Search for High-Pressure Silicon Phases: Reaching the Extreme Conditions with High-Intensity Laser Irradiation

Controlling electronic and optical properties of semiconducting materials could substantially expand their functionality and enable new pathways for the formation of ‘smart’ materials for emerging innovative applications. An emerging new path for the synthesis of exotic silicon (Si) polymorphs is irradiation of bulk diamond-cubic Si by ultrashort laser pulses at relativistic intensity above 1019 W/cm2. Exotic polymorphs are formed due to interaction with MeV-energy electrons generated in laser-produced high-temperature plasma state. The unusual Si structures are found in the form of 5–10 nm nanoparticles confined deep in the bulk of 500-μm-thick Si samples. Raman spectroscopy, electron microscopy and X-ray diffraction studies provide an unequivocal evidence of exotic Si phase formation. A key advantage of such relativistic irradiation lies thereby in the fact that large quantities of such exotic Si is synthesised embedded within the bulk diamond-cubic Si and that further the formed Si polymorphs are stable at ambient temperature and pressure. They are thus available for further studies for electronic applications in selective band gap engineering.

Rapp, Ludovic↗

Phase separation during the direct powder bed fusion of SiC

Powder bed fusion (PBF) is an attractive additive manufacturing option for fabrication of SiC object with complex geometries. However, the density and microstructure controls remain a challenge. This study is aimed at understanding laser–SiC interactions, with emphasis on microstructure-processing relationships, to identify potential solutions for the process improvement. SiC tubes were fabricated by PBF of pure SiC powders without sintering additives. Further, comprehensive analysis by X-ray diffraction, Raman spectroscopy, and electron microscopy indicated that binding of SiC particles was achieved by incongruent melting of SiC to a Si/C mixture containing SiC micro- and nanocrystallites. The phase evolution under laser irradiation of SiC was explained by phase diagrams. This study uncovered the PBF SiC microstructure at different length scales and the relationship between the microstructure and the processing parameters.

36 MATERIALS SCIENCE↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Magnetic functionalization and catalytic behavior of magnetic nanoparticles during laser photochemical graphitization of polyimide

We report laser-assisted photochemical graphitization of polyimides (PIs) into functional magnetic nanocomposites using laser irradiation of PI in the presence of magnetite nanoparticles (MNPs). PI Kapton sheets covered with MNP were photochemically treated under ambient conditions using a picosecond pulsed laser (1064 nm) to obtain an electrically conductive material. Scanning electron microscopy of the treated material revealed a layered magnetic nanoparticle/graphite (MNP/graphite) nanocomposite structure. Four probe conductivity measurements indicated that the nanocomposite has an electrical conductivity of 1550 ± 60 S/m. Superconducting quantum interference device magnetometer-based magnetic characterization of the treated material revealed an anisotropic ferromagnetic response in the MNP/graphite nanocomposite compared to the isotropic response of MNP. Raman spectroscopy of the MNP/graphite nanocomposite revealed a fourfold improvement in graphitization, suppression in disorder, and decreased nitrogenous impurities compared to the graphitic material obtained from laser treatment of just PI sheets. X-ray photoelectron spectroscopy, x-ray diffraction, and energy-dispersive x-ray spectroscopy were used to delineate the phase transformations of MNP during the formation of MNP/graphite nanocomposite. Post-mortem characterization indicates a possible photocatalytic effect of MNP during MNP/graphite nanocomposite formation. Under laser irradiation, MNP transformed from the initial Fe 3 O 4 phase to γ-Fe 2 O 3 and Fe 5 C 2 phases and acted as nucleation spots to catalyze the graphitization process of PI.

36 MATERIALS SCIENCE↗

Comparing Sensor Fusion and Multimodal Chemometric Models for Monitoring U(VI) in Complex Environments Representative of Irradiated Nuclear Fuel

