Search NASA⌕ Search

SEARCH · Search NASA

Results for “RELAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effect of GPS Manipulation to Traditional and Next Generation Relay Protection

This project’s objective is to test the effect of GPS timing variations on relay protection algorithms to determine vulnerabilities and the associated hazards to the electric grid. This will focus on differential protection which utilizes peer to peer communication between substations to determine if the current is not equivalent. This requires the use of GPS to sync the two substations and can be vulnerable to GPS manipulation. However, the effects of GPS manipulation are not a commonly known risk. Therefore, this LDRD will address the risks of GPS manipulation for such a widely implemented technology. For differential protection a GPS resilient architecture was implemented and tested for differential protective relays through a direct serial fiber connection between the two relays. This allows for one relay to be the master and provide synchronization outside of timestamp for differential protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

Adaptive Protective Relay Settings – A Vision to the Future

Adaptive relaying utilizes the continuously changing status of the power system as the basis for online adjustment of the power system relay settings. Fundamentally they are protection schemes that adjust settings and/or logic of operations based on the prevailing conditions of the system. These adjustments can include, but are not limited to, the logging of data for post-mortem analysis, communication throughout the system, as well as changing relay parameters. Adaptive relaying considers the fact that the status of a power system can change. These include system configuration changes, load effect, cold load pickup, end-of-line protection, transformer protection, and automatic reclosing. In this research, the author focus on the need for a secure, selective, and reliable system for adaptive overcurrent protection in T&D and Distributed Energy Systems. Various types of adaptive methods are presented and explained along with some pros and cons of each.

Mukherjee, Srijib↗

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays↗

Estimation Based Protection Relay-Application to Distribution System with High DER Penetration

This document presents the application of the estimation based protection (EBP) relay on the distribution system. The study aims to provide a solution to the IEEE 1547-2018 protection issues. The EBP relay has been developed for transmission and generation systems and is equally applied to distribution systems. The performance of the EBP relay is evaluated for distribution system with high penetration of distributed energy resources (DERs).

14 SOLAR ENERGY↗

Efficient 15 N hyperpolarization of [ 15 N 3 ]metronidazole antibiotic via spin-relayed pulsed SABRE-SHEATH

Signal Amplification by Reversible Exchange in SHield Enables Alignment Transfer to Heteronuclei (SABRE-SHEATH) is an NMR hyperpolarization technique that relies of the simultaneous exchange of parahydrogen and a to-be-hyperpolarized molecule on the metal center of a polarization-transfer catalyst in a microtesla magnetic field. Until recently, this method has been understood to perform hyperpolarization by establishing level anti-crossings between the nuclear spins of the parahydrogen derived hydrides (acting as a source of hyperpolarization) and those of the substrate. Recently, the application of highly non-intuitive pulse sequences (comprising pulses of microtesla DC fields) was predicted to hyperpolarize nuclear spins more efficiently than the canonical (static-field) SABRE-SHEATH approach. Here we show that by employing a basic “on-off” pulse sequence of rectangular microtesla pulses, it is possible to improve the hyperpolarization efficiency for SABRE-SHEATH of [ 15 N 3 ]metronidazole, an FDA-approved antibiotic (in non-enriched and non-hyperpolarized form) and potential hypoxia sensing molecule. Specifically, we demonstrate that 15N polarization of 18.5 % can be obtained in 80 s of parahydrogen bubbling parahydrogen through a solution containing 20 mM [ 15 N 3 ]metronidazole. In practice, (1.32 ± 0.14)-fold improvements in P 15N was obtained with the pulsed method described here compared to static field technique variant. These results show that pulsed SABRE-SHEATH was successfully applied to 15 N-labeled biologically relevant molecule. Moreover, we also demonstrate that although the pulsed SABRE-SHEATH sequence was designed for polarization transfer from parahydrogen derived hydrides to the metronidazole’s 15 N catalyst-binding site, all three 15 N sites of [ 15 N 3 ]metronidazole attained the hyperpolarized state. This spin-relayed polarization transfer becomes possible due to the 15 N relay network established by their spin-spin J-couplings. The feasibility of the spin-relayed polarization transfer is demonstrated here for the first time for pulsed SABRE-SHEATH (as opposed to the static-field SABRE-SHEATH reported previously) and it paves the way to broad applicability of the technique.

