Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rated cooling capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

A microchannel shell-and-tube absorber for ammonia-water absorption

A shell-and-tube absorber with microscale geometric features that yields significant volumetric heat duties is investigated. A vertically-oriented baffled shell-and-tube heat exchanger with a tightly packed tube bundle is designed to serve as the absorber for a 10.5 kW nominal cooling capacity absorption chiller. The heat and mass transfer in this absorber is investigated experimentally at operating conditions spanning a wide range of working fluid and coupling fluid flow rates and ambient temperatures. An experimental facility is fabricated to closely simulate the operating conditions in an absorption refrigeration system. Absorption heat duties in the range of 5-15 kW are measured. In addition to operating the absorber in the baseline co-current flow configuration with premixed inlet, fluid ports are provided to enable operation in counter-current flow, where the dilute solution enters from the top and vapor enters from the bottom. The performance of these two flow configurations is compared. A preliminary heat and mass transfer model is developed to quantify the local temperatures, concentrations, and mass flow rates of the solution and vapor streams along the length of the absorber. The model predictions for total heat duty agree with the experimental results within 10% for almost all the data points, with an AAD of ~3.4%. Finally, the results of this study, along with the modeling framework, can guide further development of highly compact and efficient absorbers absorption systems.

42 ENGINEERING↗

Cold Climate Integrated Heat Pump with Energy Storage for Grid-Responsive Control

An air-source integrated heat pump (ASIHP) is a multifunctional unit, capable of space cooling, space heating, and water heating. We developed a packaged cold climate ASIHP, using a multi-stage compressor, capable of working down to -25°C, and providing 100% rated capacity down to -15°C with a heating COP > 2.2. An innovative system configuration and related controls were developed to solve charge balance in the integrated heat pump, smooth charge migration, and mode transition among multiple working modes. Extensive laboratory investigations for individual modes were performed to verify the performance. Its integrated heating capability provides speedy water heating to meet domestic hot water use and store heating energy in a phase change material ceiling/panel. The heating energy storage can be used to shift the load when the electricity price is high. Based on the performance data and a calibrated model from the laboratory testing, we conducted building energy simulations driven by a model predictive control, using EnergyPlus in one U.S. cold climate zone to investigate the grid-responsive control strategy and estimate the utility cost reduction potential.

Shen, Bo↗

Design and analysis of optimal pre-cooling in residential buildings

Existing pre-cooling strategies provide a means of shifting or reducing the peak demand and/or energy cost in residential buildings. However, majority of them are rule-based and therefore may not be optimal in terms of cost saving, leaving room for improvement. In this paper, an integer linear programming problem that accounts for the thermal properties of a specific home, HVAC system capacity, utility rate structure, and weather conditions and makes use of a home thermal model is formulated. This problem determines the HVAC on/off control signal that minimizes the 24-h energy cost while maintaining thermal comfort and calculates the corresponding optimal indoor air temperature. The model is constructed using home thermal properties identified via data training in real-time. Through simulation, the energy performance of the proposed optimal pre-cooling strategy is investigated and compared with three rule-based operation strategies from the literature. It is found that the optimal strategy requires the least energy consumption without sacrificing thermal comfort. The superb energy performance of the optimal strategy is attributed to a longer runtime of the HVAC system in cool outdoor air conditions and to the elimination of deadband in HVAC operation, which is required by the rule-based strategies, to allow the indoor air temperature to stay near the thermal comfort upper bound as much as possible. In terms of energy cost, the rule-based operation strategies require 3.52, 1.90, and 2.79, respectively, while the optimal strategy only requires 1.52. These figures represent a saving of 56.82%, 20.00%, and 45.52%, respectively. The results suggest that the optimal strategy is indeed significantly more effective than the existing rule-based operation strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of hydrogen isotope on plasma impedance and thermal pinching induced by single aerosol droplets injected into an inductively coupled plasma

