Search NASA⌕ Search

SEARCH · Search NASA

Results for “RAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of the NSUF Reactor Activation and Damage (RAD) Calculator damage component

The Nuclear Science User Facilities (NSUF) provide researchers access to nuclear research facilities and expertise all over the United States and at the Belgian Center for Nuclear Research (SCK/CEN). One special capability of the NSUF is providing access to nuclear research and test reactors often used for conducting material testing experiments. These services are provided at no cost to the researcher through a competitive, peer-reviewed process. With so many proposals being submitted simultaneously, an NSUF information management resource called the Combined Materials Experiment Toolkit (CoMET) was implemented to speed up the review process and give users access to the information and tools necessary for designing meaningful experiments and writing the best proposals possible. One of CoMET’s tools is the Reactor Activation and Damage (RAD) Calculator. For those with little or no background in it, neutron irradiation in research and test reactors can be a challenging subject to include in a proposal. That is why the RAD Calculator was created to assist users with providing estimates of irradiation and post-irradiation conditions, enabling them to select the best neutron irradiation and post-irradiation examination facilities for reaching their experiment goals. The RAD Calculator is a general scoping tool that estimates radiation damage in terms of DPA, in addition to the resulting radioactivity of the material post-irradiation. This report evaluates the neutron damage component of the RAD Calculator. The evaluation of the activation component of the calculator is covered in report INL/EXT-20-58080.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cosmic Radiation Dose Measurements from the RaD-X Flight Campaign

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission obtained measurements for improving the understanding of cosmic radiation transport in the atmosphere and human exposure to this ionizing radiation field in the aircraft environment. The value of dosimetric measurements from the balloon platform is that they can be used to characterize cosmic ray primaries, the ultimate source of aviation radiation exposure. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. The RaD-X balloon was successfully launched from Fort Sumner, New Mexico (34.5 degrees North, 104.2 degrees West) on 25 September 2015. Over 18 hours of flight data were obtained from each of the four different science instruments at altitudes above 20 kilometers. The RaD-X balloon flight was supplemented by contemporaneous aircraft measurements. Flight-averaged dosimetric quantities are reported at seven altitudes to provide benchmark measurements for improving aviation radiation models. The altitude range of the flight data extends from commercial aircraft altitudes to above the Pfotzer maximum where the dosimetric quantities are influenced by cosmic ray primaries. The RaD-X balloon flight observed an absence of the Pfotzer maximum in the measurements of dose equivalent rate.

Mertens, Christopher J.↗

NAIRAS Version 3 Atmospheric Ionizing Radiation Validation: Comparisons to RaD-X Measurements

The Nowcast of Aerospace Ionizing RAdiation System (NAIRAS) model predicts dosimetric and radiative flux quantities for assessing human radiation exposure levels and radiation effects on flight electronic systems from the surface of the Earth to deep space. NAIRAS version 3 includes many updates and improvements to the model. In this paper, NAIRAS version 3 dosimetric quantities are compared to observations of the atmospheric radiation environment taken during the Radiation Dosimetry Experiment (RaD-X) flight campaign. The RaD-X campaign consisted of a high-altitude balloon flight, with altitudes up to 40 km, and four coordinated aircraft flights covering an altitude range from 6-20 km. The RaD-X measurement data from the different flight platforms were acquired in September 2015 and at nearly the same vertical cutoff rigidity (3-4 GV). High quality, flight-averaged measurement data were provided at seven altitudes, which correspond to regions of fundamentally different radiation transport and collisional interaction physics. The NAIRAS model agrees with the RaD-X measurements to within 30% over the entire altitude domain of the flight campaign (0-40 km), which is within the measurement uncertainty.

Christopher J Mertens↗

LI-RADS for CT diagnosis of hepatocellular carcinoma: performance of major and ancillary features

