Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation-hard detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of proton irradiation on 4H-SiC Low Gain Avalanche Detectors (LGADs)

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.

43 PARTICLE ACCELERATORS↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

A radiation tolerant clock generator for the CMS endcap timing layer readout chip

Here, we present the test results of a low jitter Phase Locked Loop (PLL) prototype chip for the CMS Endcap Timing Layer readout chip (ETROC). This chip is based on the improved version of a clock synthesis circuit named ljCDR from the Low Power Gigabit Transceiver (lpGBT) project. The ljCDR is tested in its PLL mode. An automatic frequency calibration (AFC) block with the Triple Modular Redundancy (TMR) register is developed for the LC-oscillator calibration. The chip was manufactured in a 65 nm CMOS process with 10 metal layers. The chip has been extensively tested, including Total Ionizing Dose (TID) testing up to 300 Mrad and Single Event Upset (SEU) testing with heavy ions possessing a Linear Energy Transfer (LET) from 1.3 to 62.5 MeV × cm 2 /mg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

QTIA, a 2.5 or 10 Gbps 4-channel array optical receiver ASIC in a 65 nm CMOS technology

Here, the Quad transimpedance and limiting amplifier (QTIA) is a 4-channel array optical receiver ASIC, developed using a 65 nm CMOS process. It is configurable between the bit rate of 2.56 Gbps and 10 Gbps per channel. QTIA offers careful matching to both GaAs and InGaAs photodiodes. At this R&D stage, each channel has a different biasing scheme to the photodiode for optimal coupling. A charge pump is implemented in one channel to provide a higher reverse bias voltage, which is especially important to mitigate radiation effects on the photodiodes. The circuit functions of QTIA successfully passed the lab tests with GaAs photodiodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The AMACStar ASIC for the HL-LHC ATLAS ITk Strip detector: design, verification, testing, and quality assurance

For the high-luminosity upgrade to the LHC (HL-LHC), the ATLAS detector at CERN requires an all-new inner detector, the Inner Tracker (ITk). The ITk Strip subdetector is made up of silicon modules, which include three types of radiation-hard ASICs. One of these is the Autonomous Monitor and Control (AMAC). The AMAC is manufactured by Global Foundries using 130 nm CMOS8RF DM technology and is approximately 3 by 5 mm in size. This ASIC autonomously monitors the temperatures, voltages, and currents in the module components while controlling critical values in order to prevent these quantities from reaching dangerous levels. The final design, AMACStar, was verified, tested, and ensured to perform all necessary functions. A quality control procedure using an in-house probe station set-up was developed in order to ensure that every individual chip on each wafer of AMACStars required by the ITk Strip project met performance requirements. The average per wafer yield of usable AMACStars is 92.33%, exceeding the design-specific 90% yield estimated for project costing. This estimate was based on actual yields for similar designs in this process.

Analogue electronic circuits↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronics for the far-forward CMS muon detector upgrade, ME0

Abstract With the High Luminosity upgrade of the Large Hadron Collider (LHC) we expect increased instantaneous luminosities up to 7.5 × 10 34 cm −2 s −1 , or five times more than the original values. In order to maintain performance of the Compact Muon Solenoid (CMS) experiment under these conditions, ME0 is one of three new muon sub-detectors being added, along with GE1/1 and GE2/1, which use the triple Gas Electron Multiplier (GEM) technology. ME0 is designed to cover the forward region of 2.0 < | η | < 2.8, thus improving muon reconstruction at high background rates by supplementing other overlapping muon subsystems up to | η | = 2.4, while also extending the acceptance for the first time to | η | = 2.8. The readout electronics for ME0 must be designed to accommodate high data rates and be sufficiently radiation hard to operate close to the beamline. The Optohybrid (OH) board for ME0, which reads out data from the front-end VFAT3b ASICs, has therefore been designed to operate without an FPGA (unlike GE1/1 and GE2/1) to ensure radiation hardness. The ME0 OH uses the radiation-hard CERN-designed lpGBT ASIC and VTRx+ optical transceiver module for high bandwidth optical links up to 10.24 Gb/s. The backend system is based on the ATCA standard. The design and development status of the readout electronics for ME0 is presented, along with recent results from integration tests performed using the first prototypes.

Instruments & Instrumentation↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