Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reactor Core Isolation Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Simulation of Thermal Stratification in BWR Suppression Pools with One Dimensional Modeling Method

The suppression pool in a boiling water reactor (BWR) plant not only is the major heat sink within the containment system, but also provides the major emergency cooling water for the reactor core. In several accident scenarios, such as a loss-of-coolant accident and extended station blackout, thermal stratification tends to form in the pool after the initial rapid venting stage. Accurately predicting the pool stratification phenomenon is important because it affects the peak containment pressure; the pool temperature distribution also affects the NPSHa (available net positive suction head) and therefore the performance of the Emergency Core Cooling System and Reactor Core Isolation Cooling System pumps that draw cooling water back to the core. Current safety analysis codes use zero dimensional (0-D) lumped parameter models to calculate the energy and mass balance in the pool; therefore, they have large uncertainties in the prediction of scenarios in which stratification and mixing are important. While three-dimensional (3-D) computational fluid dynamics (CFD) methods can be used to analyze realistic 3-D configurations, these methods normally require very fine grid resolution to resolve thin substructures such as jets and wall boundaries, resulting in a long simulation time. For mixing in stably stratified large enclosures, the BMIX++ code (Berkeley mechanistic MIXing code in C++) has been developed to implement a highly efficient analysis method for stratification where the ambient fluid volume is represented by one-dimensional (1-D) transient partial differential equations and substructures (such as free or wall jets) are modeled with 1-D integral models. This allows very large reductions in computational effort compared to multi-dimensional CFD modeling. One heat-up experiment performed at the Finland POOLEX facility, which was designed to study phenomena relevant to Nordic design BWR suppression pool including thermal stratification and mixing, is used for validation. Comparisons between the BMIX++, GOTHIC, and CFD calculations against the POOLEX experimental data are discussed in detail.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Terry Turbopump Analytical Modeling Efforts in Fiscal Year 2018. Progress Report

This document details the computational fluid dynamic and system-level modeling, including a mechanistic representation of a Terry turbopump. Until this recent effort, data and modeling results show that a Terry turbine, flowing air (or steam) at a certain rate, can develop the same power at two very different speeds, and has large implications with respect to understanding how a boiling water reactor's reactor core isolation cooling system or a pressurized water reactor turbine driven auxiliary feedwater system would respond to a loss of electrical power for Terry turbine speed governing. This work has provided insights in modeling uncertainties and provides confirmation for experimental efforts for the Terry turbopump expanded operating band being conducted at Texas A&M University.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Core Status of Fukushima Daiichi Nuclear Power Plant

There were some events and phenomena that occurred which have been deemed specific to the Fukushima Daiichi NPP. The primary issues were as follows: - Direct steam leakage from the reactor pressure vessels (RPVs) to the dry-wells through the gaskets of the safety relief valves and/or due to creep damage of the main steam line, and damage of the in-core monitor guide tubes due to buckling. - Direct corium leakage from the RPVs to the pedestal floors through the melt portions of the in-core monitor housings. - Alternative water injection by the fire trucks with large amount of leakages through the branch lines. - Partial load operation of the Reactor Core Isolation Cooling system and the High Pressure Coolant Injection system. - Gas leakage from the primary containment vessels to the reactor buildings due to over pressure than the design maximum value. - Thermal stratification in the suppression pool resulting in incomplete steam condensation in the pool. The accident progressions were analyzed with the newly developed physical models for the above issues. And also considering the qualitatively estimated core status based on the plant parameters measured after the accident, the current core status was assessed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Two-zone stratified wetwell model development and implementation for RELAP-7

The Reactor Core Isolation Cooling (RCIC) system consists of a turbine, pump and wetwell and is used in many US Boiling Water Reactors (BWRs) as an important heat removal system. The wetwell is a major heat sink within containment. Experimental investigations have shown that thermal stratification may occur in the wetwell during RCIC operation. Current systems-level analysis codes lack stratified wetwell models. Here, this paper describes the development of a stratified wetwell model for the RELAP-7 code. This paper uses a simple two-zone model for the wetwell water that can capture thermal stratification. This model assumes that a buoyant plume transports heat and mass from the steam injection site to the upper water zone. The buoyant plume assumption requires that steam is injected at a low enough rate so it adds negligible momentum. Model validation against experimental data shows similar trends of temperature field development in the suppression pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi-phase model development to assess RCIC system capabilities under severe accident conditions

