Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIO TELEMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Enhanced Radio Frequency Carrier Margin Improvements for an Array of Receiving Systems with Unequal Predetection Signal-to-noise Ratios

Enhanced radio frequency carrier margin improvement for arrayed receiving systems for coherent reception which provides a significant carrier sensitivity improvement with a resultant decrease in telemetry radio loss due to reduction in rms phase noise at low carrier margins is discussed. A significant increase in doppler rate capability is realized relative to that obtained by switching to a narrower tracking loop bandwidth to obtain the same carrier sensitivity improvement. The situation for arrayed receiving systems with unequal apertures and statisically independent predetection noise is examined.

Brockman, M. H.↗

Long distance tracking of birds

The application of radio telemetry techniques to the long distance tracking of birds is discussed. The types of equipment developed and methods for attachment to a bird are described. The operating range of the radio transmitter receiver system is examined, and methods for acquiring and analyzing the data are explained.

Cochran, W. W.↗

Performance characteristics for an array of two receiving systems with unequal predetection signal-to-noise ratios and enhanced radio frequency carrier margin improvement

Enhanced radio frequency carrier margin improvement for arrayed receiving systems for coherent reception of phase modulated signals with residual carrier provides a significant reduction in carrier loop phase noise and increase in signal to noise ratio in the RF carrier tracking loop with an attendant reduction in telemetry radio loss. A significant increase in Doppler frequency rate capability is also realized relative to operating at a narrower tracking loop bandwidth to obtain the same carrier sensitivity improvement. These performance characteristics are examined for an array of two receiving systems with unequal apertures and statistically independent predetection noise.

Brockman, M. H.↗

Performance characteristics for an array of two receiving systems with equal apertures and enhanced radio frequency carrier margin improvement

Enhanced radio frequency carrier margin improvement for arrayed receiving systems for coherent reception of phase modulated signals with residual carrier provides a significant reduction in carrier loop phase noise and an increase in the signal to noise ratio in the RF carrier tracking loop with an attendant in telemetry radio loss. A significant increase in doppler frequency rate capability is also realized relative to operating at a narrower tracking loop bandwidth to obtain the same carrier sensitivity improvement. These performance characteristics are examined for an array of two receiving sysems with equal apertures and statistically independent prediction noise.

Brockman, M. H.↗

Hand-Held Units for Short-Range Wireless Biotelemetry

Special-purpose hand-held radiotransceiver units have been proposed as means of short-range radio powering and interrogation of surgically implanted microelectromechanical sensors and actuators. These units are based partly on the same principles as those of the units described in "Printed Multi- Turn Loop Antennas for RF Biotelemetry" (LEW-17879-1), NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48. Like the previously reported units, these units would make it unnecessary to have wire connections between the implanted devices and the external equipment used to activate and interrogate them. Like a unit of the previously reported type, a unit of the type now proposed would include a printed-circuit antenna on a dielectric substrate. The antenna circuitry would include integrated surface-mount inductors for impedance tuning. Circuits for processing the signals transmitted and received by the antenna would be included on the substrate. During operation, the unit would be positioned near (but not in electrical contact with) a human subject, in proximity to a microelectromechanical sensor or actuator that has been surgically implanted in the subject. It has been demonstrated that significant electromagnetic coupling with an implanted device could be established at a distance of as much as 4 in. (.10 cm). During operation in the interrogation mode, the antenna of the unit would receive a radio telemetry signal transmitted by the surgically implanted device. The antenna substrate would have dimensions of approximately 3.25 by 3.75 inches (approximately 8.3 by 9.5 cm). The substrate would have a thickness of the order of 30 mils (of the order of a somewhat less than a millimeter). The substrate would be made of low-radiofrequency- loss dielectric material that could be, for example, fused quartz, alumina, or any of a number of commercially available radio-frequency dielectric composite materials. The antenna conductors would typically be made of copper or a combination of chromium and gold. The choice of metal and the thickness of the metal layer(s) would depend on the choice of substrate material. For example, on a quartz or alumina substrate, one would typically use a layer of chromium 150 A thick and a layer of gold 2 m thick. The proposed units and the implanted devices that they would interrogate or activate would be inherently safe to use. They would operate at low radiated-power levels for short interrogation times (typically, milliseconds). Hence, there would be little local heating of tissues surrounding the implanted devices and little absorption of radio energy by such sensitive body parts as the eyes and the brain. Because the implanted devices would not depend on battery power and would be activated only during short interrogation intervals and would otherwise be in the goff h state most of the time, the useful lifetimes of the implanted devices would be greater than those of comparable battery-powered implanted devices. The compactness of the hand-held transceiver units would facilitate transport and storage and would facilitate self-diagnosis by patients able to handle the units while away from medical facilities.