Purpose: To evaluate the diagnostic performance of Liver Imaging Reporting and Data System (LI-RADS) v2017 major features, the impact of ancillary features, and categories on contrast-enhanced computed tomography (CECT) for the diagnosis of hepatocellular carcinoma (HCC). Materials and methods: This retrospective study included 59 patients (104 observations including 72 HCCs) with clinical suspicion of HCC undergoing CECT between 2013 and 2016. Two radiologists independently assessed major and ancillary imaging features for each liver observation and assigned a LI-RADS category based on major features only and in combination with ancillary features. The composite reference standard included pathology or imaging. Per-lesion estimates of diagnostic performance of major features, ancillary features, and LI-RADS categories were assessed by generalized estimating equation models. Results: Major features (arterial phase hyperenhancement, washout, capsule, and threshold growth) respectively had a sensitivity of 86.1%, 81.6%, 20.7%, and 26.1% and specificity of 39.3%, 67.9%, 89.9%, and 85.0% for HCC. Ancillary features (ultrasound visibility as discrete nodule, subthreshold growth, and fat in mass more than adjacent liver) respectively had a sensitivity of 42.6%, 50.8%, and 15.1% and a specificity of 79.2%, 66.9%, and 96.4% for HCC. Ancillary features modified the final category in 4 of 104 observations. For HCC diagnosis, categories LR-3, LR-4, LR-5, and LR-TIV (tumor in vein) had a sensitivity of 5.3%, 29.0%, 53.7%, and 10.7%; and a specificity of 49.1%, 84.4%, 97.3%, and 96.4%, respectively. Conclusion: On CT, LR-5 category has near-perfect specificity for the diagnosis of HCC and ancillary features modifies the final category in few observations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic imaging of hepatocellular carcinoma at community hospitals and their tertiary referral center in the era of LI-RADS: a quality assessment study

Purpose: To assess guideline compliance and quality of hepatocellular carcinoma, (HCC) diagnostic imaging within community hospitals (CH) and their Tertiary referral center (TRC) in a moderately high incidence region. Methods: Initial diagnostic workup CT/MRI scans of 251 patients (122 CH, 112 TRC, 17 Non-TRC academic) with HCC over a 15-month period were assessed for Liver reporting and Data System (LI-RADS) guideline compliance. 269 scans (182 CT, 87 MRI) were qualitatively evaluated by 2 independent blinded radiologists for arterial timing, overall image quality, noise and sharpness, with quantification of interobserver variability. The contrast enhancement ratio (CER) for the largest HCC on each scan was calculated using pre- and post-contrast images. Results: 103/104 (99%) of TRC and 44/78 (56%) of CH CTs adhered to LI–RADS imaging guidelines (P < 0.0001). Lack of delayed phase accounted for 32/34 (94%) of noncompliant CH CTs. Regarding MRI, 19/19 (100%) of TRC and 60/68 (88%) of CH scans were adherent (P = 0.12). For both modalities, overall image quality, noise and sharpness were rated significantly higher for TRC than CH. There was moderate interobserver agreement with intraclass correlation coefficient of 0.73, 0.70 and 0.63, respectively. Arterial-phase timing was rated adequate for CT in 75/104 TRC (72%) and 10/68 (14%) CH scans (P < 0.0001) and for MRI in 8/19 (42%) TRC and 23/68 (33%) CH scans (P = 0.17). The CER was significantly higher for TRC versus CH (2.9 vs. 1.9, P < 0.001) and MRI (0.9 vs. 0.7, P = 0.03). Conclusions: Community hospital HCC diagnostic scans significantly lag in critical quality parameters of tumor enhancement, arterial phase timing, perceived image quality, and LI-RADS CT technique compliance compared to a TRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MODELING THE VARIATIONS OF DOSE RATE MEASURED BY RAD DURING THE FIRST MSL MARTIAN YEAR: 2012–2014

The Radiation Assessment Detector (RAD), on board Mars Science Laboratory’s (MSL) rover Curiosity, measures the energy spectra of both energetic charged and neutral particles along with the radiation dose rate at the surface of Mars. With these first-ever measurements on the Martian surface, RAD observed several effects influencing the galactic cosmic-ray (GCR) induced surface radiation dose concurrently: (a) short-term diurnal variations of the Martian atmospheric pressure caused by daily thermal tides, (b) long-term seasonal pressure changes in the Martian atmosphere, and (c) the modulation of the primary GCR flux by the heliospheric magnetic field, which correlates with long-term solar activity and the rotation of the Sun. The RAD surface dose measurements, along with the surface pressure data and the solar modulation factor, are analyzed and fitted to empirical models that quantitatively demonstrate how the long-term influences ((b) and (c)) are related to the measured dose rates. Correspondingly, we can estimate dose rate and dose equivalents under different solar modulations and different atmospheric conditions, thus allowing empirical predictions of the Martian surface radiation environment.

