Fusion burn-propagation simulations using the collisional and radiative particle-in-cell code TRIFORCE

The ability to accurately model burn propagation in inertial confinement fusion plasmas is crucial for advancing fusion energy research. This work presents enhancements to the triforce hybrid fluid-kinetic multiphysics code, focusing on its kinetic half, which employs the particle-in-cell (PIC) method with Monte Carlo collisions (MCC). We use a moment-preserving collision model that mitigates numerical noise, particularly in spherical geometries where particle weights vary significantly. Additionally, we refine the treatment of inverse bremsstrahlung to account for electron–ion collision frequency reductions in degenerate plasmas and incorporate a blackbody radiation source to enable realistic photon injection. These improvements enable the simulation of 1-dimensional (1D) spherical fusion burn propagation in deuterium–tritium plasmas. Benchmark comparisons with the hydra radiation-hydrodynamics code confirm that triforce accurately captures the dynamics of hot-spot expansion and burn propagation, demonstrating sensitivity to ignition thresholds consistent with theoretical models. Findings show the ignition cliff to be less steep in our work compared to radiation-hydrodynamic modeling. These results highlight the role of kinetic effects in fusion ignition physics and underscore the necessity of hybrid fluid-kinetic models for advancing predictive capabilities in high-energy-density plasma systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Quantum sensing using a qubit for the detection of ionizing radiation

Quantum sensing utilizes the inherent sensitivity of a quantum system to external stimuli. Our goal is to leverage this sensitivity to develop a quantum sensor designed for the detection of ionizing radiation. Here we report on the design, fabrication, and measurement of a new quantum device for hard x-ray and gamma-ray detection. Our quantum device is based on a superconducting quantum bit (qubit) with superconducting tunnel junctions as the core device elements. We describe our experimental investigation directed toward the detection metrics of energy resolution, dynamic range, and active area. In contrast to existing superconducting detectors, the active area per qubit may be much larger than the physical area of the tunnel junctions or the physical area of the qubit device, due to the sensitivity of quantum coherence to ionizing radiation deposition within a radius on the millimeter or centimeter scale. Furthermore, our experimental design enables an ionizing radiation source at room temperature to be detected by our quantum sensor at low temperature.

qubit

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Do We Know How to Model Reionization?

I compare the power spectra of the radiation fields from two recent sets of fully-coupled simulations that model cosmic reionization: “Cosmic Reionization On Computers” (CROC) and “Thesan”. While both simulations have similar power spectra of the radiation sources, the power spectra of the photoionization rate are significantly different at the same values of cosmic time or the same values of the mean neutral hydrogen fraction. However, the power spectra of the photoionization rate can be matched at large scales for the two simulations when the matching snapshots are allowed to vary independently. I.e., on large scales, the clustering of the radiation field in two simulations evolves similarly, but the exact timing of this evolution is different in different simulations and is not parameterized by an easily interpretable physical quantity like the mean neutral fraction or the mean free path. On small scales, large differences are present and remain partially unexplained. Both CROC and Thesan use the Variable Eddington Tensor approximation for modeling radiative transfer, but adopt different closure relations (optically thin OTVET versus M1). The role of this key difference is tested by using smaller simulations with a new cosmological simulation code that implements both closure relations in a controlled environment (the same hydro, cooling, and gravity solvers and the star formation recipe). In these controlled tests, both the M1 closure and the OTVET ansatz follow the expected behavior from a simple analytical approximation, demonstrating that the differences in the 2-point function of the radiation field induced by the choice of the Eddington tensor are not dominant.

79 ASTRONOMY AND ASTROPHYSICS

Radiation image reconstruction and uncertainty quantification using a Gaussian process prior

We propose a complete framework for Bayesian image reconstruction and uncertainty quantification based on a Gaussian process prior (GPP) to overcome limitations of maximum likelihood expectation maximization (ML-EM) image reconstruction algorithm. The prior distribution is constructed with a zero-mean Gaussian process (GP) with a choice of a covariance function, and a link function is used to map the Gaussian process to an image. Unlike many other maximum a posteriori approaches, our method offers highly interpretable hyperparamters that are selected automatically with the empirical Bayes method. Furthermore, the GP covariance function can be modified to incorporate a priori structural priors, enabling multi-modality imaging or contextual data fusion. Lastly, we illustrate that our approach lends itself to Bayesian uncertainty quantification techniques, such as the preconditioned Crank–Nicolson method and the Laplace approximation. The proposed framework is general and can be employed in most radiation image reconstruction problems, and we demonstrate it with simulated free-moving single detector radiation source imaging scenarios. We compare the reconstruction results from GPP and ML-EM, and show that the proposed method can significantly improve the image quality over ML-EM, all the while providing greater understanding of the source distribution via the uncertainty quantification capability. Furthermore, significant improvement of the image quality by incorporating a structural prior is illustrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Radiation Accidents and Malicious Events – Scenarios and Scope of the Work of ICRP Task Group 120

