Search NASA⌕ Search

SEARCH · Search NASA

Results for “Refrigeration Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗

Effective properties of semitransparent radiative cooling materials with spectrally variable properties

Radiative cooling is a promising solid-state, non-vapor-compression technology for passive refrigeration and air conditioning. Although this phenomenon occurs naturally, achieving a significant amount of cooling to make it a technically and economically viable technology requires highly engineered, spectrally selective radiative surfaces. These characteristics make radiative cooling difficult to estimate, particularly when it is integrated with other systems such as photovoltaic panels or building envelopes. The complexity further increases when the substrate also participates in the radiative cooling (along with the radiative coating). Energy estimation is becoming increasingly critical because of the recent focus on the semitransparent radiative coatings that transmit a variety of colors to enhance the aesthetic appeal of the system. In this work, we propose an iterative method to calculate the effective radiative properties, which provides the same net radiative cooling that would be observed using the spectral properties at both the coating and substrate surfaces. Compared to traditional methods that rely on either computationally expensive full spectral analysis or methods for averaging each radiative surface parameter locally, our proposed method focuses on calculating effective properties that provide the same the net cooling effect as a full spectral analysis by accounting the emissivity, absorptivity, and transmissivity collectively, thereby providing an overall estimation error of less than 0.2%. We believe that this study will be beneficial to the engineering communities that employ complex simulation codes and require lumped solar and thermal radiation related parameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Eliminating the Need for Refrigerants Using New Liquid and Salt-Based Cooling and Heat-Pumping Technology (CRADA Final Report)

Calion Technologies, Inc. project team investigated various embodiments of the ionocaloric cycle. Ionocaloric technology provides a new platform for all heating and cooling that is zero-GWP, non-toxic, non-hazardous, and non-flammable. It is well-poised to replace vapor compression technology which uses high-GWP refrigerants which are on track to account for 25% of our global warming budget. Developing the ionocaloric technology as a drop-in replacement for vapor compression was the primary research thrust under this CRADA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward a life cycle approach for classifying the toxicity of refrigerants

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world (IEA, 2018). Over the next three decades, as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. While technological advances have led to increased cooling capacity and safer refrigerants over the years, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. Further, because of ongoing and pending policy and regulatory changes to avert ozone depletion and global climate change, there is an increasing focus on adopting compounds that are efficient at cooling while also reducing emissions and other adverse environmental impacts.

54 ENVIRONMENTAL SCIENCES↗

Development of Low-cost Magnetocaloric Materials (CRADA 446)

This is the final report for a TCF funded project, supported by the Hydrogen and Fuel Cell Technology Office. PNNL worked with GE&R, a domestic US company that manufactures magnetocaloric materials (MCM), for potential applications in magnetic refrigeration. The overall goal of this project was to develop an energy-efficient technique to shorten the annealing time of MCM, from days to hours, with the expected benefits of lower costs and shorter lead times. Success in this project will enable industry partner General Engineering & Research LLC (GE&R) to commercialize their high-performance MCM, in support of DOE-Fuel Cell Technology Office’s efforts to develop energy-efficient magnetic refrigeration technology (using MCM) for hydrogen liquefaction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Leak Detection Technologies for Low Global Warming Potential (GWP), Flammable Refrigerants

Current commercial refrigeration systems use refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The emergence of low GWP alternatives (GWP <150) is expected to significantly reduce direct emissions in this sector, playing a crucial role in the ongoing electrification and decarbonization initiatives. However, many of these low GWP alternatives pose a flammability risk, necessitating robust sensing solutions to ensure the reliable and safe operation of the equipment. This paper examines various sensing mechanisms suitable for potential applications in systems that employ flammable refrigerants, specifically those designated as A2L class. It provides a summary of A2L refrigerants and their properties, followed by a comprehensive review of sensor classes, covering their working principles, features, advantages, and limitations. Additionally, the article delves into key performance characteristics such as accuracy, selectivity, sensitivity, dynamic characteristics, and durability, among other properties. The article discusses areas for improvement and suggests corresponding approaches for potential sensors in facilitating the successful adoption of flammable refrigerants. Finally, this paper presents the latest findings from experimental evaluation of 5 different sensing principles in detecting the composition variation as a result of various operational conditions. Reliability and sensitivity of the sensor in responding to shifts in true composition and the resultant LFL value is also discussed.

