Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mitochondrial quality control pathways: PINK1 acts as a gatekeeper

Highlights: • A well-defined network of mitochondria quality control processes are required to maintain a functional and healthy pool of mitochondria within the cells. • Activation of proteins involved in mitochondrial quality control pathways, such as Parkin, Mfn2, DRP1 and Miro; is regulated by the mitochondrial kinase PINK1. • It is proposed that PINK1 acts as a gatekeeper of mitochondrial quality control mechanisms. Mitochondria have a pivotal role in the maintenance of cell homeostasis and survival. Mitochondria are involved in processes such as ATP production, reactive oxygen species production, apoptosis induction, calcium homeostasis and protein degradation. Thus, mechanisms that regulate the intrinsic quality of mitochondria have a crucial role in dictating overall cell fate. The importance of these well-regulated mechanisms is highlighted in disease scenarios such as neurodegeneration, cancer and neuromuscular atrophy. How mitochondria senses and regulates their intrinsic quality control, and consequently cell survival, is still not fully understood. In this review, we discuss the pathways that are at present considered as state-of-the-art for mitochondria quality control regulation, and highlight a mitochondrial protein–PINK1–that has revealed to act as a mitochondrial gatekeeper able to sense the presence of healthy or damaged mitochondria.

60 APPLIED LIFE SCIENCES↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems

Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.

60 APPLIED LIFE SCIENCES↗

SU-E-T-103: Development and Implementation of Web Based Quality Control Software

Purpose: Historically many radiation medicine programs have maintained their Quality Control (QC) test results in paper records or Microsoft Excel worksheets. Both these approaches represent significant logistical challenges, and are not predisposed to data review and approval. It has been our group's aim to develop and implement web based software designed not just to record and store QC data in a centralized database, but to provide scheduling and data review tools to help manage a radiation therapy clinics Equipment Quality control program. Methods: The software was written in the Python programming language using the Django web framework. In order to promote collaboration and validation from other centres the code was made open source and is freely available to the public via an online source code repository. The code was written to provide a common user interface for data entry, formalize the review and approval process, and offer automated data trending and process control analysis of test results. Results: As of February 2014, our installation of QAtrack+ has 180 tests defined in its database and has collected ∼22 000 test results, all of which have been reviewed and approved by a physicist via QATrack+'s review tools. These results include records for quality control of Elekta accelerators, CT simulators, our brachytherapy programme, TomoTherapy and Cyberknife units. Currently at least 5 other centres are known to be running QAtrack+ clinically, forming the start of an international user community. Conclusion: QAtrack+ has proven to be an effective tool for collecting radiation therapy QC data, allowing for rapid review and trending of data for a wide variety of treatment units. As free and open source software, all source code, documentation and a bug tracker are available to the public at https://bitbucket.org/tohccmedphys/qatrackplus/.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quality control and crop characterization framework for multi-temporal UAV LiDAR data over mechanized agricultural fields

Recent developments in remote sensing are enabling automatic, high resolution, and non-destructive survey of agriculture fields, providing the key basis for advancing plant breeding. Among the used remote sensing modalities, LiDAR has attracted wide attention for its ability to directly provide accurate 3D information. Despite the increasing utilization of LiDAR technology in phenotyping, there is still a lack of effective quality control strategies, in particular, quality control of LiDAR data collected on a multi-temporal basis. This study proposes a targetless framework for multi-temporal LiDAR data quality control and crop characterization in mechanized agricultural fields. Features extracted from the fields – terrain patches and row/alley locations – are utilized for evaluating the vertical and planimetric relative accuracy of the point clouds. Row/alley locations in the field are automatically identified from the point clouds based on the assumption that higher point density and/or higher elevation correspond to plant locations. The performance of the proposed quality control strategies is evaluated using multi-temporal datasets collected in agricultural fields of different sizes, orientation, crops, and growth stages. The result shows that the net vertical and planimetric discrepancies between multi-temporal point clouds are ±3 cm and ±8 cm, respectively. While the former reflects the actual accuracy of the point clouds, the latter is a combined effect of the LiDAR point cloud accuracy, rasterization artifacts, crop type, growth pattern, and wind condition during data acquisition. In terms of row and alley detection, the result shows that the proposed strategy achieves high performance and can deal with different planting orientation, crop types, growth stages, canopy cover, and planting density. In conclusion, this study presents a quality control framework for multi-temporal LiDAR data. Finally, the row and alley detection leads to automated extraction of plots, and hence facilitates the use of remotely sensed data for automated phenotyping.

