LANDSAT 4 investigation of thematic mapper and multispectral scanner applications

Six different band combinations of TM data were selected for evaluation by four experienced photointerpreters who were asked to rank the band combinations according to the ease with which the category of image feature designated for each set of combinations could be distinguished. There were four sets of combinations selected for each category of image feature. Scenes of Oklahoma City, Oklahoma and of the Sacramento Valley, California area were enlarged to 1:250,000 and 2 cm circular chips were cut from each print. A nonparametric rank order test was carried out on the data to determine if the interpreters found no difference among the band combinations in ranking for the designated categories. Kendall's coefficient of concordance (W) was calculated and the significance of the W value was determined by a chi-square test. A table summarizes the results of the evaluation and shows the rank order of band combinations indicated as valid by rejection of the null hypothesis.

Lauer, D. T.↗

Fire testing in the Boeing 707 cabin section

The goal of a FIREMEN funded contract is the definition of a laboratory test method ranking airplane interior materials by probable performance in post-crash and in-flight fires. A major task is the relation of laboratory results to full scale data. A large test facility for testing materials to the thermal threat of fuel fed and interior fires was developed with quartz lamps and a propane burner in a twenty foot fuselage section. A method was developed to analyze full scale data for the apparent heat, smoke and toxicant release rates of the material tested.

Tustin, E. A.↗

Fire toxicology program. JSC methodology

Toxicological testing of spacecraft materials was initiated in 1965. Toxicological evaluations of the pyrolysis/combustion products of candidate spacecraft materials were performed using a modified 142 liter Bethlehem Chamber equipped with a Linberg Model 55031 furnace external to the chamber. In all of the assessments, lethality was chosen as the endpoint. A new pyrolysis/combustion chamber was developed for toxicological testing and ranking of both spacecraft and aircraft materials. The pyrolysis/combustion chamber permits the use of both behavior and physiological measurements as indicators of incapacitation. Methods were developed which employ high resolution gas chromatography/mass spectrometry to generate chamber atmospheric profiles which indicate the reproductibility of pyrolysate concentrations. The atmospheric volatile profiles in combination with CO, CO2, and O2 analysis indicates that small chamber equipped with an internal furnace will give reproducible results.

Schneider, H.↗

Analysis of the Einstein sample of early-type galaxies

The EINSTEIN galaxy catalog contains x-ray data for 148 early-type (E and SO) galaxies. A detailed analysis of the global properties of this sample are studied. By comparing the x-ray properties with other tracers of the ISM, as well as with observables related to the stellar dynamics and populations of the sample, we expect to determine more clearly the physical relationships that determine the evolution of early-type galaxies. Previous studies with smaller samples have explored the relationships between x-ray luminosity (L(sub x)) and luminosities in other bands. Using our larger sample and the statistical techniques of survival analysis, a number of these earlier analyses were repeated. For our full sample, a strong statistical correlation is found between L(sub X) and L(sub B) (the probability that the null hypothesis is upheld is P less than 10(exp -4) from a variety of rank correlation tests. Regressions with several algorithms yield consistent results.

Eskridge, Paul B.↗

Ignition Resistance of Polymeric Materials to Particle Impact in High-Pressure Oxygen

Particle impact ignition has been the primary cause of numerous fires in oxygen systems. This ignition phenomenon is known to occur where particles are present in high-velocity gas, and where impact occurs on a flammable material. The particle impact ignition behavior of many metals has been widely studied, but the particle impact ignition behavior of polymeric materials is relatively unknown. Particle impact ignition in polymeric materials is a concern as these materials are commonly used in component seat and seal applications, where high-velocity particle impacts can occur. This study evaluates several polymeric materials and compares the minimum temperature required for ignition (threshold temperature) of these materials: Kel-F 81 (CTFE), Teflon (PTFE), PEEK, Vespel SP-21, and Nylon 6/6. The materials were configured as targets in the White Sands Test Facility high-velocity particle impact test system. Gaseous oxygen was flowed at 4000 psi and sonic velocity, and the targets were impacted with 2000-micron aluminum 2017 particles. This paper discusses the results of these tests and ranks the materials according to their threshold temperatures at these conditions.

