Search NASA⌕ Search

SEARCH · Search NASA

Results for “Raster”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NEON AOP Survey of Upper East River CO Watersheds: LAZ Files, LiDAR Surface Elevation, Terrain Elevation, and Canopy Height Rasters

Lawrence Berkeley National Laboratory (LBNL) contracted the National Ecological Observatory Network Airborne Observation Platform (NEON AOP) to observe watersheds of interest surrounding Crested Butte, CO with remotely sensed data, including LiDAR. The flight box design encompassed the watersheds, surveying a total area of 334 km2 across 72 lines. The instrument used was an Optech Gemini, with a pulse density of 2-9 pulses m-2 across the study area (see final report document for detailed information (Goulden and Musinsky 2020). These LiDAR data are the primary data that were provided by NEON, and include both LiDAR source data and derived surface products. The source data are contained in 'crbu_laz.zip' and 'classified_point_cloud.zip. 'classified_point_cloud.zip' represents an additional processing level on 'crbu_laz.zip'. The derived products are 'dsm_mosaic_min_phase_me.tif', 'dtm_mosaic_min_phase_me.tif', and 'tch_mosaic_min_phase_me.tif'. These files are raster mosaics of a digital surface elevation model (DSM), digital terrain elevation model (DTM), and a canopy height model (CHM) at 1 m resolution with a height threshold of > 2 m, respectively, in geotiff (.tif) format. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. [UPDATE] On 06/26/2026 the files 'crbu_laz.zip' and 'classified_point_cloud.zip' were replaced with original output files from NEON to address zip file corruption and naming errors. No changes were made to the underlying data. (See Methods Step 2 for details).

2018 NEON and 2025 CHESS Campaigns↗

Gamma-ray raster imaging with robotic data collection. FY18 report

This project has developed an alternative imaging capability for measuring radioactive materials in situ. This approach uses a robotic-mounted gamma-ray detector which can move around an area of interest, sampling the space at a high frequency. By rastering across the area, an image can be created with no collimation and a high efficiency. A regression model was developed to map out material distribution as the robot moves through the environment. An informative path planning algorithm was also developed to maximize the information collected throughout the movement path. The use of a robotic mount allows data collection for long periods of time unattended, and it will also eliminate uncertainties in positioning typically introduced by personnel. This approach will be particularly relevant for gloveboxes, shielded cells, or process piping which may have complex, non-uniform distributions of material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-Ray Raster Imaging with Robotic Data Collection (FY19 Annual Report)

This project has developed an alternative imaging capability for imaging and quantifying radioactive materials in situ. This approach uses a robotic-mounted gamma-ray detector which can move around an area of interest, sampling the space at a high frequency. By rastering across the area, an image can be created with no collimation and a high efficiency. An open-source robotic platform was programed to search an open area, collecting gamma-ray spectra every second. Informative path planning was used to direct the robot to areas of higher dose. Finally, a Bayesian particle filter was used to locate the source with minimal counting statistics. The use of a robotic mount allows data collection for long periods of time unattended, and it will also eliminate uncertainties in positioning typically introduced by personnel. This approach will be particularly relevant for gloveboxes, shielded cells, or process piping which may have complex, non-uniform distributions of material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resultant Cutting Trajectories on Machine Tools with Raster Tool Motion

The formation of the resultant raster trajectories in machine tools are established on the basis of Lissajous figures, taking account of additional workpiece motion for finishing purposes. Kinematic and geometric formulas are obtained for the relative tool and workpiece trajectory with strict kinematic coupling. These formulas are required in practice for abrasive lapping. They permit control of the resultant abrasive-cutting trajectory in finishing the precision planes of the workpiece.

42 ENGINEERING↗

Processed Surface Imagery & Raster Imagery taken onboard TigerShark (U3) UAS

Land-surface orthomosaic imagery derived from the images collected using the Micasense Altum Imager on board the UAS TigerShark (U3) on March 11th, 2021 at an altitude of 2000 ft. The Altum takes images of the land surface across five visible bands and one long wave infrared thermal band. The photogrametry software Agisoft PhotoScan v 1.4 is used to align and stitch the images into a larger composet image using the technique of structure from motion image capture to construct a dense cloud and 3-D model of the surface, which is used to produce a digital elevation model of the terraine surveyed and orthomosaic imagery. This dataset contains the raster calculated orthomosaics of various vegetative indicies, which are used to indicate plant health and land surface characteristics, including Normalized Difference Vegetation Index (NDVI), Green Normalized Difference Vegetation Index (GNDVI), Normalized Difference Water Index (NDWI), surface temperature, and Enhanced_vegetation_index (EVI). These orthomosaics were collected west of the Starkville, MS, airport, and include natural, agricultural, and industrial land coverage. The images have a resolution of 0.2 m/pix.