54 ENVIRONMENTAL SCIENCES↗

Spectroscopic Investigation of Catalyst Inks and Thin Films Toward the Development of Ionomer Quality Control

As the production of polymer electrolyte fuel cells expands, novel quality control methods must be invented or adapted in order to support expected rates of production. Ensuring the quality of deposited catalyst layers is an essential step in the fuel cell manufacturing process, as the efficiency of a fuel cell is reliant on the catalyst layer being uniform at both the target platinum loading and the target ionomer content. Implementing a quality control method that is sensitive to these aspects is imperative, as wasting precious metals and other catalyst materials is expensive, and represents a potential barrier to entry into the field for manufacturers experimenting with novel deposition processes. In this work, we analyzed catalyst inks to determine if their ionomer content could be quantized spectroscopically. Attenuated total reflection (ATR) Fourier transform infrared spectroscopic technique was investigated producing a signal proportional to the ionomer content. ATR spectroscopy was able to quantitatively differentiate samples in which the ionomer to carbon mass ratio (I/C) varied between 0.9 and 3.0. The I/C ratio was correlated to the measured ATR signal near the CF 2 vibrational bands located between 1100 cm −1 and 1400 cm −1 . The experimental results obtained constitute a step toward the development of novel quality control methodologies for catalyst inks utilized by the fuel cell industry.

30 DIRECT ENERGY CONVERSION↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-9A-08: Knowledge-Based Quality Control of Clinical Stereotactic Radiosurgery Treatment Plans

Purpose: To develop a quality control tool to reduce stereotactic radiosurgery (SRS) planning variability using models that predict achievable plan quality metrics (QMs) based on individual patient anatomy. Methods: Using a knowledge-based methodology that quantitatively correlates anatomical geometric features to resultant organ-at-risk (OAR) dosimetry, we developed models for predicting achievable OAR dose-volume histograms (DVHs) by training with a cohort of previously treated SRS patients. The DVH-based QMs used in this work are the gradient measure, GM=(3/4pi)^1/3*[V50%^1/3−V100%^1/3], and V10Gy of normal brain. As GM quantifies the total rate of dose fall-off around the planning target volume (PTV), all voxels inside the patient's body contour were treated as OAR for DVH prediction. 35 previously treated SRS plans from our institution were collected; all were planned with non-coplanar volumetric-modulated arc therapy to prescription doses of 12–25 Gy. Of the 35-patient cohort, 15 were used for model training and 20 for model validation. Accuracies of the predictions were quantified by the mean and the standard deviation of the difference between clinical and predicted QMs, δQM=QM-clin−QM-pred. Results: Best agreement between predicted and clinical QMs was obtained when models were built separately for V-PTV<2.5cc and V-PTV>2.5cc. Eight patients trained the V-PTV<2.5cc model and seven patients trained the V-PTV>2.5cc models, respectively. The mean and the standard deviation of δGM were 0.3±0.4mm for the training sets and −0.1±0.6mm for the validation sets, demonstrating highly accurate GM predictions. V10Gy predictions were also highly accurate, with δV10Gy=0.8±0.7cc for the training sets and δV10Gy=0.7±1.4cc for the validation sets. Conclusion: The accuracy of the models in predicting two key SRS quality metrics highlights the potential of this technique for quality control for SRS treatments. Future investigations will seek to determine whether QM variations are due to residual model inaccuracies or true plan quality variations in the clinical sample. Support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-15: The Roucoulette: A Set of Quality Control Tests for Dynamic Trajectory (4Pi) Treatment Delivery Techniques