Forsyth, Elliot T.↗

The Ocean Colour Climate Change Initiative: III. A Round-Robin Comparison on In-Water Bio-Optical Algorithms

Satellite-derived remote-sensing reflectance (Rrs) can be used for mapping biogeochemically relevant variables, such as the chlorophyll concentration and the Inherent Optical Properties (IOPs) of the water, at global scale for use in climate-change studies. Prior to generating such products, suitable algorithms have to be selected that are appropriate for the purpose. Algorithm selection needs to account for both qualitative and quantitative requirements. In this paper we develop an objective methodology designed to rank the quantitative performance of a suite of bio-optical models. The objective classification is applied using the NASA bio-Optical Marine Algorithm Dataset (NOMAD). Using in situ Rrs as input to the models, the performance of eleven semianalytical models, as well as five empirical chlorophyll algorithms and an empirical diffuse attenuation coefficient algorithm, is ranked for spectrally-resolved IOPs, chlorophyll concentration and the diffuse attenuation coefficient at 489 nm. The sensitivity of the objective classification and the uncertainty in the ranking are tested using a Monte-Carlo approach (bootstrapping). Results indicate that the performance of the semi-analytical models varies depending on the product and wavelength of interest. For chlorophyll retrieval, empirical algorithms perform better than semi-analytical models, in general. The performance of these empirical models reflects either their immunity to scale errors or instrument noise in Rrs data, or simply that the data used for model parameterisation were not independent of NOMAD. Nonetheless, uncertainty in the classification suggests that the performance of some semi-analytical algorithms at retrieving chlorophyll is comparable with the empirical algorithms. For phytoplankton absorption at 443 nm, some semi-analytical models also perform with similar accuracy to an empirical model. We discuss the potential biases, limitations and uncertainty in the approach, as well as additional qualitative considerations for algorithm selection for climate-change studies. Our classification has the potential to be routinely implemented, such that the performance of emerging algorithms can be compared with existing algorithms as they become available. In the long-term, such an approach will further aid algorithm development for ocean-colour studies.

Phytoplankton↗

The oxygen sensitivity/compatibility ranking of several materials by different test methods

Eleven materials were evaluated for oxygen compatibility using the following test methods: heat of combustion (ASTM D 2015), liquid oxygen impact (ASTM D 2512), pneumatic impact (ASTM G 74), gaseous mechanical impact (ASTM G 86), autogenous ignition temperature by pressurized differential scanning calorimeter, and the determination of the 50 percent reaction level in liquid oxygen using silicon carbide as a reaction enhancer. The eleven materials evaluated were: Teflon TFE, Vespel SP-21, Krytox 240AC, Viton PLV5010B, Fluorel E2160, Kel F 81, Fluorogold, Fluorogreen E-600, Rulon A, Garlock 8573, nylon 6/6.

Lockhart, Billy J.↗

Creep-fatigue behavior of NiCoCrAlY coated PWA 1480 superalloy single crystals

Single crystal specimens of a Ni base superalloy, PWA 1480, with a low pressure plasma sprayed NiCoCrAlY coating were tested in various 0.1 Hz fatigue and creep fatigue cycles both at 1015 and 1050 C. Creep fatigue tests of the cp, pc, and cc types were conducted with various constant total strain ranges employing creep dwells at various constant stresses. Considerable cyclic softening occurred as was evidenced particularly by rapidly increasing creep rates in the creep fatigue tests. The cycle time in the creep fatigue tests typically decreased by more than 80 percent at 0.5 N sub f. Though cyclic life did correlate with delta epsilon sub in a better correlation existed with sub f for both the fatigue and creep fatigue tests, and poor correlations were observed with either sigma sub max or the average cycle time. A model containing both delta sigma and delta sigma (sub in), N sub f = alpha delta sigma (sub in) beta delta sigma gamma, with best fit values of sigma for each cycle type, but the same values of beta and gamam, was found to provide good correlations. Life lines were not greatly different among the cycle types, differing only by a factor of about three. The cp cycle life line was lowest for both test temperatures, however among the other three cycle types there was no consistent ranking. For all test types failure occurred predominately by multiple internal cracking originating at pores. The strong correlation of life with delta sigma may reflect a significant crack growth period in the life of the specimens.