Optical sensors and chemometric models were leveraged for the quantification of uranium(VI) (0–100 μg mL –1 ), europium (0–150 μg mL –1 ), samarium (0–250 μg mL –1 ), praseodymium (0–350 μg mL –1 ), neodymium (0–1000 μg mL –1 ), and HNO 3 (2–4 M) with varying corrosion product (iron, nickel, and chromium) levels using laser fluorescence, Raman scattering, and ultraviolet–visible–near-infrared absorption spectra. In this paper, an efficient approach to developing and evaluating tens of thousands of partial least-squares regression (PLSR) models, built from fused optical spectra or multimodal acquisitions, is discussed. Each PLSR model was optimized with unique preprocessing combinations, and features were selected using genetic algorithm filters. The 7-factor D-optimal design training set contained just 55 samples to minimize the number of samples. The performance of PLSR models was evaluated by using an automated latent variable selection script. PLS1 regression models tailored to each species outperformed a global PLS2 model. PLS1 models built using fused spectra data and a multimodal (i.e., analyzed separately) approach yielded similar information, resulting in percent root-mean-square error of prediction values of 0.9–5.7% for the seven factors. Further, the optical techniques and data processing strategies established in this study allow for the direct analysis of numerous species without measuring luminescence lifetimes or relying on a standard addition approach, making it optimal for near-real-time, in situ measurements. Nuclear reactor modeling helped bound training set conditions and identified elemental ratios of lanthanide fission products to characterize the burnup of irradiated nuclear fuel. Leveraging fluorescence, spectrophotometry, experimental design, and chemometrics can enable the remote quantification and characterization of complex systems with numerous species, monitor system performance, help identify the source of materials, and enable rapid high-throughput experiments in a variety of industrial processes and fundamental studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microbial Pigments and Their Degradation Products as Biosignatures

Carotenoids are a class of vibrant biological pigments that have a characteristic chemical structure centered around a polyene core (Lu et al. 2018). Carotenoids and their derivatives are candidate biosignatures because they can persist in the terrestrial geologic record for up to 1.73 billion years (Vinnichenko et al. 2020), have specific structures that are likely the result of complex pathways, mediate the survival of many microorganisms in Mars and Ocean Worlds analog environments, and are detectable with multiple techniques, including Raman spectroscopy. In this project, we aim to investigate the detectability of carotenoid pigments with different spectroscopic methods to inform future instrument selection. We compare the spectra of five unaltered carotenoids, two model compounds, and carotenoid-forming archaeon with visible and deep UV Raman spectroscopy and UVVis absorption spectrophotometry. We then use one model pigment, beta-carotene, to evaluate the likelihood that unique spectral properties of carotenoids, or their refractory byproducts, would be preserved and detectable on a remote planetary surface by exposing it to simulated conditions for Mars. Sample Acquisition. Pigments betacarotene, lutein, zeaxanthin, astaxanthin, and lycopene were purchased from Sigma Aldrich. Halobacterium salinarum NRC-1 was acquired from Carlina Biological and grown in Halobacterium media. Mineral salts including sodium sulfate, sodium carbonate, and halite were used to form matrices in which the beta-carotene was embedded before exposure. Pigment-mineral mixes were at a 1:10 ratio in water. Analytical Techniques. Deep UV Raman data were collected on a custom laboratory mapping spectrometer called MOBIUS (Mineral and Organic Based Investigations using Ultraviolet Spectroscopy), which is an analog to the SHERLOC instrument on the Mars 2020 Perseverance rover (Bhartia et al. 2021). It features a 248.56 nm NeCu pulsed laser, liquid nitrogen-cooled detector, and tunable optical setup. Visible Raman data were collected using a Horiba Jobin Yvon LabRam HR spectrometer with a frequencydoubled Nd:YAG laser (532 nm) and a HeNe laser (633 nm). A VWR 6300 PC UV/Visible Spectrophotometer was used to collect absorption data for carotenoid solutions, model compounds, and solvents in UVpermissible capped cuvettes. Data were collected from 190-1100 nm at 1 nm increments. All spectral data were analyzed using Igor Pro 9 (Wavemetrics). Irradiation. We used a vacuum chamber equipped with a cryostat and a flood electron gun to simulate Martian surface temperatures, low pressures, and ionizing radiation (10keV, 10μA for 6h at 200K for our initial tests). The samples were prepared by drying the pigment-mineral mix onto polished metal tabs, then mounted on the cryostat for processing. Samples were then analyzed directly on the tabs after exposure. Results: In comparing the visible and deep UV Raman spectra of unaltered pigments, we found that they differed drastically. Carotenoids are often studied with visible Raman and typically have peaks at 1525 cm-1 and 1157 cm-1, due to the stretching of the C=C and C-C bonds in the polyene structure. However, in deep UV, the strongest feature is at ~1630 cm-1 and is broad, possibly indicating that multiple peaks are forming this feature. This stark difference is likely due to different preresonant enhancement effects. The UV-Vis results show that there is an absorption band in the deep UV <300 nm, which supports the hypothesis that the 248.6 nm excitation is interrogating another aspect of carotenoids than visible Raman. Our preliminary exposure tests indicated that pigments – even without minerals present - were largely unaltered in the applied conditions, with only a slight broadening in the primary polyene peaks apparent in the visible Raman data. Figure 1. A) Visible vs. deep UV Raman spectra of unaltered beta carotene. B) Schematic of exposure. Conclusions: Our results to date indicate that deep UV and visible Raman spectroscopy, both techniques with planetary mission heritage from Mars 2020 (Wiens et al. 2021, Bhartia et al. 2021), may be used in a complementary manner to observe carotenoids. In addition, we find that beta-carotene is largely resistant to our current exposure conditions, though there may be some amount of amorphization of the material which could cause the broadening of the peaks at 1525 and 1157 cm-1. As a next step, we aim to increase the dosage and duration of exposure to observe degradation of the parent pigment, possibly add UV as a factor via an Ar mini-arc UV lamp and use GC-MS to characterize possible degradation products.