Purpose: To present and validate a set of quality control tests for trajectory treatment delivery using synchronized dynamic couch (translation and rotation), MLC and collimator motion. Methods: The quality control tests are based on the Picket fence test, which consist of 5 narrow band 2mm width spaced at 2.5cm intervals, and adds progressively synchronized dynamic motions. The tests were exposed on GafChromic EBT3 films. The first test is a regular (no motion and MLC static while beam is on) Picket Fence test used as baseline. The second test includes simultaneous collimator and couch rotation, each stripe corresponding to a different rotation speed. Errors in these tests were introduced (0.5 degree and 1 degree error in rotation synchronization) to assess the error sensitivity of this test. The second test is similar to the regular Picket Fence but now including dynamic MLC motion and couch translation (including acceleration during delivery) while the beam is on. Finally in the third test, which is a combination of the first and second test, the Picket Fence pattern is delivered using synchronized collimator and couch rotation and synchronized dynamic MLC and couch translation including acceleration. Films were analyzed with FilmQA Pro. Results: The distance between the peaks in the dose profile where measured (18.5cm away from the isocentre in the inplane direction where non synchronized rotation would have the largest effect) and compared to the regular Picket Fence tests. For well synchronized motions distances between peaks where between 24.9–25.4 mm identical to the regular Picket Fence test. This range increased to 24.4–26.4mm and 23.4–26.4mm for 0.5 degree and 1 degree error respectively. The amplitude also decreased up to 15% when errors are introduced. Conclusion: We demonstrated that the Roucoulette tests can be used as a quality control tests for trajectory treatment delivery using synchronized dynamic motion.

60 APPLIED LIFE SCIENCES↗

Systems and methods for quality control of a periodic structure

Quality control of a periodic structure is performed using the damping rate of acoustic waves generated in the periodic structure. In this technique, an excitation light beam illuminates the first layer in the periodic structure to excite an acoustic wave. Possible irregularities in the periodic structure can scatter the acoustic wave, thereby increasing the damping rate of the acoustic wave. A sequence of probe light beams illuminates the periodic structure to measure the acoustic wave as a function of time to generated a temporal signal representing the damping rate of the acoustic signal. The acquired damping rate is employed to evaluate the quality of the periodic structure.

Maznev, Alexei↗

Experience-Based Quality Control of Clinical Intensity-Modulated Radiotherapy Planning

Purpose: To incorporate a quality control tool, according to previous planning experience and patient-specific anatomic information, into the intensity-modulated radiotherapy (IMRT) plan generation process and to determine whether the tool improved treatment plan quality. Methods and Materials: A retrospective study of 42 IMRT plans demonstrated a correlation between the fraction of organs at risk (OARs) overlapping the planning target volume and the mean dose. This yielded a model, predicted dose = prescription dose (0.2 + 0.8 [1 - exp(-3 overlapping planning target volume/volume of OAR)]), that predicted the achievable mean doses according to the planning target volume overlap/volume of OAR and the prescription dose. The model was incorporated into the planning process by way of a user-executable script that reported the predicted dose for any OAR. The script was introduced to clinicians engaged in IMRT planning and deployed thereafter. The script's effect was evaluated by tracking {delta} = (mean dose-predicted dose)/predicted dose, the fraction by which the mean dose exceeded the model. Results: All OARs under investigation (rectum and bladder in prostate cancer; parotid glands, esophagus, and larynx in head-and-neck cancer) exhibited both smaller {delta} and reduced variability after script implementation. These effects were substantial for the parotid glands, for which the previous {delta} = 0.28 {+-} 0.24 was reduced to {delta} = 0.13 {+-} 0.10. The clinical relevance was most evident in the subset of cases in which the parotid glands were potentially salvageable (predicted dose <30 Gy). Before script implementation, an average of 30.1 Gy was delivered to the salvageable cases, with an average predicted dose of 20.3 Gy. After implementation, an average of 18.7 Gy was delivered to salvageable cases, with an average predicted dose of 17.2 Gy. In the prostate cases, the rectum model excess was reduced from {delta} = 0.28 {+-} 0.20 to {delta} = 0.07 {+-} 0.15. On surveying dosimetrists at the end of the study, most reported that the script both improved their IMRT planning (8 of 10) and increased their efficiency (6 of 10). Conclusions: This tool proved successful in increasing normal tissue sparing and reducing interclinician variability, providing effective quality control of the IMRT plan development process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NREL Job Task Analysis: Quality Control Inspector

