Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rejection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Membrane rejection of nitrogen compounds

Rejection characteristics of nitrogen compounds were examined for reverse osmosis, nanofiltration, and low-pressure reverse osmosis membranes. The rejection of nitrogen compounds is explained by integrating experimental results with calculations using the extended Nernst-Planck model coupled with a steric hindrance model. The molecular weight and chemical structure of nitrogen compounds appear to be less important in determining rejection than electrostatic properties. The rejection is greatest when the Donnan potential exceeds 0.05 V or when the ratio of the solute radius to the pore radius is greater than 0.8. The transport of solute in the pore is dominated by diffusion, although convective transport is significant for organic nitrogen compounds. Electromigration contributes negligibly to the overall solute transport in the membrane. Urea, a small organic compound, has lower rejection than ionic compounds such as ammonium, nitrate, and nitrite, indicating the critical role of electrostatic interaction in rejection. This suggests that better treatment efficiency for organic nitrogen compounds can be obtained after ammonification of urea.

NASA Discipline Life Support Systems↗

An analytical solution of the solution-diffusion-electromigration equations reproduces trends in ion rejections during nanofiltration of mixed electrolytes

Here, this paper develops an analytical solution to the equations governing the solution-diffusion-electromigration transport of the ions from two salts that contain a common ion. The analytical expressions, which rely on constant ion permeances, readily enable simple spreadsheet computations of the permeate ion concentrations in nanofiltration (NF). Despite the model simplicity, calculations of ion rejections as a function of transmembrane volume fluxes, feed-solution compositions, and permeance values reproduce experimental trends, with ion permeances as the only adjustable parameters. For example, with solutions containing dissolved MA and M 2 B, when the membrane permeance to B 2– is much lower than the permeances to A – and M + , plots of A – rejection versus transmembrane volume flux show the negative minimum that is often characteristic of NF. Moreover, B 2– rejection increases with increasing MA in the feed solution, reflecting a decreasing electric field in the membrane. The analytical solution also enables spreadsheet computations of electric fields in membrane separation layers and effectively models experimental data for intrinsic rejections as a function of transmembrane volume flow. Interestingly, the model suggests that with sufficiently high permeances of A – (relative to M + ), at certain feed compositions the A – /B 2– selectivity may increase without bound as a function of volume flow. Otherwise, this selectivity does not vary greatly with feed composition and quickly reaches a limit as the volume flow increases. Despite the simplifying approximation of constant ion permeances, using only a few adjustable parameters this model readily reveals trends in NF ion rejections and may help to identify the desired ion permeances or solution compositions for specific separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rejection of malathion by nanofiltration and reverse osmosis membranes exposed to foulant and two clean-in-place procedures

This research tested the treatment efficacy of an Energy Savings Nanofiltration 1 Low Fouling (ESNA 1-LF) nanofiltration (NF) and an Energy Saving Polyamide 2 (ESPA2) reverse osmosis (RO) membrane for removing malathion from water. Both membranes are of composite polyamide construction. The study included measuring malathion rejection using both pristine membranes and membranes exposed to a simulated secondary wastewater effluent foulant before and after two types of clean-in-place procedures. Across all conditions studied, malathion rejection ranged from 84 to 95% for the ESNA1-LF NF membrane and 77 to 94% for the ESPA2 RO membrane. Contact angle measurements were also collected for each membrane exposure condition. While the contact angle measurements indicated changes to the hydrophobicity of the selective layer of the membranes, they did not correlate to changes in the performance of malathion rejection. As expected, it was observed that malathion rejection improved with the introduction of foulant. Also, the clean-in-place procedures helped restore flux while maintaining malathion rejection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar dynamic heat rejection technology. Task 1: System concept development

The results are presented of a concept development study of heat rejection systems for Space Station solar dynamic power systems. The heat rejection concepts are based on recent developments in high thermal transport capacity heat pipe radiators. The thermal performance and weights of each of the heat rejection subsystems is addressed in detail, and critical technologies which require development tests and evaluation for successful demonstration are assessed and identified. Baseline and several alternate heat rejection system configurations and optimum designs are developed for both Brayton and Rankine cycles. The thermal performance, mass properties, assembly requirements, reliability, maintenance requirements and life cycle cost are determined for each configuration. A specific design was then selected for each configuration which represents an optimum design for that configuration. The final recommendations of heat rejection system configuration for either the Brayton or Rankine cycles depend on the priorities established for the evaluation criteria.