Reshniak, Viktor↗

A Review of Sensing Technologies for New, Low Global Warming Potential (GWP), Flammable Refrigerants

Commercial refrigeration systems currently utilize refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The advent of low GWP alternatives (GWP <150) is expected to significantly curtail direct emissions from this segment and greatly influence the ongoing electrification and decarbonization efforts. Most of the low GWP alternatives exhibit flammability risk and hence require robust sensing solutions for a reliable and safe operation of the equipment. This review article aims to provide an overview of different sensing mechanisms suitable for potential applications in systems employing flammable refrigerants, particularly those designated as A2L class. A summary of different A2L refrigerants and their properties is provided followed by a broad review of different classes of sensors, their working principle, transduction method, features, advantages, and limitations. Additionally, key performance characteristics of accuracy, selectivity, sensitivity, dynamic characteristic, and durability among other properties are discussed. Finally, areas of improvement and corresponding approaches are suggested for potential sensors in the successful adoption of A2L class refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual refrigerant charge sensor for variable-speed heat pumps based on feature selection

The refrigerant charge level in heat pump systems significantly impacts their energy efficiency. Virtual refrigerant charge (VRC) sensing technology has been comprehensively investigated and well-established due to its lower cost compared to physical sensors. However, the previous VRC research often relied on expert judgment and physical reasoning for their variable selection, which can potentially select redundant (or highly correlated) or insignificant features, and it is also primarily focused on single-speed systems. To address these challenges, this study proposes a VRC algorithm for variable-speed heat pumps that selects features through a rigorous feature selection method in combination with physical insights. We also propose a piecewise linear model structure segmented by subcooling temperature to accurately predict charge levels, particularly when subcooling temperatures are substantially low. The proposed algorithm was evaluated using experimental data of a residential R410A heat pump, and the performance was compared with two baseline VRC algorithms. The results are: (1) The proposed algorithm outperforms for the case with subcooling temperature less than 1 °C. (2) The proposed algorithm achieves a tested mean absolute percentage error (MAPE) of 4.23%, and improves the overall accuracy for cooling conditions by approximately 60%, compared with the two baseline algorithms. (3) The proposed algorithm uses two fewer features and improves the accuracy for undercharge cooling conditions by 68.0%, compared with baseline algorithm 2. These improvements enhance prediction accuracy and prevent overfitting, providing a more reliable refrigerant charge level prediction and helping improve the heat pump energy efficiency.

Liang, Chenjiyu↗

Building Technologies Office 03.02.02.38 Milestone Report — Technology Options for Low Environmental Impact Air-Conditioning and Refrigeration Systems

Due to increasing concerns about global warming, various environmental regulations will eventually phase out refrigerants used in air conditioning and refrigeration systems (e.g., R-410A, R-404A). Several refrigerants have been proposed as replacements, offering a variety of global warming potential (GWP), levels of energy efficiency and flammability. Some of these options are synthetic HFC/HFO mixtures such as R-454C and R-455A while other are commonly called naturals such as R-290 (Propane) and R-744 (Carbon Dioxide). This study discusses the merits of the leading options for air Conditioning and refrigeration systems. The fundamental requirements (environmental, performance, safety) are employed to fairly evaluate these options. Performance data and Life Cycle analysis results for these options are presented. Overall, this study provides information needed to judge the prospects of getting adequate replacement for R-410A and R-404A in a long-term sustainable basis.

42 ENGINEERING↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Clean energy technology pathways from research to commercialization: Policy and practice case studies

Clean energy research and development (R and D) leading to commercial technologies is vital to economic development, technology competitiveness, and reduced environmental impact. Over the past 30 years, such efforts have advanced technology performance and reduced cost by leveraging network effects and economies of scale. After demonstrating promise in applied R and D, successful clean energy and energy efficiency technologies are incorporated into an initial product sold by the private sector. Despite its importance, processes by which first commercialization occurs are difficult to generalize while capturing specific insights from practitioners in markets and technologies. This paper presents a policy-focused qualitative assessment of the first commercialization of four diverse energy technologies: thin film photovoltaics, wind turbine blades, dual-stage refrigeration evaporators, and fuel cells for material handling equipment. Each technology presents distinct value propositions, markets, and regulatory drivers. The case studies indicate three common characteristics of successful first commercialization for new energy technologies: 1) good fit between the technology, R&D infrastructure, and public-private partnership models; 2) high degree of alignment of government regulations and R&D priorities with market forces; and 3) compatibility between time scales required for R&D, product development, and opportunities. These findings may inform energy investment decision-making, maximize benefits from R&D, and advance the transition to a low-emission future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Driving the Shift to Energy-Efficient and Climate-Responsible Commercial Refrigeration Equipment in Chile

