Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantum interference devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ultra low noise YBa{sub 2}Cu{sub 3}O{sub 7−δ} nano superconducting quantum interference devices implementing nanowires

We present results on ultra low noise YBa{sub 2}Cu{sub 3}O{sub 7–δ} (YBCO) nano Superconducting QUantum Interference Devices (nanoSQUIDs). To realize such devices, we implemented high quality YBCO nanowires, working as weak links between two electrodes. We observe critical current modulation as a function of an externally applied magnetic field in the full temperature range below the transition temperature T{sub C}. The white flux noise below 1μΦ{sub 0}/√(Hz) at T=8 K makes our nanoSQUIDs very attractive for the detection of small spin systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superconducting quantum interference devices based set-up for probing current noise and correlations in three-terminal devices

We have implemented a new experimental set-up for precise measurements of current fluctuations in three-terminal devices. The system operates at very low temperatures (30 mK) and is equipped with three superconducting quantum interference devices (SQUIDs) as low noise current amplifiers. A SQUID input coil is connected to each terminal of a sample allowing the acquisition of time-dependent current everywhere in the circuit. From these traces, we can measure the current mean value, the noise, and cross-correlations between different branches of a device. In this paper, we present calibration results of noise and cross-correlations obtained using low impedance macroscopic resistors. From these results, we can extract the noise level of the set-up and show that there are no intrinsic correlations due to the measurement scheme. We also studied noise and correlations as a function of a dc current and estimated the electronic temperature of various macroscopic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical transmission modules for multi-channel superconducting quantum interference device readouts

We developed an optical transmission module consisting of 16-channel analog-to-digital converter (ADC), digital-noise filter, and one-line serial transmitter, which transferred Superconducting Quantum Interference Device (SQUID) readout data to a computer by a single optical cable. A 16-channel ADC sent out SQUID readouts data with 32-bit serial data of 8-bit channel and 24-bit voltage data at a sample rate of 1.5 kSample/s. A digital-noise filter suppressed digital noises generated by digital clocks to obtain SQUID modulation as large as possible. One-line serial transmitter reformed 32-bit serial data to the modulated data that contained data and clock, and sent them through a single optical cable. When the optical transmission modules were applied to 152-channel SQUID magnetoencephalography system, this system maintained a field noise level of 3 fT/√Hz @ 100 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sketched Nanoscale KTaO 3 -Based Superconducting Quantum Interference Device

The discovery of two-dimensional superconductivity in LaAlO 3 /KTaO 3 (111) and (110) interfaces has raised significant interest in this system. In this paper, we report the first successful fabrication of a direct current superconducting quantum interference device (dc-SQUID) in the KTO system. The key device elements, superconducting weak links, are created by conductive atomic force microscope lithography, which can reversibly control the conductivity at the LAO/KTO (110) interface with nanoscale resolution. The periodic modulation of the SQUID critical current 𝐼 c ⁡(𝐵) with magnetic field corresponds well with our theoretical modeling, which reveals a large kinetic inductance of the superconducting two-dimensional electron gas in KTO. The kinetic inductance of the SQUID is tunable by electrical gating from the back, due to the large dielectric constant of KTO. The demonstration of weak links and SQUIDs in KTO broadens the scope for exploring the underlying physics of KTO superconductivity, including the role of spin-orbit coupling, pairing symmetry, and inhomogeneity. It also promotes KTO as a versatile platform for a growing family of quantum devices, which could be applicable in the realm of quantum computing and information.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Joint measurement of current-phase relations and transport properties of hybrid junctions using a three junctions superconducting quantum interference device

