Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDUAL GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Extreme Ultraviolet and Beyond Extreme Ultraviolet Lithography Using Amorphous Zeolitic Imidazolate Resists Deposited by Atomic/Molecular Layer Deposition

Amorphous zinc-imidazolate (aZnMIm) resists show potential to meet the demands for next-generation high-numerical aperture (high-NA) metal-containing extreme ultraviolet (EUV) resist materials, given their ease of deposition by atomic/molecular layer deposition (ALD/MLD) at thicknesses of 20 nm and below. Here, this study demonstrates that aZnMIm thin films, previously identified as high-resolution electron beam resists, can also function as negative-tone EUV photoresists. Water development achieves high sensitivity (5 mJ/cm 2 ) but leaves significant residue, while acetic acid development results in poor contrast. A hybrid approach─water followed by acetic acid─enables residue-free development with a sensitivity of 181 mJ/cm 2 . Dry development using 1,1,1,5,5,5-hexafluoroacetylacetone (hfacH) is also possible but shows lower sensitivity (375 mJ/cm 2 ) compared to wet development methods. EUV photoelectron spectroscopy (PES), reflectometry/EUV absorption, total electron yield (TEY), residual gas analysis (RGA), and time-of-flight secondary ion mass spectrometry (TOF-SIMS) were used to investigate the effects of EUV irradiation on aZnMIm resists. Reflectometry experiments reveal an aZnMIm EUV absorption coefficient of 6.2 μm –1 , while PES and TEY analyses show that, compared to poly(4-hydroxystyrene) (PHS), a polymer-based reference resist, aZnMIm emits more primary and secondary electrons but generates fewer slow electrons relative to its primary electron emission; its total electron yield is similar to that of poly(methyl methacrylate) (PMMA) resists. When exposed to EUV, aZnMIm predominantly outgasses H 2 , as determined by RGA. TOF-SIMS measurements demonstrate that high-dose EUV exposure only partially fragments the 2-methylimidazole (2MIm) organic linkers, unlike high-dose electron beam exposure, which is known to completely degrade them. Additionally, aZnMIm resists show promise for potential beyond EUV lithography (BEUVL) due to the presence of Zn, which provides higher sensitivity at a wavelength of 6.7 nm compared to other metal ions, such as Sn, that are currently used in the best-performing EUV metal–organic resists. TEY measurements demonstrate that aZnMIm emits nearly twice as many electrons as PHS at 6.7 nm. The BEUV TEY of aZnMIm also surpasses that of PMMA, poly(pentafluorostyrene), and poly(4-iodostyrene), with the latter two being known for their high EUV TEYs. This work provides insight into zeolitic imidazolate framework (ZIF)-based EUV and BEUV resists and highlights their potential for both wet and dry development.

lithography↗

Bismuth-oxo Clusters for Next Generation Extreme Ultraviolet Light Photolithography

Photolithography is the primary technique used for the patterning of semiconducting materials for chip manufacturing; however, as requisite pattern dimensions and feature sizes continue to decrease, state-of-the-art lithographic methods now require the use of 13.5 nm extreme ultraviolet (EUV) light. The shift toward these higher energy wavelengths of light has resulted in a need for new single component materials, with high EUV absorption cross sections and high etch resistance. Herein, we report the exploration of Bi 9 O 7 (hfac) 13 as the first bismuth oxo cluster based EUV photoresist. It was determined this material has an exceptional EUV linear absorption coefficient (24 μm –1 ), nearly an order of magnitude larger than commercially available chemically amplified resists (CARs) (∼5 μm –1 ). Additionally, the resist was determined to be highly sensitive to EUV exposure and displayed a dose-to-gel of 10 mJ/cm 2 , undergoing ligand decomposition during exposure and cross-linking during the postexposure bake, which was supported by FTIR and residual gas analysis. In conclusion, this class of bismuth-oxo cluster resists can lead to the development of more efficient, effective and safe EUV resist materials required for next-generation photolithography.

