Search NASA⌕ Search

SEARCH · Search NASA

Results for “Received Signal Strength Indicator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Investigations of Remote Plasma Irregularites by Radio Sounding: Applications of the Radio Plasma Imager on IMAGE

The Radio Plasma Imager (RPI) on the Imager for Magnetopause-to-Aurora Global Exploration (IMAGE) mission operates like a radar by transmitting and receiving coherent electromagnetic pulses. Long-range echoes of electromagnetic sounder waves are reflected at remote plasma cutoffs. Thus, analyses of RPI observations will yield the plasma parameters and distances to the remote reflection points. These analyses assume that the reflecting plasma surfaces are cold and are sufficiently smooth that they effectively behave as plane mirrors to the incoming sounder waves, i.e., that geometric optics can be used. The RPI will employ pulse compression and spectral integration techniques, perfected in ground-based ionospheric digital sounders, in order to enhance the signal-to-noise ratio in long-range magnetospheric sounding. When plasma irregularities exist in the remote magnetospheric plasmas that are being probed by the sounder waves, echo signatures may become complicated. Ionospheric sounding experience indicates that while topside sounding echo strengths can actually be enhanced by the presence of irregularities, ground-based sounding indicates that coherent detection techniques can still be employed. In this paper we investigate the plasma conditions that will allow coherent signals to be detected by the RPI and the signatures to be expected, such as scattering and plasma resonances, in the presence of multi-scale irregularities, may possibly have on RPI signals. Sounding of irregular plasma structures in the plasmasphere, plasmapause and magnetopause are also discussed.

Fung, Shing F.↗

Introductory guide to backgrounds in XPS spectra and their impact on determining peak intensities

Photoelectron and Auger peaks are central to most of the important uses of x-ray photoelectron spectroscopy (XPS), and thus, they receive the most attention in many types of analysis. Quantitative chemical analysis using XPS requires the assessment of the intensities of the photoemission peaks of the elements detected. Determination of peak intensities requires separation of the photoelectron peak signals from the background on which the peaks rest. For the determination of peak area intensities, the background is subtracted from overall signal intensity. The spectral background is also critical when peak fitting is used to determine intensities of overlapping peaks, and the model of background used in this process can impact the results. In addition to the impact on quantitative analysis, information about the depth distribution of elements in the near surface region can often be obtained by visual inspection of the background and quantified using appropriate modeling. Here, this introductory guide provides some basic information about backgrounds in the XPS analysis, describes the types of background models that are commonly used, suggests some of their strengths and weaknesses, and provides examples of their use and misuse. Although the fundamental nature of some components of the background signals in XPS is not understood, indicating that none of the models in use are fully correct and the area is subject to active research, appropriate good practices have been established for most routine analysis. The guide describes good practices, identifies errors that frequently appear in the literature, and uses examples to demonstrate the impacts of background selections on determinations of peak intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous observations of VLF ground transmitter signals on the DE 1 and COSMOC 1809 satellites: Detection of a magnetospheric caustic and a duct

Khabarovsk transmitter signals (15.0 kHz, 48 deg N, 135 deg E) were observed on the high-altitude (approximately 15000 km) Dynamic Explorer 1 (DE 1) and the low-altitude (approximately 960) km COSMOS 1809 satellites during a 9-day period in August 1989. On 7 out of 9 days the linear wave receiver (LWR) on the DE 1 satellite also detected signals from the Alpha transmitter (11.9-15.6 kHz) in Russia and an Omega transmitter (10.2-13.6 kHz) in Australia, as well as natural VLF emissions such as hiss, chorus, whistlers, and wideband impulsive signals. On two days, August 23 and 27, 1989, observations of the Khabarovsk transmitter signals were simultaneously carried out at high altitude on thre DE 1 satellite and at low altitude on the COSMOS 1809 satellite. Analysis of data from these 2 days has led to several new results on the propagation of whistler mode signals in the Earth's magnetosphere. New evidence was found of previously reported propagation phenomena, such as (1) confinement of transmitter signals in the conjugate hemisphere at ionospheric heights (approximately 1000 km), (2) observation of direct multipath propagation on both DE 1 and COSMOS 1809, (3) detection of ionospheric irregularities of is less than or equal to 100 km scale size with a few percent enhancement in electron density. We also report the first direct detection of a magnetospheric dust at L = 2.94 which was believed to be responsible for the ducted propagation of Khabarovsk signals observed in the COSMOS 1809 satellite. Our study also indicates that duct end points can extend down to at least approximately 1000 km. The peak electric and magnetic fields of ducted Khabarovsk transmitter signals at approximately 1000 km were 520 micro V/m and 36 pT respectively. Estimated field strengths of these signals inside the dust at the geomagnetic equator were 57 micro V/m and 12 pT for electric and magnetic field respectively. The results of two-dimensional ray tracing simulations were consistent with the observations of the nonducted whistler-mode propagation of Khabarovsk (15 kHz) and Alpha (11.9 kHz) signals from the transmitter location to the DE 1 and COSMOS 1809 satellites. Our results have direct implications for the question of accessibility of waves injected from the ground to various regions of the ionosphere and the magnetosphere.

Chmyrev, V. M.↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