We propose a scheme to measure both the current-phase relation and differential conductance dI/dV of a superconducting junction, in the normal and the superconducting states. This is done using a dc Superconducting Quantum Interference Device with two Josephson junctions in parallel with the device under investigation and three contacts. As a demonstration, we measure the current-phase relation and dI/dV of a small Josephson junction and a carbon nanotube junction. In this latter case, in a regime where the nanotube is well conducting, we show that the non-sinusoidal current phase relation we find is consistent with the theory for a weak link, using the transmission extracted from the differential conductance in the normal state. This method holds great promise for future investigations of the current-phase relation of more exotic junctions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A superconducting quantum interference device based read-out of a subattonewton force sensor operating at millikelvin temperatures

We present a scheme to measure the displacement of a nanomechanical resonator at cryogenic temperature. The technique is based on the use of a superconducting quantum interference device to detect the magnetic flux change induced by a magnetized particle attached on the end of the resonator. Unlike conventional interferometric techniques, our detection scheme does not involve direct power dissipation in the resonator, and therefore, is particularly suitable for ultralow temperature applications. We demonstrate its potential by cooling an ultrasoft silicon cantilever to a noise temperature of 25 mK, corresponding to a subattonewton thermal force noise of 0.5 aN/{radical}(Hz).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Alternating current magnetic susceptibility of a molecular magnet submonolayer directly patterned onto a micro superconducting quantum interference device

We report the controlled integration, via dip pen nanolithography, of monolayer dots of ferritin-based CoO nanoparticles (12 μ{sub B}) into the most sensitive areas of a microSQUID sensor. The nearly optimum flux coupling between these nanomagnets and the microSQUID improves the achievable sensitivity by a factor 10{sup 2}, enabling us to measure the linear susceptibility of the molecular array down to very low temperatures (13 mK). This method opens the possibility of applying ac susceptibility experiments to characterize two-dimensional arrays of single molecule magnets within a wide range of temperatures and frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tracking geomagnetic fluctuations to picotesla accuracy using two superconducting quantum interference device vector magnetometers

SQUIDs can be used to monitor the three vector components of the geomagnetic field to a high precision at very low frequencies, yet as they are susceptible to external interference, the accuracy to which they can track changes in the dc field over long periods has been unclear. We have carried out simultaneous measurements of the geomagnetic field recorded using two independent 3-axis SQUID magnetometers at the Laboratoire Souterrain a Bas Bruit (LSBB). We demonstrate a technique to take the difference between a linear transform of the three signals from one magnetometer, and a reference signal from the other, in order to account for any difference in alignment and calibration, and track local signals at a sub-nT level. We confirmed that both systems tracked the same signal with an RMS difference as low as 56pT over a period of 72 h. To our knowledge this is the first such demonstration of the long term accuracy of SQUID magnetometers for monitoring geomagnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical cell for in situ electrodeposition of magnetic thin films in a superconducting quantum interference device magnetometer

An electrochemical cell is designed and applied for in situ electrodeposition of magnetic thin films in a commercial SQUID magnetometer system. The cell is constructed in such a way that any parasitic contribution of the cell and of the substrate for electrodeposition to the magnetic moment of the deposited film is reduced to a minimum. A remanent minor contribution is readily taken into account by a proper analysis of the detected signal. Thus, a precise determination of the absolute magnetic moment of the electrodeposited magnetic film during its growth and dissolution is achieved. The feasibility of the cell design is demonstrated by performing Co electrodeposition using cyclic voltammetry. For an average Co film thickness of (35.6 ± 3.0) atomic layers, a magnetic moment per Co atom of (1.75 ± 0.11) μ{sub B} was estimated, in good agreement with the literature bulk value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting quantum-interference devices

Published document discusses devices which are based on weak-link Josephson elements that join superconductors. Links can take numerous forms, and circuitry utilizing links can perform many varied functions with unprecedented sensitivity. Theoretical review of Josephson's junctions include tunneling junctions, point contact devices, microbridges, and proximity-effect devices.

Peters, P. N.↗

Enhancements to a Superconducting Quantum Interference Device (SQUID) Multiplexer Readout and Control System

Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.

Forgione, J.↗