Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The operational performance of hydrogen masers in the Deep Space Network (the performance of laboratory reference frequency standards in an operational environment)

Spacecraft navigation to the outer planets (Jupiter and beyond) places very stringent demands upon the performance of frequency and time (F&T) reference standards. The Deep Space Network (DSN) makes use of hydrogen masers as an aid in meeting the routine F&T operational requirements within the 64 m antenna network. Results as of October 1980 indicate the hydrogen masers are performing within the required specifications. Two problem areas are discussed: insufficient control over the environment in which the reference standards reside; and frequency drift.

Ward, S. C.↗

Metal Standards for Waveguide Characterization of Materials

Rectangular-waveguide inserts that are made of non-ferromagnetic metals and are sized and shaped to function as notch filters have been conceived as reference standards for use in the rectangular- waveguide method of characterizing materials with respect to such constitutive electromagnetic properties as permittivity and permeability. Such standards are needed for determining the accuracy of measurements used in the method, as described below. In this method, a specimen of a material to be characterized is cut to a prescribed size and shape and inserted in a rectangular- waveguide test fixture, wherein the specimen is irradiated with a known source signal and detectors are used to measure the signals reflected by, and transmitted through, the specimen. Scattering parameters [also known as "S" parameters (S11, S12, S21, and S22)] are computed from ratios between the transmitted and reflected signals and the source signal. Then the permeability and permittivity of the specimen material are derived from the scattering parameters. Theoretically, the technique for calculating the permeability and permittivity from the scattering parameters is exact, but the accuracy of the results depends on the accuracy of the measurements from which the scattering parameters are obtained. To determine whether the measurements are accurate, it is necessary to perform comparable measurements on reference standards, which are essentially specimens that have known scattering parameters. To be most useful, reference standards should provide the full range of scattering-parameter values that can be obtained from material specimens. Specifically, measurements of the backscattering parameter (S11) from no reflection to total reflection and of the forward-transmission parameter (S21) from no transmission to total transmission are needed. A reference standard that functions as a notch (band-stop) filter can satisfy this need because as the signal frequency is varied across the frequency range for which the filter is designed, the scattering parameters vary over the ranges of values between the extremes of total reflection and total transmission. A notch-filter reference standard in the form of a rectangular-waveguide insert that has a size and shape similar to that of a material specimen is advantageous because the measurement configuration used for the reference standard can be the same as that for a material specimen. Typically a specimen is a block of material that fills a waveguide cross-section but occupies only a small fraction of the length of the waveguide. A reference standard of the present type (see figure) is a metal block that fills part of a waveguide cross section and contains a slot, the long dimension of which can be chosen to tailor the notch frequency to a desired value. The scattering parameters and notch frequency can be estimated with high accuracy by use of commercially available electromagnetic-field-simulating software. The block can be fabricated to the requisite precision by wire electrical-discharge machining. In use, the accuracy of measurements is determined by comparison of (1) the scattering parameters calculated from the measurements with (2) the scattering parameters calculated by the aforementioned software.

Lambert, Kevin M.↗

Digital data registration and differencing compression system

A process is disclosed for x ray registration and differencing which results in more efficient compression. Differencing of registered modeled subject image with a modeled reference image forms a differenced image for compression with conventional compression algorithms. Obtention of a modeled reference image includes modeling a relatively unrelated standard reference image upon a three-dimensional model, which three-dimensional model is also used to model the subject image for obtaining the modeled subject image. The registration process of the modeled subject image and modeled reference image translationally correlates such modeled images for resulting correlation thereof in spatial and spectral dimensions. Prior to compression, a portion of the image falling outside a designated area of interest may be eliminated, for subsequent replenishment with a standard reference image. The compressed differenced image may be subsequently transmitted and/or stored, for subsequent decompression and addition to a standard reference image so as to form a reconstituted or approximated subject image at either a remote location and/or at a later moment in time. Overall effective compression ratios of 100:1 are possible for thoracic x ray digital images.

