Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiological Mapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparative Assessment of Data-driven Process Models in Health Information Technology

Process mining for conformance analysis consists of comparing a reference process model against a data-driven process model generated via log files from information technology systems. However, in the absence of a complete reference process model, we found no suggested approaches in the literature to address the need for evaluating process conformance among different healthcare facilities to assess standardization of care. Our goal is to find similarities and dissimilarities in data-driven process models among US Veterans Health Administration (VHA) facilities that can be indicative of patient safety issues. Our hypothesis was that the analysis would not produce statistically significant differences in outcome. We present a unique implementation of conformance analysis in process mining that consists of combining process mining, process mapping and statistical metrics. We illustrate our approach by applying it to the analysis of two clinical radiology order process models generated from healthcare data provided by two similar facilities in the VHA. The comparative assessment showed that about 70% of the orders completed successfully and 30% were not completed due to policy and duplications. Our analysis found a good statistical correlation between both facilities, as the Spearman’s correlation coefficient between facilities for the frequency of cases per total hours was 0.87879, for the frequency of cases by state transition was 0.79702 and for the throughput time per state transition was 0.63582. Additional statistical analyses using the Mann-Whitney U test and the root mean square error both produced values that were not significant. The foregoing approach validated our hypothesis by demonstrating a good statistical correlation of data describing the flow of clinical radiology orders absent a credible reference model. Finding good agreement between both facilities was important in confirming that the clinical orders flow in a similar manner, suggesting standardization of care.

97 MATHEMATICS AND COMPUTING↗

Tomographic detection of photon pairs produced from high-energy X-rays for the monitoring of radiotherapy dosing

Measuring the radiation dose reaching a patient’s body is difficult. Here we report a technique for the tomographic reconstruction of the location of photon pairs originating from the annihilation of positron–electron pairs produced by high-energy X-rays travelling through tissue. We used Monte Carlo simulations on pre-recorded data from tissue-mimicking phantoms and from a patient with a brain tumour to show the feasibility of this imaging modality, which we named ‘pair-production tomography’, for the monitoring of radiotherapy dosing. We simulated three image-reconstruction methods, one applicable to a pencil X-ray beam scanning through a region of interest, and two applicable to the excitation of tissue volumes via broad beams (with temporal resolution sufficient to identify coincident photon pairs via filtered back projection, or with higher temporal resolution sufficient for the estimation of a photon’s time-of-flight). In addition to the monitoring of radiotherapy dosing, we show that image contrast resulting from pair-production tomography is highly proportional to the material’s atomic number. The technique may thus also allow for element mapping and for soft-tissue differentiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intelligent Consequence Control by Aerial Reconnoiter Using Unmanned Systems

In a nuclear accident, or in the aftermath of an improvised nuclear device or radiological dispersal device detonation, radioactive materials may pose a severe health threat to individuals near the site of the incident. The Intelligent Consequence Control by Aerial Reconnoiter Using Unmanned Systems (ICARUS) does the dull, dirty, and dangerous (and, sometimes, deep) work of mapping and characterizing valuable information to enable a safe and appropriate response. ICARUS provides timely answers to the questions, “What is it?” “Where is it?”, and “How far does it extend?” Using commercial, off-the-shelf proven components, the integrated chemical, biological, radiological, nuclear, and explosives detection architecture for our drones provides a solution for collecting radiological, chemical, and optical information on developing complex situations, returning actionable data for determining if it is safe for further response efforts. ICARUS can determine and transmit the location, identity, and intensity of radionuclide contamination to a remote base station. It can deliver on the unexpected.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Explaining machine-learning models for gamma-ray detection and identification

As more complex predictive models are used for gamma-ray spectral analysis, methods are needed to probe and understand their predictions and behavior. Recent work has begun to bring the latest techniques from the field of Explainable Artificial Intelligence (XAI) into the applications of gamma-ray spectroscopy, including the introduction of gradient-based methods like saliency mapping and Gradient-weighted Class Activation Mapping (Grad-CAM), and black box methods like Local Interpretable Model-agnostic Explanations (LIME) and SHapley Additive exPlanations (SHAP). In addition, new sources of synthetic radiological data are becoming available, and these new data sets present opportunities to train models using more data than ever before. In this work, we use a neural network model trained on synthetic NaI(Tl) urban search data to compare some of these explanation methods and identify modifications that need to be applied to adapt the methods to gamma-ray spectral data. We find that the black box methods LIME and SHAP are especially accurate in their results, and recommend SHAP since it requires little hyperparameter tuning. We also propose and demonstrate a technique for generating counterfactual explanations using orthogonal projections of LIME and SHAP explanations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated System for Early Breast Cancer Detection in Mammograms

The increasing demand on mammographic screening for early breast cancer detection, and the subtlety of early breast cancer signs on mammograms, suggest an automated image processing system that can serve as a diagnostic aid in radiology clinics. We present a fully automated algorithm for detecting clusters of microcalcifications that are the most common signs of early, potentially curable breast cancer. By using the contour map of the mammogram, the algorithm circumvents some of the difficulties encountered with standard image processing methods. The clinical implementation of an automated instrument based on this algorithm is also discussed.