79 ASTRONOMY AND ASTROPHYSICS↗

TagDigger: user-friendly extraction of read counts from GBS and RAD-seq data

In genotyping-by-sequencing (GBS) and restriction site-associated DNA sequencing (RAD-seq), read depth is important for assessing the quality of genotype calls and estimating allele dosage in polyploids. However, existing pipelines for GBS and RAD-seq do not provide read counts in formats that are both accurate and easy to access. Additionally, although existing pipelines allow previously-mined SNPs to be genotyped on new samples, they do not allow the user to manually specify a subset of loci to examine. Pipelines that do not use a reference genome assign arbitrary names to SNPs, making meta-analysis across projects difficult. We created the software TagDigger, which includes three programs for analyzing GBS and RAD-seq data. The first script, tagdigger_interactive.py, rapidly extracts read counts and genotypes from FASTQ files using user supplied sets of barcodes and tags. Input and output is in CSV format so that it can be opened by spreadsheet software. Tag sequences can also be imported from the Stacks, TASSEL-GBSv2, TASSEL-UNEAK, or pyRAD pipelines, and a separate file can be imported listing the names of markers to retain. A second script, tag_manager.py, consolidates marker names and sequences across multiple projects. A third script, barcode_splitter.py, assists with preparing FASTQ data for deposit in a public archive by splitting FASTQ files by barcode and generating MD5 checksums for the resulting files. TagDigger is open-source and freely available software written in Python 3. It uses a scalable, rapid search algorithm that can process over 100 million FASTQ reads per hour. TagDigger will run on a laptop with any operating system, does not consume hard drive space with intermediate files, and does not require programming skill to use.

59 BASIC BIOLOGICAL SCIENCES↗

Rad-Hard SBC: Radiation-Hardened Single-Board Computer

As global reliance on satellites and their services increases, scientists and engineers will continue to feel pressure to reduce costs, save power, and reduce size and weight. Los Alamos researchers have developed the Rad-Hard SBC to alleviate this pressure. The invention is a radiation- and mechanically-hardened single-board computer that is small, lightweight, and uses less power than any commercially available space-grade computer. Rad-Hard SBC provides an affordable option for long-lasting satellites beyond low-Earth orbits. The computer enables researchers, businesses, and consumers broader access to space assets for their unique needs. The invention builds on the Lab's more than fifty years of experience in designing, manufacturing, and deploying instruments for use on satellites and deep space missions. A R&D 100 Award has recognized the innovation and value of the Rad-Hard SBC.

42 ENGINEERING↗

The damage equivalence of electrons, protons, alphas and gamma rays in rad-hard MOS devices

This paper reports on a study of damage equivalence in rad-hard MOS devices with 100,000 rads (SiO2) capability. Damage sensitivities for electrons of 1, 2, 3, 5, and 7 MeV, protons of 1, 3, 7, 22, and 40 MeV, 3.4-MeV alphas, and Co-60 gammas were measured and compared. Results indicated that qualitatively the same charge recombination effects occurred in hard oxide devices for doses of 100,000 rads (SiO2) as in soft oxide parts for doses of 1 to 4 krads (SiO2). Consequently, damage equivalency or non-equivalency depended on radiation type and energy. However, recovery effects, both during and after irradiation, controlled relative damage sensitivity and its dependency on total dose, dose rate, supply bias, gate bias, radiation type, and energy. Correction factors can be derived from these data or from similar tests of other hard oxide type, so as to properly evaluate the combined effects of the total space environment.

Stassinopoulos, E. G.↗

Reconfigurable, Bi-Directional Flexfet Level Shifter for Low-Power, Rad-Hard Integration