The mass of the hydrogen isotope in micrometer-sized aqueous droplets introduced into an ICP has been found to affect the degree of resulting plasma perturbation. Studied plasma perturbations include local plasma cooling, plasma shrinkage due to thermal pinching, and changes in plasma impedance. The local cooling effect caused by a vaporizing aerosol droplet was found to be similar between H 2 O and D 2 O. This finding is likely a result of the similar heat capacities and vaporization rates of H 2 O and D 2 O droplets and of the comparable thermal conductivities and dissociation kinetics of H 2 O and D 2 O vapor. In contrast, a clear isotope effect was observed for plasma shrinkage and impedance change, with H 2 O causing a considerably stronger effect. Plasma shrinkage, gauged by the reduction in Ar emission at the edge of the plasma, was detected at all observation heights within the load-coil region, with D 2 O droplets causing as much as 30% less of an effect than H 2 O. Likewise, D 2 O droplets induce significantly less change in plasma impedance than H 2 O droplets. Depending on experimental conditions and the probing method, changes in plasma impedance caused by monodisperse D 2 O droplets were only 52%–80% that of H 2 O. The lower influence on plasma shrinkage and impedance change for D 2 O droplets is believed to be related to the much lower thermal conductivity of atomic deuterium, around 70% that of atomic hydrogen (protium). The time required for the plasma impedance to return to its original steady-state value was comparatively long (~10 ms) and similar for H 2 O and D 2 O droplets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal-Hydrological-Mechanical Modelling of Stockton University Reservoir Cooling System, Fine Scale Stress Test Modelling

Mesh, properties, initial conditions, injection/withdrawal rates for modelling thermal, hydrological, and mechanical effects of fluid injection to and withdrawal from ground for Stockton University reservoir cooling system (aquifer storage cooling system), Galloway, New Jersey, for unscheduled two hour injection at 133 % designed capacity, on fine scale grid, with some results. Second simulation of J.T. Smith, E. Sonnenthal, P. Dobson, P. Nico, and M. Worthington, 2021. Thermal-hydrological-mechanical modeling of Stockton University reservoir cooling system, Proceedings of the 46th Workshop on Geothermal Reservoir Engineering, Stanford University, SGP-TR-218, from which Figures 6-9, pertain.

15 GEOTHERMAL ENERGY↗

Assessing parallel path cooling tower performance via artificial neural networks

Real-time monitoring of a research nuclear reactor, a system in which all generated power is dissipated to the environment, can be performed via analysis of the heat rejection from the cooling system. Given an inlet water temperature and flow rate, the reactor power can be well-approximated from the outlet water temperature; however, the instrumentation to measure outlet conditions may not be robust or accurate. If we know how a cooling tower performs from historical data, but cannot measure the outlet temperature, a mathematical representation of the system can be inverted to obtain the outlet water temperature that describes the cooling capacity. Unfortunately, model inversion processes are computationally expensive. To address this, an artificial neural network (ANN) is implemented to assess the performance of a multi-cell cooling tower for a nuclear reactor. This approach leverages the Merkel model to obtain an extensive data set describing performance of the cooling tower cells throughout a wide array of potential operating conditions. The Merkel model is expressed as a function of four parameters: the inlet and outlet water temperatures, inlet air wet bulb temperature, and ratio of liquid-to-gas mass flow rates (L/G), which together provide a non-dimensional number indicative of cooling tower performance, called the Merkel integral. Computing a 4-dimensional data structure that describes finite combinations of the Merkel integral, an inverse model is then generated using an ANN to determine the cell outlet water temperature from the other three model parameters along with the computed Merkel integral. Compared to traditional model inversion methods, the ANN reduces the computational time by approximately 4 orders of magnitude, with effectively no sacrifice to solution accuracy, and could be applied for different cooling towers in the event the performance curve is known. Finally, three use cases of the ANN are then reviewed: (1) determining the cell outlet water temperatures when gas flow at rated conditions (GFRC) is known, (2) performing the prior case without knowledge of the GRFC, and (3) assessing performance differences between the individual tower cells.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Data-driven Approach for Predicting Nepheline Crystallization in High-Level Waste Glasses

