Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIANT HEATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Lattice Boltzmann Scheme for Polarized Radiative Transfer in Planetary Atmospheres

Quantitative calculation of reflected polarized light from planets is of great significance to interpret the polarimetric observations of planetary atmospheres. In this work, we propose a lattice Boltzmann (LB) scheme for polarized radiative transfer in planetary atmospheres. The LB scheme obtains the Stokes vector through the vector LB equation performing simple collision and streaming processes. The vector radiative transfer equation is rigorously derived from the vector LB equation via the Maxwell iteration technique. Polarized radiative transfer of a single point on the planetary surface with Rayleigh and Mie scattering atmospheres are first accurately solved by our LB scheme. Afterward, we systematically investigate the disk-integrated polarization of finite and semi-infinite, conservative and nonconservative Rayleigh scattering planetary atmospheres. The disk-integrated phase curves of the Stokes parameters and degree of polarization and spherical and geometric albedos are produced, which are in good agreement with the benchmark results for different cases. The numerical results indicate that our LB scheme is efficient and accurate for polarized radiative transfer in planetary atmospheres. Our LB scheme is expected to provide a competitive numerical tool to interpret the polarimetric observations of planetary atmospheres.

47 OTHER INSTRUMENTATION↗

Observational Signatures of Planets in Protoplanetary Disks: Temperature Structures in Spiral Arms

High-resolution imaging of protoplanetary disks has unveiled a rich diversity of spiral structure, some of which may arise from disk-planet interaction. Using 3D hydrodynamics with β cooling to a vertically stratified background, as well as radiative-transfer modeling, we investigate the temperature rise in planet-driven spirals. In rapidly cooling disks, the temperature rise is dominated by a contribution from stellar irradiation, 0.3%–3% inside the planet radius but always < 0.5% outside. When cooling time equals or exceeds dynamical time, however, this is overwhelmed by hydrodynamic PdV work, which introduces a ~10%–20% perturbation within a factor of ~2 from the planet’s orbital radius. We devise an empirical fit of the spiral amplitude Δ(T)=(M{sub p}/M{sub th}){sup c}(f{sub PdV}e{sup -t{sub a}{sub r}{sub m}/t{sub c}}+f{sub rad}) to take into account both effects. Where cooling is slow, we find also that temperature perturbations from buoyancy spirals—a strictly 3D, nonisothermal phenomenon—become nearly as strong as those from Lindblad spirals, which are amenable to 2D and isothermal studies. Our findings may help explain observed thermal features in disks like TW Hydrae and CQ Tauri, and underscore that 3D effects have a qualitatively important effect on disk structure.

42 ENGINEERING↗

Low-Cost Radiant Heater for Rapid Response, High-Temperature Heating

High-temperature processing has an irreplaceable role in many research and industrial applications. Despite remarkable development spanning over a century, the pursuit of even higher thermal flux density and more rapid thermal transients has not slowed down. As part of the ongoing energy evolution, many industrial applications are transitioning from direct combustion of fossil fuels as primary energy sources to increasing electrification, capable of adapting to renewable power grids. Thus, there is an emerging need for electrical heaters that can replace burners and supply the heat demand, especially at the highest temperatures. In this study, we report on a radiant heater design that can achieve cyclic heating/cooling rates of up to 400 K min –1 and a temperature range in excess of 1,800 K, comparable to those of commercial infrared gold image furnaces, at high surface and volumetric power densities. The heater consists of a modular unit of incandescent tungsten filament and is enclosed in an evacuated ceramic envelope, chemically inert, tolerant of thermal shock, and impervious to gasses. The material and manufacture cost of such heaters, which is estimated at ~$0.05/W, is less than 0.03% of that for infrared gold image furnaces, which is at >$2/W. Tests of more than 10,000 demanding cycles (high temperature and high heating/cooling rate) over 350 h of total operational time and in different temperature ranges confirm the robust performance of radiant heater prototypes. The design is widely applicable to high-temperature reactor and furnace designs. In thermochemistry research and practice, these radiant heaters could offer multiple benefits compared to solar simulators, lasers, infrared gold furnaces, ceramic heaters, or direct concentration of solar input.