The Reactor Core Isolation Cooling (RCIC) System is a safety-related system that provides makeup water for core cooling of some Boiling Water Reactors (BWRs) with a Mark I containment. The RCIC System consists of a steam-driven Terry turbine that powers a centrifugal, multi-stage pump for providing water to the reactor pressure vessel. The Fukushima Dai-ichi accidents demonstrated that the RCIC System can play an important role under accident conditions in removing core decay heat. The unexpectedly sustained, good performance of the RCIC System in the Fukushima reactor demonstrates, firstly, that its capabilities are not well understood, and secondly, that the system has high potential for extended core cooling in accident scenarios. Better understanding and analysis tools would allow for more options to cope with a severe accident situation and to reduce the consequences. The objectives of this project were to develop physics-based models of the RCIC System, incorporate them into a multi-phase code and validate the models. This Final Technical Report details the progress throughout the project duration and the accomplishments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analytical Models for Terry Turbine Nozzle

As part of the efforts to understand the unexpected 'self-regulating' mode of the RCIC (Reactor Core Isolation Cooling) systems in Fukushima accidents and extend BWR RCIC and PWR AFW (Auxiliary Feed Water) operational range and flexibility, mechanistic models for the Terry turbine should be developed and implemented in reactor system analysis or severe accident codes. The Terry turbine has been used for all the BWR RCIC systems and for PWR AFW (Auxiliary Feed Water) systems. The Terry turbine is essentially a solid cylindrical wheel with multiple machined semi-circular 'buckets' that are shaped into the body of the wheel. Fixed nozzles and reversing chambers surround the wheel inside the turbine casing. High pressure steam is accelerated to supersonic flow inside the turbine nozzle. The kinetic energy is then converted to shaft work by the impulse force on the turbine buckets. A Fully implicit and strongly coupled RCIC system model has been developed in the RELAP-7 code and used for simplified BWR SBO (Station Black-Out) simulations in the past. In this model, a generic turbine model was used to conserve mass and energy while turbine operation characteristic curves were used to obtain non-dimensional mass flow rate and thermal efficiency. This model could be used for simulating RCIC off-design behavior if off-design operation characteristic curves were available. However, No such curves currently exist for the Terry turbine system due to its unique pure impulse design. A set of mechanistic Terry turbine models suitable for system code implementation has recently been developed by Sandia National Labs. In the Sandia model, the turbine bucket inlet velocity is provided according to a reduced-order model which was obtained from a large number of CFD simulations. In this paper, we propose an alternative method, using an under-expanded jet model to obtain the velocity and thermodynamic conditions for the turbine bucket inlet. These sets of analytical models are simple and generic, and suitable for use in system analysis codes. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP-7 Simulation Resolving an SBO Scenario on a Simplified Geometry of a BWR

The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). RELAP-7 will become the main reactor systems toolkit for the Risk-Informed Safety Margin Characterization Pathway of the Light Water Reactor Sustainability Program and the next generation tool in the RELAP reactor safety/systems analysis application series (i.e., the replacement for RELAP5). The code is being developed based on Idaho National Laboratory’s modern scientific software development framework – MOOSE (the Multi-Physics Object-Oriented Simulation Environment). During Fiscal Year 2013, a number of physical components with two-phase flow capability have been developed to support the simplified boiling water reactor (BWR) station blackout analyses. The case selected for demonstration calculation is built from the specifications documented in an Organization for Economic Cooperation and Development benchmark problem for BWR turbine trip analysis. The reference design for the benchmark problem was from the Peach Bottom-2 nuclear station, which is a General Electric BWR-4 design. The demonstration case includes the major components for the primary system of a BWR, as well as the safety system components for reactor core isolation cooling (RCIC) and the wet well of a BWR containment. The case was initially run to steady-state with RELAP-7. The station blackout transient simulations were subsequently initiated by using the INL-developed RAVEN code. Two scenarios for the station blackout simulations have been considered. Scenario I represents an extreme station blackout accident with no safety injection functioning. The reactor core could experience dry out fairly quickly with this scenario. Scenario II represents a more probable station blackout accident progression with the RCIC system functioning. In this scenario, the RCIC system is fully coupled with the reactor primary system and the safety injection to provide makeup cooling water to the reactor core from the suppression pool is dynamically simulated. With the RCIC system functioning, the core dry out is significantly postponed when compared to the results from Scenario I. This fully coupled RCIC system simulation capability represents the first-of-a-kind simulation capability. Sensitivity studies have also been carried out to study the effect of RCIC control strategy with varying core makeup cooling water mass flow rates. The next stage of development will be to demonstrate more refined BWR station blackout analyses with more realistic geometries, to be reported in the next demonstration simulation report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TRACE and TRAC-BF1 benchmark against Leibstadt plant data during the event inadvertent opening of relief valves

