Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing how size distribution and concentration affect echogenicity of ultrasound contrast agents

Here, we investigated the effects of UCA gas bubble size distribution and concentration on the generated ultrasound echogenicity signal. Gas bubble size characterization using Coulter Counter and cryogenic-SEM revealed the hollow structure and rare presence of microbubbles >10 µm in a commercial UCA product, Lumason™. Volume-weighed size and concentration were observed to be more sensitive to changes in UCA bubble stability than number-weighted size and concentration. Size distribution measurements showed that the force (e.g., shaking/agitation energy) used to redisperse the sample did not affect the size distribution, concentration, or echogenicity of the UCA sample. The ultrasound backscattering coefficient (BSC) of size fractionated and serial diluted microbubbles showed that the echogenicity signal correlates most with UCA bubble concentration, especially volume-weighted concentration. Findings from this study may be used to support demonstrating the equivalence of a generic UCA product to the reference listed drug.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical simulation of terahertz radiation by laser-driven plasma dipole oscillation

Laser-plasma interactions have many theoretical and technological applications. One is the use of coherently accelerated electrons to provide novel sources of THz radiation. Our research focuses on simulating the cross/self-interactions between two high intensity, ultra-short, counter propagating and detuned laser pulses and an initial neutral target for controlled ionization. Unlike our previous studies of laser-matter interaction over preformed plasma, we explore the injection and collision of laser pulses to induce background plasma driven by the self-guided laser wakefield mechanism, which is then used to perturb the plasma resulting in induced dipole oscillations leading to transverse radiation. Inducing a cylindrical spatial plasma column within the laser beam radius regime provides a stable, spatially localized plasma channel. The emitted radiation from the plasma dipole oscillation (PDO) will not be affected by surrounding plasma absorption, resulting in effective radiation distribution. Finally, results include 3D EM-PIC simulations and a comparison of the self- ionizing plasma against the preformed plasma to assess the efficiency of the mechanisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Psychosomatic Bias in Low-dose Radiation Epidemiology: Assessing the Role of Radiophobia and Stress in Cancer Incidence

Abstract Historical assessment of radiation effects at low doses (below 0.2 Sv) are generally the result of back extrapolation from higher doses, which are known to have a linear relation between risk and dose. There are multiple counter-examples, and some literature argues that a threshold, nonlinear, or even a beneficial effect (hormeisis) can occur from radiation below these doses. The common theme found in all of these studies stems from the traditional approach of correlating disease rates to stimulus and then effectively curve-fitting the result toward zero dose. What has not been considered in general are the personal stress levels of the exposed individuals due to fear of cancer from low doses. The increased levels of cortisol due to the psychological stress from fear or depression has been shown in the literature to increase cancer probability. The extent to which low-dose exposed individuals were highly fearful or stressed from the radiation exposure would then give rise to elevated cancer based on stress rather than a fundamental radiogenic mechanism. If the population under epidemiological study is aware of a potential historical exposure (no matter how small) and has then lived under stress from fear or depression due to that exposure, the psychosomatic effects will bias the epidemiology accordingly and so should be quantified and accounted for as done with the effects of smoking. Health Phys. 129(0):000-000; 2025

Environmental Sciences & Ecology↗

Probing shocks interacting with radiation waves with the Radishock experiment

Both radiation flows and shocks have been extensively studied in the laboratory in the past few decades due to their critical roles in many astrophysical and high-energy density physics processes. In the Radishock experiment, a halfraum-powered radiation wave is driven into a low-density foam and interacts with an ablatively driven, counter-propagating shock. The interacting waves produce a spike in energy density with a temperature greater than the local temperature of the individual waves. As in the successful predecessor experiment, COAX, the primary diagnostic uses absorption spectroscopy at many locations down the cylindrical target, enabling a spatial temperature inference of the radiation wave and its interactions with the shock. Combined with a radiography diagnostic that is capable of imaging the shock and interaction features, we are able to study and inform model predictions of the interaction spike phenomenon. We describe the underlying physics behind the shock interactions with the radiation front and the implications of this experimental study for a broad range of astrophysical phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear forensics: How science helps stop the trafficking of nuclear materials

Nuclear forensics is an essential activity in support of national counter-nuclear smuggling operations, as it can be used to provide unique and useful data to law enforcement for the prosecution of criminal nuclear smugglers and traffickers. Nuclear forensics can also be used to determine the origin of nuclear materials that have fallen out of regulatory control, allowing for the identification of weaknesses and vulnerabilities in the safeguarding of nuclear materials, while also generating a deterrent effect through attribution to the legal and responsible owners of nuclear materials out of regulatory control. This article describes the benefits of a nuclear forensics capability to any country in possession of nuclear materials, and describes how nuclear forensics can support an investigation into the origin of interdicted nuclear materials, using a case study of a nuclear materials interdiction in Australia to describe how nuclear forensics works in practice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Fast and sensitive measurements of sub-3 nm particles using Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM)

New particle formation (NPF) is the atmospheric process whereby gas molecules react and nucleate to form detectable particles. NPF has a strong impact on Earth's radiative balance as it produces roughly half of global cloud condensation nuclei. However, the time resolution and sensitivity of current instrumentation are inadequate in measuring the size distribution of sub-3 nm particles, the particles critical for understanding NPF. Here we present the Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM), a method to measure the concentrations of freshly nucleated particles. The CPC FARM consists of five CPCs operating in parallel, each configured to operate at different detectable particle sizes between 1–3 nm. This study explores two methods to calculate the size distribution from the differential measurements across the CPC channels. The performance of both inversion methods was tested against the size distribution measured by a pair of stepping particle mobility sizers (SMPSs) during an ambient air sampling study in Pittsburgh, PA. Observational results indicate that the CPC FARM is more accurate with higher time resolution and sensitivity in the sub-3 nm range compared to the SMPS.