Gustafson, Eric↗

Adaptive clutter rejection filters for airborne Doppler weather radar applied to the detection of low altitude windshear

An optimum adaptive clutter rejection filter for use with airborne Doppler weather radar is presented. The radar system is being designed to operate at low-altitudes for the detection of windshear in an airport terminal area where ground clutter returns may mask the weather return. The coefficients of the adaptive clutter rejection filter are obtained using a complex form of a square root normalized recursive least squares lattice estimation algorithm which models the clutter return data as an autoregressive process. The normalized lattice structure implementation of the adaptive modeling process for determining the filter coefficients assures that the resulting coefficients will yield a stable filter and offers possible fixed point implementation. A 10th order FIR clutter rejection filter indexed by geographical location is designed through autoregressive modeling of simulated clutter data. Filtered data, containing simulated dry microburst and clutter return, are analyzed using pulse-pair estimation techniques. To measure the ability of the clutter rejection filters to remove the clutter, results are compared to pulse-pair estimates of windspeed within a simulated dry microburst without clutter. In the filter evaluation process, post-filtered pulse-pair width estimates and power levels are also used to measure the effectiveness of the filters. The results support the use of an adaptive clutter rejection filter for reducing the clutter induced bias in pulse-pair estimates of windspeed.

Keel, Byron M.↗

In-Flight Performance of the TES Loop Heat Pipe Rejection System: Seven Years in Space

The Tropospheric Emission Spectrometer (TES) instrument heat rejection system has been operating in space for nearly 8 years since launched on NASA's EOS Aura Spacecraft. The instrument is an infrared imaging fourier transform spectrometer with spectral coverage of 3.2 to 15.4 microns. The loop heat pipe (LHP) based heat rejection system manages all of the instrument components waste heat including the two mechanical cryocoolers and their drive electronics. Five propylene LHPs collect and transport the instrument waste heat to the near room temperature nadir viewing radiators. During the early months of the mission, ice contamination of the cryogenic surfaces including the focal planes led to increased cryocooler loads and the need for periodic decontamination cycles. Focal plane decontamination cycles require power cycling both cryocoolers which also requires the two cryocooler LHPs to turn off and on during each cycle. To date, the cryocooler LHPs have undergone 24 start-ups in orbit successfully. This paper reports on the TES cryocooler loop heat pipe based heat rejection system performance. After a brief overview of the instrument thermal design, the paper presents detailed data on the highly successful space operation of the loop heat pipes since instrument turn-on in 2004. The data shows that the steady-state and transient operation of the LHPs has not changed since 2004 and shows consistent and predictable performance. The LHP based heat rejection system has provided a nearly constant heat rejection heat sink for all of its equipment which has led to exceptional overall instrument performance with world class science.

allowable flight temperature↗

Longitudinal proteomics analysis in the immediate microenvironment of islet allografts during progression of rejection

The applicability and benefits of pancreatic islet transplantation are limited due to various issues including the need to avoid immune-mediated rejection. In the present study, we used our experimental platform of allogeneic islet transplant in the anterior chamber of the eye (ACE-platform) to longitudinally monitor the progress of rejection in mice and obtain aqueous humor samples representative of the microenvironment of the graft for accurately-timed proteomic analyses. LC-MS/MS-based proteomics performed on such mass-limited samples (~5 μL) identified a total of 1296 proteins. Various analyses revealed distinct protein patterns associated with the mounting of the inflammatory and immune responses and their evolution with the progression of the rejection. Pathway analyses indicated predominant changes in cytotoxic functions, cell movement, and innate and adaptive immune responses. Furthermore, network prediction analyses revealed transition from humoral to cellular immune response and exacerbation of pro-inflammatory signaling. One of the proteins identified by this localized proteomics as a candidate biomarker of islet rejection, Cystatin 3, was further validated by ELISA in the aqueous humor. This study provides (1) experimental evidence demonstrating the feasibility of longitudinal localized proteomics using small aqueous humor samples and (2) proof-of-concept for the discovery of biomarkers of impending immune attack from the immediate local microenvironment of ACE-transplanted islets.

59 BASIC BIOLOGICAL SCIENCES↗

Spectral anomaly methods for aerial detection using KUT nuisance rejection

Aerial detection combines all the challenges of standoff detection with all the difficulties of mobile survey, including large and varying standoff distances and abrupt and significant changes in background. Critical issues for aerial detection include land-water interfaces, rapidly changing KUT backgrounds, and varying down scatter with altitude changes. To address these issues a spectral anomaly method has been adapted to aerial detection. The NSCRAD (Nuisance-Rejection Spectral Comparison Ratio) algorithm was initially developed at PNNL for medium resolution detectors. The algorithm has been used for a range of ground-based detection applications, including ground-based detection, portal monitoring, and OSI applications. The method used in NSCRAD includes both optimized energy windows for detection of threat sources and a nuisance rejection capability. Additionally, the spectral anomaly method was optimized in this work for aerial detection systems to increase the probability of detection of threat sources in aerial search while using the nuisance rejection capability to minimize false alarms from rapidly changing aerial background. The adaptation of NSCRAD for aerial detection includes re-optimization of energy windows, adapting KUT nuisance rejection for aerial backgrounds, development of new methods for background tracking and adjustment of tracking and detection thresholds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated Metabolomics and Proteomics Analyses in the Local Milieu of Islet Allografts in Rejection versus Tolerance