Ransford, Gary A.↗

Digital data registration and differencing compression system

A process for x ray registration and differencing results in more efficient compression is discussed. Differencing of registered modeled subject image with a modeled reference image forms a differential image for compression with conventional compression algorithms. Obtention of a modeled reference image includes modeling a relatively unrelated standard reference image upon a three dimensional model, which three dimensional model is also used to model the subject image for obtaining the modeled subject image. The registration process of the modeled subject image and modeled reference image translationally correlates such modeled images for resulting correlation thereof in spatial and spectral dimensions. Prior to compression, a portion of the image falling outside a designated area of interest may be eliminated, for subsequent replenishment with a standard reference image. The compressed differenced image may be subsequently transmitted and/or stored, for subsequent decompression and addition to a standard reference image so as to form a reconstituted or approximated subject image at either remote location and/or at a later moment in time. Overall effective compression ratios of 100:1 are possible for thoracic x ray digital images.

Ransford, Gary A.↗

Digital Data Registration and Differencing Compression System

A process for X-ray registration and differencing results in more efficient compression. Differencing of registered modeled subject image with a modeled reference image forms a differenced image for compression with conventional compression algorithms. Obtention of a modeled reference image includes modeling a relatively unrelated standard reference image upon a three-dimensional model, which three-dimensional model is also used to model the subject image for obtaining the modeled subject image. The registration process of the modeled subject image and modeled reference image translationally correlates such modeled images for resulting correlation thereof in spatial and spectral dimensions. Prior to compression, a portion of the image falling outside a designated area of interest may be eliminated, for subsequent replenishment with a standard reference image. The compressed differenced image may be subsequently transmitted and/or stored, for subsequent decompression and addition to a standard reference image so as to form a reconstituted or approximated subject image at either a remote location and/or at a later moment in time. Overall effective compression ratios of 100:1 are possible for thoracic X-ray digital images.

Ransford, Gary A.↗

Ultrasonic angle beam standard reflector

A method that provides an impression profile in a reference standard material utilized in inspecting critically stressed components with pulsed ultrasound is described. A die stamp having an I letter is used to impress the surface of a reference material. The die stamp is placed against the surface and struck with an inertia imparting member to impress the I in the reference standard material. Upset may appear on the surface as a result of the impression and is removed to form a smooth surface. The stamping and upset removal is repeated until the entire surface area of a depth control platform on the die stamp uniformly contacts the material surface. The I impression profile in the reference standard material is utilized for reflecting pulsed ultrasonic beams for inspection purposes.

Berry, R. F., Jr.↗

A Generalized Logical Format for Inter-Calibrated Brightness Temperatures for the Global Precipitation Measurement Mission

An important aspect of the GPM mission is the merging of precipitation data from multiple radiometers on different satellites. This requires that each radiometer be consistently calibrated and that each be intercalibrated with a mission reference standard. For GPM the reference standard is to be the core satellite carrying a dual frequency precipitation radar and a well calibrated conically scanning radiometer. This paper describes a common format for representing these intercalibrated brightness temperatures which will be used for all radiometer products from GPM partner satellites. The use of common formats ensures that users obtain all the required information and also facilitates the rain retrieval algorithm code preparation as it can always except to have the data that it needs for the retrieval.

Stocker, Erich Franz↗

Results of the 1995 JPL balloon flight solar cell calibration program

The Jet Propulsion Laboratory (JPL) solar cell calibration program was conceived to produce reference standards for the purpose of accurately setting solar simulator intensities. The concept was to fly solar cells on a high-altitude balloon, to measure their output at altitudes near 120,000 ft (36.6 km), to recover the cells, and to use them as reference standards. The procedure is simple. The reference cell is placed in the simulator beam, and the beam intensity is adjusted until the reference cell reads the same as it read on the balloon. As long as the reference cell has the same spectral response as the cells or panels to be measured, this is a very accurate method of setting the intensity. But as solar cell technology changes, the spectral response of the solar cells changes also, and reference standards using the new technology must be built and calibrated. Until the summer of 1985, there had always been a question as to how much the atmosphere above the balloon modified the solar spectrum. If the modification was significant, the reference cells might not have the required accuracy. Solar cells made in recent years have increasingly higher blue responses, and if the atmosphere has any effect at all, it would be expected to modify the calibration of these newer blue cells much more so than for cells made in the past. JPL has been flying calibration standards on high-altitude balloons since 1963 and continues to organize a calibration balloon flight at least once a year. The 1995 flight was the 48th flight in this series. The 1995 flight incorporated 46 solar cell modules from 7 different participants. The payload included Si, amorphous Si, GaAs, GaAs/Ge, dual junction cells, top and bottom sections of dual junction cells, and a triple junction cell. A new data acquisition system was built for the balloon flights and flown for the first time on the 1995 flight. This system allows the measurement of current-voltage (I-V) curves for 20 modules in addition to measurement of modules with fixed loads as had been done in the past.