pigments↗

Material for surface-enhanced Raman spectroscopy, and SER sensors and method for preparing same

Metal-doped sol-gel materials, suitable for use as sensors for surface-enhanced Raman spectroscopic analysis for trace chemical detection, are produced by effecting gelation and solvent removal of a doped sol-gel under mild temperature conditions. At least in certain instances reaction and drying will desirably be effected in an oxygen-starved environment. The metal of the sol-gel material functions, when irradiated, to produce a plasmon field for interaction with molecules of an analyte in contact therewith, increasing by orders of magnitude Raman photons that are generate by excitation radiation, and the method allows matching of the metal and metal particle size to a wavelength of light (or incident radiation, e.g., laser radiation) to generate surface plasmons. The porosity of the sol-gel material dramatically increases the surface area, and thereby the amount of metal exposed for analyte interaction. The sensors provided may be in the form of glass vials, fiber optics, multi-well micro-sample plates, etc., having surface coatings of the doped sol-gel material, to provide sampling systems for use in a Raman instrument.

Farquharson, Stuart↗

The Physical and Engineering Limits of Coupled In situ TEM Experiments

Almost all future energy systems (advanced nuclear reactors, fusion energy system, concentrating solar-thermal power (CSP), and wind technologies) are limited by degradation of key material systems exposed to multiple environmental stressors. The degradation during exposure to high temperatures, radiation, mechanical loading, and chemical attack is often dictated by mechanisms active at the microstructural level. The nature of these mechanisms and the associated variations between sequential and concurrent interplay can be explored if the transmission electron microscope (TEM) is utilized as a toolbox for exploration [1]. One such tool developed at Sandia National Laboratories to couple several of these environments is the In situ Ion Irradiation TEM (I3TEM) [2]. Several studies over the last decade utilizing this tool have shown that the scientific intuition developed over decades of sequential experiments is not always a good indicator of concurrent mechanisms or failure routes. This presentation will highlight the recent and planned additions into the I3TEM facility of a Waviks gas injection system and Raman system, respectively, as can be seen in Fig. 1, permitting environmental degradation from gas species leaked into the pole piece region during quantitative mechanical loading (indentation, monotonic loading, high temperature creep, irradiation induced creep, and high-cycle fatigue); multi-beam ion irradiation (energies ranging from 1 keV to 48 MeV and species from H to Au); laser exposure (20 W and 1064 nm), or various combinations thereof that are already possible [3]. This addition permits the facility to explore both sequential or concurrently the four axes of stressors: thermal, mechanical, radiation, and chemical. This information can be directly coupled to modeling, expediting the refinement and validation of both atomistic and mesoscale models.

degradation↗

Time Domain Thermoreflectance (TDTR) Studies of Microstructural Characterization of as-Fabricated and/or Irradiated TPBAR Components

Paddock et al. demonstrated for the first-time the measurement of thermal diffusivity from thin metal films using picosecond transient thermoreflectance in 1986. This project attempted to use a similar experimental setup based on a femtosecond time domain thermoreflectance (TDTR) to measure the damage to the crystal lattice of LiAlO 2 from irradiation in the reactor and production of tritium and helium. The TDTR is based on a pump-probe laser configuration where the pump laser is used to heat the sample and the probe laser is used to follow the thermal evolution created by the pump laser. The goal for this project is to measure the differences in thermal diffusivity between LiAlO 2 and the irradiated Li AIO 2 sample in a reactor. Unfortunately, COVID-19 restricted laboratory research time and the availability of researchers capable to conduct TDTR work. In addition, the ultrafast laser (Astrella 35fs laser) required to conduct the work was inoperable making this particulate work impossible to conduct in FY20 and FY21. The purpose of the thermal diffusion measurements with a TDTR setup is to probe the damage and disorder to the crystal lattice of pristine and irradiated samples. Since TDTR was not available for this work, a different approach using Raman and luminescence spectroscopy was used to characterize the crystal lattice damage in LiAlO 2 from irradiation.