Two prototype Reconfigurable, Bi-directional Flexfet Level Shifters (ReBiLS) have been developed, where one version is a stand-alone component designed to interface between external low voltage and high voltage, and the other version is an embedded integrated circuit (IC) for interface between internal low-voltage logic and external high-voltage components. Targeting stand-alone and embedded circuits separately allows optimization for these distinct applications. Both ReBiLS designs use the commercially available 180-nm Flex fet Independently Double-Gated (IDG) SOI CMOS (silicon on insulator, complementary metal oxide semiconductor) technology. Embedded ReBiLS circuits were integrated with a Reed-Solomon (RS) encoder using CMOS Ultra-Low-Power Radiation Tolerant (CULPRiT) double-gated digital logic circuits. The scope of the project includes: creation of a new high-voltage process, development of ReBiLS circuit designs, and adjustment of the designs to maximize performance through simulation, layout, and manufacture of prototypes. The primary technical objectives were to develop a high-voltage, thick oxide option for the 180-nm Flexfet process, and to develop a stand-alone ReBiLS IC with two 8-channel I/O busses, 1.8 2.5 I/O on the low-voltage pins, 5.0-V-tolerant input and 3.3-V output I/O on the high-voltage pins, and 100-MHz minimum operation with 10-pF external loads. Another objective was to develop an embedded, rad-hard ReBiLS I/O cell with 0.5-V low-voltage operation for interface with core logic, 5.0-V-tolerant input and 3.3-V output I/O pins, and 100-MHz minimum operation with 10- pF external loads. A third objective was to develop a 0.5- V Reed-Solomon Encoder with embedded ReBilS I/O: Transfer the existing CULPRiT RS encoder from a 0.35-micron bulk-CMOS process to the ASI 180-nm Flexfet, rad-hard SOI Process. 0.5-V low-voltage core logic. 5.0-V-tolerant input and 3.3-V output I/O pins. 100-MHz minimum operation with 10- pF external loads. The stand-alone ReBiLS chip will allow system designers to provide efficient bi-directional communication between components operating at different voltages. Embedding the ReBiLS cells into the proven Reed-Solomon encoder will demonstrate the ability to support new product development in a commercially viable, rad-hard, scalable 180-nm SOI CMOS process.

DeGregorio, Kelly↗

Capabilities, Calibration, and Impact of the ISS-RAD Fast Neutron Detector

In the current NASA crew radiation health risk assessment framework, estimates for the neutron contributions to crew radiation exposure largely rely on simulated data with sizeable uncertainties due to the lack of experimental measurements inside the ISS. Integrated in the ISS-RAD instrument, the ISS-RAD Fast Neutron Detector (FND) will deploy to the ISS on one of the next cargo supply missions. Together with the ISS-RAD Charged Particle Detector, the FND will perform, for the first time, routine and precise direct neutron measurements inside the ISS between 0.5 and 80 MeV. The measurements will close the NASA Medical Operations Requirement to monitor neutrons inside the ISS and impact crew radiation health risk assessments by reducing uncertainties on the neutron contribution to crew exposure, enabling more efficient mission planning. The presentation will focus on the FND detection mechanism, calibration results and expectations about the FND's interaction with the mixed radiation field inside the ISS.

Leitgab, Martin↗

Dose Calibration of the ISS-RAD Fast Neutron Detector

The ISS-RAD instrument has been fabricated by Southwest Research Institute and delivered to NASA for flight to the ISS in late 2015 or early 2016. ISS-RAD is essentially two instruments that share a common interface to ISS. The two instruments are the Charged Particle Detector (CPD), which is very similar to the MSL-RAD detector on Mars, and the Fast Neutron Detector (FND), which is a boron-loaded plastic scintillator with readout optimized for the 0.5 to 10 MeV energy range. As the FND is completely new, it has been necessary to develop methodology to allow it to be used to measure the neutron dose and dose equivalent. This talk will focus on the methods developed and their implementation using calibration data obtained in quasi-monoenergetic (QMN) neutron fields at the PTB facility in Braunschweig, Germany. The QMN data allow us to determine an approximate response function, from which we estimate dose and dose equivalent contributions per detected neutron as a function of the pulse height. We refer to these as the "pSv per count" curves for dose equivalent and the "pGy per count" curves for dose. The FND is required to provide a dose equivalent measurement with an accuracy of 10% of the known value in a calibrated AmBe field. Four variants of the analysis method were developed, corresponding to two different approximations of the pSv per count curve, and two different implementations, one for real-time analysis onboard ISS and one for ground analysis. We will show that the preferred method, when applied in either real-time or ground analysis, yields good accuracy for the AmBe field. We find that the real-time algorithm is more susceptible to chance-coincidence background than is the algorithm used in ground analysis, so that the best estimates will come from the latter.

