Lower Snake River Dams Contribution to Grid Services

Hydroelectric generation and water storage have long been components of the clean energy mix, providing both reliable steady output and operational flexibility. As variable renewable energy sources such as wind and solar increasingly replace traditional generation, the role of all flexible resources—including hydropower—in balancing supply and demand continues to evolve. This study examined the contribution of the Lower Snake River (LSR) Dam plants to Bonneville Power Administration grid services in maintaining power system reliability within the Western Interconnection. By analyzing publicly available data, the study evaluated various reliability services through performance metrics including energy capacity, balancing and ramping, voltage and reactive power support, frequency response, and transmission impact. Results indicated that the LSR plants deliver services as expected based on their size, contributing to the balancing process, ramping capabilities, and operational reserves, particularly during peak load conditions and weather events, while also providing measurable frequency and voltage support to the grid.

13 HYDRO ENERGY↗

Probabilistic Deliverability Assessment of Distributed Energy Resources via Scenario-Based AC Optimal Power Flow

As electric grids decarbonize and distributed energy resources (DERs) become increasingly prevalent, interconnection assessments must evolve to reflect operational variability and control flexibility. This paper highlights key modeling limitations observed in practice and reviews approaches for modeling uncertainty. It then introduces a Probabilistic Deliverability Assessment (PDA) framework designed to complement and extend existing procedures. The framework integrates scenario-based AC optimal power flow (AC OPF), corrective dispatch, and optional multi-temporal constraints. Together, these form a structured methodology for quantifying DER utilization, deliverability, and reliability under uncertainty in load, generation, and topology. Outputs include interpretable metrics with confidence intervals that inform siting decisions and evaluate compliance with reliability thresholds across sampled operating conditions. A case study on Puerto Rico’s publicly available bulk power system model demonstrates the framework’s application using minimal input data, consistent with current interconnection practice. Across staged fossil generation retirements, the PDA identifies high-value DER sites and regions requiring additional reactive power support. Results are presented through mean dispatch signals, reliability metrics, and geospatial visualizations, demonstrating how the framework provides transparent, data-driven siting recommendations. The framework’s modular design supports incremental adoption within existing workflows, encouraging broader use of AC OPF in interconnection and planning contexts.

14 SOLAR ENERGY↗

Enhancing Synchronous Condenser Operation of Hydrogenerators

Hydropower plants are sometimes dispatched below capacity or even shut down to meet water regulations. These can temporarily be repurposed to operate as synchronous condensers. To enable this capability, this paper proposes a design that allows hydrogenerators to safely operate as synchronous condensers, providing fast voltage and reactive power support under both normal and boost conditions. The proposed design integrates capability curves with hydrogenerators’ excitation systems through modifications using proposed MVA-field current curve, current controller, and limiter. The design is implemented locally at the machine for rapid response. Simulation results demonstrate the effectiveness of the proposed design and using hydrogenerators as synchronous condensers in power grids.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗

Sensitivity-Based Reactive Power Dispatch of DERs to Support Transmission Grid During Emergency

This paper proposes a TSO-DSO framework including DER set-point dispatch using sensitivity analysis. We address all three steps of TSO-DSO integration stating by estimating the capability curve of an unbalanced distribution system and then modeling of capability curve on the transmission side grid and estimating the reactive power needed from DSO during emergencies, and ending by dispatching the requested reactive power from TSO. The proposed interaction framework is tested on an IEEE 37-node distribution network connected to IEEE 9 bus transmission system. The simulation shows that using sensitivity-based dispatch would reduce the number of communication signals between DERs and DSO and that can decrease the risk of communication contingency.

Alkhonain, Ahmed↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

This paper performs research on predicting Photovoltaic (PV) inverters reliability and lifetime based on thermal cycling. Thermal cycling is considered the most important stressors in an inverter system. In order to achieve this, a detailed electro-thermal model of the PV inverter will be developed along with their controllers capable of providing voltage support through reactive power. An in-house inverter was built, and a PV inverter model was developed to match the physical inverter. The PV inverter electrothermal model was validated for different ambient temperatures to match the in-house inverter hardware. The in-house inverter was placed inside a thermal chamber to emulate different ambient temperatures and their losses and temperature rises within the system were measured. After the validation of the model, a reduced order model of the inverter will be implemented to translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The junction temperature data will be used to identify the reliability indices and hence predict the useful lifetime of the inverter system. Along with the model to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The key observation in this paper shows that lifetime of the inverter decreases as the operating power factor moves away from unity.