In framework of introducing TRACE code to transient analyses system codes for Leibstadt Power Plant (KKL), a conversion process of existing TRAC-BF1 model to TRACE has been started within KKL. In the first step, TRACE thermal-hydraulic model for KKL has been developed based on existing TRAC-BF1 model. In order to assess the code models a simulation of plant transient event is required. In this matter simulations of inadvertent opening of 8 relief valves event have been performed. The event occurs at KKL during normal operation, and it started when 8 relief valves open resulting in depressurization of the Reactor Pressure Vessel (RPV). The reactor was shutdown safely by SCRAM at low level. The high pressure core spray (HPCS) and the reactor core isolation cooling (RCIC) have been started manually in order to compensate the level drop. The remaining water in the feedwater (FW) lines flashes due to saturation conditions originated from RPV depressurization and refills the reactor downcomer. The plant boundary conditions have been used in the simulations and the FW flow rate has been adjusted for better prediction. The simulations reproduce the plant data with good agreement. It can be concluded that the TRAC-BF1 existing model has been used successfully to develop the TRACE model and the results of the calculations have shown good agreement with plant recorded data. Beside the modeling assessment, the TRACE and TRAC-BF1 capabilities to reproduce plant physical behavior during the transient have shown satisfactory results. The first step of developing KKL model for TRACE has been successfully achieved and this model is further developed in order to simulate more complex plant behavior such as Turbine Trip. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Severe Accident Research Directions after Fukushima

The accidents at the Fukushima Daiichi nuclear power station in March of 2011 renewed interest globally in the nature, causes, and health and economic consequences of severe accidents involving core damage and containment impairment. As a result of these accidents, research has been conducted into the modeling and phenomenological understanding of the accidents at Fukushima and the response and effectiveness of mitigating measures such as emergency water injection, primary system depressurization and containment venting actions. An important example of this is the jointly conducted OECD-NEA organized Benchmark of the Fukushima Accidents (BSAF project) where accident reconstruction analyses using computer codes such as MELCOR and MAAP are ongoing. Even prior to the Fukushima accidents, the Sandia/NRC sponsored State of Art Reactor Consequence Analyses (SOARCA) foreshadowed the accidents in Japan where long-term and short-term station blackout accidents in boiling water reactors with Mark-1 containment were analyzed showing striking similarities to the accidents at Fukushima. These analyses also highlighted important differences in our prior understanding, in particular the importance of suppression pool thermal stratification and the extraordinary operation of the Fukushima Unit-2 reactor core isolation cooling (RCIC) system, prompting addition research into both of these areas. Additionally, the focus of the world's major computer codes on modeling the Fukushima accidents in the BSAF effort, led to several 'Crosswalk' comparisons between code predictions, highlighting subtle but important modeling differences between the codes and identifying areas where modeling improvements can be made. Collectively, these research areas are aimed at improving our understanding of severe accident progression and real-world response of safety related systems and components, and should lead to improved accident response and mitigation capabilities in the future. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SINGLE PHASE ANALYTICAL MODELS FOR TERRY TURBINE NOZZLE

All BWR RCIC (Reactor Core Isolation Cooling) systems and PWR AFW (Auxiliary Feed Water) systems use Terry turbine, which is composed of the wheel with turbine buckets and several groups of fixed nozzles and reversing chambers inside the turbine casing. The inlet steam is accelerated through the turbine nozzle and impacts on the wheel buckets, generating work to drive the RCIC pump. As part of the efforts to understand the unexpected “self-regulating” mode of the RCIC systems in Fukushima accidents and extend BWR RCIC and PWR AFW operational range and flexibility, mechanistic models for the Terry turbine, based on Sandia National Laboratories’ original work, has been developed and implemented in the RELAP-7 code to simulate the RCIC system. RELAP-7 is a new reactor system code currently under development with the funding support from U.S. Department of Energy. The RELAP-7 code is a fully implicit code and the preconditioned Jacobian-free Newton-Krylov (JFNK) method is used to solve the discretized nonlinear system. This paper presents a set of analytical models for simulating the flow through the Terry turbine nozzles when inlet fluid is pure steam. The implementation of the models into RELAP-7 will be briefly discussed. In the Sandia model, the turbine bucket inlet velocity is provided according to a reduced-order model, which was obtained from a large number of CFD simulations. In this work, we propose an alternative method, using an under-expanded jet model to obtain the velocity and thermodynamic conditions for the turbine bucket inlet. The models include both adiabatic expansion process inside the nozzle and free expansion process out of the nozzle to reach the ambient pressure. The combined models are able to predict the steam mass flow rate and supersonic velocity to the Terry turbine bucket entrance, which are the necessary input conditions for the Terry Turbine rotor model. The nozzle analytical models were validated with experimental data and benchmarked with CFD simulations. The analytical models generally agree well with the experimental data and CFD simulations. The analytical models are suitable for implementation into a reactor system analysis code or severe accident code as part of mechanistic and dynamical models to understand the RCIC behaviors. The cases with two-phase flow at the turbine inlet will be pursued in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and Implementation of Mechanistic Terry Turbine Models in RELAP-7 to Simulate RCIC Normal Operation Conditions