MacKenzie, Harvey K. [Univ. of Victoria, BC (Canad↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION↗

Measurement of the free neutron lifetime in a magneto-gravitational trap with in situ detection

Here, in this study, we publish three years of data from the UCNτ experiment performed at the Los Alamos Ultracold Neutron Facility at the Los Alamos Neutron Science Center. These data are in addition to our previously published data. Our goals in this paper are to better understand and quantify systematic uncertainties and to improve the lifetime statistical precision. We previously reported a value from our 2017–2018 data for the neutron lifetime of 877.75 ± 0.28 (statistical) +0.22–0.16 (systematic) s. We have collected an additional three years of data reported here for the first time. When all the data from UCNτ are averaged for 2017, 2018, 2020, 2021, and 2022, we report an updated value for the lifetime of 877.83 ± 0.22 (statistical)+0.20–0.17 (systematic) s. We utilized improved monitor detectors, reduced our correction due to UCN upscattering on residual gas, and employed four different UCN detector geometries both to reduce the correction required for rate dependence and to explore potential contributions due to phase space evolution.

Cabibbo-Kobayashi-Maskawa matrix↗

Study of electron-induced chemical transformations in polymers

In extreme ultraviolet (EUV) photoresist exposure, the primary and secondary electrons drive chemistry rather than the EUV photons themselves. These electrons have a wide range of energies below approximately 80 eV, which are capable of complex network of reactions during exposure. To better understand the ability of electrons of different energies within the EUV primary and secondary electron range, we want to characterize and compare the chemistry induced in pure polymer films by direct exposure to electrons. Thin films of poly(tert-butyl methacrylate), poly(methyl methacrylate), and poly(4-hydroxystyrene) were exposed to a 20 to 80 eV electron beam. Outgassing during exposure was characterized in-situ using a quadrupole residual gas analyzer. The thickness changes were measured using ellipsometry and chemical bond structure data were collected using Fourier-transform infrared spectroscopy (FTIR) after exposure to compare different exposure conditions. Poly(4-hydroxystyrene) demonstrated stability during electron exposures. Exposures of the other two materials led to outgassing of protecting groups, the intensity of which decayed in time. Outgassing, FTIR, and thickness loss data exhibited approximately linear relationships to each other.

Mueller, Maximillian↗

Measurement of the background in the CMS muon detector in ${p}{p}$-collisions at $\sqrt{s} = 13$ TeV

The CMS detector, including its muon system, has been operating at the CERN LHC in increasingly challenging conditions for about 15 years. The muon detector was designed to provide excellent triggering and track reconstruction for muons produced in proton–proton collisons at an instantaneous luminosity ($\mathcal{L}$) of 1 x 10 34 cm –2 s –1 . During the Run 2 data-taking period (2015–2018), the LHC achieved an instantaneous luminosity of twice its design value, resulting in larger background rates and making the efficient detection of muons more difficult. While some backgrounds result from natural radioactivity, cosmic rays, and interactions of the circulating protons with residual gas in the beam pipe, the dominant source of background hits in the muon system arises from proton–proton interactions themselves. Charged hadrons leaving the calorimeters produce energy deposits in the muon chambers. In addition, high-energy particles interacting in the hadron calorimeter and forward shielding elements generate thermal neutrons, which leak out of the calorimeter and shielding structures, filling the CMS cavern. We describe the method used to measure the background rates in the various muon subsystems. These rates, in conjunction with simulations, can be used to estimate the expected backgrounds in the High-Luminosity LHC. This machine will run for at least 10 years starting in 2029 reaching an instantaneous luminosity of $\mathcal{L}$ = 5 x 10 34 cm –2 s –1 and increasing ultimately to $\mathcal{L}$ = 7.5 x 10 34 cm –2 s –1 . These background estimates have been a key ingredient for the planning and design of the muon detector upgrade.

Tytgat, M. (ORCID:0000000239902074)↗

Electrochemical Investigation of Moisture Byproducts in Molten Calcium Chloride

Residual water in molten CaCl 2 reacts to form different byproducts, such as HCl, which can impact the corrosivity of the salt and efficiency of electrochemical operations, such as electrolytic oxide reduction and electrorefining. The ability to detect and quantify these byproducts electrochemically can provide feedback on the efficacy of vacuum drying and other purification methods, as well as the impact of these byproducts on process operations. An electrochemical signal’s association with the production of H 2 is verified and characterized using cyclic voltammetry (CV) and residual gas analysis. CV estimated a 2-electron exchange process associated with H 2 production. CV detected trace quantities of an oxidized species containing hydrogen in the salt on the order of 10 ppm. Different salt handling methods were compared for their impact on the hydrogen electrochemical signal. It was found that 30 min of exposure of CaCl 2 in a beaker to low-humidity air (<20%) had minimal impact on the H 2 production signal.