Anspaugh, B. E.↗

Quantitative Technique for Comparing Simulant Materials through Figures of Merit

The 1989 workshop report entitled Workshop on Production and Uses of Simulated Lunar Materials and the Lunar Regolith Simulant Materials: Recommendations for Standardization, Production, and Usage, NASA Technical Publication both identified and reinforced a need for a set of standards and requirements for the production and usage of the Lunar simulant materials. As NASA prepares to return to the Moon, and set out to Mars, a set of early requirements have been developed for simulant materials and the initial methods to produce and measure those simulants have been defined. Addressed in the requirements document are: 1) a method for evaluating the quality of any simulant of a regolith, 2) the minimum characteristics for simulants of Lunar regolith, and 3) a method to produce simulants needed for NASA's Exploration mission. As an extension of the requirements document a method to evaluate new and current simulants has been rigorously defined through the mathematics of Figures of Merit (FoM). Requirements and techniques have been developed that allow the simulant provider to compare their product to a standard reference material through Figures of Merit. Standard reference material may be physical material such as the Apollo core samples or material properties predicted for any landing site. The simulant provider is not restricted to providing a single "high fidelity" simulant, which may be costly to produce. The provider can now develop "lower fidelity" simulants for engineering applications such as drilling and mobility applications.

Rickman, Doug↗

Laboratory techniques and rhythmometry

Some of the procedures used for the analysis of rhythms are illustrated, notably as these apply to current medical and biological practice. For a quantitative approach to medical and broader socio-ecologic goals, the chronobiologist gathers numerical objective reference standards for rhythmic biophysical, biochemical, and behavioral variables. These biological reference standards can be derived by specialized computer analyses of largely self-measured (until eventually automatically recorded) time series (autorhythmometry). Objective numerical values for individual and population parameters of reproductive cycles can be obtained concomitantly with characteristics of about-yearly (circannual), about-daily (circadian) and other rhythms.

Halberg, F.↗

Spacecraft signal sources portable test system

There is a frequent need to measure the frequency stability and phase noise levels of very high performance signal sources that are required for certain spacecraft missions. These measurements need to be done at different locations as the spacecraft subsystems progress through the various stages of development, assembly, test, and integration. Allan Deviation and Phase Noise of high performance sources are generally measured by comparing the unit under test to a reference standard. Five basic requirements are associated with making these kind of measurements: (1) the reference standard performance needs to be equal or better than the unit under test; (2) the measurement system needs to accommodate odd, nonstandard measurement frequencies that can range from 4 MHz to 35 GHz; (3) warm-up frequency drift and aging can corrupt a measurement and must be dealt with; (4) test equipment generated noise must be understood and prevented from limiting the measurements; (5) test equipment noise performance must be verifiable in the field as needed. A portable measurement system that was built by JPL and used in the field is described. The methods of addressing the above requirements are outlined and some measurement noise floor values are given. This test set was recently used to measure state of the art crystal oscillator frequency standards on the TOPEX and MARS OBSERVER spacecraft during several stages of acceptance tests.

Kirk, Albert↗

Rest-wavelength Fiducials for the ITER Core Imaging X-ray Spectrometer

Absolute wavelength references are needed to derive the plasma velocities from the Doppler shift of a given line emitted by a moving plasma. We show that such reference standards exist for the strongest x-ray line in neonlike W64+, which has become the line of choice for the ITER (Latin the way) core imaging x-ray spectrometer. Close-by standards are the Hf L3 line and the Ir L2 line, which bracket the W64+ line by 30 eV; other standards are given by the Ir L1 and L2 lines and the Hf L1 and L2 lines, which bracket the W64+ line by 40 and 160 eV, respectively. The reference standards can be produced by an x-ray tube built into the ITER spectrometer. We present spectra of the reference lines obtained with an x-ray microcalorimeter and compare them to spectra of the W64+ line obtained both with an x-ray microcalorimeter and a crystal spectrometer