Zeitlin, C.↗

Radiation Dosimetry Experiment (RaD-X): High-Altitude Balloon Flight Mission for Improving the NAIRAS Model

The NASA Radiation Dosimetry Experiment (RaD-X) high-altitude balloon mission was successfully launched from Fort Sumner, New Mexico USA on 25 September, 2015. Over 15 hours of science data were obtained from four dosimeters at altitudes above about 25 km. One of the main goals of the RaD-X mission is to improve aviation radiation model characterization of cosmic ray primaries by taking dosimetric measurements above the Pfotzer maximum before the production of secondary particles occurs. The second goal of the RaD-X mission is to facilitate the pathway toward real-time, data assimilative predictions of atmospheric cosmic radiation exposure by identifying and characterizing low-cost radiation measurement solutions.

Mertens, Christopher J.↗

Association of advanced hepatic fibrosis and sonographic visualization score: a dual-center study using ACR US LI-RADS

Purpose: To evaluate the association between imaging and clinical features and visualization scores, as specified by American College of Radiology (ACR) Ultrasound Liver Imaging Reporting and Data System (LI-RADS), on hepatocellular carcinoma (HCC) screening ultrasound examinations. Methods: In this dual-center retrospective study, HCC screening ultrasound reports containing ultrasound elastography measurements (January to September, 2017) were reviewed. Ultrasound point shear wave elastography and 2-dimensional shear wave elastography were used to assess liver stiffness; median shear wave velocity was translated to METAVIR fibrosis scoring, per previously published data. Reports were analyzed for subject age, sex, reason for HCC screening, spleen size, fibrosis scores, and assigned ultrasound visualization scores. Jonckheere–Terpstra trend and Kendall’s tau-b coefficient analyses were performed. Results: 714 subjects (mean age 55; 51% male, 49% female) were included. 308 (43%) subjects had clinically declared cirrhosis; 406 (57%) did not. Majority (535, 75%) of exams were adequate (Visualization Score A), 156 (22%) moderately limited (Visualization Score B), and 23 (3%) severely limited (Visualization Score C). Increasing spleen size and patient age were associated with worsening visualization scores (p < 0.001). Suboptimal visualization was also associated with clinically significant fibrosis (≥ F2) by elastography (Kendall’s tau-b = 0.181, p < 0.001) and clinically declared cirrhosis (Kendall’s tau-b = 0.433, p < 0.001). There was no association with patient sex. Conclusion: Using ACR Ultrasound LI-RADS visualization score assessment, majority (75%) of HCC screening exams were diagnostically adequate, and only 3% were severely limited. Sonoelastographic diagnosis of clinically significant fibrosis, as well as clinical cirrhosis, increased patient age, and spleen size, were associated with greater diagnostic limitations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The yield and patient factors associated with CT colonography C-RADS results in a non-screening patient population

Objectives: To determine the proportion of diagnostic computed tomography colonography (CTC) Reporting and Data System (C-RADS) categories in a non-screening population, and which patient factors are associated with a positive CTC (C2–4), a non-diagnostic CTC (C0), and potentially relevant extracolonic findings (ECF, E3–4). Methods: Diagnostic CTCs performed at a single academic center from 2017 to 2018 were retrospectively reviewed. For each examination, the indications, age, sex, admission status, and C-RADS categories were recorded. Multivariate logistic regression was performed of patient demographic factors and clinical indications, with adjusted odds ratios (OR) and 95% confidence intervals. Results: 1373 CTCs were included. The mean age was 66.4 ± 13 years (range 24–97). There were 782 women and 75 inpatients. The number of CTCs reported as C0–C4 were 194/1373 (14.1%), 970/1373 (70.6%), 77/1373 (5.6%), 86/1373 (6.3%), and 46/1373 (3.4%), respectively, and 134/1373 (9.8%), 960/1373 (69.9%), 173/1373 (12.6%), and 106/1373 (7.7%) CTCs were reported as E1–4, respectively. Factors that demonstrated the strongest associations were as follows: with C2–4, age groups 50–79 (OR 2.8, 95% confidence interval 1.4–6.1), 80–89 (6.2, 2.9–14.5) and ≥ 90 (7.6, 2.0–29.1), and inpatients (3.4, 1.8–6.4); with C0, age groups 50–79 (5.9, 2.2–24.4), 80–89 (9.8, 3.4–41.8), and ≥ 90 (22.5, 5.8–113.0), incomplete colonoscopy (3.2, 2.0–5.1) and melena or gastrointestinal bleeding (4.1, 1.8–9.4); and with E3–4, age groups 50–79 (1.6, 1.0–2.9), 80–89 (2.0, 1.1–3.9), and ≥ 90 (3.2, 1.2–8.8), and inpatients (2.3, 1.3–3.9). Conclusion: Older age is increasingly associated with a positive test, a non-diagnostic test and potentially relevant ECF. Inpatients are also associated with positive tests and E3–4 findings. Symptoms are not strongly associated with a positive CTC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Continuum radiated power density $(P^{\textrm{C}}_{\textrm{rad}})$ and effective charge $(Z_{\textrm{eff}})$ estimates from multi-energy photon-counting measurements