54 ENVIRONMENTAL SCIENCES↗

An Improved Method of Mitigating Laser Induced Surface Damage Growth in Fused Silica Using a Rastered, Pulsed CO2 Laser

A new method of mitigating (arresting) the growth of large (>200 m diameter and depth) laser induced surface damage on fused silica has been developed that successfully addresses several issues encountered with our previously-reported large site mitigation technique. As in the previous work, a tightly-focused 10.6 {micro}m CO{sub 2} laser spot is scanned over the damage site by galvanometer steering mirrors. In contrast to the previous work, the laser is pulsed instead of CW, with the pulse length and repetition frequency chosen to allow substantial cooling between pulses. This cooling has the important effect of reducing the heat-affected zone capable of supporting thermo-capillary flow from scale lengths on the order of the overall scan pattern to scale lengths on the order of the focused laser spot, thus preventing the formation of a raised rim around the final mitigation site and its consequent down-stream intensification. Other advantages of the new method include lower residual stresses, and improved damage threshold associated with reduced amounts of redeposited material. The raster patterns can be designed to produce specific shapes of the mitigation pit including cones and pyramids. Details of the new technique and its comparison with the previous technique will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

COSMIC: A Regimen of Intensity Modulated Radiation Therapy Plus Dose-Escalated, Raster-Scanned Carbon Ion Boost for Malignant Salivary Gland Tumors: Results of the Prospective Phase 2 Trial

Purpose: To investigate the effect of intensity modulated radiation therapy (IMRT) and dose-escalated carbon ion (C12) therapy in adenoid cystic carcinoma (ACC) and other malignant salivary gland tumors (MSGTs) of the head and neck. Patients and Methods: COSMIC (combined treatment of malignant salivary gland tumors with intensity modulated radiation therapy and carbon ions) is a prospective phase 2 trial of 24 Gy(RBE) C12 followed by 50 Gy IMRT in patients with pathologically confirmed MSGT. The primary endpoint is mucositis Common Terminology Criteria grade 3; the secondary endpoints are locoregional control (LC), progression-free survival (PFS), overall survival (OS), and toxicity. Toxicity was scored according to the Common Terminology Criteria for Adverse Events version 3; treatment response was scored according to Response Evaluation Criteria in Solid Tumors 1.1. Results: Between July 2010 and August 2011, 54 patients were accrued, and 53 were available for evaluation. The median follow-up time was 42 months; patients with microscopically incomplete resections (R1, n=20), gross residual disease (R2, n=17), and inoperable disease (n=16) were included. Eighty-nine percent of patients had ACC, and 57% had T4 tumors. The most common primary sites were paranasal sinus (34%), submandibular gland, and palate. At the completion of radiation therapy, 26% of patients experienced grade 3 mucositis, and 20 patients reported adverse events of the ear (38%). The most common observed late effects were grade 1 xerostomia (49%), hearing impairment (25%, 2% ipsilateral hearing loss), and adverse events of the eye (20%), but no visual impairment or loss of vision. Grade 1 central nervous system necrosis occurred in 6%, and 1 grade 4 ICA hemorrhage without neurologic sequelae. The best response was 54% (complete response/partial remission). At 3 years, the LC, PFS, and OS were 81.9%, 57.9%, and 78.4%, respectively. No difference was found regarding resection status. The most common site of failure was distant (55%). Local relapse was predominantly in field (79%). Conclusion: Treatment was tolerated, with moderate acute and late toxicity. The LC at 3 years was promising. No significant difference could be shown regarding resection status; hence, extensive and mutilating surgical procedures should be rediscussed. Further dose escalation may be limited in view of potential vascular adverse events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-stroke silicon-on-insulator MEMS nanopositioner: Control design for non-raster scan atomic force microscopy

A 2-degree of freedom microelectromechanical systems nanopositioner designed for on-chip atomic force microscopy (AFM) is presented. The device is fabricated using a silicon-on-insulator-based process and is designed as a parallel kinematic mechanism. It contains a central scan table and two sets of electrostatic comb actuators along each orthogonal axis, which provides displacement ranges greater than ±10 μm. The first in-plane resonance modes are located at 1274 Hz and 1286 Hz for the X and Y axes, respectively. To measure lateral displacements of the stage, electrothermal position sensors are incorporated in the design. To facilitate high-speed scans, the highly resonant dynamics of the system are controlled using damping loops in conjunction with internal model controllers that enable accurate tracking of fast sinusoidal set-points. To cancel the effect of sensor drift on controlled displacements, washout controllers are used in the damping loops. The feedback controlled nanopositioner is successfully used to perform several AFM scans in contact mode via a Lissajous scan method with a large scan area of 20 μm × 20 μm. The maximum scan rate demonstrated is 1 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