Electrochemistry↗

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)↗

ULTRAFAST HIGH-VOLTAGE KICKER SYSTEM HARDWARE FOR ION CLEARING GAPS

Ionization scattering of electron beams with residual gas molecules causes ion trapping in electron rings, both in a collider and electron cooling system. These trapped ions may cause emittance growth, tune shift, halo formation, and coherent coupled bunch instabilities. To clear the ions and prevent them from accumulating turn after turn, the gaps in a temporal structure of the beam are used. Typi- cally, the gap in the bunch train has a length of a few per- cent of the ring circumference. In those regions, the extrac- tion electrodes with high pulsed voltages are introduced. In this paper, we present the design consideration and initial test results of the high-voltage pulsed kicker hardware that includes vacuum device and pulsed voltage driver, capable of achieving over 3 kV of deflecting voltage amplitude, rise and fall times of less than 10 ns, 100 ns flat-top duration at 1.4 MHz repetition rate.

Smirnov, A.↗

Selected advances in the accelerator design of the Future Circular Electron-Positron Collider (FCC-ee)

In autumn 2023, the FCC Feasibility Study underwent a crucial “mid-term review”. We describe some accelerator performance risks for the proposed future circular electron-positron collider, FCC-ee, identified for, and during, the mid-term review. For the collider rings, these are the collective effects when running on the Z resonance – especially resistive wall, beam-beam, and electron cloud –, the beam lifetime, dynamic aperture, alignment tolerances, and beam-based alignment. For the booster, the primary concern is the vacuum system, with regard to impedance and effects of the residual gas. For the injector, the layout and the linac repetition rate are primary considerations. We discuss the various issues and report the planned mitigations.

43 PARTICLE ACCELERATORS↗

On the Life Expectancy Ot High-power CW Magnetrons for Superconducting Accelrators

Modern CW or pulse Superconducting RF (SRF) accelerators require efficient RF sources controllable in phase and power with a reduced cost. Therefore, utilization of the high-power CW magnetrons as RF sources in SRF accelerator projects was proposed in a number of works, e.g., [1, 2]. But typically, the CW magnetrons are designed as RF sources for industrial heating, and the lifetime of the tubes is not the first priority as it is required for high-energy accelerators. The high-power industrial CW magnetrons use the cathodes made of pure tungsten. The emission properties of the tungsten cathodes are not deteriorated much by electron and ion bombardments, but the latter causes sputtering of the cathode in the magnetron crossed fields. The sputtered cathode material covers the magnetron interior. This leads to sparks and discharges that limit the life of the magnetrons. We considered an analysis of magnetron failure modes vs. output power [3]. We developed a model of ionization of the residual gas in the magnetrons interaction space and simulated the spattering of the cathode in 100 kW CW magnetrons to estimate the life expectancy. Basing on results we proposed ways to increase the CW magnetrons longevity for SRF accelerators.

43 PARTICLE ACCELERATORS↗

Proton Dynamics Scenarios in the Integrable Optics Test Accelerator (IOTA) at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab provides a versatile platform for studying the interplay of space-charge, impedance, and non-linear optics in high-intensity hadron beams within synchrotrons and storage rings. This report examines the parameters and dynamics of 2.5~MeV proton beam operations in two configurations of the bare IOTA lattice: one for demonstrating Non-linear Integrable Optics with the Danilov-Nagaitsev magnet, and the other for use with electron cooling. We offer order-of-magnitude estimates of the transverse emittance growth rate as a function of beam intensity, highlighting contributions from residual gas scattering, intra-beam scattering, and space-charge effects. Under nominal conditions, the beam lifetime is projected to be less than 7~minutes at low intensity with the current vacuum quality, and fewer than 100,000~turns at high intensity due to strong space-charge effects. The calculations presented here will guide strategies to mitigate emittance growth and inform future IOTA experiments.