Cheng, Darren [Carnegie Mellon Univ., Pittsburgh, ↗

Investigation of Radiological Contamination at Parks in the Gateway National Recreation Area - 20350

In 2005, the National Park Service was notified that elevated radiation levels were detected at Great Kills Park during a baseline radiological mapping effort conducted by the Counter Terrorism Bureau of the New York City Police Department and the United States Department of Energy. Great Kills Park is in the Staten Island Unit of the Gateway National Recreation Area. A records search determined that approximately 280 acres of the park was established over an area in which the New York City Department of Sanitation placed approximately 15.1 million cubic yards of waste fill from 1944 to 1948. Since 2005, a series of response actions and investigations were conducted on behalf of the National Park Service to mitigate risk to human health and the environment and to determine the nature of radiological contamination at Great Kills Park. The findings support that radiological contamination is related to certain components of waste fill, including incinerator residue from both on and offsite incinerators, coal ash from the historical use of coal-fired boilers for heating, and incidental radiological artifacts in the waste fill due to their historical use and subsequent disposal. A majority of the radiological artifacts were determined to contain radium-226 and included radioluminescent markers, radium impregnated switch board buttons, radium paint containers, and brachytherapy devices. The National Park Service has several other Parks in the Gateway National Recreation Area that were established in areas with a similar history to Great Kills Park, and overlie waste fill historically placed during landfilling operations, including Spring Creek Park and Dead Horse Bay. Over the last year, the National Park Service has performed additional radiological investigations at Great Kills Park as part of the ongoing Remedial Investigation under the Comprehensive Environmental Response, Compensation, and Liability Act. In addition, preliminary radiological investigations were performed at Spring Creek Park and Dead Horse Bay Park in the Jamaica Bay Unit of Gateway National Recreation Area. These investigation activities identified gamma radiation levels above the ambient level, several of which were attributable to radiological artifacts similar in nature to those recovered at Great Kills Park. Ongoing investigations at Parks in the Gateway National Recreation Area support an association between radiological contamination and historical landfilling practices that were common prior to the regulation and control of radioactive materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARM Data for Examining the Ice-Nucleating Particles from SGP Part II (ExINP-SGP II) Aerodynamic Particle Sizer, Condensation Particle Counter, and Meteorological Instrument Data Analysis

Knowledge of airborne particulate matter (PM), especially the particles that have supermicron diameters, is key for understanding ice-nucleating particles (INPs). Supported by the Atmospheric Radiation Measurement (ARM) user facility, we sampled PM and surface soil materials at the Southern Great Plains observatory (SGP; 36° 36′ 18″ N, 97° 29′ 6″ W) to systematically compare the INP abundance and ice nucleation efficiency of different SGP samples (i.e., airborne versus surface materials). The field campaign, named Examing INP from SGP II (ExINP-SGP II), was conducted from 20 January to 20 April, 2021. Our data analysis products include (1) physical surface sorption characterization data (i.e., BET, pore volume) of two sets of samples -- SGP Soil and USDA, (2) X-ray diffraction spectra for the same two samples, (3) immersion freezing assay-based ice nucleation active mass density data as a function of freezing temperature for both ambient and surface samples, and (4) time-series data of ambient meteorological conditions, concentration particle counter-derived aerosol particle concentration, and aerosol particle sizer measurement during ExINP-SGP II.

54 ENVIRONMENTAL SCIENCES↗

Sulfuric Acid New Particle Formation Field Campaign Report

This campaign aimed to measure gaseous sulfuric acid concentrations at the surface level using a newly developed sulfuric acid dimethylamine-reactive condensation particle counter (SAD-RCPC). Sulfuric acid is a key nucleation precursor and is the likely driving compound for new particle formation at the Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory. The SAD-RCPC will be deployed in the future at ARM SGP (AFC010010: "Vertically Resolved Nucleation Precursors at SGP") scheduled for 2024. The campaign was in conjunction with Eleanor Browne's campaign (AFC010075: Boundary-layer gradients in new particle formation) and took place from 05/7/23 to 5/21/23. The measured sulfuric acid concentrations by the SAD-RCPC will be compared to concentrations measured by Browne's chemical ionization mass spectrometer (CIMS). The SAD-RCPC consisted of a glass flow reactor coupled to a 1-nm diethylene glycol condensation particle counter (DEG CPC). Sampled air was mixed with a high concentration of dimethylamine vapor (~1 ppbv). Sulfuric acid within the sampled gas nucleated with dimethylamine to form detectable 1-nm particles. The measured particle concentration was converted to sulfuric acid concentration using nucleation reaction kinetics. The pulse height distribution of particles detected by the DEG CPC was observed using a multi-channel analyzer. Large pre-existing particles were separated from the freshly formed particles in the SAD-RCPC from the pulse height distribution (PHD). During the short campaign, seven new particle formation events were observed. The SAD-RCPC detected an increase in sulfuric acid concentration, but this also coincided with an increase in pre-existing <3 nm particle concentrations. In addition, Browne's CIMS detect sulfuric acid concentrations in the range of 10 5 -10 6 cm -3 .

54 ENVIRONMENTAL SCIENCES↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, G. [Thomas Jefferson National Accelerator↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, Gianluigi [Thomas Jefferson National Acce↗