MCP) photomultipliers are compact devices capable of measuring the arrival time of charged particles with the required resolution. The technology of large-area picosecond photodetectors (LAPPDs) is under investigation to implement a timing layer that can be placed within a sampling calorimeter module with the purpose of measuring the arrival time of electromagnetic showers. LAPPD performances, using a Gen-I tile with a delay-line anode and a Gen-II with a capacitively coupled anode, have been measured thoroughly both with laser (wavelength of 405 nm and pulse width of 27.5 ps FWHM) and high-energy electron (1–5.8 GeV) beams. Time resolutions of the order of 30 ps for single photoelectrons and 15 ps for electromagnetic showers initiated by 5-GeV electrons, as measured at the shower maximum, are obtained.

47 OTHER INSTRUMENTATION↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