07 ISOTOPE AND RADIATION SOURCES↗

Identification of stimulated Raman side scattering in near-spherical coronal plasmas on OMEGA EP

Recent spherical-target laser–plasma interaction experiments, performed on the OMEGA EP laser, have been analyzed for stimulated Raman scattering (SRS). This has been motivated by results obtained on the National Ignition Facility (NIF) that have demonstrated the importance of SRS, and in particular SRS side scatter, for directly driven inertial confinement fusion (ICF) conditions [Rosenberg et al. Phys. Rev. Lett. 120, 055001 (2018); Michel et al. Phys. Rev. E 99, 033203 (2019)]. The analysis, based on a generalized ray tracing approach, is described and is shown to explain the observed scattered light spectra: it identifies SRS convective scattering, from portions of each incident beam where the scattered electromagnetic wave is generated in the direction parallel to contours of constant density, as the dominant contribution. This result is novel, as SRS is mostly associated with plasmas of higher electron temperature (T e ≳ 3–4 keV) and longer density scale length (≳600 μ m) than those considered here (T e ~ 1–3 keV, Ln~150 μm) for the relevant overlapped irradiation intensities l ≲ 10 15 W/cm 2 . Furthermore, a combination of the high single-beam intensity on OMEGA EP and the side-scattering geometry, that has been identified, is responsible for this result. It is further suggested that the OMEGA EP platform could provide a good surrogate in which to develop SRS mitigation strategies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flash healing of laser-induced graphene

The advancement of laser-induced graphene (LIG) technology has streamlined the fabrications of flexible graphene devices. However, the ultrafast kinetics triggered by laser irradiation generates intrinsic amorphous characteristics, leading to high resistivity and compromised performance in electronic devices. Healing graphene defects in specific patterns is technologically challenging by conventional methods. Herein, we report the rapid rectification of LIG’s topological defects by flash Joule heating in milliseconds (referred to as F-LIG), whilst preserving its overall structure and porosity. The F-LIG exhibits a decreased I D /I G ratio from 0.84 – 0.33 and increased crystalline domain from Raman analysis, coupled with a 5-fold surge in conductivity. Pair distribution function and atomic-resolution imaging delineate a broader-range order of F-LIG with a shorter C-C bond of 1.425 Å. The improved crystallinity and conductivity of F-LIG with excellent flexibility enables its utilization in high-performance soft electronics and low-voltage disinfections. Notably, our F-LIG/polydimethylsiloxane strain sensor exhibits a gauge factor of 129.3 within 10% strain, which outperforms pristine LIG by 800%, showcasing significant potential for human-machine interfaces.

36 MATERIALS SCIENCE↗

Synthesis of TiO{sub 2} nanoparticles decorated with gold nanoclusters using pulsed laser ablation in liquid

Amorphous spherical titanium dioxide (TiO{sub 2}) nanoparticles, decorated gold nanoparticles, are shown to be formed under irradiation of commercial TiO{sub 2} nanopowders dispersed in aqueous solution of hydrogen tetrachloroaurate (HAuCl{sub 4}) by second-harmonic nanosecond pulses of an Nd : YAG laser. It is found that these hybrid nanostructures are formed during laser-induced remelting of the initial nanoparticles, stimulated by gold nanoclusters (providing more efficient absorption of visible laser radiation by titanium dioxide) recovered on their surface. The morphology and chemical composition of the newly formed hybrid nanomaterials are investigated in detail by electron microscopy, Raman spectroscopy, and energy-dispersive analysis. It is shown that the average size and number of gold nanoparticles recovered on the TiO{sub 2} surface can be controlled by varying the concentration ratio of the initial nanomaterial and HAuCl{sub 4}. A spectroscopic analysis of light scattering by single hybrid nanoparticles and the results of numerical calculation of the structure of electromagnetic fields near their surface indicate good prospects of these hybrid nanomaterials for various applications in modern optics, optoelectronics, and nanophotonics; for example, for designing chemo- and biosensor platforms and new-generation solar cells. (nanoparticles)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopic Chemical Analysis Methods and Apparatus

