Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOCHEMICAL ANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Completion document for MRT 8824 - Upgrade NIF’s gaseous radiochemistry diagnostics (RAGS) to support weapons science

This milestone highlights the successful upgrade and deployment of the Radiochemical Analysis of Gaseous Samples (RAGS) system, which delivers high-quality measurements (<20% uncertainty) of activated gaseous species from NIF implosions. These measurements are critical for supporting Stockpile Stewardship Program (SSP) relevant platforms, including LANL’s Double Shell and LLNL’s Pushered Single Shell campaigns. The RAGS diagnostic technique enables analysis of short-range mixing in implosions using high-Z shells, which are otherwise inaccessible to conventional x-ray diagnostic methods. By facilitating the investigation of high-Z material mixing into fusion burn, this system provides essential data for quantifying and interpreting results in high-energy density (HED) experiments. This report details the physics motivation, diagnostic fundamentals, planned and enacted upgrade work, and the quantification of uncertainty for the upgraded system.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Laboratory Analysis for Radiological Events

Presentation for an International Atomic Energy Agency sponsored workshop on Consequence Management (virtual). Presentation sponsored by DOE NA-81

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Adjoint sensitivity analysis and data assimilation for verification of dry storage cask contents

Dry cask storage is a method for interim storage of spent fuel assemblies which contain fissile isotopes of uranium and plutonium. These can present a proliferation concern and consequently there is a need for non-destructive testing methods to verify a dry cask's contents for proliferation protection. We present an application of adjoint sensitivity analysis and data assimilation to a multigroup diffusion model of dry cask storage. Adjoint sensitivity analysis allows the efficient calculation of sensitivities for use in data assimilation to calibrate imprecisely known parameter values and data consistency tests to detect diversion scenarios. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Innovative high-temperature ammonium bifluoride fusion and rapid analysis of elements with nuclear forensic value

High-temperature ammonium bifluoride (ABF) fusions were evaluated for potential use in rapid dissolution of post-detonation nuclear debris. The ABF fusion was carried out in a Pt crucible which allowed evaluation of higher fusion and evaporation temperatures. The high-temperature ABF fusion dissolution method was evaluated using geological reference materials: USGS QLO-1a Quartz Latite, USGS SDC-1 Mica Schist, and NIST 278 Obsidian Rock. The optimized dissolution method involved a 10 min fusion at 540 °C, a 5 min reflux in 8 M HNO 3 , an evaporation at 300 °C and final dilution into 45 mL of 2% (v/v) HNO3. The final solution was filtered after heating at 105 °C using a hotblock. This dissolution method was simple, requiring only a hotplate or hotblock, filtered samples were available for ICP-MS analysis or radiochemical separation within 150 min, and was found to have high (>90%) recovery for many isotopes of interest in nuclear forensics applications. U and Pu in the dissolved material was separated using TEVA and UTEVA extraction chromatography columns, a process which resulted in >90% recovery. An irradiated U tracer was spiked into the material prior to dissolution and analyzed for recovery of major fission products and 239Np. The monitored radionuclides had recoveries of greater than 90%, except for the volatile radioiodine isotopes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclide inventory validation: radiochemical assay data quality and modeling challenges in benchmark models development

Oak Ridge National Laboratory is conducting radiochemical assay experiments, using high-precision analytical protocols validated with a comprehensive quality assurance plan, to expand the nuclide inventory validation basis for high burnup spent nuclear fuel. Preliminary measurement data for key actinides and fission products in two pressurized water reactor spent fuel samples are being used to investigate the impact of measurement data uncertainty on the sample burnup estimation. These measurement data are also being used to examine the impact of assumptions applied when developing best-estimate computational models to simulate fuel irradiation history. The simulations are being performed using depletion capabilities in the SCALE code system. Comparison of calculated and measured nuclide concentrations shows good agreement for the considered nuclides. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NA-22 Write for Consortium Efforts

We are asked to look into the improvements for the measurement of Pu of a variety of material types (MT): MT41 (Pu-242, 20 – 60% enriched), MT42 (Pu-242 > 60% enrichment), and MT-82 (Np-237). Many of these are legacy items that were packaged years ago (Fig 1&2), and when the items are re-packaged for long-term storage, they must be re-measured using either NDA (nondestructive analysis methods or radiochemical methods. It is of interest to improve the NDA and radiochemistry to reduce the un-certainty in the measurements, as in the case of larger items (250 g to 2 kg items) the uncertainty in measurements makes it difficult to certify the mass of the material down to the 0.5 g accountability requirement per DOE orders by only doing NDA measurement. It would be of interest to look into methods to improve the detection of these materials, which would not only benefit the weapon manufacturing community, but also has the ability to significantly improve the non-proliferation community.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring Hydroxylammonium, Nitrate, and Nitrite Concentration with Raman Spectroscopy for 238 Pu Supply Program