As part of the efforts to understand the unexpected “self-regulating” mode of the RCIC (Reactor Core Isolation Cooling) systems in Fukushima accidents and extend BWR RCIC and PWR AFW (Auxiliary Feed Water) operational range and flexibility, mechanistic models for the Terry turbine, based on Sandia’s original work [1], have been developed and implemented in the RELAP-7 code to simulate the RCIC system. In 2016, our effort has been focused on normal working conditions of the RCIC system. More complex off-design conditions will be pursued in later years when more data are available. In the Sandia model, the turbine stator inlet velocity is provided according to a reduced-order model which was obtained from a large number of CFD (computational fluid dynamics) simulations. In this work, we propose an alternative method, using an under-expanded jet model to obtain the velocity and thermodynamic conditions for the turbine stator inlet. The models include both an adiabatic expansion process inside the nozzle and a free expansion process outside of the nozzle to ambient pressure. The combined models are able to predict the steam mass flow rate and supersonic velocity to the Terry turbine bucket entrance, which are the necessary input information for the Terry turbine rotor model. The analytical models for the nozzle were validated with experimental data and benchmarked with CFD simulations. The analytical models generally agree well with the experimental data and CFD simulations. The analytical models are suitable for implementation into a reactor system analysis code or severe accident code as part of mechanistic and dynamical models to understand the RCIC behaviors. The newly developed nozzle models and modified turbine rotor model according to the Sandia’s original work have been implemented into RELAP-7, along with the original Sandia Terry turbine model. A new pump model has also been developed and implemented to couple with the Terry turbine model. An input model was developed to test the Terry turbine RCIC system, which generates reasonable results. Both the INL RCIC model and the Sandia RCIC model produce results matching major rated parameters such as the rotational speed, pump torque, and the turbine shaft work for the normal operation condition. The Sandia model is more sensitive to the turbine outlet pressure than the INL model. The next step will be further refining the Terry turbine models by including two-phase flow cases so that off-design conditions can be simulated. The pump model could also be enhanced with the use of the homologous curves.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

Comparing Simulation Results with Traditional PRA Model on a Boiling Water Reactor Station Blackout Case Study

A previous study used RELAP and RAVEN to conduct a boiling water reactor station black-out (SBO) case study in a simulation based environment to show the capabilities of the risk-informed safety margin characterization methodology. This report compares the RELAP/RAVEN simulation results with traditional PRA model results. The RELAP/RAVEN simulation run results were reviewed for their input parameters and output results. The input parameters for each simulation run include various timing information such as diesel generator or offsite power recovery time, Safety Relief Valve stuck open time, High Pressure Core Injection or Reactor Core Isolation Cooling fail to run time, extended core cooling operation time, depressurization delay time, and firewater injection time. The output results include the maximum fuel clad temperature, the outcome, and the simulation end time. A traditional SBO PRA model in this report contains four event trees that are linked together with the transferring feature in SAPHIRE software. Unlike the usual Level 1 PRA quantification process in which only core damage sequences are quantified, this report quantifies all SBO sequences, whether they are core damage sequences or success (i.e., non core damage) sequences, in order to provide a full comparison with the simulation results. Three different approaches were used to solve event tree top events and quantify the SBO sequences: “W” process flag, default process flag without proper adjustment, and default process flag with adjustment to account for the success branch probabilities. Without post-processing, the first two approaches yield incorrect results with a total conditional probability greater than 1.0. The last approach accounts for the success branch probabilities and provides correct conditional sequence probabilities that are to be used for comparison. To better compare the results from the PRA model and the simulation runs, a simplified SBO event tree was developed with only four top events and eighteen SBO sequences (versus fifty-four SBO sequences in the original SBO model). The estimated SBO sequence conditional probabilities from the original SBO model were integrated to the corresponding sequences in the simplified SBO event tree. These results were then compared with the simulation run results.