Multi-energy soft x-ray pinhole cameras have been designed, built, calibrated, and operated at Madison symmetric Torus, Alcator C-Mod, and more recently at Tokamak a configuration variable and Tungsten Environment in Steady-State Tokamak (WEST), to measure plasma emission across multiple energy ranges. Here we describe a new methodology to estimate the local continuum radiated power density and the plasma effective charge (Z eff ) directly from photon-counting measurements of the line-free continuum emission (Bremsstrahlung and Radiative Recombination) in several energy bands between 11 and 18 keV. This capability is particularly valuable for confinement systems using metal plasma-facing components, where x-ray losses from interactions with the sputtered wall can represent a significant fraction of the total radiated power (P rad ). The approach leverages a well-characterized detector responsivity, modeled by a complementary error function, and interprets the differential multi-energy measurements between adjacent energy levels through the probability density function of a Gaussian distribution. The implementation of this diagnostic technique is currently under development on the WEST tokamak, aiming at the goal of providing real-time P rad and Z eff measurements during long-pulse operation (up to 1000 s) in the 2026 campaign.

WEST↗

SU-F-J-20: Commissioning and Acceptance Testing of the C-Rad CatalystHD Surface Imaging System

Introduction: With the increasing use of surface-based, nonionizing image-guided radiotherapy (IGRT) systems, a comprehensive set of clinical acceptance and commissioning procedures are needed to ensure correct functionality and proper clinical integration. Although TG-147 provides a specific set of parameters, measurement methodologies have yet to be described. The aim of this study was to provide a comprehensive overview of the commissioning and acceptance analysis performed for the C-Rad CatalystHD imaging system. Methods and Materials: Methodology for the commissioning and acceptance of the C-Rad CatalystHD imaging system was developed using commercially available clinical equipment. Following TG-147 guidelines, the following tests were performed: integration of peripheral equipment, system drift, static spatial reproducibility and localization accuracy, static end-to-end analysis, static rotational accuracy, dynamic spatial accuracy, dynamic temporal accuracy, dynamic radiation delivery and a comprehensive end-to-end analysis. Results: The field of view (FOV) of the CatalystHD was 105×109×83 cm3 in the lateral, longitudinal and vertical directions. For thermal equilibrium and system drift, a thermal drift of 1.0mm was noted. A 45 min warmup time is recommended if the system has been shut off an extended period of time (>24 hours) before the QA procedure to eliminate any thermal drift. Spatial reproducibility was found to be 0.05±0.03 mm using a rigid phantom. For the static localization accuracy, system agreement with couch shifts was within 0.1±0.1 mm and positioning agreement with kV-CBCT was 0.16±0.10 mm. For static rotational accuracy, system agreement with a high precision rotational stage (0.01 deg precision) was within 0.10±0.07 deg. Dynamic spatial and temporal localization accuracy was found to be within 0.2±0.1 mm. Conclusion: A comprehensive commissioning and acceptance study was performed using commercially available phantoms and in-house methodologies to provide a performance evaluation of the CatalystHD imaging system.

60 APPLIED LIFE SCIENCES↗

Comparison of the effects of ionizing radiation at twelve dose rates from 0.0015 to 100 rad(Si)/s

Evidence is presented that two competing failure mechanisms exist in the Si-SiO2 system, with one mechanism dominating at low dose rates and the other at high. Much lower dose failures than expected were discovered at low dose rates (less than 0.1 rad(Si)/s) and very low dose rates (about 0.001 rad(Si)/s) in commercial SGS 4007 CMOS devices. These failure doses plotted versus dose rate have a bell-shaped curve, rather than the expected straight line (decreasing with increasing dose rate), indicating that a different failure mechanism is dominant at low dose rates than at high.

Goben, C. A.↗