The International Commission on Radiological Protection (ICRP) Task Group 120 (TG120) is developing ICRP recommendations for radiological protection for a wide range of radiation accidents and malicious events, complementing those given in ICRP Publication 146 (2020) for large nuclear accidents. The scope includes accidents involving criticalities, operating faults, and fires and explosions in nuclear facilities, inadvertent damage to sealed radiation sources, as well as malicious events, such as sabotage of nuclear facilities or materials, use of radiological dispersal devices, the contamination of food and drinking water supplies, and the deployment of nuclear weapons. A template has been designed to collate relevant information on a wide range of case studies and hypothetical malicious scenarios to ensure that the recommendations developed are broadly applicable and comprehensive. For all scenarios, a graded approach to protection is being taken, accepting that specific guidance may be required for some distinctive aspects, for example, protection during times of armed conflict. This paper provides an overview of the scenarios and scope of the work of TG120, including some of the radiological and non-radiological impacts of radiation emergencies, along the response and recovery timeline.

ICRP

Small scale electron linear accelerators for industrial applications

Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications

43 PARTICLE ACCELERATORS

Special Nuclear Material Hold-up Measurement

Facilities that process special nuclear material (SNM) generally have a variety of equipment, shielding, and nearby radiation sources, which can pose challenges when performing nondestructive analysis (NDA) within the facility, as shown in Figure 1. In this figure, the left image features two individuals performing a holdup measurement of a large duct at a posting, utilizing a detector probe attached to a yardstick to reduce some aspect of the measurement uncertainty. Note that the distance to the holdup within the pipe from the posting cannot be accounted for. The right image similarly features several individuals guiding a holdup measurement of a ducting pipe several meters overhead, by attaching a detector probe to a long handle and lining that up with a posting on the outside of the pipe. SNM processing begets SNM holdup, and this difficulty with accurate NDA can result in unaccounted accumulation of SNM holdup within a process or area. Normal SNM processing operations can accumulate holdup within filters, pumps, pipes, ducts, other equipment, and facility support systems, as demonstrated by Figure 2. It is important for deactivation and decommissioning (D&D) gloveboxes and their ancillary equipment, material accountability, criticality safety, facility operations, waste management, radiation safety, and security to accurately characterize the location, composition, and quantity of this holdup to minimize these associated risks and potential diversion pathways. Current NDA techniques for assay of holdup are expensive, time consuming, and have high uncertainty.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

The LLNL rabbit: determination of trace element levels in polyethylene

Rabbit facilities are systems that pneumatically transport a sample carrier (known as a rabbit) to and from a radiation source. However, trace impurities in the polyethylene (PE) rabbit may interfere with measurements of short-lived isotopes. Activated impurities with short half-lives as 28 Al interfere with the fission product γ-ray, therefore the rabbit cannot be measured immediately. Neutron activation analysis was performed on various PE samples obtained from different manufacturers and the highest quality PE was used to fabricate a high-purity PE rabbit. Here, the impurities identified in the PE study were 27 Al, 48 Ca, 37 Cl, 50 Cr, 65 Cu, 127 I, 26 Mg, 55 Mn, and 30 Si.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

High-Throughput Uniformity and Defect Monitoring in Low-Temperature Electrolysis Porous Transport Layers Using X-Ray Radiography

Effective quality control (QC) for manufacturing proton exchange membrane water electrolysis (PEMWE) components is critical to enabling widespread adoption of the technology for hydrogen generation. This study investigates X-ray radiography as a novel, high-throughput, potentially in-line QC technique for detecting defects and assessing material property distributions in titanium-based porous transport layers (PTLs) which constitute a crucial component of low temperature PEMWE stacks. We obtain radiographs of a set of fifteen PTLs and model their absorbance of the broadband radiation as a second-order polynomial to account for the non-monoenergetic radiation source used in this study. The resulting model serves as a basis for predicting the areal density and porosity distributions of the PTLs. We find radiography successful in detecting multiple instances of defects, including holes/depressions, cracks, and excess material on the surface or in the pores of the material, demonstrating its potential as a robust in-line QC tool for PTL manufacturing.

