Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Saturn Radiation Dose Environment Characterization

To understand the environment where a time-resolved hard x-ray spectrometer (AXIOM) might be fielded, experiments and simulations were performed to analyze the radiation dose environment underneath the Saturn vacuum dome. Knowledge of this environment is critical to the design and placement of the spectrometer. Experiments demonstrated that the machine performance, at least in terms of on-axis dose, has not significantly changed over the decades. Simulations of the off-axis dose were performed to identify possible spectrometer locations of interest. The effects from the source and dome hardware as well as source distributions and angles of incidence on the radiation environment were also investigated. Finally, a unified radiation transport model was developed for two widely used radiation transport codes to investigate the off-axis dose profiles and the time-dependent x-ray energy spectrum. The demonstrated equivalence of the unified radiation transport model between the radiation transport codes allows the team to tie future time-dependent x-ray environment calculations to previous integral simulations for the Saturn facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

RADIATION DOSE SIMULATIONS FOR JEFFERSON LAB’S PERMANENT MAGNET RESILIENCY LDRD STUDY

In late 2023, Thomas Jefferson National Accelerator Facil- ity (Jefferson Lab) funded a Laboratory Directed Research and Development (LDRD) grant dedicated to investigating the impact of radiation on permanent magnet materials. This research initiative is specifically geared towards assessing materials slated for use in the CEBAF energy upgrade. The experimental approach involves strategically placing perma- nent magnet samples throughout the accelerator, exposing them to varying radiation doses. The simulation code BD- SIM is used to first validate the data and then to simulate the effects on future higher energy passes to study the degra- dation effects on the permanent magnets. In this paper we present the progress of that work.

Deitrick, K.↗

Spatial and temporal prediction of radiation dose rates near Fukushima Daiichi Nuclear Power Plant

In this paper, we have developed a methodology to estimate the spatiotemporal distribution of radiation air dose rates around the Fukushima Daiichi Nuclear Power Plant (FDNPP). In our exploratory data analysis, we found that (1) the temporal evolution of dose rates is composed of a log-linear decay trend and fluctuations of air dose rates that are spatially correlated among adjacent monitoring posts; and (2) the slope of the log-linear environmental decay trend can be represented as a function of the apparent initial dose rates, coordinate position, land-use type, and soil type. From these observations, we first estimated the log-linear decay trend at each location based on these predictors, using the random forest method. We then developed a modified Kalman filter coupled with a Gaussian process model to estimate the dose-rate time series at a given location and time. We applied this method to the Fukushima evacuation zone (as of March 2017), which included 17 monitoring post locations (with monitoring datasets collected between 2014 and 2018) and generated a time series of dose-rate maps. Our results show that this approach allows us to produce accurate spatial and temporal predictions of radiation dose-rate maps using limited spatiotemporal measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the Determination of the Radiation Doses at Hiroshima [Slides]

Essentially all knowledge regarding the chronic effects of radiation exposure is derived from statistical analyses of the survivors of Hiroshima and Nagasaki. However, we were then, and are now, uncertain about the exposures. That is: We know the effects through observations and statistical analyses, but we can only estimate the doses. Other complications include the fact that Little Boy was truly unique. It was never tested, measurements of yield were ambiguous, calculations of yield were not consistent, and calibration measurements were not made, could not be made.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Dose Modeling for Niowave’s Accelerator Driven Uranium Target Assembly 3

Molybdenum-99 is a high-value radionuclide commonly used for medical purposes within the United States. The National Nuclear Security Administration (NNSA) seeks to reliably produce the radioisotope 99 Mo without the use of highly enriched uranium. NNSA’s Office of Material Management and Minimization (M3) provides funding and government laboratory expertise to private companies to expedite the production process domestically and currently funds designs that use low-enriched uranium or other 99 Mo production pathways. Several production designs are being explored across the industry, including uranium fission and photonuclear conversion of 100 Mo targets. Niowave Inc. seeks to produce 99 Mo via a high-energy electron accelerator that strikes a lead-bismuth eutectic target that ultimately produces a consistent neutron flux. The neutron flux then interacts in a subcritical reactor core configuration to produce fission in low-enriched or natural uranium targets. These fissionable targets are then processed to extract 99 Mo. The purpose of this work is to estimate the neutron and photon dose response across Niowave’s proposed facility for worker safety during operation. Owing to the size of the proposed Niowave facility and necessary shielding, unbiased Monte Carlo radiation transport is impractical, and variance reduction methods are required. This work focuses on the weight window variance reduction method to produce high confidence dose response results within a Monte Carlo radiation transport code. Specifically, an adjoint-informed weight window methodology was created to improve the dose response estimates for accelerator-driven subcritical reactor designs. This adjoint-informed methodology was implemented for Niowave’s proposed design and improved dose results at far-field locations across the facility. Acceptable dose rate contours for the proposed facility were generated across the facility and are presented in this work.

