Search NASASearch

SEARCH · Search NASA

Results for “Pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Exploring high-intensity laser-driven secondary sources via high-order spectral pulse shaping for high-energy-density experiments

We present here the results of an investigation that aims to explore the impact of spectral pulse shaping on the generation of high-energy electrons (>1 MeV) and x rays (∼5–9 keV) using a high-intensity (I∼10 21 W/cm 2 ) laser system. The study involved a systematic scan of a broad parameter space in group delay dispersion and third-order dispersion, with variations up to 4 × 10 3 fs −2 and 6 × 10 4 fs −3 , respectively, to identify optimal conditions for enhancing secondary source yields. Several spectral phase conditions were found to significantly enhance the generation of hot electrons and x rays by amounts reaching up to 50% relative to the transform-limited pulse. The experiment, conducted at the Scarlet laser facility (800 nm, 5 J, 30 fs) at the Ohio State University, highlights the potential of spectral pulse shaping as a powerful tool for tuning secondary laser-driven sources. These findings are particularly relevant for advancing brighter x-ray and electron probes for high-energy-density science.

Physics - Plasma physics

Performance stability of plastics for neutron-gamma pulse shape discrimination

The introduction of the first commercially available plastic scintillators with pulse shape discrimination (PSD) offered by Eljen Technology marked progress towards potentially replacing liquid scintillators in neutron detection. However, use of these plastics over several recent years has revealed an important flaw in these materials: the eventual degradation of scintillation light output and PSD performance. Here, studies described in this paper considered possible reasons for this degradation. Experiments conducted with numerous lab-prepared and commercial EJ-276 samples showed that the main factor affecting the instability is oxidation that involves highly reactive radicals generated during the polymerization process or from the further breakdown of polymer chains under oxygen/air exposure. Based on the obtained results, the stability of scintillation performance for PPO (2,5-Diphenyloxazole)-based PSD plastics has been improved through modifications of the composition via the utilization of scintillation dyes and compounds with antioxidant properties that diminish the effects of oxidation. Elements of these studies were used in the commercial production of the most recent EJ-276D PSD plastic version for fast neutron detection and 6Li-loaded plastics for thermal neutron and antineutrino detection applications. Performance projections of the new PSD plastics indicate a likely degradation of less than 10 % over 5–10 years in comparison to previous EJ-276 that might lose up to 30–40 % of the scintillation light during 1–2 years of storage or deployment under ambient conditions.

36 MATERIALS SCIENCE

Average 2-6 keV pulse shapes of Hercules X-1 during the January 1972 'on' state

The available data on the Uhuru satellite sightings of observably bright ('on' state) Her X-1 during January 1972 are divided into eight intervals between successive eclipses. The average pulse shapes obtained are discussed. It is shown that the average pulse shape varies little during most of the 'on' state. However, during about the last three days of the 'on' state, the pulsations almost completely disappear. The results appear to support a class of models in which the 35-day cycle is due to variable obscuration of Her X-1 by a precessing accretion disk or other matter within the system.

Joss, P. C.

On-chip pulse shaping of entangled photons

The miniaturization of optical systems via integrated photonics is critical to the ultimate scalability and performance of photonic quantum processors, yet many longstanding optical signal processing capabilities—such as Fourier-transform pulse shaping—remain unrealized on chip. In this work, we demonstrate on-chip spectral shaping of entangled photons using a multichannel microring-resonator-based silicon photonic pulse shaper. Achieving line-by-line phase control on a 3 GHz grid for two frequency-bin-entangled qudits, the pulse shaper's fine spectral resolution enables control of nanosecond-scale temporal features, which are observed by direct coincidence detection of biphoton correlation functions that show excellent agreement with theory. This work marks a demonstration of biphoton pulse shaping using an integrated spectral shaper and holds significant promise for applications in photonic quantum information processing.

Entanglement manipulation

Prototype reactor-antineutrino detector based on 6 Li-doped pulse-shape-discriminating plastic scintillator

An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 6 ⁢Li-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with 6 ⁢Li at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-𝛽-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. Here, this paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.

