26 records · Page 2

Demonstration of fully coupled simplified extended station black-out accident simulation with RELAP-7

The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The RELAP-7 code develop-ment effort started in October of 2011 and by the end of the second development year, a number of physical components with simplified two phase flow capability have been de-veloped to support the simplified boiling water reactor (BWR) extended station blackout (SBO) analyses. The demonstration case includes the major components for the primary system of a BWR, as well as the safety system components for the safety relief valve (SRV), the reactor core isolation cooling (RCIC) system, and the wet well. Three scenar-ios for the SBO simulations have been considered. Since RELAP-7 is not a severe acci-dent analysis code, the simulation stops when fuel clad temperature reaches damage point. Scenario I represents an extreme station blackout accident without any external cooling and cooling water injection. The system pressure is controlled by automatically releasing steam through SRVs. Scenario II includes the RCIC system but without SRV. The RCIC system is fully coupled with the reactor primary system and all the major components are dynamically simulated. The third scenario includes both the RCIC system and the SRV to provide a more realistic simulation. This paper will describe the major models and dis-cuss the results for the three scenarios. The RELAP-7 simulations for the three simplified SBO scenarios show the importance of dynamically simulating the SRVs, the RCIC sys-tem, and the wet well system to the reactor safety during extended SBO accidents.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: Reactor Core Isolation Cooling 1998-2022

This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 28 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar years 1998–2022 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. Statistically significant decreasing trends were identified in both the RCIC system start-only unreliability and 8-hour mission unreliability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: Reactor Core Isolation Cooling 1998-2024

This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 28 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar years 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period and yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the RCIC results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Severe Accident Research Directions after Fukushima

The accidents at the Fukushima Daiichi nuclear power station in March of 2011 renewed interest globally in the nature, causes, and health and economic consequences of severe accidents involving core damage and containment impairment. As a result of these accidents, research has been conducted into the modeling and phenomenological understanding of the accidents at Fukushima and the response and effectiveness of mitigating measures such as emergency water injection, primary system depressurization and containment venting actions. An important example of this is the jointly conducted OECD-NEA organized Benchmark of the Fukushima Accidents (BSAF project) where accident reconstruction analyses using computer codes such as MELCOR and MAAP are ongoing. Even prior to the Fukushima accidents, the Sandia/NRC sponsored State of Art Reactor Consequence Analyses (SOARCA) foreshadowed the accidents in Japan where long-term and short-term station blackout accidents in boiling water reactors with Mark-1 containment were analyzed showing striking similarities to the accidents at Fukushima. These analyses also highlighted important differences in our prior understanding, in particular the importance of suppression pool thermal stratification and the extraordinary operation of the Fukushima Unit-2 reactor core isolation cooling (RCIC) system, prompting addition research into both of these areas. Additionally, the focus of the world's major computer codes on modeling the Fukushima accidents in the BSAF effort, led to several 'Crosswalk' comparisons between code predictions, highlighting subtle but important modeling differences between the codes and identifying areas where modeling improvements can be made. Collectively, these research areas are aimed at improving our understanding of severe accident progression and real-world response of safety related systems and components, and should lead to improved accident response and mitigation capabilities in the future. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TRACE and TRAC-BF1 benchmark against Leibstadt plant data during the event inadvertent opening of relief valves

In framework of introducing TRACE code to transient analyses system codes for Leibstadt Power Plant (KKL), a conversion process of existing TRAC-BF1 model to TRACE has been started within KKL. In the first step, TRACE thermal-hydraulic model for KKL has been developed based on existing TRAC-BF1 model. In order to assess the code models a simulation of plant transient event is required. In this matter simulations of inadvertent opening of 8 relief valves event have been performed. The event occurs at KKL during normal operation, and it started when 8 relief valves open resulting in depressurization of the Reactor Pressure Vessel (RPV). The reactor was shutdown safely by SCRAM at low level. The high pressure core spray (HPCS) and the reactor core isolation cooling (RCIC) have been started manually in order to compensate the level drop. The remaining water in the feedwater (FW) lines flashes due to saturation conditions originated from RPV depressurization and refills the reactor downcomer. The plant boundary conditions have been used in the simulations and the FW flow rate has been adjusted for better prediction. The simulations reproduce the plant data with good agreement. It can be concluded that the TRAC-BF1 existing model has been used successfully to develop the TRACE model and the results of the calculations have shown good agreement with plant recorded data. Beside the modeling assessment, the TRACE and TRAC-BF1 capabilities to reproduce plant physical behavior during the transient have shown satisfactory results. The first step of developing KKL model for TRACE has been successfully achieved and this model is further developed in order to simulate more complex plant behavior such as Turbine Trip. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance evaluation of a Terry GS-2 steam impulse turbine with air-water mixtures

