At least 37 records · Page 2

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of Quantum Approximate Optimization Algorithm on HPC-QC Integrated Systems

The Quantum Approximate Optimization Algorithm (QAOA) has emerged as a promising tool for accelerating optimization processes in the Noisy Intermediate-Scale Quantum (NISQ) era. Compared to classical methods, QAOA efficiently solves optimization problems, often formulated as Quadratic Unconstrained Binary Optimization (QUBO) problems. Classical quantum simulators are crucial for evaluating quantum algorithms due to limited quantum resources. However, QAOA's performance can vary with different simulation methods. This study analyzes QAOA's performance using various quantum simulators (e.g., density _matrix, statevector, and matrix_product_state) and demonstrates the benefits of HPC-QC integrated systems in solving QUBO problems on an active learning workflow. By simulating QAOA on dense, large-matrix QUBO problems, we evaluate accuracy and problem-solving time. We also assess QAOA's performance on local computers and HPC-QC inte-grated systems, using Oak Ridge Leadership Computing Facility (OLCF)'s Frontier supercomputer with local Qiskit Aer and remote IBM Quantum simulators.

Kim, Seongmin [ORNL] (ORCID:0000000159063004)↗

SU-F-T-567: Sensitivity and Reproducibility of the Portal Imaging Panel for Routine FFF QC and Patient Plan Dose Measurements

Purpose: The purpose of this work was to see if the EPID is a viable alternative to other QA devices for routine FFF QA and plan dose measurements. Methods: Sensitivity measurements were made to assess response to small changes in field size and beam steering. QA plans were created where field size was varied from baseline values (5–5.5cm, 20–20.5cm). Beam steering was adjusted by altering values in service mode (Symmetry 0–3%). Plans were measured using the Varian portal imager (aS1200 DMI panel), QA3 (Sun Nuclear), and Starcheck Maxi (PTW). FFF beam parameters as stated in Fogliata et al were calculated. Constancy measurements were taken using all 3 QC devices to measure a MLC defined 20×20cm field. Two clinical SABR patient plans were measured on a Varian Edge linac, using the Portal Dosimetry module in ARIA, and results compared with analysis made using Delta4 (ScandiDos). Results: The EPID and the Starcheck performed better at detecting clinically relevant changes in field size with the QA3 performing better when detecting similar changes in beam symmetry. Consistency measurements with the EPID and Starcheck were equivalent, with comparable standard deviations. Clinical plan measurements on the EPID compared well with Delta4 results at 3%/1mm. Conclusion: Our results show that for FFF QA measurements such as field size and symmetry, using the EPID is a viable alternative to other QA devices. The EPID could potentially be used for QC measurements with a focus on geometric accuracy, such as MLC positional QA, due to its high resolution compared to other QA devices (EPID 0.34mm, Starcheck 3mm, QA3 5mm). Good agreement between Delta4 and portal dosimetry also indicated the EPID may be a suitable alternative for measurement of clinical plans.

60 APPLIED LIFE SCIENCES↗

QC-GN2OMS2

The QC-GN2OMS2 neural network was designed to predict mass spectra better than currently available approaches. Fundamentally the neural net is designed to input the structure of a molecule and collision energy value then output a spectra datafile for the end user. This software is able to make predictions orders of magnitude faster (milliseconds) than QC methods and with 50-60% greater accuracy than rules approaches.

Overstreet, Richard↗

ORNL Data Compilation for the IAEA CRP-6 QC Benchmark Exercise

Four TRISO-coated particle samples were subjected to a battery of quality control (QC) measurements typically used at Oak Ridge National Laboratory for characterization and acceptance testing of coated particle fuel. The results of the analysis will be compared to similar analyses performed by the other participants in a QC benchmark exercise as part of the International Atomic Energy Agency (IAEA) Coordinated Research Project number 6 (CRP-6). The samples in the study were all produced on zirconia spheres as a surrogate material for the uranium bearing fuel kernel. Four of the participating organizations supplied these surrogate fuel samples. The sample suppliers were 1) the Babcock and Wilcox Company (B&W) in the USA, 2) the Korea Atomic Energy Research Institute (KAERI) in South Korea, 3) Pebble Bed Modular Reactor Ltd. in South Africa, and 4) the Oak Ridge National Laboratory (ORNL) in the USA. It should be stressed that the purpose of this exercise is for the comparison and benchmarking of the characterization methods and results. These surrogate coated particles ar enot necessarily representative of the baseline process used by each organization and conclusions should not be drawn regarding fuel performance based on the properties of these samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Defining quantum-ready primitives for hybrid HPC-QC supercomputing: a case study in Hamiltonian simulation