Physics

Performance of large-scale 6 Li-doped pulse-shape discriminating plastic scintillators

A 6 Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ -299-50, has been developed and produced at the kilogram-scale. A total of 44 bars of dimensions 5.5 cm x 5.5 cm x 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to 6 Li-doped liquid scintillators. Further, the scintillator EJ -299-50 shows good neutron detection capabilities with an effective efficiency for capture on 6 Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Application of digital pulse shaping by least squares method to ultrasonic signals in composites

For ultrasonic testing in composites, a signal processing tool is identified that can significantly enhance the sharpness of ultrasonic waveforms and provide clearer pictures of the nature of the material flaw. The technique artificially improves the resolution of the system to discrete events by pulse shaping the measured waveform based on the signal from a reference. The optimum pulse shape operator is determined from a least-squares method in the z-domain.

Kishoni, D.

The 35 day dependence of the pulse shape of Hercules X-1

An interesting finding regarding the pulse shape change of Hercules X-1 is reported. By inspecting Her X-1 observations made by various detectors over various epochs, it is found that during the decay phase of the 35-day cycle high state the first-peak flux (of the double-peaked main pulse) is attenuated more than the second-peak flux. Accepting that the 35-day cycle is a consequence of the wobbling of the accretion disk, a model is proposed in which the first-peak emission and the second-peak emission emanate from two different emitting regions (two magnetic poles). According to this model, during the decay phase of the 35-day cycle the column density of the coronal gas along the line of sight to the first-peak emission region is greater than that to the second-peak emission region. Thus the Compton scattering attenuation of the first peak is larger at a given moment during the decay phase. Implications of the model are discussed.

Bai, T.

A generalization of MSK-type signaling based upon input data symbol pulse shaping

Minimum-shift-keying (MSK), which is a special case of continuous phase frequency-shift-keying (CPFSK) with frequency deviation ratio equal to 0.5, is known to be spectrally equivalent to a form of offset quadrature phase-shift-keying (OQPSK) in which the symbol pulse shape is a half-cycle sinusoid rather than the usual rectangular form. Appropriate shaping of the input data symbols allows one to generate an entire class of constant envelope, MSK-type signals, whose spectral properties are in some applications more desirable than those of MSK or OQPSK. The present study derives and presents a set of conditions on the input pulse shaping which in turn describes the class of envelope shapes allowable. The autocorrelation function and power spectral density of this class of signals are then derived, and specific examples are given to illustrate the desirable spectral properties. Such properties are important considerations in system design where interchannel and intersymbol interference degradations must be kept to a minimum.

Simon, M. K.

Bayesian optimization of laser wakefield acceleration via spectral pulse shaping

In this paper, we investigate the effect of spectral pulse shaping of the laser driver on the performance of channel-guided, laser–plasma accelerators. The study was carried out with the assistance of Bayesian optimization using particle-in-cell simulations. We used a realistic plasma profile based on a novel optical-field-ionized channel technique with ionization injection and low, on-axis plasma densities to maximize the energy gain of the electron bunch trailing the laser. Spectral shaping allows us to modify the temporal profile of the laser driver while keeping the laser energy constant, affecting the acceleration and injection processes. In addition, we consider how modifying the plasma channel parameters may affect the target outputs. Given the complexity and breadth of the parameter space in question, we used numerical optimization to identify high-performing configurations. In particular, we found laser profiles with additional spectral content that, when used with optimal plasma channel parameters, result in charge content an order of magnitude higher than the baseline Gaussian case while also increasing the mean energy of the electron bunch.

Physics - Plasma physics

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as $15\%$. For specific background processes such as $^{124}$Xe double electron capture, the leakage is reduced further to about $5\%$. PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ's WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]

Pushing the limits of pulse shape discrimination in a large liquid xenon detector

Abstract The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing tail fraction discriminator is optimized and achieves ER leakage as low as $$15\%$$ 15 % . For specific background processes such as $$^{124}$$ 124 Xe double electron capture, the leakage is reduced further to about $$5\%$$ 5 % . PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ’s WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC National Accelerator Laborator

Influence of phase cancellation and pulse shape artifacts on ultrasonic spectrum analysis

Both continuous wave and Fourier transformed pulse ultrasonic spectroscopy are being applied to material and flow characterization. Ideal samples and flaws (flat, parallel, and homogeneous) and ideal ultrasonic apparatus (producing delta function stress waves) provide acoustic spectra which can be partially inverted. However, in the presence of material inhomogeneity, lack of sample flatness or parallelism, or finite risetime pulses, the spectra become quite complex and produce phase cancellations at the transducer as well as pulse shape spectral artifacts. In this paper, we examine the nature of these artifacts for both simple and practical samples. Sample spectra are contrasted for several different transducer/electronic systems. Spectra obtained with a phase insensitive acousto-electric transducer (AET) combined with a frequency tracked tone-burst spectroscopy (TBS) method are presented. Analysis of the test configuration is shown to produce spectra consistent with that obtained with the AET-TBS combination.