A summary of job task analyses for the position of quality control inspector when evaluating weatherization work that has been done on a residence.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Principles of Product Quality Control of German Radioactive Waste Forms from the Reprocessing of Spent Fuel: Vitrification, Compaction and Numerical Simulation - 12529

The German product quality control is inter alia responsible for control of two radioactive waste forms of heat generating waste: a) homogeneous vitrified HLW and b) heterogeneous compacted hulls, end-pieces and technological metallic waste. In either case, significantly different metrology is employed at the site of the conditioning plant for the obligatory nuclide inventory declaration. To facilitate an independent evaluation and checking of the accompanying documentation numerical simulations are carried out. The physical and chemical properties of radioactive waste residues are used to assess the data consistency and uncertainty margins, as well as to predict the long-term behavior of the radioactive waste. This is relevant for repository acceptance and safety considerations. Our new numerical approach follows a bottom-up simulation starting from the burn-up behavior of the fuel elements in the reactor core. The output of these burn-up calculations is then coupled with a program that simulates the material separation in the subsequent dissolution and extraction processes normalized to the mass balance. Follow-up simulations of the separated reprocessing lines of a) the vitrification of highly-active liquid and b) the compaction of residual intermediate-active metallic hulls remaining after fuel pellets dissolution, end-pieces and technological waste, allows calculating expectation values for the various repository relevant properties of either waste stream. The principles of the German product quality control of radioactive waste residues from the spent fuel reprocessing have been introduced and explained. Namely, heat generating homogeneous vitrified HLW and heterogeneous compacted metallic MLW have been discussed. The advantages of a complementary numerical property simulation have been made clear and examples of benefits are presented. We have compiled a new program suite to calculate the physical and radio-chemical properties of common nuclear waste residues. The immediate benefit is the independent assessment of radio-active inventory declarations and much facilitated product quality control of waste residues that need to be returned to Germany and submitted to a German HLW-repository requirements. Wherever possible, internationally accepted standard programs are used and embedded. The innovative coupling of burn-up calculations (SCALE) with neutron and gamma transport codes (MCPN-X) allows an application in the world of virtual waste properties. If-then-else scenarios of hypothetical waste material compositions and distributions provide valuable information of long term nuclide property propagation under repository conditions over a very long time span. Benchmarking the program with real residue data demonstrates the power and remarkable accuracy of this numerical approach, boosting the reliability of the confidence aforementioned numerous applications, namely the proof tool set for on-the-spot production quality checking and data evaluation and independent verification. Moreover, using the numerical bottom-up approach helps to avoid the accumulation of fake activities that may gradually build up in a repository from the so-called conservative or penalizing nuclide inventory declarations. The radioactive waste properties and the hydrolytic and chemical stability can be predicted. The interaction with invasive chemicals can be assessed and propagation scenarios can be developed from reliable and sound data and HLW properties. Hence, the appropriate design of a future HLW repository can be based upon predictable and quality assured waste characteristics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quality Control by Artificial Vision

