Semi-two-dimensional transient modeling of decay heat removal to an external reactor cavity cooling system for a gFHR with effects of heat generation pattern
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Safe operation of a sodium cooled fast reactor (SFR) can be significantly aided by heat removal systems that do not rely on active power, but function using passive means. Passive heat removal from such reactors can employ systems that extract heat directly from sodium coolant by utilizing heat exchangers submerged in the coolant and natural circulation of a metal fluid sodium (or sodium potassium eutectic) to heat exchangers (generally air cooled) externally located. These types of systems are generally called Direct Reactor Auxiliary Cooling Systems (DRACS). Another type of passive heat removal system particularly suitable for pool-type SFRs relies on indirect extraction of heat by utilizing air flow in an annular region surrounding the reactor guard vessel which discharges the heat via the chimney effects to the atmosphere. These systems are generally called Reactor Vessel Auxiliary Cooling Systems (RVACS).
The High Temperature Test Facility (HTTF) at Oregon State University is an integral system test facility to simulate postulated reactor transients of prismatic high-temperature gas-cooled reactors(HTGRs). A series of test campaigns was launched, providing abundant test data that could be used to benchmark reactor system analysis codes like the System Analysis Module (SAM). In this study, a SAM model of the facility is developed based on the two-dimensional (2D) ring model approach. All components including the ceramic matrix, graphite heaters, helium coolant channels, core barrel, upcomer, pressure vessel, and reactor cavity cooling system are modeled as concentric cylindrical rings. The model is used to simulate one of the benchmark problems-Pressurized Conduction Cooldown (PCC)-within the scope of the Organisation for Economic Co-operation and Development Nuclear Energy Agency International HTTF Benchmark. The simulations consist of two parts. In the first part, operating and boundary conditions as well as thermophysical properties of materials are specified for the benchmark problem. In this work, results from the first part will be used in code-to-code comparison. In the second part, the SAM model is used to simulate Test PG-27, which is the first PCC test carried out in the HTTF, with only two of the ten heater banks activated. The results in the second part are used for code-to-data comparison. Because the helium coolant flow rate is not measured in this facility, it is estimated using the input power and inlet/outlet coolant temperatures. Additionally, radial heat flow in the ceramic blocks is complicated by hundreds of cylindrical coolant channels and heater rods embedded in them. As such, it is necessary to deduce an effective thermal conductivity for the ceramic to analyze the core thermal behavior. SAM predictions of the helium coolant and ceramic temperatures are compared with test data measured in three equivalent sectors. Overall, the SAM results agree reasonably well with test data within the variation of data among the three sectors, which demonstrates SAM's capability in capturing transient effects in HTGR using the simplified 2D ring model.
The invention does away with the necessity of moving parts such as a check valve in a nuclear reactor cooling system. Instead, a jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A main flow exists for a reactor coolant. A point of withdrawal is provided for a secondary flow. A TEMP, responsive to the heat from said coolant in the secondary flow path, automatically pumps said withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature where the heat is no longer a problem. At this lower temperature, the TEMP/jet pump combination ceases its circulation boosting operation. When the nuclear reactor is restarted and the coolant again exceeds the lower temperature setting, the TEMP/jet pump automatically resumes operation. The TEMP/jet pump combination is thus automatic, self-regulating and provides an emergency pumping system free of moving parts.
In order to accurately predict the behavior of the Reactor Core Isolation Cooling System (RCIC) in the context of the FLEX strategies under the extended station black-out accident (SBO), we present a mechanistic model of the RCIC in this work. The control volume formulation of angular momentum conservation is employed to model the Terry turbine in the RCIC system. The two-phase nozzle flow model developed in the previous work is utilized to simulate the convergent-divergent nozzles in the Terry turbine. A nozzle flow table is generated to cover the operation range of the RCIC during beyond design basis accidents (BDBAs). The mechanistic RCIC turbine-pump model and the nozzle flow table are incorporated in a TRACE BWR model. Simulations of short-term and long-term SBO transients are performed to demonstrate dynamic RCIC responses. A system analysis code with the proposed mechanistic model of the RCIC system will have a better prediction of system safety response during SBO accidents. With the addition of such more realistic models, the system code will be capable of providing expanded understanding of safety margin, which can help help to form the technical basis for the successful implementation of the FLEX and SAMG measures under Extended Loss of AC Power (ELAP) conditions for BWR or PWR reactor designs.