Optical spectroscopy has great potential to improve the timeliness of important analytical measurements for the 238 Pu Supply Program by enabling real-time analysis of process solutions within radiochemical hot cells. Hydroxylammonium (H 3 NOH + ]), nitrate (NO 3 - ), and nitrite (NO 2 - ) are three important molecular species present in multiple aqueous streams throughout the program’s flow sheet. The concentration of each species normally goes uncharacterized during processing. However, rapid quantification may benefit the program because uncertainties in kinetic redox expressions describing hydroxylammonium (HA) and nitrite reactions with Np and Pu leads to uncertainty in process model predictions for solvent extraction runs. HA concentration is normally quantified using ion chromatography, a technique that requires diluted grab samples taken out of the hot cell and analyzed off-line. Here we evaluate Raman spectroscopy for determining the concentration of H 3 NOH + , NO 3 - , and NO 2 - in benchtop tests to determine limits of detection. We also consider the possibility of using Raman spectroscopy in both glove box and hot cell environments for rapid analysis and pinpoint additional development opportunities needed to make this application successful.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistical analysis of the performance and long-term stability of unquenched LSC standards ( 3 H, 14 C) used for radiochemical measurements

Multiple sets of toluene-based unquenched standards, procured over the last 3 decades, were analyzed to determine their stability over time. A statistical analysis was performed to provide insight into the variability for tSIE and counting efficiency measurements of 3 H and 14 C isotopes. Our data suggests that standards remain viable even 30 years after the manufacturer’s recommended expiration date. Overall, these standards have shown no statistically significant sign of performance degradation. We have proven through statistical analysis that these standards can provide comparable performance over time well past their manufactured expiration date.

LSC standards↗

Chemometrics and Experimental Design for the Quantification of Nitrate Salts in Nitric Acid: Near-Infrared Spectroscopy Absorption Analysis

Implementing remote, real-time spectroscopic monitoring of radiochemical processing streams in hot cell environments requires efficiency and simplicity. The success of optical spectroscopy for the quantification of species in chemical systems highly depends on representative training sets and suitable validation sets. Selecting a training set (i.e., calibration standards) to build multivariate regression models is both time- and resource-consuming using standard one-factor-at-a-time approaches. This study describes the use of experimental design to generate spectral training sets and a validation set for the quantification of sodium nitrate (0–1 M) and nitric acid (0.1–10 M) using the near-infrared water band centered at 1440 nm. Partial least squares regression models were built from training sets generated by both D- and I-optimal experimental designs and a one-factor-at-a-time approach. The prediction performance of each model was evaluated by comparing the bias and standard error of prediction for statistical significance. D- and I-optimal designs reduced the number of samples required to build regression models compared with one-factor-at-a-time while also improving performance. Models must be confirmed against a validation sample set when minimizing the number of samples in the training set. The D-optimal design performed the best when considering both performance and efficiency by improving predictive capability and reducing number of samples in the training set by 64% compared with the one-factor-at-a-time approach. The experimental design approach objectively selects calibration and validation spectral data sets based on statistical criterion to optimize performance and minimize resources.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay↗

Cell G 7606A Mockup Measurement Analysis Methods and Results

The production of research isotopes at the Radiochemical Engineering Development Center (REDC) invariably leads to the accumulation of radioactive waste. Storage of this waste onsite at ORNL serves as an interim solution prior to shipment to long term storage facilities, however onsite capacity is limited. Proper characterization of the activity of waste products is essential for determining the appropriate waste stream and, ultimately, mitigating the cost of disposal. This is typically done via gamma spectrometry and use of the In-Situ Object Counting System (ISOCS), a software package from Mirion that serves as an accepted community standard. However, variability in the contents, density, and activity distribution in waste containers can introduce large errors in ISOCS quantification. A measurement campaign using a mockup of the proposed setup in Cell G seeks to quantify the magnitude and source of these systematic errors. Analysis of this data will guide the creation of ISOCS geometry templates and measurement methods designed to minimize overall uncertainty in reported activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Irradiation of Sintered Mo Disks with Presence of Organic Impurities in He Gas Flow

Argonne National Laboratory (Argonne) is assisting NorthStar Medical Technologies in the development of a domestic supply of 99 Mo. Specifically, the present study focuses on the production of 99 Mo-feed solution used by the RadioGenix™ 99m Tc generator. During the target-irradiation phase of production, impurities can potentially be introduced into the feed, and can lead to disturbance of ligand- 99m Tc complexation chemistry and contamination of the final radiopharmaceutical that directly interacts with the patient. To address this issue, Argonne performed irradiations and chemical processing to identify whether the potential contamination of He flow with hydrocarbon oil during irradiation affects the radiochemical purity of the final K 2 MoO 4 (K 2 TcO 4 ) in 5M KOH solution. To mimic the conditions of real irradiation at NorthStar, Argonne used its electron linear accelerator and Van de Graaff facilities, heated the target and oil source to >800°C, and controlled oxygen in the presence of He during irradiation. Following irradiation, scanning electron microscopy (SEM) and carbon analysis (CA) were used to detect carbon contamination on the solid targets. The radiochemical purity of the dissolved targets was studied via thin-layer paper chromatography (TLC). As a result of these experiments, small regions of the surface of some irradiated disks were found to be high in carbon, but the total carbon content was still negligible in comparison to the reference sample, which had experienced no irradiation or contact with oil. The summarized results from the SEM, CA, and TLC tests lead to the conclusion that even an excess of oil and heating during irradiation do not affect the radiochemical purity of the final product.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis and Recommendation of Tritium Gas Continuous Air Monitor Alarm Setpoints for the RPL Stack Exhaust