99 GENERAL AND MISCELLANEOUS↗

Substrate Effects When Using Photons to Make Perovskite Solar Cells

To shorten annealing time and minimize substrate heating, flash lamps that deliver short, intense light pulses, commonly called photonic curing, are used to replace thermal annealing using hot plates or ovens. This method is different from equilibrium heating in that the radiant energy is selectively absorbed by the film. The high-intensity light pulses produce a high peak temperature in the film. Because most processes follow Arrhenius behavior, reaching high temperatures allow chemical reactions/phase transformations to occur in a short time, significantly reducing the processing time. Often the results are non-intuitive. We will present fabricating flexible halide perovskite solar cells (PSCs) on indium tin oxide (ITO) coated Willow glass. The effect of ITO transmittance on the photonic curing of nickel nitrate sol-gel precursors into nickel oxide to fabricate hole transport layer and consequently the performance of PSCs. Unexpectedly, ITO samples processed by photonic curing show improved optical and electrical properties.

14 SOLAR ENERGY↗

Analysis of Frost Formation and Novel Defrost Techniques for Commercial Refrigeration Applications (NFE-19-07879)

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test a heat exchanger defrosting approach using radiant energy, including ultraviolet-C, -B, and -A. A preliminary test conducted at Oak Ridge National Laboratory demonstrated the concept of ultraviolet-based defrosting, which melts frost on the fin surface of a heat exchanger without increasing its overall temperature, thereby offering a new defrosting method that does not interrupt heat exchanger operation. Building on this key finding, this CRADA outlines a plan for upgrading the test equipment and for further testing to bridge the gap between the concept and its feasibility for industrial applications. This report also provides a brief review of existing defrosting technologies, the current state of the experimental system, and future parametric experiment plans.

99 GENERAL AND MISCELLANEOUS↗

Analysis of Frost Formation and Novel Defrost Techniques for Commercial Refrigeration Applications

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test a heat exchanger defrosting approach using radiant energy, including ultraviolet-C, -B, and -A. A preliminary test conducted at Oak Ridge National Laboratory demonstrated the concept of ultraviolet-based defrosting, which melts frost on the fin surface of a heat exchanger without increasing its overall temperature, thereby offering a new defrosting method that does not interrupt heat exchanger operation. Building on this key finding, this CRADA outlines a plan for upgrading the test equipment and for further testing to bridge the gap between the concept and its feasibility for industrial applications. This report also provides a brief review of existing defrosting technologies, the current state of the experimental system, and future parametric experiment plans.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photonic curing for innovative fabrication of flexible metal oxide optoelectronics

Abstract Flexible optoelectronics, based on non-planar substrates, hold promise for diverse applications such as wearables, health monitors, and displays due to their cost-effective manufacturing methods. Despite the superior properties of metal oxides, the challenge of processing them at high temperatures incompatible with plastic substrates necessitates innovative annealing approaches. Photonic curing, which delivers microsecond to millisecond broadband (200–1500 nm) light pulses on a sample, emerges as a viable solution. Depending on the optical properties, the targeted film absorbs the radiant energy resulting in rapid heating while the transparent substrate absorbs a minimal amount of light and remains at ambient temperature. The light intensity can be high, but since the light pulse is short, the total energy absorbed by the sample remains low and will not damage the plastic substrate. This perspective explores the innovative application of photonic curing to fabricate flexible metal oxide optoelectronics, including thin-film transistors, metal–insulator–metal devices, solar cells, transparent conductors, and Li batteries, emphasizing the conversion of sol–gel precursors to metal oxides. However, this technique was initially developed for sintering metal nanoparticles to conductive patterns and poses intriguing challenges in explaining its mechanism for metal oxide conversion, especially considering the limited absorption of visible light by most sol–gel precursors. The review delves into UV-induced photochemistry, common flexible metal-oxide optoelectronic components, and non-intuitive distinctions between photonic curing and thermal annealing. By elucidating the distinctive role of photonic curing in overcoming temperature-related challenges and advancing the fabrication of flexible metal oxide optoelectronics, this perspective offers valuable insights that could shape the future of flexible optoelectronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An economics-by-design approach to a radiant integrated thermophotovoltaic microreactor system

This paper presents an application of the economics-by-design approach to the Radiant Integrated Thermo-photovoltaic Microreactor System (RITMS). The RITMS design is unique in that it directly couples a critical fission reactor with thermo-photovoltaic (TPV) panels for high efficiency energy conversion. This significant shift from electric conversion using traditional dynamic heat pumps leads to a simpler and more reliable system without turbomachinery and high pressurization. In working towards wrapping up the early design work, the economics-by-design approach, which centers economic competitiveness as the optimization parameter, is well suited in making a final determination on viability. This paper describes the computational sequence that was developed to couple the radiative and conductive heat transfer and feed operational performance to cost estimation. The framework was applied to maximize the power of the system, while minimizing the fuel enrichment. This method is applied to a reference RITMS design as part of a parametric sensitivity study, which revealed that the system is under moderated and that single unit plants could produce power as low as 300 dollar/MWh. This price point supports the notion that early in the RITMS design implementation, adoption into niche markets as a first-of-a-kind technology is possible. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effectiveness of street trees in reducing air temperature and outdoor heat exposure in Las Vegas