Rest-wavelength↗

Development and Validation of NDE Standards for NASA’s Advanced Composites Project

The adoption of composite materials in aircraft manufacturing for use in structural applications continues to increase but is still relatively new to the industry. Composite components have large development and certification costs in comparison to metallic structures. Traditional methods of nondestructive evaluation (NDE) used for isotropic materials such as metals may not be adequate for composite applications and therefore is a contributing factor to the cost and complexity of developing new structural composites. Additionally, the defects of interest in composite materials are significantly different from metals. Thus, good quality composite reference standards are essential to obtaining reliable and quantifiable NDE results. Ideally, reference standards contain flaws or damage whose NDE indications most closely represent those created by actual flaws/damage. They should also be easy to duplicate and inexpensive to manufacture. NASA’s Advanced Composites Project, working with industry partners, developed a set of composite standards that contain a range of validated defects representing those typically found in aerospace composite materials. This paper will provide an overview of the standards fabricated, the manufacturing plans used to fabricate them, the types of defects included, and validation testing that has performed. Also discussed is an inter-laboratory “round-robin” test that is being performed on these standards. The paper will describe a guidance document being compiled to outline relevant inspection procedures for challenging and critical defects unique to composites where conventional techniques may not be appropriate.

Cramer, K. Elliott↗

Revised Depletions and New Constraints on Interstellar Dust Composition

We have reviewed the literature on composition of young stars, both hot and cool, as well as older solar-type stars. We find that all these classes of stars have lower abundances of the heavy elements (specifically C, N, O, Mg, Si, and Fe) than the sun. Therefore studies of interstellar depletions in which the solar composition is used as the reference standard are probably in error, tending to overestimate the total quantities of these elements, hence the depletions. We have revised the depletion estimates, using stellar abundances as the reference standard and making use of recent IS gas-phase abundance measurements. As a result of our revised depletions, we can place new and stringent constraints on several published models for the interstellar dust.

Snow, Theodore P.↗

Isotopic composition of lithium, potassium, rubidium, and strontium in lunar surface material

The isotopic composition of alkali and alkaline earth elements in the Luna 16 regolith was investigated by the method of thermionic emission, without chemical separation. The isotopic composition of the lithium in two regolith samples did not differ (within the limits 0.5 percent) from the mean of the terrestrial reference standard. At the same time, the observed difference (1 percent) in the isotopic composition of lithium between the samples requires further investigation and confirmation. The isotopic compositions of K and Rb did not differ within the limits of experimental error from the isotopic composition of the reference standard.

Zaslavskiy, V. G.↗

Measuring Thermal Conductivities Of Rough Specimens

Thermal conductivity of irregularly surfaced specimen measured more accurately and reliably by use of heat-transfer adhesive establishing contact between specimen and reference standards. Method useful when specimen made up of fragments of material. Adhesive ensures good thermal contact to pieces not matching others in height. In rough-surfaced or unequally sized specimens, heat-flow pattern becomes distorted, and temperatures at measurement points do not accurately represent those throughout reference standards and specimen. Filling voids with conductive adhesive restores nearly uniform distribution heat flow.

Striepens, Aloys H.↗

The operational performance of hydrogen masers in the deep space network: The performance of laboratory reference frequency standards in an operational environment

Hydrogen masers used as aids in meeting the routine frequency and time operational requirements within the 64 m antenna Deep Space Network. Both the operational syntonation (frequency synchronization) and the the clock (epoch) synchronization requirements were established through the use of specifically calibrated H-P E215061A flying clock. The sync/synt to UTC was maintained using LORAN and TV in simultaneous reception mode. The sync/synt within the 64 m net was maintained through the use of very long base interferometry. Results indicate that the hydrogen masers perform well within the required specifications.

Ward, S. C.↗

Standard wool fabric as a reference material

Standard wool fabric is investigated as a potential reference material. A screening test method for relative toxicity exposes four albino male rats enclosed in a 4.2 liter hemispherical chamber to pyrolysis effluents produced by pyrolyzing a 1.00 g sample under a variety of test conditions (200-800 C with a 40 C/min heating rate). It is found that for fabrics containing 86-100% wool, animal response remains virtually unchanged, although a 100% wool fabric is preferred as it eliminates local composition differences as a source of variation.

Hilado, C. J.↗