This invention relates to non-contact spectroscopic methods and apparatus for performing chemical analysis and the ideal wavelengths and sources needed for this analysis. It employs deep ultraviolet (200- to 300-nm spectral range) electron-beam-pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor lightemitting devices, and hollow cathode metal ion lasers. Three achieved goals for this innovation are to reduce the size (under 20 L), reduce the weight [under 100 lb (.45 kg)], and reduce the power consumption (under 100 W). This method can be used in microscope or macroscope to provide measurement of Raman and/or native fluorescence emission spectra either by point-by-point measurement, or by global imaging of emissions within specific ultraviolet spectral bands. In other embodiments, the method can be used in analytical instruments such as capillary electrophoresis, capillary electro-chromatography, high-performance liquid chromatography, flow cytometry, and related instruments for detection and identification of unknown analytes using a combination of native fluorescence and/or Raman spectroscopic methods. This design provides an electron-beampumped semiconductor radiation-producing method, or source, that can emit at a wavelength (or wavelengths) below 300 nm, e.g. in the deep ultraviolet between about 200 and 300 nm, and more preferably less than 260 nm. In some variations, the method is to produce incoherent radiation, while in other implementations it produces laser radiation. In some variations, this object is achieved by using an AlGaN emission medium, while in other implementations a diamond emission medium may be used. This instrument irradiates a sample with deep UV radiation, and then uses an improved filter for separating wavelengths to be detected. This provides a multi-stage analysis of the sample. To avoid the difficulties related to producing deep UV semiconductor sources, a pumping approach has been developed that uses ballistic electron beam injection directly into the active region of a wide bandgap semiconductor material.

Hug, William F.↗

Ramdb: The NASA Raman Spectral Database (version 1.00).

Given that, in most instances, minimal sample preparation is required and due to its contactless instrument design, Raman spectroscopy is one of the most versatile vibrational spectroscopic techniques for the chemical analysis of environmental and biological specimens. The diversity of applications of Raman spectroscopy ranges anywhere from art [1] to planetary science missions [2]. The advancement in the use of Raman spectroscopy in Solar System missions, notably in post-mission sample return analysis, requires a spectral library holding the broad range of specimens that could be found in Solar System sources. For this purpose, we have initiated the development of a Raman spectral database (Ramdb) at NASA Ames Research Center. Currently, the database includes experimental and theoretical Raman spectra of PAHs [3, 4], as well as laboratory Raman spectra of amino acids, carbon allotropes, minerals, and analogs relevance to Earth Sciences [5], Exobiology [6], Planetary [7], and Astrochemistry [8] to name just a few examples. Ramdb can be found on the web at www.astrochemistry.org/ramdb, where raw and processed Raman spectra can be downloaded in CSV format. The laboratory Raman spectra are measured using a laser Raman spectrometer (JASCO NRS-5500-532QRI). The Raman instrument is equipped with three excitation lasers, with wavelengths of 405, 532, and 785 nm. A clean silicon substrate is used as the internal standard for wavenumber calibration. Powdered samples were prepared (microscopic >10 um, grounded microscopic < 10 um) on glass slides. Some raw data exhibited a background signal arising as a combination of laser-induced fluorescence from the sample. To correct this background, we developed a Python pipeline that uses open-source Python libraries. Ramdb provides both raw and processed (using Python pipeline) data, which includes tabulated Raman shift transitions and other measurement details. The theoretical Raman band positions of PAHs (pyrene monomers and tetramer clusters) were computed using density functional theory (DFT) with the help of the Gaussian 16 suite of programs [9]. In the near future, Ramdb will serve as a repository of Raman spectral data from Laboratory Astrophysics and Planetary Science experiments involving the irradiation of organic compounds under simulated space and planetary conditions. In addition, online and offline tools will be developed for utilising the database for comparison to the user’s sample.

N Punnakayathil↗

Low mode implosion symmetry sensitivity in low gas-fill NIF cylindrical hohlraums