An understanding of the immune mechanisms that lead to rejection versus tolerance of allogeneic pancreatic islet grafts is of paramount importance, as it facilitates the development of innovative methods to improve the transplant outcome. Here, we used our established intraocular islet transplant model to gain novel insight into changes in the local metabolome and proteome within the islet allograft’s immediate microenvironment in association with immune-mediated rejection or tolerance. We performed integrated metabolomics and proteomics analyses in aqueous humor samples representative of the graft’s microenvironment under each transplant outcome. The results showed that several free amino acids, small primary amines, and soluble proteins related to the Warburg effect were upregulated or downregulated in association with either outcome. In general, the observed shifts in the local metabolite and protein profiles in association with rejection were consistent with established pro-inflammatory metabolic pathways and those observed in association with tolerance were immune regulatory. Taken together, the current findings further support the potential of metabolic reprogramming of immune cells towards immune regulation through targeted pharmacological and dietary interventions against specific metabolic pathways that promote the Warburg effect to prevent the rejection of transplanted islets and promote their immune tolerance.

60 APPLIED LIFE SCIENCES↗

An Advanced Thermal Radiator for Global Lunar Heat Rejection

An advanced thermal radiator innovation to provide global heat rejection for Lunar exploration is described in this paper. Infrared background radiation from Lunar terrain can seriously compromise the performance of conventional thermal radiators, especially at lower latitudes. The Apollo missions boiled consumable H2O for heat rejection which would be unsustainable for long duration Lunar exploration where temperatures may exceed 250°F at the equator. The proposed innovation would provide indefinite, sustainable heat rejection for orbiting assets, rovers, landers and habitats over the entire surface of the Moon. The advanced radiator concept introduces a semi-transparent cover-glass to transmit and reflect both incident infrared radiation and solar irradiation to facilitate improved heat rejection. With sponsorship from MSFC Center Innovation Funding (CIF), two advanced radiator concepts were fabricated and evaluated inside the High Intensity Solar Environment Test (HISET) facility thermal vacuum chamber at MSFC. Using custom designed and fabricated test stands in the HISET chamber, the tests simulated both the Lunar terrestrial (inside a crater under full sun) and orbital thermal environments. A conventional radiator was also fabricated and tested under identical conditions for comparison. Test results indicate improved radiator performance (relative to conventional) in the Lunar orbital environment but the advanced radiators did not perform as well as expected in the surface environment. Correlation to thermal math models is presented and future research may consider alternate materials or designs to improve the terrestrial performance.

Thermal Control System↗

Development of CDMS-II Surface Event Rejection Techniques and Their Extensions to Lower Energy Thresholds

The CDMS-II phase of the Cryogenic Dark Matter Search, a dark matter direct-detection experiment, was operated at the Soudan Underground Laboratory from 2003 to 2008. The full payload consisted of 30 ZIP detectors, totaling approximately 1.1 kg of Si and 4.8 kg of Ge, operated at temperatures of 50 mK. The ZIP detectors read out both ionization and phonon pulses from scatters within the crystals; channel segmentation and analysis of pulse timing parameters allowed e ective ducialization of the crystal volumes and background rejection su cient to set world-leading limits at the times of their publications. A full re-analysis of the CDMS-II data was motivated by an improvement in the event reconstruction algorithms which improved the resolution of ionization energy and timing information. The Ge data were re-analyzed using three distinct background-rejection techniques; the Si data from runs 125 - 128 were analyzed for the rst time using the most successful of the techniques from the Ge re-analysis. The results of these analyses prompted a novel \mid-threshold" analysis, wherein energy thresholds were lowered but background rejection using phonon timing information was still maintained. This technique proved to have signi cant discrimination power, maintaining adequate signal acceptance and minimizing background leakage. The primary background for CDMS-II analyses comes from surface events, whose poor ionization collection make them di cult to distinguish from true nuclear recoil events. The novel detector technology of SuperCDMS, the successor to CDMS-II, uses interleaved electrodes to achieve full ionization collection for events occurring at the top and bottom detector surfaces. This, along with dual-sided ionization and phonon instrumentation, allows for excellent ducialization and relegates the surface-event rejection techniques of CDMS-II to a secondary level of background discrimination. Current and future SuperCDMS results hold great promise for mid- to low-mass WIMP-search results.