Miner, R. V.↗

Creep-fatigue behavior of NiCoCrAlY coated PWA 1480 superalloy single crystals

Single crystal specimens of a Ni base superalloy, PWA 1480, with a low pressure plasma sprayed NiCoCrAlY coating were tested in various 0.1 Hz fatigue and creep fatigue cycles both at 1015 and 1050 C. Creep fatigue tests of the cp, pc, and cc types were conducted with various constant total strain ranges employing creep dwells at various constant stresses. Considerable cyclic softening occurred as was evidenced particularly by rapidly increasing creep rates in the creep fatigue tests. The cycle time in the creep fatigue tests typically decreased by more than 80 percent at 0.5 N sub f. Though cyclic life did correlate with delta epsilon sub in a better correlation existed with sub f for both the fatigue and creep fatigue tests, and poor correlations were observed with either sigma sub max or the average cycle time. A model containing both delta sigma and delta sigma (sub in), N sub f = alpha delta sigma (sub in) beta delta sigma gamma, with best fit values of sigma for each cycle type, but the same values of beta and gamam, was found to provide good correlations. Life lines were not greatly different among the cycle types, differing only by a factor of about three. The cp cycle life line was lowest for both test temperatures, however among the other three cycle types there was no consistent ranking. For all test types failure occurred predominately by multiple internal cracking originating at pores. The strong correlation of life with delta sigma may reflect a significant crack growth period in the life of the specimens.

Miner, R. V.↗

Lifetimes of fiber composites under sustained tensile loading

Results are presented for a study intended to summarize lifetime data on several fiber/epoxy composite materials subjected to sustained uniaxial tensile loading, to report preliminary results of an accelerated test method for predicting the life of simple composites, and to describe related work in progress on pressure vessels and other filament-wound structures. The lifetime performance of the tested composites was compared by plotting the percent of ultimate strength (applied fiber stress normalized with respect to fiber failure stress in a composite) versus lifetime. In terms of performance in long-term tensile applications, the tested composites are ranked in the following order: graphite/epoxy, Be wire/epoxy, Aramid/epoxy, and S-glass/epoxy. The accelerated test using temperature and stress to simulate the passage of time proves to be encouraging, at least in the case of the Aramid/epoxy composite. The potential of a statistical analysis based on Weibull distribution analyses or a power law relationship is demonstrated.

Chiao, T. T.↗

Impact sensitivity of materials in contact with liquid and gaseous oxygen at high pressure

As a result of the Apollo 13 incident, increased emphasis is being placed on materials compatibility in a high pressure GOX environment. It is known that in addition to impact sensitivity of materials, approximately adiabatic compression conditions can contrive to induce materials reactivity. Test runs at high pressure using the ABMA tester indicate the following: (1) The materials used in the tests showed an inverse relationship between thickness and impact sensitivity. (2) Several materials tested exhibited greater impact sensitivity in GOX than in LOX. (3) The impact sensitivity of the materials tested in GOX, at the pressures tested, showed enhanced impact sensitivity with higher pressure. (4) The rank ordering of the materials tested in LOX up to 1000 psia is the same as the rank ordering resulting from tests in LOX at 14.7 psia.

Schwinghamer, R. J.↗

Ignition of metals and alloys in gaseous oxygen by frictional heating

The ignition of metals and alloys have been investigated by rotating the end of a hollow cylinder against an identical stationary cylinder on a common axis (frictional heating) in gaseous oxygen. A ranking criterion that measures the resistance of metals and alloys to ignition is discussed. It consists of the power per unit area required for ignition conveniently expressed as the product of contact pressure P and average linear velocity ALV. Data are presented that demonstrate that materials that are high in nickel and copper require greater P-ALV products for ignition (more resistant to ignition) than materials that are high in iron. Aluminum and titanium alloys are shown to require the lowest P-ALV products for ignition. The effects of varying surface velocity, contact pressure, coefficient of friction, and oxygen pressure on P-ALV products required for ignition are discussed. The results indicate that P-ALV product required for ignition increases as surface velocity increases, as contact pressure decreases, and as the coefficient of friction decreases. Increasing oxygen pressure will cause the P-ALV product required for ignition to decrease at low pressures and increase at high pressures. In some cases, the relative ranking of materials based on P-ALV products will also change as conditions are varied. The data presented in this paper are from a development program to determine the merits of using such a dynamic test method for ranking materials for oxygen service. The results to date have indicated that more testing is required before this method can be made into a standard test. The data presented do show some of the major parameters affecting the ignition of materials when exposed to frictional heating. The repeatability of the data at any set of conditions have not been thoroughly investigated.