High-level waste (HLW) glasses with high aluminum content are prone to nepheline crystallization during the slow canister cooling that is experienced during large-scale production. Due to its detrimental effects on glass durability, nepheline precipitation must be avoided; however, developing robust, predictive models for nepheline crystallization behavior in HLW glasses is difficult due to their compositional complexity. Using overly conservative constraints to predict nepheline formation can limit the waste loading to lower than the achievable capacity. In this study, a robust data-driven model using five compositional features has been developed to predict nepheline formation. The analysis of the model and the data show that there is an overlap, instead of a distinct compositional boundary, between glasses that form and do not form nepheline. As a result, the model’s predictive accuracy is not the same throughout the feature space and instead is dependent on the location of the glass composition in the dimensionally reduced feature space.

Sargin, Irmak↗

Exploring the dependence of gas cooling and heating functions on the incident radiation field with machine learning

ABSTRACT Gas cooling and heating functions play a crucial role in galaxy formation. But, it is computationally expensive to exactly compute these functions in the presence of an incident radiation field. These computations can be greatly sped up by using interpolation tables of pre-computed values, at the expense of making significant and sometimes even unjustified approximations. Here, we explore the capacity of machine learning to approximate cooling and heating functions with a generalized radiation field. Specifically, we use the machine learning algorithm XGBoost to predict cooling and heating functions calculated with the photoionization code cloudy at fixed metallicity, using different combinations of photoionization rates as features. We perform a constrained quadratic fit in metallicity to enable a fair comparison with traditional interpolation methods at arbitrary metallicity. We consider the relative importance of various photoionization rates through both a principal component analysis (PCA) and calculation of SHapley Additive exPlanation (shap) values for our XGBoost models. We use feature importance information to select different subsets of rates to use in model training. Our XGBoost models outperform a traditional interpolation approach at each fixed metallicity, regardless of feature selection. At arbitrary metallicity, we are able to reduce the frequency of the largest cooling and heating function errors compared to an interpolation table. We find that the primary bottleneck to increasing accuracy lies in accurately capturing the metallicity dependence. This study demonstrates the potential of machine learning methods such as XGBoost to capture the non-linear behaviour of cooling and heating functions.

79 ASTRONOMY AND ASTROPHYSICS↗

Hydrogen uptake in graphite matrix at high temperature

Tritium management is a critical challenge for the next generation of nuclear reactors, such as Fluoride Salt Cooled High Temperature Reactors (FHRs) and High Temperature Gas-cooled Reactors (HTGRs), due to the higher production rate (up to 10,000 times) than conventional Light Water Reactors (LWRs). Graphitic materials employed as moderator, reflector, and fuel pebbles offer a potential pathway for tritium recovery by serving as a sink for tritium. Prediction of uptake capacity under reactor relevant conditions remains a challenge due to a lack of low partial pressure data and significant inter-grade variability of graphite. This study addresses these gaps by providing a comprehensive characterization of hydrogen (as a tritium surrogate) uptake and release behavior in the A3-3 graphite matrix (GM) used in fuel pebbles. Uptake measurements are performed at reactor relevant temperatures of 600- 800 °C, 1-200 Torr hydrogen pressure, and 15-120 min equilibration time, followed by thermal desorption spectroscopy up to 1100 °C. Uptake experiments at different equilibration times demonstrate the role of kinetics in hydrogen uptake, which can be modeled as a diffusion-with-trapping process. In the thermodynamics limit, the Sips adsorption model is shown to capture the uptake in A3-3 GM well. Our campaign provides a set of new results for hydrogen uptake in A3-3, including limiting uptake capacity at 600 °C, apparent diffusion coefficient at 600 °C, and the first estimates of the FHR/HTGR relevant (600 °C, 20 Pa partial pressure) equilibrium uptake capacity and time to saturation. Desorption data highlights a new site for hydrogen uptake, not observed in nuclear graphite, which we attribute to the non-graphitized binder. Using the Kissinger method, we estimate activation energy for release from the desorption peaks, confirming the activation energy for release from the basal planes and providing the first estimate for the activation energy of release from the binder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding Melting and Freezing/Solidification and the Associated Effects on Heat Transfer