Miranda, Felix A.↗

Preliminary design of a tornado probe

Rocket probe launched by aircraft for measuring pressure, temperature, magnetic field and wind velocity around tornado vortex through radio telemetry

Agee, E. M.↗

Telecommunications and data acquisition systems support for the Viking 1975 mission to Mars, volume 5

The support provided by the Deep Space Network to the Viking Project from 1 June 1978 to 30 April 1980 is described. The project was supported by the worldwide network of Deep Space Stations with 26- and 64-meter-diameter antennas, together with a ground communications system, for the transmission of commands, telemetry, radio metric data, and operational instructions between the stations and the network operation control center in Pasadena, California. Assistance was substantially less than in the previous phases of the Viking Project in order to provide adequate support to the Pioneer and Voyager Projects.

Larkin, W. E.↗

Digital Extraction Of Doppler Shift In An Advanced Receiver

Report describes demonstration of ability of Advanced Receiver II (ARX II) to extract Doppler shifts in radio telemetry signals from spacecraft by digital processing. Frequency of sampling clock fixed and derived from frequency-and-timing subsystem. Although this can result in noninteger number of samples per symbol, it enables digital extraction of Doppler shift. ARX II operates with older receiver called "Block IV". ARX II performed at least as well as, and in most cases better than, Block IV.

Hinedi, Sami M.↗

Effects of gravity on the circadian period in rats

The effect of increased gravity force on the circadian period of body temperature and activity of rats was investigated using rats implanted with a small radio telemetry device and, after a 2-week recovery and a 3-week control period at 1G, rotated at for 4 weeks at a constant 2G field in a 18-ft-diam centrifuge. Measurements of the mean freerunning period of the temperature and activity rhythms after 10 days showed that the exposure to 2G led to a functional separation of the pacemakers that regulate the activity and the temperature in the animals. Each pacemaker reacted differently: the activity period increased and the temperature period decreased. By the third or the fourth week, the activity and the temperature periods have returned to 1G control levels.

Murakami, Dean M.↗

Crew Activity Report / Flight Day 7

The Atlantis Space Shuttle crew (Mission Commander James D. Halsell, Jr., Pilot Scott J. Horowitz, Mission Specialists Mary Ellen Weber, Jeffrey N. Williams, James S. Voss, Susan J. Helms, and Yuri Vladimirovich Usachev) completed several activities including: (1) installation of final battery in the International Space Station; (2) installation of new storage compartments behind panels in the Zarya module; (3) installation of a new Radio Telemetry System; (4) firing of Atlantis steering jets to perform the second part of three-day maneuver to raise the station's altitude; and (5) transferring more than a ton of gear to the station to await use by the first resident crew.

Source record↗

Implementation of an Antenna Array Signal Processing Breadboard for the Deep Space Network

The Deep Space Network Large Array will replace/augment 34 and 70 meter antenna assets. The array will mainly be used to support NASA's deep space telemetry, radio science, and navigation requirements. The array project will deploy three complexes in the western U.S., Australia, and European longitude each with 400 12m downlink antennas and a DSN central facility at JPL. THis facility will remotely conduct all real-time monitor and control for the network. Signal processing objectives include: provide a means to evaluate the performance of the Breadboard Array's antenna subsystem; design and build prototype hardware; demonstrate and evaluate proposed signal processing techniques; and gain experience with various technologies that may be used in the Large Array. Results are summarized..

array↗

Remote, PCM-controlled, multi-channel radio frequency FM telemetry system for cryogenic wind tunnel application

A telemetry system used in the NASA-Langley cryogenic transonic wind tunnel to obtain rotational strain and temperature data is described. The system consists of four FM transmitters allowing for a remotely controlled PCM combination. A rotating four-contact mercury slip-ring is used as an interface between the fixed and rotating mechnical structures. Over 60 channels of data on the main fan disk and blade structures have been obtained. These data are studied to verify computer predictions and mechanical life. A series of block diagrams are included.

Diamond, John K.↗

Long Term Performance Metrics of the GD SDR on the SCaN Testbed: The First Year on the ISS

The General Dynamics (GD) S-Band software defined radio (SDR) in the Space Communications and Navigation (SCaN) Testbed on the International Space Station (ISS) provides experimenters an opportunity to develop and demonstrate experimental waveforms in space. The SCaN Testbed was installed on the ISS in August of 2012. After installation, the initial checkout and commissioning phases were completed and experimental operations commenced. One goal of the SCaN Testbed is to collect long term performance metrics for SDRs operating in space in order to demonstrate long term reliability. These metrics include the time the SDR powered on, the time the power amplifier (PA) is powered on, temperature trends, error detection and correction (EDAC) behavior, and waveform operational usage time. This paper describes the performance of the GD SDR over the first year of operations on the ISS.

radio telemetry↗