Bankman, Isaac N.↗

Python Urban Deployment Model (PyUDM) v1.0.0

The Python Urban Deployment Model (PyUDM) is a simulation tool used to investigate networks of static radiation detectors in urban environments. PyUDM simulates traffic, stationary NaI gamma-ray detectors, and moving radioactive sources on simulated vehicles. The analyzed output of the simulations contain valuable insights into the performance of different configurations of urban radiological detector configurations such as their ability to detect sources moving through the environment. To accurately simulate radioactive material moving through urban environments, PyUDM combines Monte Carlo simulation tools, publicly available map and traffic data, and measured gamma-ray spectra from urban environments.

Rofors, Emil↗

A reliable workflow for improving nanoscale X-ray fluorescence tomographic analysis on nanoparticle-treated HeLa cells

Abstract Scanning X-ray fluorescence (XRF) tomography provides powerful characterization capabilities in evaluating elemental distribution and differentiating their inter- and intra-cellular interactions in a three-dimensional (3D) space. Scanning XRF tomography encounters practical challenges from the sample itself, where the range of rotation angles is limited by geometric constraints, involving sample substrates or nearby features either blocking or converging into the field of view. This study aims to develop a reliable and efficient workflow that can (1) expand the experimental window for nanoscale tomographic analysis of local areas of interest within a laterally extended specimen, and (2) bridge 3D analysis at micrometer and nanoscales on the same specimen. We demonstrate the workflow using a specimen of HeLa cells exposed to iron oxide core and titanium dioxide shell (Fe3O4/TiO2) nanocomposites. The workflow utilizes iterative and multiscale XRF data collection with intermediate sample processing by focused ion beam (FIB) sample preparation between measurements at different length scales. Initial assessment combined with precise sample manipulation via FIB allows direct removal of sample regions that are obstacles to both incident X-ray beam and outgoing XRF signals, which considerably improves the subsequent nanoscale tomography analysis. This multiscale analysis workflow has advanced bio-nanotechnology studies by providing deep insights into the interaction between nanocomposites and single cells at a subcellular level as well as statistical assessments from measuring a population of cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Countering Weapons of Mass Destruction (CWMD) Zero Trust Framework: CWMD Zero Trust Principles Model

The research focuses on the critical need for enhanced cybersecurity within the Countering Weapons of Mass Destruction (CWMD) Office, specifically targeting Chemical, Biological, Radiological, and Nuclear devices. Traditional perimeter-based security models are insufficient against modern cyber threats, prompting a shift toward Zero Trust principles (ZTP) that emphasize continuous verification and stringent security for all devices. Federal directives mandate the adoption of Zero Trust (ZT) across agencies, supported by guidelines from National Institute of Standards and Technology (NIST), U.S. Department of Homeland Security (DHS) Cybersecurity and Infrastructure Security Agency (CISA), U.S. Department of Defense (DoD) and National Security Agency (NSA). The research involved mapping ZT guidance from these agencies to develop tailored CWMD ZTP. The study identified gaps and areas for improvement, including clear transitional guidance from traditional to ZT architectures and the focus on explicit cross cutting capabilities. Design improvements are recommended to ensure increased comprehensive protection and resilience against sophisticated cyber threats for Chemical, Biological, Radiological, and Nuclear (CBRN) devices. Collaborative efforts among federal agencies are essential for the successful deployment of an optimized ZT guidance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Radiation Mapping UAV [Poster]

The NuMI (Neutrinos at the Main Injector) target system delivers a high-energy flux of muon-neutrinos towards a detector more than 800 km away with the goal of better understanding the origin of the universe and its evolution. The target system becomes radioactive because it is irradiated by a sub-Mega-Watt power proton beam. Radiological hazard is one of critical issues for a radiological worker which limits the iractivities near the target system; however, they often need to quantify the radiation level of the target system manually. Thus, the objective of this project is to reduce their exposure to radiation while improving the accuracy of the measurements. A quadcopter UAV fitted with a radiation dosimeter is ideal to traverse the irradiated environment as it can be deployed in any space and requires minimal hardware integration to the test room. Due to the lack of indoor GPS signal, this UAV utilizes a series of ultrasonic beacons that release several varied-frequency pulses simultaneously in order to localize the drone. The flight controller returns a 3D coordinate tied to the radiation data to understand precisely where radiation spikes are being emitted from the horn. The flight controller stores log data that can be processed into an easily interpretable map of radiation intensities. The radiation map serves as one of the primary references for planning the transportation of the NuMI horn.