79 ASTRONOMY AND ASTROPHYSICS↗

Perturbations in the Urinary Exosome in Transplant Rejection

Background: Urine exosomes, vesicles exocytosed into urine by all renal epithelial cell types, occur under normal physiologic and disease states. Exosome contents may mirror disease-specific proteome perturbations in kidney injury. Analysis methodologies for the exosomal fraction of the urinary proteome were developed and for comparing the urinary exosomal fraction versus unfractionated proteome for biomarker discovery. Methods: Urine exosomes were isolated by centrifugal filtration from mid-stream, second morning void, urine samples collected from kidney transplant recipients with and without biopsy matched acute rejection. The proteomes of unfractionated whole urine (Uw) and urine exosomes (Uexo) underwent mass spectrometry-based quantitative proteomics analysis. The proteome data were analyzed for significant differential protein abundances in acute rejection (AR). Results: Identifications of 1018 and 349 proteins, Uw and Uexo fractions, respectively, demonstrated a 279 protein overlap between the two urinary compartments with 25%(70) of overlapping proteins unique to Uexoand represented membrane bound proteins (p=9.31e-7). Of 349 urine exosomal proteins identified in transplant patients 220 were not previously identified in the normal urine exosomal fraction. Uexo proteins (11), functioning in the inflammatory / stress response, were more abundant in patients with biopsy-confirmed acute rejection, 3 of which were exclusive to Uexo. Uexo AR-specific biomarkers (8) were also detected in Uw, but since they were observed at significantly lower abundances in Uw, they were not significant for AR in Uw. Conclusions: A rapid urinary exosome isolation method and quantitative measurement of enriched Uexo proteins was applied. Urine proteins specific to the exosomal fraction were detected either in unfractionated urine (at low abundances) or by Uexo fraction analysis. Perturbed proteins in the exosomal compartment of urine collected from kidney transplant patients were specific to inflammatory responses, and were not observed in the Uexo fraction from normal healthy subjects. Uexo specific protein alterations in renal disease provide potential mechanistic insights and offer a unique panel of sensitive biomarkers for monitoring for acute transplant rejection.

Environmental Molecular Sciences Laboratory↗

Radiator heat rejection options for Shuttle payloads

The paper describes four separate advanced space radiator concepts that have been pursued in an integrated effort to develop multipayload use, low-cost heat rejection systems which can overcome the limitations of current radar systems. These four concepts are the following: (1) a wide heat load range, modularized space radiation system; (2) a heat rejection subsystem designed as a compact self-contained heat rejection module which provides a refrigeration cycle to accomodate a wide variation in payload heat loads and cooling temperature requirements; (3) a lightweight flexible fin radiator system with heat rejection capability; and (4) a radiator which does not require a circulating coolant on the radiator panel with heat pipes and thus particularly applies to very-long-duration free-flying payloads where long life reliability is an overriding design parameter. The Orbiter active thermal control system is briefly described.

Ellis, W. E.↗

Liquid droplet radiators for heat rejection in space

A radiator for heat rejection in space is described which utilizes a stream of liquid droplets to radiate waste heat. The large surface area per mass makes the liquid droplet radiator at least an order of magnitude lighter than tube and fin radiators. Generation and collection of the droplets, as well as heat transfer to the liquid, can be achieved with modest extensions of conventional technology. Low vapor pressure liquids are available which cover a radiating temperature range 250-1000 K with negligible evaporation losses. The droplet radiator may be employed for a wide range of heat rejection applications in space. Three applications - heat rejection for a high temperature Rankine cycle, cooling of photovoltaic cells, and low temperature heat rejection for refrigeration in space illustrate the versatility of the radiator.