Hyperpolarization↗

Pendent Relay Enhances H 2 O 2 Selectivity during Dioxygen Reduction Mediated by Bipyridine-Based Co–N 2 O 2 Complexes

Generally, cobalt–N 2 O 2 complexes show selectivity for hydrogen peroxide during electrochemical dioxygen (O 2 ) reduction. We recently reported a Co(III)–N 2 O 2 complex with a 2,2'-bipyridine-based ligand backbone which showed alternative selectivity: H 2 O was observed as the primary reduction product from O 2 (71 ± 5%) with decamethylferrocene as a chemical reductant and acetic acid as a proton donor in methanol solution. We hypothesized that the key selectivity difference in this case arises in part from increased favorability of protonation at the distal O position of the key intermediate Co(III)–hydroperoxide species. To interrogate this hypothesis, in this study we have prepared a new Co(III) compound that contains pendent –OMe groups poised to direct protonation toward the proximal O atom of this hydroperoxo intermediate. Mechanistic studies in acetonitrile (MeCN) solution reveal two regimes are possible in the catalytic response, dependent on added acid strength and the presence of the pendent proton donor relay. In the presence of stronger acids, the activity of the complex containing pendent relays becomes O 2 dependent, implying a shift to Co(III)–superoxide protonation as the rate-determining step. Interestingly, the inclusion of the relay results in primarily H 2 O 2 production in MeCN, despite minimal difference between the standard reduction potentials of the three complexes tested. EPR spectroscopic studies indicate the formation of Co(III)–superoxide species in the presence of exogenous base, with greater O 2 reactivity observed in the presence of the pendent –OMe groups.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proton Relay for the Rate Enhancement of Electrochemical Hydrogen Reactions at Heterogeneous Interfaces

Proton transfer is critically important to many electrocatalytic reactions, and directed proton delivery could open new avenues for the design of electrocatalysts. However, although this approach has been successful in molecular electrocatalysis, proton transfer has not received the same attention in heterogeneous electrocatalyst design. Here, in this work, we report that a metal oxide proton relay can be built within heterogeneous electrocatalyst architectures and improves the kinetics of electrochemical hydrogen evolution and oxidation reactions. The volcano-type relationship between activity enhancement and pK a of amine additives confirms this improvement; we observe maximum rate enhancement when the pK a of a proton relay matches the pH of the electrolyte solution. Density-functional-theory-based reactivity studies reveal a decreased proton transfer energy barrier with a metal oxide proton relay. These findings demonstrate the possibility of controlling the proton delivery and enhancing the reaction kinetics by tuning the chemical properties and structures at heterogeneous interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ByzSec — A Multi-layered Byzantine Resilient Architecture for Bulk Power System Protective Relays

Reliability, selectivity, and sensitivity are the fundamental attributes of any protection system, acting as the main drivers in the selection of schemes, and equipment. In high-voltage systems, microprocessor-based relays represent the industry’s preferred solution, providing engineers with a vast array of benefits. However, they remain vulnerable to cybersecurity events that may compromise their functionality. To help mitigate against potential cybersecurity risks, this paper presents a fault-tolerant, Byzantine Resilient (BR) architecture that significantly increases the cybersecurity attributes of a protection system while minimizing the amount of performance impacts and integration overheads introduced. The solution relies on an array of independent relays that utilize robust consensus methods (based on Spire [1], [2]) to ensure correct system behavior is achieved even when a relay has been compromised. Furthermore, the solution has been complemented with a custom-built Situational Awareness engine that can be used to detect and identify potential threats. The implemented solution has been developed in consultation with three hardware vendors and has been tested to comply with the performance requirements of a 345kV differential protection scheme (87T). The results indicate that the proposed architecture is a comprehensive solution that: supports the strict correctness and performance requirements of the bulk power grid while providing a cost-effective alternative that offers a seamless, long-term solution.

byzantine security, Fault Tolerant Application Sof↗

System Identification of a DC-DC Buck Converter Based on Two-Channel Relay Method