About 2.5 kilometers from the village of Jaslovske Bohunice in the Trnava District in western Slovakia at the Bohunice V1 nuclear power plant, Westinghouse and VUJE are working on the dismantling of two VVER-440 units. The consortium was awarded this contract in October 2017 from Jadrova a vyradovacia spolocnost (JAVYS) and has begun onsite work to dismantle the reactor coolant systems of both units that operated at the plant. The Bohunice V1 plant is composed of two V-230 type VVER 440 units (440 MWe each). The first unit ceased operation on December 31, 2006, and the second on December 31, 2008, after 28 years of operation. The project strategy relies on the early release of some plant areas to allow the erection of new facilities to enable a fast and safe dismantling. These up-front activities play a crucial role within the whole project. Since schedule and ALARA are two key elements to be considered, it has been decided to separate the dry cutting activities from the ones occurring underwater. Two Wet Cutting Workshops will allow the segmentation and packaging of the high activity components. To take advantage of the large space available in the turbine building, a Dry Cutting Workshop has been built for segmenting the twelve steam generators of both units. Two more Dry Cutting Workshops (one per unit) have been installed in the reactor building for the fragmentation of the remaining large components and auxiliary systems components. This paper describes all current preparatory works as well as the on-going segmentation and packaging activities. Interesting lessons learned are also provided. (authors)
This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 28 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar years 1998–2022 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. Statistically significant decreasing trends were identified in both the RCIC system start-only unreliability and 8-hour mission unreliability.
This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 31 U.S. commercial boiling water reactors. Demand, run hours, and failure data from calendar years 1998 through 2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the RCIC results.
This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 28 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar years 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period and yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the RCIC results.
This study reviews previous experimental facilities and test programs relevant to water-cooled reactor system design and analysis to meet regulatory compliances. This study aims to find the best solution for designing the required experiments, obtaining necessary test data, and verifying the developed computer code/models to support the new reactor design and development while minimizing cost and time while leveraging experiences from previous facilities to minimize. Nuclear reactor licensing requires supportive design, analysis, and experimental results to ensure the safety of the full-scale prototype reactor in regular operation, as well as during postulated accident scenarios. These reactor design analyses are generally performed using system codes and other associated simulation tools that require assessment, verification and validation using an appropriate experimental dataset. Experimental facilities used for reactor system safety analysis and system code assessments are categorized into integral effects test (IET) and separate effects test (SET) facilities. Further, these IET and SET experiments and studies use geometrically scaled systems to reproduce the prototype system behavior at a reasonable cost, albeit with some scaling-related distortions. The design challenge of these model facilities is to identify and minimize scaling distortions while reproducing the most important operational phenomena in steady-state operation and in postulated accident scenarios. Lessons learned from previous experimental facilities, models, and correlations can support the development of new multipurpose, scaled, hybrid, integrated, and modular experimental facilities for advanced light water-cooled small modular reactors (SMRs). Successful operation of these facilities can significantly reduce upfront reactor development and demonstration costs and time to deployment.
The following report provides a technical review of various reactor vessel cooling system (VCS) concepts under consideration for decay heat removal (DHR) in non-light water advanced reactor designs. This review focuses on ex-vessel designs, including the Reactor Cavity Cooling System (RCCS), the Reactor Vessel Auxiliary Cooling System (RVACS), and hybrid iterations, using both air and water cooling to achieve their heat removal function. Based on a literature review of publicly available sources published between 1979 and 2021, a technical summary is presented detailing existing and planned VCS design options, their applicability to specific reactor type, and review of authored research and development studies. Following an assessment of the availability of data and modeling tools, an evaluation was performed analyzing their likely performance during normal, degraded, and accident conditions, including reliability, stability, and longevity. With renewed consideration of air-based DHR systems by some US vendors, there is a need to fully understand the complexities inherent to natural circulation systems, and more importantly, how they may influence safety-related heat removal functions and system performance. For DHR systems that rely on air-based mode of cooling, this entails quantification of the impacts of low flow conditions during start-up, relative elevations of inlet and outlet ducts for below-grade installations, effects of the use of multiple parallel chimneys for redundancy, and impact of weather conditions at the plant site. For systems relying on water-based mode cooling, reliance on limited coolant inventory in an event of pipe break or extended duration accident scenarios, sensitivities related to stability of boiling flow and heat transfer conditions, and quantification of full-scale structural vibrations on balance of plant structures are among the complicating factors.