Mattick, A. T.↗

Thermal control systems for low-temperature heat rejection on a lunar base

In this report, Rankine-cycle heat pumps and absorption heat pumps (ammonia-water and lithium bromide-water) have been analyzed and optimized for a lunar base cooling load of 100 kW. For the Rankine cycle, a search of several commonly used commercial refrigerants provided R11 and R717 as possible working fluids. Hence, the Rankine-cycle analysis has been performed for both R11 and R717. Two different configurations were considered for the system--one in which the heat pump is directly connected to the rejection loop and another in which a heat exchanger connects the heat pump to the rejection loop. For a marginal increase in mass, the decoupling of the rejection loop and the radiator from the heat pump provides greater reliability of the system and better control. Hence, the decoupled system is the configuration of choice. The optimal TCS mass for a 100 kW cooling load at 270 K was 5940 kg at a radiator temperature of 362 K. R11 was the working fluid in the heat pump, and R717 was the transport fluid in the rejection loop. Two TCS's based on an absorption-cycle heat pump were considered, one with an ammonia-water mixture and the other with a lithium bromide-water mixture as the working fluid. A complete cycle analysis was performed for these systems. The system components were approximated as heat exchangers with no internal pressure drop for the mass estimate. This simple approach underpredicts the mass of the systems, but is a good 'optimistic' first approximation to the TCS mass in the absence of reliable component mass data. The mass estimates of the two systems reveal that, in spite of this optimistic estimate, the absorption heat pumps are not competitive with the Rankine-cycle heat pumps. Future work at the systems level will involve similar analyses for the Brayton- and Stirling-cycle heat pumps. The analyses will also consider the operation of the pump under partial-load conditions. On the component level, a capillary evaporator will be designed, built, and tested in order to investigate its suitability in lunar base TCS and microgravity two-phase applications.

Sridhar, K. R.↗

The embodiment design of the heat rejection system for the portable life support system

The Portable Life Support System (PLSS) provides a suitable environment for the astronaut in the Extravehicular Mobility Unit (EMU), and the heat rejection system controls the thermal conditions in the space suit. The current PLSS sublimates water to the space environment; therefore, the system loses mass. Since additional supplies of fluid must be available on the Space Shuttle, NASA desires a closed heat rejecting system. This document presents the embodiment design for a radiative plate heat rejection system without mass transfer to the space environment. This project will transform the concept variant into a design complete with material selection, dimensions of the system, layouts of the heat rejection system, suggestions for manufacturing, and financial viability.

Stuckwisch, Sue↗

The faint limit of the Hubble Space Telescope faint object spectrograph and rejection of the cosmic-ray background

The faintest object which can be observed with the Hubble Space Telescope (HST) Faint Object Spectrograph (FOS) is set by the detector cosmic-ray background and not by object flux. We use data from Beaver and Lyons to show that 48% of the background counts are from cosmic rays which each generate a near instantaneous burst of two or more counts. Setting the FOS threshold parameter REJLIM = 1, which rejects all frames with more than one count increases the ratio of signal-to-dark counts (S/D) by a factor of 1.94, regardless of the frame time or the object signal, because half of the dark counts which arrive in single counts (from either cosmic-ray bursts or thermal dark current photoemission) are rejected at the same rate as the object signal. But the signal-to-noise ratio (SNR proportional to S/square root of S + D) increases by at most a factor of 1.35, and for realistic parameters and taking into account dead time, we expect a gain in SNR of only 1.18. If a diode has failed and now emits noise, no data at all will be recorded. The chance of this occurring is approximately = 10% , and for this reason we do not recommend the use of REJLIM. The two-point correlation function of dark counts per pixel has strong peaks every four pixels, caused by the action of quarter-stepping on the counts from large bursts. The counts from such bursts spread over at least 80-100 diodes, and we show that such bursts can be rejected during data reduction if the data are recorded in RAPID mode with individual exposures of about 35 seconds. The SNR of the spectrum can also be improved by weighting each exposure by its SNR (a function ofthe mean dark count rate at that time), since dark varies by a factor of 2 around an orbit. These two procedures together increase the SNR by a factor of 1.1.3 (a 28% gain in exposure time) in regions of a spectrum where the object is much fainter than the background. We find that the Ly-alpha and O I sky emission lines give at most 4 (counts/array/s/sq arcsec), and typically half this number. With a small frame time and a small entrance aperture, these counts cause REJLIM = 1 to reject only a few percent of the data. We discuss only the HST FOS blue side detector, but the same ideas apply to any photon counter which records bursts of noise, and the calculations resemble those for the loss of signal due to coincidences in photon counters. In the ideal photon counter the dark counts are readily distinguished from photons. One way to do this is to add detectors which records only dark current, so that every cosmic ray produces more than one count and the instrument can be operated in an anti-coincidence mode.

Tytler, David↗

Demonstration of An Image Rejection Mixer for High Frequency Applications (26-36 GHz)

A new high frequency image-rejection mixer was successfully tested in a 26-36 GHz band receiver. This paper briefly describes the motivation for implementation of an image rejection mixer in a receiver system, the basic operation of an image rejection mixer, and the development and testing of an image rejection mixer for a high frequency, cryogenic receiver system.

Bankston, Cheryl D.↗