08 HYDROGEN

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge

Generation of radioisotopes for medical applications using high-repetition, high-intensity lasers

We used the PW high-repetition laser facility VEGA-3 at Centro de Láseres Pulsados in Salamanca, with the goal of studying the generation of radioisotopes using laser-driven proton beams. Various types of targets have been irradiated, including in particular several targets containing boron to generate α-particles through the hydrogen–boron fusion reaction. We have successfully identified γ-ray lines from several radioisotopes created by irradiation using laser-generated α-particles or protons including 43 Sc, 44 Sc, 48 Sc, 7 Be, 11 C and 18 F. We show that radioisotope generation can be used as a diagnostic tool to evaluate α-particle generation in laser-driven proton–boron fusion experiments. We also show the production of 11 C radioisotopes, ≈ 6 × 10 6 , and of 44 Sc radioisotopes, ≈ 5 × 10 4 per laser shot. This result can open the way to develop laser-driven radiation sources of radioisotopes for medical applications.

gamma ray spectroscopy

Stabilization of Preternatural Barium Oxidation States as an Unexpected Byproduct of β-Decay: Discovery of a New Halide Semiconductor Alloy

137 Cs has a wide range of roles in the nuclear industry. The solid material, safely encapsulated in CsCl as 137 CsCl, is stored as fission product waste from nuclear power production and legacy waste from nuclear weapons production; it has also served as a radiation source in food and sewage irradiators as well as medical devices. However, because of the solubility of the chloride salt and the relatively high specific activity of 137 Cs, damaged or broken capsules can lead to severe radiological accidents. Safe capsule design and material recycling are complicated by the unclear structural evolution during β-decay, which remains ambiguous due to the differing oxidation states of Cs (1+) and Ba (2+). Here, in this study, we use first-principles calculations to investigate the evolving structure–property relationships of Cs 1–x Ba x Cl during β-decay. Despite the well-established 2+ formal oxidation state of alkali-earth metals, we find that Ba 1+ can be stabilized in the form of a mixed-valence alloy at low concentrations. Specifically, we identify three regimes for the β-decay of 137 Cs into CsCl: Ba-doped CsCl (Ba ≤ 14%), wherein Ba has the expected 2+ oxidation state; Cs–Ba–Cl alloys, where Ba has a mix of the usual Ba 2+ and highly unusual Ba 1+ oxidation state in the form of a quasi-disordered mixed-valence alloy (Ba = 25%); and phase separation into a CsCl + BaCl 2 + Ba (m) mechanical mixture, where Ba reverts to its expected 2+ oxidation state (Ba > 25%). Surprisingly, the Cs 0.75 Ba 0.25 Cl mixed-valence alloy is a narrow indirect band gap semiconductor (1.05 eV) despite the insulating nature of both CsCl and BaCl 2 . It also exhibits strongly excitonic polarized optical properties, has glass-like ultralow thermal conductivity (directional average of 0.21 W/mK at 300 K), and shows greater resistance to deformation under both tensile and volumetric strengths compared with the original CsCl structure (e.g., shear and Young’s modulus of 9.04 and 31.62 GPa, respectively). These findings imply that transmutation of 137 Cs leads to highly unusual chemical bonding that stabilizes Ba 1+ in local regions of the quasi-disordered Cs 0.25 Ba 0.75 Cl, resulting in anomalous physical properties. Moreover, this discovery provides valuable insight for safe nuclear waste capsule design, which can aid in preventing environmental or human exposure to radioactive materials.

Fuhr, Addis S. [Oak Ridge National Laboratory (ORN

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics

Scintillation event imaging with a single photon avalanche diode camera

Position and time measurements of scintillation events encode information about the radiation source. Single photon avalanche diode (SPAD) arrays offer multiple-megapixel spatial resolution and tens of picoseconds temporal resolution for detecting single photons. Current lensless designs for measuring scintillation events use sensors that are lower in spatial resolution. Camera-based designs use sensors that are lower in temporal resolution or readout rate and cannot image individual interactions. Here we propose to image scintillation events in a thick, monolithic scintillator using a high-resolution SPAD camera. We demonstrate that a commercial SPAD camera is able to gather sufficient signal to image individual scintillation events and observe 3D shifts in their spatial distribution. Simulations show that a SPAD camera can localize individual scintillation events in 3D. We report direct imaging of gamma-ray interactions in a scintillator with a SPAD camera. The proposed design may allow to measure complex signatures of individual particles interacting in the scintillator.

47 OTHER INSTRUMENTATION

Iron dopant energy levels in β-Ga 2 O 3

The energetic positions of the two Fe dopant levels in the bandgap of β-Ga 2 O 3 are determined to be at 3.05(±0.05) and 3.85(±0.05) eV below the conduction band minimum from transmission measurements employing a sub-picosecond tunable ultraviolet laser radiation source. A further measurement of the quantum efficiency of photoelectron emission from the Fe:Ga 2 O 3 (010) photocathode is consistent with the obtained absorption data and a dominant optical phonon assisted Franck–Condon emission mechanism, while also providing an estimate of 100 ps for the conduction band electron lifetime.

24 POWER TRANSMISSION AND DISTRIBUTION

Quantification and visualization of uncertainties in reconstructed penumbral images of implosions at Omega

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference’s uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

Instruments & Instrumentation