This report provides an overview of global and Chile-specific market trends, technological advancements, and policy developments related to commercial refrigeration equipment, with an emphasis on refrigerated display cabinets. Section 2 examines CRE market trends at the global and Chilean levels. Section 3 presents CRE energy consumption and the latest technological options for improving energy performance. It also discusses low global warming potential (GWP)1 refrigerant options for CRE. Section 4 provides a cost-effectiveness analysis. Section 5 reviews other regional energy efficiency standards and labeling programs and offers potential standard requirements for Chile. Section 6 concludes the report by summarizing key findings and conclusions. Finally, Appendix A provides detailed guidelines intended as a starting point to inform policies and programmes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correlation between cation order/disorder and the electrocaloric effect in the MLCCs of complex perovskite ferroelectrics

The physical properties (dielectric, ferroelectric, piezoelectric, etc.) of complex perovskite ferroelectrics depend on the degree of order/disorder and the scale of the ordered domains. In this study, the electrocaloric (EC) properties of three representative complex perovskite ferroelectrics, Pb(Mg 1/3 Nb 2/3 )O 3 -8PbTiO 3 (PMN-8PT), 1mol% Sm-doped Pb(Mg 1/3 Nb 2/3 )O 3 -8PbTiO 3 (1S-PMN-8PT) and Pb(Sc 1/2 Ta 1/2 )O 3 (PST) are evaluated. Multi-layer ceramic capacitors (MLCCs) with identical structural configurations were fabricated for these three compounds, and their EC properties were characterized by direct measurement using a thermocouple. The EC temperature change of PMN-8PT, 1S-PMN-8PT and PST MLCCs under 20 V μm –1 at room temperature were found to be 1.42 K, 1.54 K, and 3.10 K, respectively. X-ray diffraction and high-resolution transmission electron microscopy data suggests that the high EC performance of PST is related to the ordering of B-site cations (Sc 3+ and Ta 5+ ) with the ordering parameter S = 0.82 and a long coherence length of ~100 nm, such that the sample transitioned from a relaxor ferroelectric to a normal ferroelectric. Furthermore, these results provide pathway towards design of high performance EC materials required for solid state refrigeration and air-conditioning technologies.

36 MATERIALS SCIENCE↗

Multi-metallic conduction cooled superconducting radio-frequency cavity with high thermal stability

Superconducting radio-frequency cavities are commonly used in modern particle accelerators for applied and fundamental research. Such cavities are typically made of high-purity, bulk Nb and with cooling by a liquid helium bath at a temperature of ~2 K. The size, cost and complexity of operating a particle accelerator with a liquid helium refrigerator make the current cavity technology not favorable for use in industrial-type accelerators. We have developed a multi-metallic 1.495 GHz elliptical cavity conductively cooled by a cryocooler. The cavity has a ~2 µm thick layer of Nb 3 Sn on the inner surface, exposed to the rf field, deposited on a ~3 mm thick bulk Nb shell and a bulk Cu shell, of thickness $\geqslant\! 5$ mm deposited on the outer surface by electroplating. A bolt-on Cu plate 1.27 cm thick was used to thermally connect the cavity equator to the second stage of a Gifford-McMahon cryocooler with a nominal capacity of 2 W at 4.2 K. The cavity was tested initially in liquid helium at 4.3 K and reached a peak surface magnetic field of ~36 mT with a quality factor of 2 × 10 9 . The cavity cooled by the cryocooler achieved a peak surface magnetic field of ~29 mT, equivalent to an accelerating gradient of 6.5 MV m –1 . The conduction-cooled cavity could be operated in continuous-wave with as high as 5 W dissipation in the cavity for 1 h without any thermal breakdown, because of the Cu outer layer with high thermal conductivity. This result represents a paradigm shift in the technology of superconducting accelerator cavities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

47 OTHER INSTRUMENTATION↗