14 SOLAR ENERGY↗

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of DER Voltage Regulation Technologies Using Real-Time Simulations

Grid operators are now considering using distributed energy resources (DERs) to provide distribution voltage regulation rather than installing costly voltage regulation hardware. DER devices include multiple adjustable reactive power control functions, so grid operators have the difficult decision of selecting the best operating mode and settings for the DER. In this work, we develop a novel state estimation-based particle swarm optimization (PSO) for distribution voltage regulation using DER-reactive power setpoints and establish a methodology to validate and compare it against alternative DER control technologies (volt–VAR (VV), extremum seeking control (ESC)) in increasingly higher fidelity environments. Distribution system real-time simulations with virtualized and power hardware-in-the-loop (PHIL)-interfaced DER equipment were run to evaluate the implementations and select the best voltage regulation technique. Each method improved the distribution system voltage profile; VV did not reach the global optimum but the PSO and ESC methods optimized the reactive power contributions of multiple DER devices to approach the optimal solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peer-to-peer communication control for resilient operations of networked cyberphysical systems

This report includes two main accomplishments of the peer-to-peer communication control for resilient operation of networked microgrids project in FY24, which include a scheme for cyberattack-aware coordination of networked microgrids for supporting voltages of bulk power systems and a scheme for price signal-based operations of EV-rich networked microgrids with mixed ownership. First, the cyberattack-aware scheme enables networked microgrids to distributedly determine the amount of reactive power injection to support the voltage of bulk power system (BPS) in a fair manner. In this scheme, a risk-informed algorithm is presented to generate the peer-to- peer (P2P) communication graph with minimal risk of attack on communication links. To deal with cyberattacks on MG controllers, the resilient consensus algorithm (CA) is utilized for MG controllers to robustly estimate the total reactive power headroom, from which the MGs can accurately provide the needed amount of reactive power injection for supporting the voltage of BPS. The CA implementation and performance within the P2P communication framework are demonstrated on the IEEE 39-bus system with 6 microgrids contained in the distribution feeder under different cyberattack scenarios. Second, the price-based scheme enables the usage of the real-time price signal for the operations of electric vehicle (EV)-rich networked-microgrids with mixed ownership, in which not all the microgrids can communicate with the distribution system operator (DSO). In this scheme, a max consensus is introduced to enable the real-time price signal to be propagated from the DSO to all the microgrids, from which each microgrid controller will manage the DERs to balance the load demand and the power injection from the EV charging stations within its microgrid. Numerical results over one day with 288 slots of 5-minute intervals on the modified 123-node test feeder including 3 microgrids with high penetration of EV are presented to evaluate how the price signal affects the operations of networked microgrids under different charging strategies of the EV charging stations. The result indicates that our proposed EVCS (dis)charging strategy, which leverages the flexibility of EVs to support the grid through discharging during peak demand, proves to be a cost-effective solution that reduces operational costs while improving the social welfare of EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introduction to Grid Forming Inverters: A Key to Transforming our Power Grid [Slides]

A grid-forming (GFM) inverter-based resource (IBR) controls maintain an internal voltage phasor that is constant or nearly constant in the sub-transient to transient time frame. This definition means that the GFM IBR will nearly immediately respond to changes in the external system and attempt to maintain IBR control during challenging network conditions to maintain grid stability. In GFM IBR, the voltage phasor is controlled to maintain synchronism with other devices in the grid while regulating the active and reactive power appropriately to support the grid. This contrasts with conventional GFL IBR controls wherein immediately after a disturbance (0-5 cycles), within the normal operating range of voltage, the output current phasor magnitude and angle remain unchanged, and the current phasor begins changing only within the transient time frame (tens of cycles) to strictly control the active and reactive power being injected into the network. This presentation gives an introduction to GFM IBR and presents the current state of the art in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

Stability Impact of IEEE 1547 Operational Mode Changes Under High DER Penetration in the Presence of Cyber Adversary

The IEEE 1547 standard addresses the integration of Distributed Energy Resources (DER) into Area Electric Power Systems (AEPS). The updated standard, released in 2018 with revisions ongoing, specifies the need for more flexible settings, requiring the DER to remain connected during certain disturbances and provide voltage support via active and reactive power modes. With these increased capabilities comes increased risks, and our analysis of the standard has produced potential settings combinations, which, while allowable under the standard, may actually create instability. This contradicts the main purpose of the revised standard. Since the DER must support a communication interface through which the AEPS operator can change settings, adversarial mode changes are possible via a cyberattack. This concern is heightened as DER penetration increases, where under a reasonable threat model, an attacker could affect multiple DER simultaneously. We have conducted a simulation analysis of potentially adverse combinations of mode change and ridethrough parameters on a hypothetical AEPS with varying degrees of DER penetration. We conclude that certain adverse mode changes, whether through error or cyberattack, can lead to unstable conditions with DER penetrations as low as 24% of the AEPS system capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GA-Based Voltage Optimization of Distribution Feeder with High-Penetration of DERs Using Megawatt-Scale Units

In this paper, genetic algorithm (GA)-based voltage optimization of a modified IEEE-34 node distribution feeder with high penetration of distributed energy resources (DERs) is proposed using two megawatt-scale reactive power sources. Traditional voltage support units present in distribution grids are not suitable for DER-rich feeders, while voltage support using small-scale DERs present in the feeder requires considerable communication effort to reach a global solution. In this work, two megawatt-scale units are placed to improve the voltage profile across the IEEE 34-node feeder, which has been modified to include several PV units and an energy storage unit. The megawatt-scale units are optimized using GA for fast and accurate operation. The performance of the proposed scheme is verified using simulation results with a multi-platform setup where the modified IEEE-34 node feeder is modeled in OpenDSS while the GA optimization scheme is programmed in MATLAB.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Support With PV Inverters in Low-Voltage Distribution Networks: An Overview