Heyman, J. S.

Long-Term Time Variability in the X-Ray Pulse Shape of the Crab Nebula Pulsar

This is the final performance report for our grant 'Long-Term Time Variability in the X-Ray Pulse Shape of the Crab Nebula Pulsar.' In the first year of this grant, we received the 50,000-second ROSAT (German acronym for X-ray satellite) High Resolution Images (HRI) observation of the Crab Nebula pulsar. We used the data to create a 65-ms-resolution pulse profile and compared it to a similar pulse profile obtained in 1991. No statistically significant differences were found. These results were presented at the January 1998 meeting of the American Astronomical Society. Since then, we have performed more sensitive analyses to search for potential changes in the pulse profile shape between the two data sets. Again, no significant variability was found. In order to augment this long (six-year) baseline data set, we have analyzed archival observations of the Crab Nebula pulsar with the Rossi X-Ray Timing Explorer (RXTE). While these observations have shorter time baselines than the ROSAT data set, their higher signal-to-noise offers similar sensitivity to long-term variability. Again, no significant variations have been found, confirming our ROSAT results. This work was done in collaboration with Prof. Stephen Eikenberry, Cornell University. These analyses will be included in Cornell University graduate student Dae-Sik Moon's doctoral thesis.

Fazio, Giovanni G.

Laser-Modulation-Driven X-Ray Pulse Shaping in Regenerative Amplifier Free-Electron Lasers

In this Letter, we present a robust method for generating custom-shaped, coherent hard x-ray pulses in regenerative amplifier free-electron lasers (RAFELs) using laser-induced energy modulation of the electron beam. A temporally shaped optical modulation imprints an optical-wavelength energy pattern on the beam, which interacts with the recirculated seed in the x-ray cavity to generate spectral sidebands. These sidebands lie outside the Bragg reflection bandwidth and are extracted as out-coupled radiation, while the seed is retained for continued amplification, enabling a novel mechanism for both output coupling and pulse shaping. Furthermore, this approach allows deterministic control over the spectral and temporal properties of the emitted x-rays, including multicolor generation, twin-pulse structures, pulse duration tuning, and complex temporal waveforms. Importantly, it does not require modification of the RAFEL cavity or optics and is fully compatible with high-repetition-rate operation, offering a practical pathway to deliver coherent, shaped, and on-demand x-ray pulses for advanced time-resolved and nonlinear x-ray science.

Free-electron lasers

The experimental cascade curves of EAS at E sub 0 10(17) eV obtained by the method of detection of Cherenkov pulse shape

The individual cascade curves of EAS with E sub 0 10 to the 17th power eV/I to 3/ were studied by detection of EAS Cherenkov light pulses. The scintillators located at the center of the Yakutsk EAS array within a 500-m radius circle were used to select the showers and to determine the main EAS parameters. The individual cascade curves N(t) were obtained using the EAS Cherenkov light pulses satisfying the following requirements: (1) the signal-to-noise ratio fm/delta sub n 15, (2) the EAS axis-detector distance tau sub 350 m, (3) the zenith angle theta 30 deg, (4) the probability for EAS to be detected by scintillators W 0.8. Condition (1) arises from the desire to reduce the amplitude distortion of Cherenkov pulses due to noise and determines the range of EAS sizes, N(t). The resolution times of the Cherenkov pulse shape detectors are tau sub 0 approx. 23 ns which results in distortion of a pulse during the process of the detection. The distortion of pulses due to the finiteness of tau sub 0 value was estimated. It is shown that the rise time of pulse becomes greater as tau sub 0.5/tau sub 0 ratio decreases.

Fomin, Y. A.