Urban greening and especially tree planting strategies are being widely planned and implemented to mitigate urban overheating and thermal stress in many urban areas. However, the effectiveness of these strategies depends on multiple factors, including urban morphology, environmental conditions, and tree characteristics. This study investigates the effects of street tree planting strategies on air temperature and outdoor heat exposure in Las Vegas by combining an urbanized mesoscale climate model coupled to a multi-layer street tree model (Weather Research and Forecasting-BEP-Tree; Δ x = 900 m) with a microscale pedestrian heat exposure model (Temperatures of Urban Facets for Pedestrian; Δ x = 1 m). A series of simulations are conducted for July and August 2022. Large city-wide increases of a drought tolerant tree species cool air temperature mainly during the nighttime (up to 1.5 °C), with daytime effects being limited due to leaves shedding sensible instead of latent heat as stomata close in response to high vapor pressure deficits. Increased evaporative cooling is achieved with a different tree species (double at night, and reaching 0.4 °C during the day), but water requirements increase threefold. Despite their relatively small effect on air temperature during the day, trees provide significant shade by intercepting solar radiation, reducing mean radiant temperature (up to 16 °C) and enhancing outdoor thermal comfort, a major benefit of street trees in hot arid climates. The nighttime cooling of trees and the daytime reduction of radiant loading show potential to reduce the heat-related health impacts. Our results highlight the need to evaluate the effects of street trees on a case-by-case basis.

54 ENVIRONMENTAL SCIENCES↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC

Utilities and grid operators worldwide are under significant pressure to incorporate intermittent renewable sources while strategizing on how to maintain the necessary stability and reliability of the grid. The development of a power plant which will be capable of flexible operation to meet the needs of the grid as more intermittent sources like wind and solar energy are incorporated is key to maintain the reliability of the grid. Through the use of innovative and cutting-edge technologies that improve efficiency and reduce carbon emissions, and being small compared to today's conventional utility-scale power plants, the modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. Specifically, the process offers: 1) a modular plant design that allows for better operational flexibility; 2) the utilization of fuel-staging and pressurized oxy-combustion, resulting in smaller plant size, improved plant efficiency, and reduced costs for pollutant and CO2 removal compared to traditional power plants with post-combustion capture technology; and 3) the use of small modular boilers and pollutant removal units that can be constructed off-site leading to reduced capital costs for the plant. WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustor-boiler system and the direct contact cooler. To demonstrate the boiler convective section and to obtain critical data for commercial-scale pressurized boiler design, a simulated convective heat transfer boiler test section was designed and integrated with the combustor (radiant section). A direct contact cooler (DCC) was integrated with the combustor-boiler to demonstrate the dynamic operation of the integrated system and the performance of the DCC, including the efficiency for simultaneous removal of NOx and SOx. This talk will present an update on the evaluation of the critical components for system integration, including heat transfer data from the simulated boiler, scrubbing efficiency for the DCC under different operating conditions, and CFD modeling and validation for burner and boiler development.

Magalhaes, Duarte↗

Development of an Advanced Multiphysics Simulation Capability for Radiant's Microreactor Design

Argonne National Laboratory and Idaho National Laboratory, through a Department of Energy Gateway for Accelerated Innovation in Nuclear Voucher, supported key analysis needs of Radiant related to (i) air jacket thermal fluid performance, (ii) evaluation of decay heat source terms defining air jacket technical requirements, and (iii) assessment of modeling methodologies employed for core analysis. All of these activities center on numerical simulation of various aspects of Kaleidos using the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, the Cardinal multiphysics application, the OpenMC Monte Carlo code, and the Nek5000 computational fluid dynamics (CFD) code. This project builds upon an earlier Nuclear Energy Advanced Modeling and Simulation (NEAMS) Thermal-Hydraulic (T/H) Center of Excellence (CoE) project focused on initial demonstration of Cardinal multiphysics simulation of High Temperature Gas Reactors (HTGRs) and now focuses on Radiant’s Kaleidos concept.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