Benz, F. J.↗

Medical impact analysis for the Space Station

In this study, Space Station medical care priorities were determined by a medical impact analysis of two analog populations, U.S. Army and U.S. Navy personnel. Diseases and injuries in the International Classification of Disease, 9th Revision, Clinical Modification (ICD-9-CM) were ranked, using a Medical Impact Score (MIS) combining modified incidence rate and a function of disease outcome. The validity of the analysis method was tested by measuring rank order correlation between the two analog populations. Despite virtually identical age and sex distributions, Army and Navy incidence rates differed significantly for half of the ICD-9-CM categories, p less than 0.05. Disability rates differed for 76 percent, p less than 0.05. Nevertheless, Army and Navy MIS rank orders for categories and sections were not significantly different, p less than 0.001. In critical ways, the Space Station will be a safer environment than earth. Cardiac events, musculoskeletal injuries, affective psychoses, and renal calculi were among the highest scoring categories.

Nelson, Brent D.↗

The influence of various test plans on mission reliability

Methods have been developed for the evaluation of cost effective vibroacoustic test plans for Shuttle Spacelab payloads. The shock and vibration environments of components have been statistically represented, and statistical decision theory has been used to evaluate the cost effectiveness of five basic test plans with structural test options for two of the plans. Component, subassembly, and payload testing have been performed for each plan along with calculations of optimum test levels and expected costs. The tests have been ranked according to both minimizing expected project costs and vibroacoustic reliability. It was found that optimum costs may vary up to $6 million with the lowest plan eliminating component testing and maintaining flight vibration reliability via subassembly tests at high acoustic levels.

Stahle, C. V.↗

MIL-C-38999 electrical connector applicability tests for on-orbit EVA satellite servicing

MIL-C-38999 electrical connectors were tested for their applicability to the on-orbit EVA satellite servicing environment. The investigation provided a methodical approach to the evaluation of the human-machine interface of these connectors. The physical characteristics of thirty-five MIL-C-38999 connectors were tested in two simulated space environments, the NASA Johnson Space Center Weightless Environment Training Facility and an evacuated glovebox which incorporated the Extravehicular Maneuvering Unit series 3000 gloves. Physical characteristics of the connectors were documented, including operating torque and work profiles. STS crewmembers tested a select group of connectors in two WETF test and subjectively ranked the G&H PMM Wing-Tab connectors as most applicable to the on-orbit servicing environment. WETF performance times indicated that the G&H PMM Wing-Tab connector had the fastest operating time. The evacuated glovebox participants ranked the G&H 64600 Wing-Tab and the G&H PMM Wing-Tab connectors as those most applicable to the on-orbit servicing environment. During the evacuated glovebox tests, the G&H 64600 Wing-Tab connector had the fastest operating time.

Griffin, Thomas J.↗

3.6 Arc Jet Test Facilities

Among all the ground test facilities that have been developed over the past 7 decades for testing TPS, arc jet ranks as the most flight relevant and extensively used test facility in the history of TPS development in the US. Arc Jet facilities played, and continue to play, a critical role not only in the early screening and selection of TPS materials, but more importantly, in the flight vehicle integrated development and in the flight qualification.

Ethiraj Venkatapathy↗

The performance and efficiency of four motor/controller/battery systems for the simpler electric vehicles

A test and analysis program performed on four complete propulsion systems for an urban electric vehicle (EV) is described and results given. A dc series motor and a permanent magnet (PM) motor were tested, each powered by an EV battery pack and controlled by (1) a series/parallel voltage-switching (V-switch) system; and (2) a system using a pulse width modulation, 400 Hz transistorized chopper. Dynamometer tests were first performed, followed by eV performance predictions and data correlating road tests. During dynamometer tests using chopper control; current, voltage, and power were measured on both the battery and motor sides of the chopper, using three types of instrumentation. Conventional dc instruments provided adequate accuracy for eV power and energy measurements, when used on the battery side of the controller. When using the chopper controller, the addition of a small choke inductor improved system efficiency in the lower duty cycle range (some 8% increase at 50% duty cycle) with both types of motors. Overall system efficiency rankings during road tests were: (1) series motor with V-switch; (2) PM motor with V-switch; (3) series motor with chopper; and (4) PM motor with chopper. Chopper control of the eV was smoother and required less driver skill than V-switch control.

Shipps, P. R.↗