Griffin is a Multiphysics Object-Oriented Simulation Environment based reactor multiphysics analysis application jointly developed by Idaho National Laboratory and Argonne National Laboratory. Griffin includes a variety of deterministic radiation transport solvers for fixed source, k-eigenvalue, adjoint, and subcritical multiplication, as well as transient solvers for point-kinetics, improved quasi-static, and spatial dynamics. A code assessment performed in FY-20 identified two significant issues with the transport solvers in Griffin: first, the primary heterogeneous SN (discrete ordinates) transport solver based on continuous finite element methods required significant mesh refinement and higher memory usage compared to solvers based on the method of characteristic for equivalent accuracy. Second, the homogeneous PN (spherical harmonics expansion) transport solver did not adequately support polynomial refinement, which is a feature usually required for problems with spatial homogenization and pronounced streaming, typical in fast or gas-cooled reactor systems. To address the first issue, the development effort focused on the more promising discontinuous finite element method (DFEM)-based SN transport solver in Griffin. The addition of an asynchronous parallel transport sweeper and coarse mesh finite difference (CMFD) acceleration have rendered a superior heterogeneous SN transport capability for multiphysics problems that requires far less computing resources in terms of both CPU time and memory usage. This is demonstrated with typical thermal- and fast-spectrum reactor benchmark problems, including 2D Transient Reactor Test, 3D Advanced Burner Test Reactor (ABTR), and 2D and 3D Empire microreactor. For the second issue, the development effort focused on a new transport solver based on the hybrid finite element PN method (HFEM-PN), equivalent to the variational nodal method, as well as a new diffusion solver based on HFEM-Diffusion. This solver is intended for homogenized domains with multiphysics coupling (i.e., supports mesh displacement, seamless temperature feedback, etc.). Initial calculations with the HFEM-Diffusion implementation show very good parallel efficiency for the residual evaluations with the 2D ABTR benchmark. A future development effort will be centered on further improvements to the CMFD, HFEM-PN, and DFEM diffusion solvers to ensure Griffin meets performance and software quality assurance requirements for advanced reactor design and analysis.
This article describes the radiation facilities and associated sample preparation, management, and analysis equipment currently in place at the Dalton Cumbrian Facility, a facility which opened in 2011 to support the UK’s nuclear industry. Examples of measurements performed using these facilities are presented to illustrate their versatility and the breadth of research they make possible. Results are presented from research which furthers our understanding of radiation damage to polymeric materials, radiolytic yield of gaseous products in situations relevant to nuclear materials, radiation chemistry in light water reactor cooling systems, material chemistry relevant to immobilization of nuclear waste, and radiation-induced corrosion of fuel cladding elements. Applications of radiation chemistry relevant to health care are also described. Research concerning the mechanisms of radioprotection by dietary carotenoids is reported. An ongoing open-labware project to develop a suite of modular sample handling components suited to radiation research is described, as is the development of a new neutron source able to provide directional beams of neutrons.
MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to include non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR technologies under Strategy 2 of the NRC's near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enhancements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform fluoride-salt-cooled high-temperature reactor (FHR) safety evaluations. The generic plant model is based on publicly-available FHR design information. For plant aspects (e.g., reactor building leak rate and details of the cover-gas system) that are not described in the FHR references, the analysts made assumptions needed to construct a MELCOR full-plant model. The FHR model uses a TRi-structural ISOtropic (TRISO)-particle fuel pebble-bed reactor with a primary system rejecting heat to two coiled tube air heat ex changers. Three passive direct reactor auxiliary cooling systems provide heat removal to supplement or replace the emergency secondary system heat removal during accident conditions. Surrounding the reactor vessel is a low volume reactor cavity that insulates the reactor with fire bricks and thick concrete walls. A refractory reactor liner system provides water cooling to reduce the concrete wall temperatures. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing reactivity control, the primary system decay heat removal and also a piping leak of the line to the coolant drain tank.
Submitting a poster for the LDRD poster session. Please see the attachment for details.
Nuclear systems are promising candidates for delivering resilient heat and power for future energy security and independence. Traditionally, nuclear plants have been used for baseload electricity production and cogeneration of heat has seen relatively limited application utilizing typically only small portion of a reactor's thermal output. This paradigm may shift due to the increasing penetration of intermittent renewables and need for resource flexibility, various decarbonization efforts aimed at both electricity and heat demands, along with the perspective of small modular nuclear reactor applications, which can be sized based on local industrial needs. Here, this study provides a comprehensive guide for the nuclear and industrial sectors, emphasizing controllability in the combined heat and power configuration options for high temperature gas-cooled reactor and process steam supply. It investigates the integration of thermal energy storage to improve nuclear energy's responsiveness to varying industrial demands. The study emphasizes placing thermal energy storage between the nuclear primary loop and steam cycle to achieve greater efficiency and flexibility in power and heat output, surpassing traditional combined heat and power systems and avoiding efficiency losses seen in other thermal energy storage integration approaches.
Not provided.
Abstract not provided.