As computational demands in scientific applications continue to rise, hybrid high-performance computing (HPC) systems integrating classical and quantum computers (HPC-QC) are emerging as a promising approach to tackling complex computational challenges. One critical area of application is Hamiltonian simulation, a fundamental task in quantum physics and other large-scale scientific domains. This paper investigates strategies for quantum-classical integration to enhance Hamiltonian simulation within hybrid supercomputing environments. By analyzing computational primitives in HPC allocations dedicated to these tasks, we identify key components in Hamiltonian simulation workflows that stand to benefit from quantum acceleration. To this end, we systematically break down the Hamiltonian simulation process into discrete computational phases, highlighting specific primitives that could be effectively offloaded to quantum processors for improved efficiency. Our empirical findings provide insights into system integration, potential offloading techniques, and the challenges of achieving seamless quantum-classical interoperability. We assess the feasibility of quantum-ready primitives within HPC workflows and discuss key barriers such as synchronization, data transfer latency, and algorithmic adaptability. These results contribute to the ongoing development of optimized hybrid solutions, advancing the role of quantum-enhanced computing in scientific research.

97 MATHEMATICS AND COMPUTING↗

WE-D-BRD-03: Novel Methods and Tools for MR Commissioning and QC

The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.

60 APPLIED LIFE SCIENCES↗

The Development of QC Standards for ARM Data Products

While the overall object of the Atmospheric Radiation Measurement (ARM) program, to study cloud formation processes and their influence on radiative transfer, has not changed since the program’s inception in 1992 [1], the challenges associated with and the methods applied to ensure ARM data is of “known and reasonable” quality have evolved as the program has matured. This paper describes an effort initiated in 2005 to create standards to guide the creation, formatting, and assessment of QC in ARM Value-Added Products (VAPs). It includes background on the motivation and process for creating the standards, a description of the requirements defined to guide the development of the standards, the standards themselves, and tools created to verify VAP data products properly adhere to the standards.

54 ENVIRONMENTAL SCIENCES↗

Illumina GA IIx& HiSeq 2000 Production Sequenccing and QC Analysis Pipelines at the DOE Joint Genome Institute

The U.S. Department of Energy (DOE) Joint Genome Institute's (JGI) Production Sequencing group is committed to the generation of high-quality genomic DNA sequence to support the mission areas of renewable energy generation, global carbon management, and environmental characterization and clean-up. Within the JGI's Production Sequencing group, a robust Illumina Genome Analyzer and HiSeq pipeline has been established. Optimization of the sesequencer pipelines has been ongoing with the aim of continual process improvement of the laboratory workflow, reducing operational costs and project cycle times to increases ample throughput, and improving the overall quality of the sequence generated. A sequence QC analysis pipeline has been implemented to automatically generate read and assembly level quality metrics. The foremost of these optimization projects, along with sequencing and operational strategies, throughput numbers, and sequencing quality results will be presented.

59 BASIC BIOLOGICAL SCIENCES↗

DSTL HMEX Reference QC Bounds Generation Using 2023 TP89 and Water Scans [Slides]

This presentation covers the results of new QC bounds generated using data from 10 TP89 reference specimen scans and 30 water scans acquired between January 12 and February 2, 2023. All scan data were acquired on the DSTL HMEX MCT system (in lead cabinet). All data presented were from DSTL’s reconstructions of recent HMEX scans.

42 ENGINEERING↗

Fundamental Algorithmic Research for Quantum Computing (FAR‐QC) (Final report)

This document is the final technical report for the "Fundamental Algorithmic Research for Quantum Computing" (FAR-QC) project at Dartmouth College (PI: J. Whitfield, co-PI: L. Viola). It details the project's primary scientific accomplishments from 2019 to 2025, focusing on advances in quantum simulation algorithms, resource-efficient fermionic encodings, bosonic topology, and optimization methods for near-term quantum devices. The report also summarizes project impacts, including software development (Quiqbox.jl), workforce training, and a complete list of resulting publications.

97 MATHEMATICS AND COMPUTING↗