The Radiochemical Processing Laboratory (RPL) tritium continuous air monitor (CAM) is used for near real-time detection of tritium gas (i.e., elemental tritium [HT] and tritiated water vapor [HTO]) in the stack exhaust. The CAM interfaces with software developed by the Pacific Northwest National Laboratory (PNNL)—called the “PNNL OS3700 Tritium Monitoring Software”—that provides near real-time estimates of tritium gas air concentrations and integrated daily activities that are calculated from measured CAM counts. The OS3700 software implements alarm setpoints to alert the facility of larger tritium gas releases that if allowed to persist, could begin to challenge permitted emission and established dose constraints. This report performs a detailed review of historical and current tritium alarm setpoints used at RPL, including discussion of the technical basis used in their development, analysis of alarm frequencies using measured historical data, and performs a detailed dose assessment using more realistic release scenarios and meteorology. Based on the results, the tritium air concentration and integrated daily tritium activity alarm setpoints will remain 2.0 × 10 -5 µCi/ml and 25 Ci/day, respectively. These setpoints achieve the right operational balance in identifying larger releases from planned tritium work at RPL, without being overly conservative so as to cause nuisance alarming. Furthermore, implied doses associated with these setpoints are well below defined and regulatory limits.

325RPL↗

Analysis and Recommendation of Alpha-Beta Continuous Air Monitor Alarm Setpoints for the RPL Stack Exhaust

The Radiochemical Processing Laboratory (RPL) alpha-beta continuous air monitor (CAM) is used for real-time detection of “artificial” alpha-beta particulates from the stack exhaust. The CAM interfaces with software developed by the Pacific Northwest National Laboratory—called the “PNNL OS3300 Alpha-Beta Monitoring Software”—that provides real-time estimates of alpha-beta air concentrations and integrated activities that are calculated from measured CAM counts. The OS3300 software has alarm setpoints that can be used to provide an early indication of larger releases, that if allowed to persist, could approach defined dose limits. This report performs a detailed review of historical and current alarm setpoints used at RPL, including discussion of the technical basis used in their development, analysis of alarm frequencies using measured historical data, and performs a detailed dose assessment using more realistic release scenarios, meteorology, and adjustment factors used in estimating released stack activity. Based on the results, the alpha and beta air concentration alarm setpoints will remain 1.77 × 10 -8 µCi/ml and 3.47 × 10 -8 µCi/ml, respectively; and the alpha and beta integrated activity alarm setpoints will remain 70.22 µCi and 137.63 µCi, respectively. These setpoints achieve the right operational balance in identifying larger releases from planned radiological work at RPL, without being overly conservative so as to cause nuisance alarming. Furthermore, implied doses associated with these setpoints are below defined and regulatory limits.

325RPL↗

Monitoring the Caustic Dissolution of Aluminum Alloy in a Radiochemical Hot Cell Using Raman Spectroscopy

Chemical processing of highly radioactive materials commonly takes place in heavily shielded hot cells. The remote, real-time monitoring of chemical processing streams via optical spectroscopic techniques in hot cells may be particularly useful. Here in this paper, we describe the implementation of Raman spectroscopy and chemometric analysis to monitor the dissolution of aluminum-clad targets containing irradiated aluminum–neptunium oxide cermet pellets in caustic solutions in a hot cell environment. Partial least squares regression analysis was used to generate calibration models to quantify the concentration of dissolved aluminum, nitrate, and hydroxide in solutions within the radiochemical hot cell. This work explored a systematic approach to optimize a matrix of calibration standards using a D-optimal experimental design. The Design of Experiments-based regression model, in comparison to more traditional analytical approaches, was found to be the more practical method for building calibration models, with fewer samples, to obtain informative analytical data from Raman spectra.

36 MATERIALS SCIENCE↗

Results of The Solvent Hold Tank Disposal Sample

Multiple samples from the Solvent Hold Tank (SHT) at the Modular Caustic-Side Solvent Extraction Unit (MCU) were delivered to SRNL and composited for comprehensive analysis in support of a disposal pathway for this organic liquid. A suite of radiochemical and nonradiochemical analyses show that the solvent composition is as expected with respect to the solvent components. The radiochemical analyses confirm the assumption that very few radioactive species are associated with the solvent (other than cesium) and those that have measurable values are typically a few tens of pCi/mL in activity concentration. The solvent has a total activity of ≤1.99E- 08 Ci/g, or ≤6.27E-05 Ci/gal. The cesium in the solvent has an activity of ≤1.76E-08 Ci/g, or ≤5.55E-05 Ci/gal. For the non-radiochemical analyses, the results are as anticipated. The solvent shows no or minimal propensity to take up Resource Conservation Recovery Act (RCRA) metals, except for mercury, likely due to uptake of methyl-mercury compounds known to be in the feed stream.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