99 GENERAL AND MISCELLANEOUS↗

High-resolution time-resolved experiments on mixing and entrainment of buoyant jets in stratified environments

Fluid jets interacting with a stratified layer play an important role in the safety of several reactor designs. In the containment of nuclear power plants, fluid jets dominate the transport and mixing of gaseous species and consequent hydrogen distribution in case of a severe accident. The mixing phenomena in the containment are driven by buoyant high-momentum injections (jets) and low momentum injection plumes. Mixing near the postulated break is initially dominated by high flow velocities. Plumes with moderate flow velocities are instead relevant in the break compartment during the long-term pressurization phase, or in any of the apertures between two connected compartments if the mass flows are sufficiently high and the density differences between efflux and ambient are sufficiently low. Phenomena of interest include free plumes (as produced by the efflux from the break compartment in a larger room or directly from a break flow), wall plumes (such those produced by low mass flows through inter-compartment apertures), and propagating stratification fronts in the ambient (for any stably stratified conditions). These phenomena have been highly ranked about nuclear reactor design, especially regarding of safety protocols. During a Pressurized Thermal Shock (PTS) scenario, the interaction between the cold ECCS injection plume and the stratified fluid present in the cold (or hot) leg is important in order to determine the temperature at the time-dependent temperature at the inlet of the reactor pressure vessel (RPV) and the potential to cause a thermal shock on the RPV wall. In sodium-cooled fast reactors (SFRs), core channels are typically hydro-dynamically isolated so that there exists a considerable temperature variation at the exit of adjacent fuel assemblies. All the above phenomena are characterized by the interaction of buoyant jets with the stratified flow. In stratified layers baroclinic forces create significant redistribution of turbulent kinetic energy and scales, which leads to anisotropy. This important physical phenomenon is highly three dimensional and is challenging to capture even with high-fidelity CFD simulations, due in part to lack of sufficiently resolved validation data. Furthermore, the experimental data available in the open literature do not feature the level of fidelity needed for an extensive validation of turbulence models in lower order CFD. To shed new lights into the crucial phenomena object of the present research project, it was proposed to conduct coordinated experiments and simulations at the University of Michigan and the George Washington University. The project has resulted in an experimental database of high-resolution time-resolved measurements of jets in uniform and stratified environments. The novel experimental data will be used to validate computational fluid dynamic (CFD) codes, including both Large Eddy Simulations (LES) and unsteady Reynolds-averaged Navier-Stokes equations (URANS) methodologies. In the Experimental and Multiphase flow (ECMF) laboratory at Univerisity of Michigan, we built two experimental facilities to investigate also the effect of scaling. The first facility, DESTROJER (DEnsity Stratified Turbulent ROund free Jet ExpeRiment), featuring a contoured jet nozzle with a diameter of D=12.7mm and a 1m×1m×1m cubic tank, which is made of acrylic glass for optical access. The ratio between the tank width and the nozzle diameter is equal to 78, which ensures that there is no direct interaction between the jet and the side walls. A second, modular experimental facility, features three different tank sizes of size 10×10×30, 20×20×30, 30×30×30 cm3 respectively (all tanks have the same height of 30 cm), and a jet diameter of 2mm. For the modular facility, tank-to-nozzle ratio of 50, 100, and 150 are obtained respectively. Experiments with different-density jet impactions and sharp interface with a density difference of 3.16% In the Laboratory at George Washington University, complementary experiments have been carried out at a facility featuring the same dimensions as DESTROYER. Experiments with different jet diameters have been carried out as well. High-resolution time-resolved measurements have been performed at all facilities using high-speed particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF). In this way, simultaneous measurements of velocity and density fields have been carried out. At the University of Michigan, wire-mesh sensors have been designed and built to gather high-resolution, time-dependent data of the stratified front in the tank. These measurements are important to provide accurate initial conditions for the CFD simulations. An important outcome of the project has been the development of novel techniques to achieve refractive index matching (RIM) of acqueous solutions with high density differences. RIM is crucial if optical techniques such as PIV are used to measure velocity fields. Previous to this project, experiments up to 3% density difference had been reported in the literature. With the methodology developed in this project, we have been able to push the envelop to density differences up to 9%. The experiments have been used to validate Reynolds Averaged Navier-Stokes (RANS) turbulence models and Large Eddy Simulations (LES) models. Both NEK5000 and the commercial CFD code STAR-CCM+ have been used. The experimental data will be made available to the community through the NE-KAMS databasehave been successfully conducted in the scaled facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Inadvertent actuation block valve for a small modular nuclear reactor

