Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hunting Data Rogues at Scale: Data Quality Control for Observational Data in Research Infrastructures

Data quality control is one of the most time consuming activities within Research Infrastructures (RIs), especially when involving observational data and multiple data providers. In this work we report on our ongoing development of data rogues, a scalable approach to manage data quality issues for observational data within RIs. The motivation for this work started with the creation of the FLUXNET2015 dataset, which includes carbon, water, and energy fluxes plus micrometeorological and ancillary data measured in over 200 sites around the world. To create an uniform dataset, including derived data products, extensive work on data quality control was needed. The unpredictable nature of observational data quality issues makes the automation of data quality control inherently difficult. Developed based on this experience, the data rogues methodology allows for increased automation of quality control activities by systematically identifying, cataloging, and documenting implementations of solutions to data issues. We believe this methodology can be extended and applied to others domains and types of data, making the automation of data quality control a more tractable problem.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Quality control education in the community college

This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

Greene, J. Griffen↗

Many roads may lead to Rome: Selected features of quality control within environmental assessment systems in the US, NL, CA, and UK

As there is no one-and-only concept on how to precisely define and establish quality control (QC) or quality assurance (QA) in the making of environmental assessments (EA), this paper presents selected features of international approaches that address quality in EA systems in the USA, the Netherlands, Canada, and the United Kingdom. Based on explanative case studies, we highlight the embedding of specific quality control features within the EA systems, the objectives and processes, and relevant transparency challenges. Such features of QC/QA approaches can be considered in cases where substantial quality control and assurance efforts are still missing. Yet further research needs to be conducted on the efficacy of these approaches, which remains beyond the scope of this study. - Highlights: • We present four tools for quality control and assurance from different EA systems. • Approaches vary in institutional setting, objectives, procedures, and transparency. • Highlighted features might provide guidance in cases where QC/QA is still lacking.

54 ENVIRONMENTAL SCIENCES↗

SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool

Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs at 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant from Varian Medical Systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

WELDSMART: A vision-based expert system for quality control

This work was aimed at exploring means for utilizing computer technology in quality inspection and evaluation. Inspection of metallic welds was selected as the main application for this development and primary emphasis was placed on visual inspection, as opposed to other inspection methods, such as radiographic techniques. Emphasis was placed on methodologies with the potential for use in real-time quality control systems. Because quality evaluation is somewhat subjective, despite various efforts to classify discontinuities and standardize inspection methods, the task of using a computer for both inspection and evaluation was not trivial. The work started out with a review of the various inspection techniques that are used for quality control in welding. Among other observations from this review was the finding that most weld defects result in abnormalities that may be seen by visual inspection. This supports the approach of emphasizing visual inspection for this work. Quality control consists of two phases: (1) identification of weld discontinuities (some of which may be severe enough to be classified as defects), and (2) assessment or evaluation of the weld based on the observed discontinuities. Usually the latter phase results in a pass/fail judgement for the inspected piece. It is the conclusion of this work that the first of the above tasks, identification of discontinuities, is the most challenging one. It calls for sophisticated image processing and image analysis techniques, and frequently ad hoc methods have to be developed to identify specific features in the weld image. The difficulty of this task is generally not due to limited computing power. In most cases it was found that a modest personal computer or workstation could carry out most computations in a reasonably short time period. Rather, the algorithms and methods necessary for identifying weld discontinuities were in some cases limited. The fact that specific techniques were finally developed and successfully demosntrated to work illustrates that the general approach taken here appears to be promising for commercial development of computerized quality inspection systems. Inspection based on these techniques may be used to supplement or substitute more elaborate inspection methods, such as x-ray inspections.

Andersen, Kristinn↗

Mitochondrial quality control pathways: PINK1 acts as a gatekeeper

Highlights: • A well-defined network of mitochondria quality control processes are required to maintain a functional and healthy pool of mitochondria within the cells. • Activation of proteins involved in mitochondrial quality control pathways, such as Parkin, Mfn2, DRP1 and Miro; is regulated by the mitochondrial kinase PINK1. • It is proposed that PINK1 acts as a gatekeeper of mitochondrial quality control mechanisms. Mitochondria have a pivotal role in the maintenance of cell homeostasis and survival. Mitochondria are involved in processes such as ATP production, reactive oxygen species production, apoptosis induction, calcium homeostasis and protein degradation. Thus, mechanisms that regulate the intrinsic quality of mitochondria have a crucial role in dictating overall cell fate. The importance of these well-regulated mechanisms is highlighted in disease scenarios such as neurodegeneration, cancer and neuromuscular atrophy. How mitochondria senses and regulates their intrinsic quality control, and consequently cell survival, is still not fully understood. In this review, we discuss the pathways that are at present considered as state-of-the-art for mitochondria quality control regulation, and highlight a mitochondrial protein–PINK1–that has revealed to act as a mitochondrial gatekeeper able to sense the presence of healthy or damaged mitochondria.