This work presents a system identification approach based on a two-channel relay applied to a DC-DC buck converter operating in closed-loop with a PI controller to regulate its output voltage. The implemented two-relay method allows system identification while the system is running online. Moreover, the algorithm works in a closed-loop configuration while introducing a minimal perturbation in the converter's operation. The presented algorithm was used to identify the frequency response of the converter with no-prior knowledge about the system structure. Furthermore, the identified transfer function parameters has a good agreement with the mathematical model of the converter. Simulation results of the comparison between the switching model, mathematical model and the identified model are provided to validate the theoretical analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achievable Rate and Energy Efficiency Analysis of Multiuser Relay-Aided Massive MIMO Downlink

In this article, the achievable sum rate and the energy efficiency (EE) are investigated for a multiuser relay-aided massive multiple-input–multiple-output (MIMO) downlink. Low-resolution digital-to-analog converters (DACs) are equipped at both the base station (BS) and the relay station (RS), and the amplify-and-forward protocol is adopted at the RS. Under the Rician fading channel, closed-form approximate expressions for the achievable sum rate are derived with perfect and imperfect channel state information. Furthermore, a more general power law is extracted to save transmit power without reducing the achievable sum rate, and a local optimal power allocation scheme is proposed to improve the channel capacity of active users. Then, the tradeoff between the achievable sum rate and the EE is discussed. The numerical results show that, due to the quantization noise, the transmit power has a limited increase in the achievable rate. In addition, it is more valuable to improve the DAC quantization bit at the RS when the number of BS antennas is larger than that of RS antennas. In addition, under strong line-of-sight channels or high pilot transmit power conditions, the channel estimation accuracy is higher, and the best tradeoff between the achievable sum rate and the EE can be obtained when the DAC quantization bit is 4.

25 ENERGY STORAGE↗

Energy‐aware relay positioning in flying networks

Summary The ability to move and hover has made rotary‐wing unmanned aerial vehicles (UAVs) suitable platforms to act as flying communications relays (FCRs), aiming at providing on‐demand, temporary wireless connectivity when there is no network infrastructure available or a need to reinforce the capacity of existing networks. However, since UAVs rely on their on‐board batteries, which can be drained quickly, they typically need to land frequently for recharging or replacing them, limiting their endurance and the flying network availability. The problem is exacerbated when a single FCR UAV is used. The FCR UAV energy is used for two main tasks: Communications and propulsion. The literature has been focused on optimizing both the flying network performance and energy efficiency from the communications point of view, overlooking the energy spent for the UAV propulsion. Yet, the energy spent for communications is typically negligible when compared with the energy spent for the UAV propulsion. In this article, we propose energy‐aware relay positioning (EREP), an algorithm for positioning the FCR taking into account the energy spent for the UAV propulsion. Building upon the conclusion that hovering is not the most energy‐efficient state, EREP defines the trajectory and speed that minimize the energy spent by the FCR UAV on propulsion, without compromising in practice the quality of service offered by the flying network. The EREP algorithm is evaluated using simulations. The obtained results show gains up to 26% in the FCR UAV endurance for negligible throughput and delay degradation.

Rodrigues, Hugo↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900-MHz LTE network↗

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Harmonized Automatic Relay Mitigation of Nefarious Intentional Events (HARMONIE) - Special Protection Scheme (SPS)

The harmonized automatic relay mitigation of nefarious intentional events (HARMONIE) special protection scheme (SPS) was developed to provide adaptive, cyber-physical response to unpredictable disturbances in the electric grid. The HARMONIE-SPS methodology includes a machine learning classification framework that analyzes real time cyber-physical data and determines if the system is in normal conditions, cyber disturbance, physical disturbance, or cyber-physical disturbance. This classification then informs response, if needed and/or suitable, and included cyber-physical corrective actions. Beyond standard power system mitigations, a few novel approaches were developed that included a consensus algorithm-based relay voting scheme, an automated power system triggering condition and corrective action pairing algorithm, and a cyber traffic routing optimization algorithm. Both the classification and response techniques were tested within a newly integrated emulation environment composed of a real-time digital simulator (RTDS) and SCEPTRE™. This report details the HARMONIE-SPS methodology, highlighting both the classification and response techniques, and the subsequent testing results from the emulation environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications: Preprint

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900 MHz LTE network↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