Computational technology has fundamentally changed many aspects of our lives. One clear evidence is the development of artificial-vision systems, which have effectively automated many manual tasks ranging from quality inspection to quantitative assessment. In many cases, these machine-vision systems are even preferred over manual ones due to their repeatability and high precision. Such advantages come from significant research efforts in advancing sensor technology, illumination, computational hardware, and image-processing algorithms. Similar to the Special Section on Quality Control by Artificial Vision published two years ago in Volume 17, Issue 3 of the Journal of Electronic Imaging, the present one invited papers relevant to fundamental technology improvements to foster quality control by artificial vision, and fine-tuned the technology for specific applications. We aim to balance both theoretical and applied work pertinent to this special section theme. Consequently, we have seven high-quality papers resulting from the stringent peer-reviewing process in place at the Journal of Electronic Imaging. Some of the papers contain extended treatment of the authors work presented at the SPIE Image Processing: Machine Vision Applications conference and the International Conference on Quality Control by Artificial Vision. On the broad application side, Liu et al. propose an unsupervised texture image segmentation scheme. Using a multilayer data condensation spectral clustering algorithm together with wavelet transform, they demonstrate the effectiveness of their approach on both texture and synthetic aperture radar images. A problem related to image segmentation is image extraction. For this, O'Leary et al. investigate the theory of polynomial moments and show how these moments can be compared to classical filters. They also show how to use the discrete polynomial-basis functions for the extraction of 3-D embossed digits, demonstrating superiority over Fourier-basis functions for this task. Image registration is another important task for machine vision. Bingham and Arrowood investigate the implementation and results in applying Fourier phase matching for projection registration, with a particular focus on nondestructive testing using computed tomography. Readers interested in enriching their arsenal of image-processing algorithms for machine-vision tasks should find these papers enriching. Meanwhile, we have four papers dealing with more specific machine-vision tasks. The first one, Yahiaoui et al., is quantitative in nature, using machine vision for real-time passenger counting. Occulsion is a common problem in counting objects and people, and they circumvent this issue with a dense stereovision system, achieving 97 to 99% accuracy in their tests. On the other hand, the second paper by Oswald-Tranta et al. focuses on thermographic crack detection. An infrared camera is used to detect inhomogeneities, which may indicate surface cracks. They describe the various steps in developing fully automated testing equipment aimed at a high throughput. Another paper describing an inspection system is Molleda et al., which handles flatness inspection of rolled products. They employ optical-laser triangulation and 3-D surface reconstruction for this task, showing how these can be achieved in real time. Last but not least, Presles et al. propose a way to monitor the particle-size distribution of batch crystallization processes. This is achieved through a new in situ imaging probe and image-analysis methods. While it is unlikely any reader may be working on these four specific problems at the same time, we are confident that readers will find these papers inspiring and potentially helpful to their own machine-vision system developments.

99 GENERAL AND MISCELLANEOUS↗

Apparatus for implementing non-destructive quality control of substrates and printed biological microarrays

Apparatus implements non-destructive quality control of substrates and printed biological microarrays. A method and apparatus are provided for implementing quality control of gel-based microarrays prepared by dispensing a gel-forming composition on a solid substrate. The method utilizes the difference between the wettability properties of a supporting substrate and a gel, where the gel is hydrophilic. Condensation of vapor of a chemically inert water-soluble liquid, such as water or glycerol, on the surface of a substrate under inspection creates a layer of tiny droplets that affect both transmission and scattering of light on the surface. A pattern of condensation, characterized by spatial distribution, average size of the droplets and spacing between the droplets, reflects variation in wetting properties of the substrate. The pattern of condensation circumscribes printed microarray features to be non-destructively imaged and analyzed.

59 BASIC BIOLOGICAL SCIENCES↗

The Marine and Hydrokinetic ToolKit (MHKiT) for Data Quality Control and Analysis [Slides]

The ability to collect, ingest, condition, reduce, quality control, process, visualize, and store data in a standardized way is critical at all stages of Marine Energy (ME) research and technology/project development. MHKiT is an open-source, standardized suite of ME data processing functions that provides the ability to ingest, condition, reduce, quality control, process, visualize and store ME data. MHKiT is developed in both Python and Matlab.

16 TIDAL AND WAVE POWER↗

A review of functions, attributes, properties and measurements for the quality control of proton exchange membrane fuel cell components

Quality control (QC) is an essential part of fuel cell technology industrialization, providing means to reduce cost of components, enhancing the reliability of the final product, and offering specification guidance for new entrants in the supply chain. The membrane electrode assembly (MEA), including membrane, catalyst layer (CL), and gas diffusion layer (GDL), as well as bipolar plate (BP), are key components of a proton exchange membrane (PEM) fuel cell, and the attributes of each component strongly correlate with the cell performance and longevity. To ensure the quality of the fuel cell, it is of great importance to characterize the properties with respect to the standardization of component/sub-component specifications. In collaboration with the fuel cell industry, this work aims at establishing compendiums of attributes, or so-called books of attributes, of key fuel cell components for the QC of PEM fuel cells through reviewing, identifying, categorizing, and prioritizing the main attributes/properties that determine their functionalities. The books of attributes for the major PEM fuel cell components include catalyst coated membrane (CCM) as a sub-assembly, GDL, and BP. To address the full spectrum of fuel cell components, gaskets and sub-gaskets are also included.

25 ENERGY STORAGE↗