At least 37 records · Page 2

Research progress in radiation detectors, pattern recognition programs, and radiation damage determination in DNA

The radiological implications of statistical variations in energy deposition by ionizing radiation were investigated in the conduct of the following experiments: (1) study of the production of secondary particles generated by the passage of the primary radiation through bone and muscle; (2) the study of the ratio of nonreparable to reparable damage in DNA as a function of different energy deposition patterns generated by X rays versus heavy fast charged particles; (3) the use of electronic radiography systems for direct fluoroscopic tomography and for the synthesis of multiple planes and; (4) the determination of the characteristics of systems response to split fields having different contrast levels, and of minimum detectable contrast levels between the halves under realistic clinical situations.

Baily, N. A.

Advanced Radiation Detectors and Detector Systems Research

Real‐time awareness of space radiation is critical for missions beyond LEO. Missions to the Moon, Mars, Near‐Earth‐Objects (NEOs), inner and outer planets, as well as other destinations in space, will require embedded instrumentation to provide feedback for “smart”, adaptive control systems. Precision instrumentation will also be needed to provide improved data for space radiation modeling and space weather forecasting and awareness. Compact instrumentation on small platforms such as CubeSats and other small space‐faring vehicles will provide a better understanding of the space radiation environment by supplying data from multiple locations in space where information is yet unknown. Compact integrable solid‐state detectors with low noise and high tolerance of operation in a radiation environment are enabled by the application of Wide Band Gap semiconductors as radiation detectors. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies that enable improved instruments for space science missions. A variety of radiation detectors are under development, such as silicon carbide semiconductor detectors, for applications to space science, lunar prospecting, and fission power systems.

Field and particle detectors

Calibration of the active radiation detector for Spacelab-One

The flight models of the active radiation detector (ARD) for the ENV-01 environmental monitor were calibrated using gamma radiation. Measured sensitivities of the ion chambers were 6.1 + or - 0.3 micron rad per count for ARD S/N1, and 10.4 + or - 0.5 micron rad per count for ARD S/N2. Both were linear over the measured range 0.10 to 500 m/rad hour. The particle counters (proportional counters) were set to respond to approximately 85% of minimum ionizing particles of unit charge passing through them. These counters were also calibrated in the gamma field.

Source record

Processing circuitry for single channel radiation detector

Processing circuitry is provided for a high voltage operated radiation detector. An event detector utilizes a comparator configured to produce an event signal based on a leading edge threshold value. A preferred event detector does not produce another event signal until a trailing edge threshold value is satisfied. The event signal can be utilized for counting the number of particle hits and also for controlling data collection operation for a peak detect circuit and timer. The leading edge threshold value is programmable such that it can be reprogrammed by a remote computer. A digital high voltage control is preferably operable to monitor and adjust high voltage for the detector.

Holland, Samuel D.

Radiation-detector optical-imaging device is of simplified construction

A simplified radiation detector was designed which employs an activated continuous front surface consisting of either the diffused or barrier type of semiconducting material with a grid structure on the nonactivated side of the detector. Its form may be either a rectangular coordinate or a polar coordinate system.

Source record

High-energy cosmic-ray electrons - A new measurement using transition-radiation detectors

A new detector for cosmic-ray electrons, consisting of a combination of a transition-radiation detector and a shower detector, has been constructed, calibrated at accelerator beams, and exposed in a balloon flight under 5 g/sq cm of atmosphere. The design of this instrument and the methods of data analysis are described. Preliminary results in the energy range 9-300 GeV are presented. The energy spectrum of electrons is found to be significantly steeper than that of protons, consistent with a long escape lifetime of cosmic rays in the galaxy.

Hartmann, G.

A new thermal radiation detector using optical heterodyne detection of absorbed energy

The operating principles of a new kind of room-temperature thermal radiation detector are described. In this device modulated light heats a gas, either directly or by conduction from a thin absorbing membrane, and the resultant change in density of the gas is detected by optical heterodyning. The performance of a membrane device of this kind agrees well with the predictions of theory.

Davis, C. C.

Measurement of a high electrical quality factor in a niobium resonator for a gravitational radiation detector

The mechanical and electrical quality factors of a 10-g niobium resonator were measured at 4.4 K and were found to be 8.1 x 10 to the 6th, and 3.8 x 10 to the 6th, respectively. The value for the electrical quality factor is high enough for a system operating at 50 mK at a sensitivity level of one phonon. The resonator's low damping properties make it suitable for use as a transducer for a cryogenic three-mode gravitational radiation detector. A practical design is given for the mounting of the resonator on a 2400-kg aluminum-bar detector. Projections are made for the sensitivity of a 2400-kg bar instrumented as a three-mode system with this resonator inductively coupled to a SQUID.

Folkner, W. M.

Charge-carrier mobilities in Cd(0.8)Zn(0.2)Te single crystals used as nuclear radiation detectors

Charge-carrier mobilities were measured for the first time in Cd(0.8)Zn(0.2)Te single crystals using time-of-flight measurements of charge carriers produced by short (10 ns) light pulses from a frequency-doubled Nd:YAG laser (532 nm). The electron mobility displayed a T exp -1.1 dependence on the absolute temperature T in the range 200-320 K, with a room-temperature mobility of 1350 sq cm/V s. The hole mobility displayed a T exp -2.0 dependence in the same temperature range, with a room-temperature mobility of 120 sq cm/V s. Cd(0.8)Zn(0.2)Te appears to be a very favorable material for a room-temperature electronic nuclear radiation detector.

Burshtein, Z.

Micro-Fabricated Solid-State Radiation Detectors for Active Personal Dosimetry

Active radiation dosimetry is important to human health and equipment functionality for space applications outside the protective environment of a space station or vehicle. This is especially true for long duration missions to the moon, where the lack of a magnetic field offers no protection from space radiation to those on extravehicular activities. In order to improve functionality, durability and reliability of radiation dosimeters for future NASA lunar missions, single crystal silicon carbide devices and scintillating fiber detectors are currently being investigated for applications in advanced extravehicular systems. For many years, NASA Glenn Research Center has led significant efforts in silicon carbide semiconductor technology research and instrumentation research for sensor applications under extreme conditions. This report summarizes the technical progress and accomplishments toward characterization of radiation-sensing components for the recommendation of their fitness for advanced dosimetry development.

Wrbanek, John D.