43 PARTICLE ACCELERATORS↗

Thermal Compton Scattering of Electron Beams on Blackbody Photons: A Monte Carlo Event Generator for Multi-Turn Tracking at the Electron-Ion Collider

Compton scattering of ultra-relativistic electrons on thermal (blackbody) photons is typically a subdominant process in electron storage rings, but at sufficiently high electron energy and low residual gas pressure it can become competitive with beam-gas scattering and contribute to dis tributed losses and backgrounds. We present a self-contained Monte Carlo event generator for thermal Compton scattering designed for integration into multi-turn tracking workflows. The im plementation follows H. Burkhardt’s proposal method: trial scattering angles are sampled from the Thomson differential cross section and accepted/rejected using the Klein-Nishina to Thomson ratio, yielding the correct Compton spectrum while retaining simple absolute-rate normalization. Ther mal photon energies are sampled from the blackbody photon-number spectrum via an exact mixture representation.

43 PARTICLE ACCELERATORS↗

On the Life Expectance of High-power CW Magnetrons for SRF Accelerators

Modern CW or pulse Superconducting RF (SRF) accelerators require efficient RF sources controllable in phase and power with a reduced cost. Therefore, utilization of the high-power CW magnetrons as RF sources in SRF accelerator projects was proposed in a number of works, e.g., [1, 2]. But typically, the CW magnetrons are designed as RF sources for industrial heating, and the lifetime of the tubes is not the first priority as it is required for high-energy accelerators. The high-power industrial CW magnetrons use the cathodes made of pure tungsten. The emission properties of the tungsten cathodes are not deteriorated much by electron and ion bombardments, but the latter causes sputtering of the cathode in the magnetron crossed fields. The sputtered cathode material covers the magnetron interior. This leads to sparks and discharges that limit the life of the magnetrons. We considered an analysis of magnetron failure modes vs. output power [3]. We developed a model of ionization of the residual gas in the magnetrons interaction space and simulated the spattering of the cathode in 100 kW CW magnetrons to estimate the life expectancy. Basing on results we proposed ways to increase the CW magnetrons longevity for SRF accelerators.

43 PARTICLE ACCELERATORS↗

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)↗

Molecularly engineered Li compensation agent-integrated separator enabling regeneration of degraded LiFePO 4

Lithium replenishment separators (LRSs) integrating pre-lithiation agents can regenerate degraded lithium cathodes via facile reassembly with a fresh anode and the LRS. A persistent challenge is the formation of gas or solid residues during pre-lithiation. To address this, for the first time, we develop an LRS based on a molecularly engineered dilithium salt of tetrafluorohydroquinone, which compensates for lithium loss while generating decomposition products that dissolve in the electrolyte as a favorable additive, without forming gas or solid residues, thus offering a green route for lithium compensation. A pristine LiFePO 4 ‖graphite full cell with the LRS exhibits 9.3% higher overall capacity than a polypropylene separator (PPS) cell after 50 cycles at 0.5C, and the degraded LiFePO 4 ‖graphite full cell incorporating this LRS achieves a 44.9% higher capacity than the PPS-based cell after 200 cycles at 0.5C. Our LRS demonstrates strong potential for high-performance lithium-ion batteries and spent battery regeneration.

Tao, Fujun [Worcester Polytechnic Institute, MA (U↗

Techno Economic Analysis for Production of Renewable Natural Gas and Value-Added Chemicals from Forest Biomass Residues (CRADA Final Report)

West Biofuels - in collaboration with the University of California San Diego, the University of California Davis, the National Laboratory of the Rockies (NLR), the Colorado School of Mines’ Center for Hydrate Research, Placer County Air Pollution Control District, the Sierra Business Council, and the Southern California Gas Company (SoCalGas)-will demonstrate an innovative pathway to convert forest biomass to renewable gas (RG). The project, Production of Pipeline Grade Renewable Natural Gas and Value-Added Chemicals from Forest Biomass Residues, will utilize an existing pilot-scale gasification system and data and lessons learned from a lab-scale catalytic reactor design, develop, and demonstrate an integrated pilot-scale RG process with a scaled-up catalytic reactor and hydrate-based gas separation process. This robust and simple process uses a commercial proven gasifier, a commercially available catalyst that can tolerate gas contaminants, and a gas separation process that simplifies the downstream processing. Current testing has shown that the process can yield a large amount of methane rich renewable gas in addition to a mixture of propanol, ethanol and other higher alcohols and the relative amounts can be controlled by shifting the process conditions. This process is novel and groundbreaking because the product mixture of RG and valuable alcohols byproducts makes RG production economically feasible at $\$$12 per million British thermal units (MMBtu) or less using forest biomass from high hazard zones.

09 BIOMASS FUELS↗