Achieving an efficient capsule implosion in National Ignition Facility indirect-drive target experiments requires symmetric hohlraum x-ray drive for the duration of the laser pulse. This is commonly achieved using two-sided two-cone laser irradiation of cylindrical hohlraums that, in principle, can zero the time average of all spherical harmonic asymmetry modes <6 as well as the time dependence of the usually dominant mode 2. In practice, experimental evidence indicates that maintaining symmetric drive becomes limited late in the pulse due to the inward expansion of the hohlraum wall and outward expansion of the capsule ablator plasmas impairing the propagation of the inner-cone laser beams. This effect is enhanced in hohlraums employing low gas-fill, now used almost exclusively as these provide the highest performing implosions and reduce Stimulated Brillouin and Raman backscatter losses, since the gas plasma provides less back pressure to limit blow-in of the hohlraum wall and capsule ablator plasmas. In order to understand this dynamic behavior, we combined multi-keV X-ray imaging of the wall and imploded fuel plasmas as we changed a single parameter at a time: hohlraum gas-fill, laser outer cone picket energy, radius of high density carbon capsules used, and laser beam polar and azimuthal pointing geometry. In this work, we developed a physics-based multi-parameter experimental scaling to explain the results that extend prior scalings and compare those to radiation hydrodynamic simulations to develop a more complete picture of how hohlraum, capsule, and laser parameters affect pole vs equator drive symmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Raman signatures from age-dating PuO 2 since last calcination

The self-irradiation of PuO 2 has been shown to affect the attributes of fifteen vibrational bands in the Raman spectrum. The vibrational bands correspond to the Raman allowed vibrational mode T 2g , overtones, defects, and bands from electronic origin. Defects in the crystal lattice from low-calcination temperature and alpha decay origins are responsible for the changes in the band attributes (band position, full-width half maximum (FWHM), intensity). Crystal lattice defects are also responsible for the growth of the defect bands. The temporal behavior of the vibrational bands can be used to estimate the age of the material since last calcination. Laser annealing was used to reset the material to full crystallinity prior to the aging study. 240 PuO 2 , with an alpha decay rate of 3.67 greater than the decay rate of 239 PuO 2 , was primarily used to assess the alpha decay-induced damage within 3 years. The aging study focused on the time-dependent properties of the T 2g band and the growth of defect bands. The FWHM of the T 2g band and the ratio of the areas of the defect bands/T 2g band were measured through a time period in excess of 3 years. The data from this study were found very close to the data describing the temporal evolution of the lattice constant measured with the X-ray diffraction (XRD) technique. The local physical properties of the material measured with Raman spectroscopy and the lattice parameter constant measured with XRD indicates a strong correlation between the two techniques. Although both techniques provide similar age-dating information, in contrast to the few milligram quantities required for XRD, Raman spectroscopy requires a 10 µm diameter PuO 2 particle to provide an estimate of the material age since last calcination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser-induced digital oxidation for copper-based flexible photodetectors

Copper oxide compounds (Cu x O) with bandgaps of 1.3–2.1 eV (CuO) and 2.1–2.6 eV (Cu 2 O) have been investigated as promising p-type semiconducting materials. Cu x O is generally obtained by deposition or thermal oxidation, but those methods are not optimal for flexible substrates. Furthermore, additional patterning steps are required to fabricate devices. In this work, we present an easy, controllable method to fabricate a metal-semiconductor-metal (MSM) photodetector using laser-induced oxidation of a thin Cu film. After laser irradiation, the Cu film is heated under ambient conditions, and this leads to a thermal oxidation reaction, in which Cu oxide is monolithically formed in the Cu film and a Cu-Cu x O-Cu MSM structure is produced. Since the laser offers localized heating, an arbitrary CuxO pattern can be written in the Cu film by spatially controlled heating. In addition, by optimizing the heating time, the laser-induced oxidation can be successfully performed even on a flexible substrate. To study the laser-induced oxidation, we examined the correlation between laser parameters and the oxidation pattern and analyzed the composition using scanning electron microscopy, Raman spectroscopy, and X-ray photoemission spectroscopy. Furthermore, we measured the transient photoresponse and employed scanning photocurrent microscopy to investigate the mechanism of carrier transport behavior.

36 MATERIALS SCIENCE↗

First Results from the Thomson Scattering Diagnostic on the Large Plasma Device

We present the first Thomson scattering measurements of electron density and temperature in the Large Plasma Device (LAPD), a 22 m long magnetized linear plasma device at the University of California Los Angeles (UCLA). The diagnostic spectrally resolves the Doppler shift imparted on light from a frequency-doubled Nd:YAG laser when scattered by plasma electrons. A fiber array coupled to a triple-grating spectrometer is used to obtain high stray light rejection and discriminate the faint scattering signal from a much larger background. In the center of the plasma column, the measured electron density and temperature are about ne≈1.5×1013 cm−3 and Te≈ 3 eV, respectively, depending on the discharge parameters and in good agreement with Langmuir probe data. Optical design considerations to maximize photon count while minimizing alignment sensitivity are discussed in detail and compared to numerical calculations. Raman scattering off of a quartz crystal probe is used for an absolute irradiance calibration of the system.