07 ISOTOPE AND RADIATION SOURCES↗

Internal Radiation Dose Evaluation For An Unruptured Post Release Tristructural Istropic Fuel Particle for Advanced and Micro-reactor Applications

There are unique benefits from advanced/micro reactor designs and fuel types that offer safety features in the case of an accident that may reduce environmental consequences compared to conventional reactors and fuels. Several micro reactor designs, for both civilian and military applications, are proposed using tristructural-isotropic (TRISO) fuel. TRISO particles are a robust advanced nuclear fuel type that leads to the unique question of how unruptured, activated TRISO particles will interact with humans. Human exposure to nuclear fuel, or radionuclides, includes all pathways of exposure. However, TRISO particles are 0.9 mm in size, and that particle size restricts internal dose assessment to the ingestion pathway; eliminating the inhalation and dermal absorption pathways. Furthermore, activity of the TRISO particle was established by High Temperature Engineering Test Reactor simulations assuming the TRISO particle was one day post-release from the reactor. International Commission of Radiological Protection publications 100 and 133 were used to develop the internal dosimetry model for an unruptured TRISO particle for the International Commission of Radiological Protection reference male and female dose assessment. The rectosigmoid colon had the highest internal organ dose for both reference male (2.1 Sv) and reference female (2.3 Sv). The internal dose from ingestion of the scenario-defined TRISO particle was 0.25 Sv for the reference male and 0.29 Sv for the refence female, which exceeds the annual occupational effective dose limit of 0.05 Sv in the code of federal regulations, 10.CFR.20 Subpart C.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measuring Very Low Radiation Doses in PTFE for Nuclear Forensic Enrichment Reconstruction

Every country that has made nuclear weapons has used uranium enrichment. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment that can be used to perform forensic verification of historically produced weapons. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon's quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing a detection of tampering and a method for analyzing field samples useful for treaty verification. This work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

Connick, Rachel↗

Measuring very low radiation doses in PTFE for nuclear forensic enrichment reconstruction

Every country that has made nuclear weapons has used uranium enrichment to do so. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment in the open literature that can be used to perform forensic verification of historically produced weapons on gas centrifuges. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon’s quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing detection of tampering and a method for analyzing field samples useful for treaty verification. Furthermore, this work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Emergency Radiation Dose Rate Monitoring During Prolonged Armed Conflict

The 2022 Russian full-scale invasion of Ukraine has introduced unprecedented challenges for the nuclear power generation and radiological safety communities, including occupation and disturbance of highly-contaminated areas, occupation of a nuclear power plant, and strikes near and within boundaries of nuclear sites. The war has necessitated the implementation of a supplementary dose rate sensor network to provide resilient measurement data for public protection and leadership awareness. This paper discusses the implementation of such a system, the factors determining what equipment is best suited for the purpose, and practical factors regarding deployment of the system and data management. The crucial factors for operating a supplementary dose rate sensing network are backup power and communications options for dose rate sensors to make the network resilient to the effects of military operations. The most important implementation factor is to plan for extended operations beyond those typically considered for emergency response given the unpredictable nature of warfare.

resilience↗

Structural, Criticality, and Radiation Dose Calculations to Support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m-long and 45.7-cm-diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at INL’s CPP-603 facility. The ISS includes a 316L stainless-steel basket that holds 12 PB2 SNF rods. The PB2 basket rests on top of six individual, 78.7-cm-long, 316L stainless-steel columns that are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister above the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture Version 6.2, including ENDF/B-V continuous-energy cross-section libraries, considering intact SNF in a single storage overpack or two multistorage overpack configurations and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and a 27-group neutron-source spectrum were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of 1 m from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Furthermore, this study provides confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