60 APPLIED LIFE SCIENCES↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems

Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.

60 APPLIED LIFE SCIENCES↗

SU-E-T-103: Development and Implementation of Web Based Quality Control Software

Purpose: Historically many radiation medicine programs have maintained their Quality Control (QC) test results in paper records or Microsoft Excel worksheets. Both these approaches represent significant logistical challenges, and are not predisposed to data review and approval. It has been our group's aim to develop and implement web based software designed not just to record and store QC data in a centralized database, but to provide scheduling and data review tools to help manage a radiation therapy clinics Equipment Quality control program. Methods: The software was written in the Python programming language using the Django web framework. In order to promote collaboration and validation from other centres the code was made open source and is freely available to the public via an online source code repository. The code was written to provide a common user interface for data entry, formalize the review and approval process, and offer automated data trending and process control analysis of test results. Results: As of February 2014, our installation of QAtrack+ has 180 tests defined in its database and has collected ∼22 000 test results, all of which have been reviewed and approved by a physicist via QATrack+'s review tools. These results include records for quality control of Elekta accelerators, CT simulators, our brachytherapy programme, TomoTherapy and Cyberknife units. Currently at least 5 other centres are known to be running QAtrack+ clinically, forming the start of an international user community. Conclusion: QAtrack+ has proven to be an effective tool for collecting radiation therapy QC data, allowing for rapid review and trending of data for a wide variety of treatment units. As free and open source software, all source code, documentation and a bug tracker are available to the public at https://bitbucket.org/tohccmedphys/qatrackplus/.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quality control and crop characterization framework for multi-temporal UAV LiDAR data over mechanized agricultural fields

Recent developments in remote sensing are enabling automatic, high resolution, and non-destructive survey of agriculture fields, providing the key basis for advancing plant breeding. Among the used remote sensing modalities, LiDAR has attracted wide attention for its ability to directly provide accurate 3D information. Despite the increasing utilization of LiDAR technology in phenotyping, there is still a lack of effective quality control strategies, in particular, quality control of LiDAR data collected on a multi-temporal basis. This study proposes a targetless framework for multi-temporal LiDAR data quality control and crop characterization in mechanized agricultural fields. Features extracted from the fields – terrain patches and row/alley locations – are utilized for evaluating the vertical and planimetric relative accuracy of the point clouds. Row/alley locations in the field are automatically identified from the point clouds based on the assumption that higher point density and/or higher elevation correspond to plant locations. The performance of the proposed quality control strategies is evaluated using multi-temporal datasets collected in agricultural fields of different sizes, orientation, crops, and growth stages. The result shows that the net vertical and planimetric discrepancies between multi-temporal point clouds are ±3 cm and ±8 cm, respectively. While the former reflects the actual accuracy of the point clouds, the latter is a combined effect of the LiDAR point cloud accuracy, rasterization artifacts, crop type, growth pattern, and wind condition during data acquisition. In terms of row and alley detection, the result shows that the proposed strategy achieves high performance and can deal with different planting orientation, crop types, growth stages, canopy cover, and planting density. In conclusion, this study presents a quality control framework for multi-temporal LiDAR data. Finally, the row and alley detection leads to automated extraction of plots, and hence facilitates the use of remotely sensed data for automated phenotyping.

54 ENVIRONMENTAL SCIENCES↗

Application of the BSRN Data in Validating the GEWEX SRB Data: Quality-Control and Resulting Available Monthly Means

The BSRN data have been used in validation of the satellite-based GEWEX SRB data, and the recent Release 4.0-IP data cover the 34-year period from July 1983 to June 2017. Here we focus on the validation of the shortwave monthly means from 1992 to 2017 against the BSRN Global 1. We first perform the BSRN-recommended quality-control on the original data. We then calculate the monthly-hourly means from which we calculate the monthly means. Twenty-four (24) monthly-hourly means are required to calculate a monthly mean. To guarantee the quality of the monthly mean, we also require that 95% or more hourly means be available in order for a monthly-hourly mean to be calculated. Since the above quality-control significantly reduces the number of available monthly means, we are curious how many monthly means we would get if we relax the quality-control, and how the resulting monthly means would compare with the GEWEX SRB data. In a version we experimented, only constant upper and lower bounds are imposed on various fluxes, and the original data are largely retained. We found that many more monthly means would be available, and the overall bias and RMS would not be significantly different from that of the strict quality-control. With the strict quality-control, if we let Avail (minimum percentage of available hourly means required for a monthly-hourly mean to be computed) change from 3.2% to 95%, the Bias/RMS/N change from -2.77/20.56/9756 to -0.35/13.41/4581, where N is the number of available monthly means, and Bias and RMS are in the unit of W/sq. m. On the other hand, with the lax quality-control, when Avail changes from 3.2% to 95%, the Bias/RMS/N change from -0.82/19.53/9819 to -0.21/14.41/5875. South Pole (SPO) is one of the sites we are particularly interested in. With the strict quality-control, and when Avail changes from 3.2% to 95%, the Bias/RMS/N change from 5.89/15.85/283 to 1.23/5.52/133; with the lax quality-control, the Bias/RMS/N change from 1.17/11.21/284 to 1.88/7.9/177.