43 PARTICLE ACCELERATORS↗

Radiological Source Term Estimation and Isotopic Identification with Parallel Log Domain Particle Filters

This paper presents a parallel log-domain particle filtering algorithm combined with gamma spectrum unfolding to perform localization, identification, and evaluation of multiple point sources of various isotopes in an environment with attenuating obstacles. The method uses sets of precomputed attenuation kernels that map the attenuation characteristics of the environment. These kernels are specific to the energy level of a photopeak of interest. The spectral measurements are deconvolved into count measurements of each photopeak. These count measurements are fed into a set of parallel particle filters using attenuation kernels computed for that photopeak’s energy level. The individual regularized particle filters perform all likelihood calculations in the logarithmic domain to mitigate the effects of particle degeneracy. The output of each particle filter is combined to estimate which isotopes are present as well as their positions and strengths. The performance of the algorithm is characterized in a lab-scale environment using a mobile robot equipped with a gamma ray spectrometer in the presence of up to three different radioactive isotopes simultaneously. The sources were localized to within 10 cm, and their strengths were estimated within 10% of their true values. Furthermore, the isotopes were all correctly identified, and no spurious sources were reported.

42 ENGINEERING↗

Multi-modal Free-moving Data Fusion (MFDF) v1.0

Multi-modal Free-moving Data Fusion (MFDF) is a python package that implements low and high-level functionality for performing qualitative and quantitative gamma-ray imaging analyses. Such analyses enable the use of gamma-ray spectrometers and/or imagers to estimate the distribution and quantity of radiological materials in an environment. Free-moving 3D imaging requires additional information about the 3D trajectory and orientation of the system, however all of these methods can be applied to 2D static gamma-ray imaging as well. The package includes methods (MLEM and MAP) for distributed source reconstruction, methods (PSL) for point source reconstruction, the ability to ingest and utilize quantitative detector response functions (for absolute analyses), and the ability to perform 3D estimation of dose-rates from quantitative reconstructions.

Joshi, Tenzing↗

Preliminary analyses of space radiation protection for lunar base surface systems

Radiation shielding analyses are performed for candidate lunar base habitation modules. The study primarily addresses potential hazards due to contributions from the galactic cosmic rays. The NASA Langley Research Center's high energy nucleon and heavy ion transport codes are used to compute propagation of radiation through conventional and regolith shield materials. Computed values of linear energy transfer are converted to biological dose-equivalent using quality factors established by the International Commision of Radiological Protection. Special fluxes of heavy charged particles and corresponding dosimetric quantities are computed for a series of thicknesses in various shield media and are used as an input data base for algorithms pertaining to specific shielded geometries. Dosimetric results are presented as isodose contour maps of shielded configuration interiors. The dose predictions indicate that shielding requirements are substantial, and an abbreviated uncertainty analysis shows that better definition of the space radiation environment as well as improvement in nuclear interaction cross-section data can greatly increase the accuracy of shield requirement predictions.

Nealy, John E.↗

Towards a Comparative Assessment of Data-Driven Process Models in Health Information Technology

Process mining for conformance analysis focuses on comparing a reference process model against a data-driven process model that is generated via log files from information technology systems. While this approach is helpful when there is an existing process model in an organization, it leaves the question of what to do in the absence of a complete reference process model unanswered. In this paper, we present a comparative assessment approach that combines process mining, process mapping for dimensionality reduction, and statistical analysis. Our goal is to find similarities and dissimilarities in data-driven process models among U.S. Veterans Health Administration (VHA) facilities to assess process conformance among different healthcare facilities, which can help assess the standardization of care. We illustrate our approach by applying it to two clinical radiology order process models generated by two similar facilities. Our results demonstrate statistical similarities in the standardization of care among those two facilities.

Klasky, Hilda↗

Application of Shift Ex-Core Calculations to a Detailed MSR Model

This report documents the collaborative research conducted between Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL) on applying the Monte Carlo neutronics code Shift to calculate the radiation dose rates for a detailed molten salt reactor (MSR) model based on the Molten Salt Breeder Reactor (MSBR). In this work scope, the ANL and ORNL teams worked together and applied Shift to calculate the radiological environments of this detailed MSR facility modeled with explicit geometries. The radiological conditions within the MSR facility were modeled for when the reactor is at two different operation modes: normal full power and drained state. The FW-CADIS hybrid method in Shift was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Dose rate maps showed that in the current MSBR numerical model, potential pathways exist for neutrons and gammas to stream through the 8-foot concrete shield to reach the top of the MSBR reactor cell. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the Shift simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates, which suggests that a steel liner in the tank model must be added for calculating the dose rates in the drain cell.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