Terry steam turbines are widely used in various industries because of their robust design. Within the nuclear power generation industry, they are used in the Reactor Core Isolation Cooling System to remove decay heat during reactor isolation events. During the Fukushima Daiichi nuclear power station disaster in Japan in 2011, the Reactor Core Isolation Cooling System and associated Terry turbine operated for over 70 hours in Unit 2; this runtime is well beyond the expected operating duration. Theories suggest the turbine was subjected to a two-phase inlet flow, which could degrade the turbine performance. In this work, an experimental test rig was constructed to test a full-scale Terry model GS-2 steam turbine under two-phase air/water flows. Steady-state efficiency and torque performance maps of the turbine were developed over a range of turbine inlet pressures (1.38–4.83 bar or 20–70 psia), air mass fractions (0.05–1.0) and rotational speeds up to 4000 RPM. Furthermore, turbine performance followed expected trends with torque varying linearly and efficiency varying quadratically with rotational speed. In addition, high-speed images of the two-phase flow entering the turbine were also analyzed to understand how changes in inlet pressure and air mass fraction affect the flow regime and homogenization. The present tests with air–water two-phase mixtures are an important step towards providing an understanding of the full-scale Terry turbine’s behavior and performance curves under two-phase conditions. The results of this work will be combined with air/water and steam/water data gathered using a small-scale Terry ZS-1 steam turbine in order to understand the scaling relationship between large and small size Terry turbines and fluid pairs. The combined data set will enable further development of analytical models over a wide range of conditions and may be used to provide technical justification for expanded use of the Terry turbines in nuclear power plant safety systems and other systems.

42 ENGINEERING↗

Developing A Fully Implicit Compressible Flow Valve Model in RELAP-7 and Its Application in Short Term BWR Station Black-Out Analyses

This paper presents a set of dynamical models for SRV simulation and their implementation in the RELAP-7 code, which is a new reactor system analysis code being developed at INL. RELAP-7 is based on the MOOSE (the Multi-Physics Object-Oriented Simulation Environment) framework. The compressible flow SRV model covers three different sets of models: fully closed case, subsonic case, and choking case. The RELAP-7 is a fully implicit code and the preconditioned Jacobian-free Newton-Krylov (JFNK) method is used to solve the discretized nonlinear problem. The JFNK method generally needs a good preconditioning scheme to be effective and efficient. There are different ways to precondition the JFNK method. In RELAP-7, two main options are used to obtain the preconditioning matrix: (1) FDP (Finite Difference Preconditioning) option which uses the default finite differencing method provided in the PETSc package. PETSc is the numerical solver software developed by Argonne National Laboratory and used by MOOSE as the numerical solution engine; (2) SMP (Single Matrix Preconditioning) option which requires code developers to provide approximate analytical Jacobian inputs for the important diagonal and off-diagonal terms. Due to the strong discontinuity in the residual vector space when the compressible flow valve model switches from one set of model to another, FDP option cannot guarantee convergence. Instead, accurate analytical Jacobain terms are provided for the compressible flow valve model. With the SMP option selected, the compressible flow valve model can be solved efficiently under different cases. The developed compressible flow valve model has been used for SRV component simulation in several simplified BWR SBO (Station Black-Out) simulations with RELAP-7. This paper only presents cases for short-term SBO in which all the safety systems fail to start and function properly when SBO occurs. Consequently, only the SRVs automatically open and close periodically to control the primary system pressure and discharge the high temperature and high pressure steam into the suppression pool. Although simplified, this case is quite similar to what happened in Fukushima Daiichi Unit 1. Unit 1 had no RCIC system, while the isolation condenser system was believed to be non-functioning, or only available for a very short period of time during the accident. Therefore, the Unit 1 reactor core reached a fuel failure temperature only a few hours into the accident. Two short-term SBO cases will be compared: one with single SRV discharge line which represents all the SRV lines and another case with multi-group SRVs which represent each group of SRV line with different setting points.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Terry Turbopump Expanded Operating Band Modeling and Full-Scale Test Development Efforts in FY19 (Progress Report)

The Terry Turbine Expanded Operating Band Project is currently conducting testing at Texas A&M University, and the resulting data has been incorporated into MELCOR models of the Terry turbines used in nuclear power plants. These improved models have produced improvements in the Fukushima Daiichi Unit 2 simulations while providing new insights into the behavior of the plant. The development of future experimental test efforts is ongoing. Development of and refinements to the plans for full-scale steam and steam-water turbine ingestion testing has been performed. These full-scale steam-based tests will complement the testing occurring at Texas A&M University, and will resolve the remaining questions regarding scale or working fluid. Planning work has also begun for future testing intended to explore the uncontrolled RCIC self-regulation theorized to have occurred in Fukushima Daiichi Unit 2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