Taiping Zhang↗

Spectroscopic Investigation of Catalyst Inks and Thin Films Toward the Development of Ionomer Quality Control

As the production of polymer electrolyte fuel cells expands, novel quality control methods must be invented or adapted in order to support expected rates of production. Ensuring the quality of deposited catalyst layers is an essential step in the fuel cell manufacturing process, as the efficiency of a fuel cell is reliant on the catalyst layer being uniform at both the target platinum loading and the target ionomer content. Implementing a quality control method that is sensitive to these aspects is imperative, as wasting precious metals and other catalyst materials is expensive, and represents a potential barrier to entry into the field for manufacturers experimenting with novel deposition processes. In this work, we analyzed catalyst inks to determine if their ionomer content could be quantized spectroscopically. Attenuated total reflection (ATR) Fourier transform infrared spectroscopic technique was investigated producing a signal proportional to the ionomer content. ATR spectroscopy was able to quantitatively differentiate samples in which the ionomer to carbon mass ratio (I/C) varied between 0.9 and 3.0. The I/C ratio was correlated to the measured ATR signal near the CF 2 vibrational bands located between 1100 cm −1 and 1400 cm −1 . The experimental results obtained constitute a step toward the development of novel quality control methodologies for catalyst inks utilized by the fuel cell industry.

30 DIRECT ENERGY CONVERSION↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data Assimilation Experiments using Quality Controlled AIRS Version 5 Temperature Soundings

The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AlRS data. Version 5 contains accurate case-by-case error estimates for most derived products, which are also used for quality control. We have conducted forecast impact experiments assimilating AlRS quality controlled temperature profiles using the NASA GEOS-5 data assimilation system, consisting of the NCEP GSI analysis coupled with the NASA FVGCM. Assimilation of quality controlled temperature profiles resulted in significantly improved forecast skill in both the Northern Hemisphere and Southern Hemisphere Extra-Tropics, compared to that obtained from analyses obtained when all data used operationally by NCEP except for AlRS data is assimilated. Experiments using different Quality Control thresholds for assimilation of AlRS temperature retrievals showed that a medium quality control threshold performed better than a tighter threshold, which provided better overall sounding accuracy; or a looser threshold, which provided better spatial coverage of accepted soundings. We are conducting more experiments to further optimize this balance of spatial coverage and sounding accuracy from the data assimilation perspective. In all cases, temperature soundings were assimilated well below cloud level in partially cloudy cases. The positive impact of assimilating AlRS derived atmospheric temperatures all but vanished when only AIRS stratospheric temperatures were assimilated. Forecast skill resulting from assimilation of AlRS radiances uncontaminated by clouds, instead of AlRS temperature soundings, was only slightly better than that resulting from assimilation of only stratospheric AlRS temperatures. This reduction in forecast skill is most likely the result of significant loss of tropospheric information when only AIRS radiances unaffected by clouds are used in the data assimilation process.

Susskind, Joel↗

User's Guide for ERB 7 Matrix. Volume 1: Experiment Description and Quality Control Report for Year 1

The Nimbus 7 ERB MATRIX Tape is a computer program in which radiances and irradiances are converted into fluxes which are used to compute the basic scientific output parameters, emitted flux, albedo, and net radiation. They are spatially averaged and presented as time averages over one-day, six-day, and monthly periods. MATRIX data for the period November 16, 1978 through October 31, 1979 are presented. Described are the Earth Radiation Budget experiment, the Science Quality Control Report, Items checked by the MATRIX Science Quality Control Program, and Science Quality Control Data Analysis Report. Additional material from the detailed scientific quality control of the tapes which may be very useful to a user of the MATRIX tapes is included. Known errors and data problems and some suggestions on how to use the data for further climatologic and atmospheric physics studies are also discussed.

Tighe, R. J.↗