Large solar photovoltaic (PV) penetration using inverters in low voltage (LV) distribution networks may pose several challenges, such as reverse power flow and voltage rise situations. These challenges will eventually force grid operators to carry out grid reinforcement to ensure continued safe and reliable operations. However, smart inverters with reactive power control capability enable PV systems to support voltage quality in the distribution network better. Here, this paper gives an overview of the current state-of-the-art control strategies for handling voltage problems through PV inverters and other devices. In addition, the (control) technical issues of PV systems integrated into the LV distribution network are considered from a control point of view. By comparing the control issues of PV integration into the grid, the paper aims to help distribution system operators to expand the volume of PV generation in the distribution system in an efficient and safe manner. Additionally, it will help control engineers and researchers select proper control strategies for PV systems as well as other distributed renewable sources.

42 ENGINEERING↗

GRIDAPPSD/distopf (33583-E)

DistOPF is an open-source Python package providing a three-phase, asymmetric optimal power flow (OPF) tool specifically designed for distribution systems. The key inventive features include: - Asymmetrical 3-phase OPF modeling for distribution systems with unbalanced phases - Comprehensive control optimization supporting both active (P) and reactive (Q) power control variables - Built-in visualization and validation tools - Standard test system benchmarking platform for algorithm development and comparison - Modular CSV-based input system using Pandas DataFrames for flexible model specification - Standard power distribution model importer enabling direct conversion from CIM and OpenDSS format to optimization-ready models - Multiple solve interface compatibility (PYOMO, CVXPY, SciPy) with automatic solver selection based on problem type

Gray, Nathan [Pacific Northwest National Laborator↗

Model predictive control for voltage restoration in microgrids using temporal logic specifications

Power system operation will encounter numerous voltage variabilities as the proliferation of renewable energy continues. Real-time monitoring and communication technologies can potentially improve voltage stability by enabling the rapid detection of voltage deviations and the implementation of corrective actions. These corrective actions will only be effective in restoring stability if they are chosen in a timely and scalable manner. This paper considers the problem of power systems’ load voltage control in order to simultaneously address both magnitude and time voltage specifications. In order to comply with grid codes and avoid unnecessary relay protection actions, a model predictive control (MPC)-based control strategy employing temporal logic specifications (TLSs) is proposed. The TLSs strategy is introduced as a formalism to control the voltage variation at a critical load bus against operational bounds over time. The control objective is to schedule optimal control input signals from the available supportive energy storage systems, which provide reactive power injections, leading to satisfying the specified finite-time restoration described by the TLSs with minimal control efforts. The simulation results display that the TLSs strategy for power systems’ voltage control synthesis is extremely significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review of Power System Support Functions for Inverter-Based Distributed Energy Resources - Standards, Control Algorithms, and Trends

Penetration of renewable energy in power systems has been increasing in the past decades in response to increased global electricity demand and concerns for the environment. Distributed energy resources (DERs) based on renewables have experienced rapid growth thanks to the incentive programs and broad-based participation. With the growing prevalence of DERs, the risk of grid instability and vulnerability increases due to the intermittent nature of renewable energy. At the same time, the voltage and frequency deviation problems emerge more often when the reverse power flow occurs under supply-demand imbalance in distributed power systems. Standards and grid codes have been issued for DER inverters to interconnect with the distribution grid. The updated standard and grid codes expect DERs to provide a variety of power system support functions in order to incorporate higher DER penetration and to maximize DER value to the grid. This paper provides an overview of the power system support functions from renewable DER inverters, which are categorized as: voltage regulation by active/reactive power control, frequency regulation by active power control, voltage ride-through, and frequency ride-through. The benefits and drawbacks of each algorithm are presented and compared with its predecessor, manifesting the logic in the evolution of the algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Coordination of Networked Microgrids for Voltage Support in Bulk Power Grids

The increasing deployment of distributed energy resources (DERs) and microgrids (MGs) in power distribution systems has enabled the adjustment of reactive power consumption as seen at the substation, which can be used to provide voltage support for the bulk power system (BPS). Leveraging this new capability will provide greater resiliency to the power system as a whole. Here, the goal of this paper is to develop and compare three different algorithms, namely distributed optimal power flow, distributed consensus algorithm, and fully decentralized collaborative autonomy for unbalanced distribution systems for microgrid coordination. These algorithms use networked MGs to support the BPS voltage when a contingency at the bulk grid results in abnormally low voltages, which may be a precursor to voltage collapse. Our comparative analysis includes both qualitative and quantitative assessments of the three algorithms and a discussion of the trade-offs between the decentralized and distributed methods in normal and disrupted conditions. Each algorithm was evaluated on the modified IEEE 13-bus system and a real power distribution system at Chattanooga, Tennessee, that encompasses more than 4500 buses. Each algorithms excels differently and may be suited for different scenarios depending on the condition, operations, and priorities of the power and communication systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