An inadvertent actuation block valve includes inlet and outlet orifices being in selective fluid communication via a chamber. A disc is disposed within the chamber and a bellows is configured to contract at a predetermined pressure differential between reactor fluid entering a reference pressure orifice and control fluid entering the inlet orifice. When the bellows contracts, the disc engages the outlet orifice and isolates fluid communication between the inlet and outlet orifices. The inadvertent actuation block valve prevents inadvertent opening of an emergency core cooling valve when a reactor is at operating pressure that is above the predetermined set pressure range. The inadvertent actuation block valve permits the emergency cooling valves to open and to remain open when reactor pressure is below the predetermined set pressure range. The inadvertent actuation block valve does not impede long term emergency cooling that occurs when the reactor is at low pressure.

O'Brien, Hugh S.↗

Treatment of Reactor Systems within Draft Regulatory Guide 1.183 DG-1199

In this note, a review of concerns relevant to Draft Regulatory Guide 1.183 rev.1 (DG-1199) is presented. These comments pertain to the treatment of the main steam line isolation valve (MSIV), emergency core cooling system (ECCS) and engineered safety features (ESF) during postulated accident scenarios contained within the regulatory guide. These comments are particularly salient to the mitigation and decontamination of the full core source created during a loss of coolant accident (LOCA) for boiling water reactors (BWRs).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Water Ingress Effects on the Reactivity Change of the Conceptual Designed Reactor at NIST

The conceptual research reactor design with a split core for a replacement reactor project at the NIST (National Institute of Standards and Technology) Center for Neutron Research is underway. The reactor core is cooled and moderated by light water and reflected by heavy water in a reflector tank. The reactor core is immersed in light water, which is isolated from heavy water with a slightly pressurized boundary box made of zirconium alloy. The heavy water is contained in a large size cylindrical tank which also provides ample space to accommodate neutron beam tubes, cold sources and other irradiation equipment. The reflector tank is placed in the center of a large light water pool, which provides thermal and biological shielding to the reactor. Light water and heavy water have distinct physical properties in regard to neutron moderation. Light water is generally known to have greater moderating power and absorption cross-sections, while heavy water has a higher moderating ratio. Due to these differences in properties, the accidental mixing of light water and heavy water in either direction will inevitably affect the reactivity of the reactor. Moreover, since the neutron flux spectrum at different locations of the reactor will have significantly different characteristics (for example, the spectrum at the heavy tank should be much softer than that at the core center region), the effect of reactivity changes becomes complicated and will depend on the water mixing locations. From the reactor safety analysis perspective, the water ingress reactivity change is one of the required design base reactivity accidents that must be evaluated in the final safety analysis report. Given these concerns, neutronics calculations have been performed to determine the effect and trend of the reactivity changes due to water ingress in different scenarios by purposely mixing the waters at three representative places in the reactor: the reflector area, the center coolant area and the peripheral coolant area. These three places were selected for the study because of their uniqueness in the flux spectrum (as shown in the results section). Simple static neutronics calculations were performed using MCNP6 to examine the reactivity effects due to water ingress. It should be noted that all calculations performed in this study assume homogeneous water mixing in the area of interest; therefore, the local effect of the mixing situation would possibly be missed by this study. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimize out-of-core thermionic energy conversion for nuclear electric propulsion

Thermionic energy conversion (TEC) potentialities for nuclear electric propulsion (NEP) are examined. Considering current designs, their limitations, and risks raises critical questions about the use of TEC for NEP. Apparently a reactor cooled by hotter-than-1675 K heat pipes has good potentialities. TEC with higher temperatures and greater power densities than the currently proposed 1650 K, 5-to-6 W/sq cm version offers substantial gains. Other approaches to high-temperature electric isolation appear also promising. A high-power-density, high-temperature TEC for NEP appears, therefore, attainable. It is recommended to optimize out-of-core thermionic energy conversion for nuclear electric propulsion. Although current TEC designs for NEP seem unnecessary compared with Brayton versions, large gains are apparently possible with increased temperatures and greater power densities.

Morris, J. F.↗