Phase change (solid/liquid or liquid/vapor) is a process that enables a large heat transfer capacity for a broad range of engineering applications, such as steam generators, condensers, thermal energy storage, thermosyphons, and heat pipes. Water has been the most usable phase-change cooling medium. Advanced applications are proposing alkali metals (e.g., sodium, potassium, lithium) to increase the total heat transfer rate for moderate and high-temperature applications. Sodium and potassium have the advantage of relatively low melting temperatures (98 and 64°C, respectively) make them suitable for high-temperature applications (700–1100 K). At too high of temperatures (above 1200 K), lithium is an excellent choice as a working fluid because of its high latent heat vaporization and high-surface tension. The low vapor pressure of alkali metals makes them candidates for closed spaces applications, such as thermosyphons and heat pipes. Lithium has the lowest vapor pressure than potassium and sodium, which can work at a much higher temperature without over-pressurizing the container.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power

Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.

capacity expansion model↗

Stochastic Thermo-Hydro Modeling and Neural Network Surrogate Development for Thermal Resource Assessment of the Galleries-to-Calories Geobattery

The Galleries-to-Calories Geobattery concept explores the use of abandoned coal mine workings for large-scale thermal energy transport and storage. The system involves injecting waste heat from a supercomputing facility into flooded mine galleries, where groundwater flow can store and transport thermal energy for potential recovery in downgradient district heating and cooling applications. To evaluate the feasibility and performance of the Geobattery under geological and operational uncertainty, we developed a suite of stochastic thermo-hydrological (TH) simulations using Monte Carlo sampling of key uncertain parameters (e.g., permeability, porosity, thermal conductivity, specific heat capacity) and operating conditions (e.g., injection rate, injection temperature). Results identified injection rate and temperature as the most influential parameters governing thermal front propagation, while the geometry of the room-and-pillar structure played a critical role in directing the extent and orientation of thermal advancement. Optimal combinations of material properties for maximizing heat recovery were also determined. To address the high computational cost of coupled-process stochastic modeling, we trained a neural network surrogate model on 24,000 physics-based realizations, achieving an R² > 0.99 and MAE < 0.1 for temperature predictions at monitoring locations. This surrogate enabled an additional 100,000 realizations for global sensitivity analysis and probabilistic thermal resource assessment. The integrated stochastic physics–surrogate modeling framework offers a computationally efficient tool for quantifying uncertainty, identifying key drivers, and informing early-stage design decisions for Geobattery systems.

15 - GEOTHERMAL ENERGY↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water desalination through the dewpoint evaporative system

This paper presents the first numerical analysis of a novel Dew Point Desalination unit (DPD), which utilizes the phenomenon of the evaporative cooling process to minimize energy consumption. The proposed solution is based on a modular structure, which allows it to obtain any required water production capacity. The analyses for various operational parameters and various climatic conditions are based on the numerical simulations conducted using a validated mathematical model. The system performance was described with different factors, including specific energy consumption (SEC) and daily water production rate respected to 1 m^3*s^-1 of passing air stream (DWP). It is shown that the DPD system can operate in almost every climate zone, and the desalinated water production consumes less than 1.5 kWh*m^-3 of electric energy It is noted the best performance of the DPD system is achieved in the semi-arid, desert and subtropical climate zones. In these climate zones, the 2-stage DPD system allows the production of desalinated water with an electric energy consumption SEC lower than 0.5 kWh*m^-3. The additional benefit of the DPD system is its modularity. The presented DPD system stands as a module, that can be multiplied as needed to achieve the desired size of the desalination plant.

Desalination↗