Search NASASearch

SEARCH · Search NASA

Results for “Reliability & operability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Hardware-in-the-Loop Experimental Testbed Using Air Conditioners for Grid Balancing

Driven by the need to offset the variability of renewable generation on the grid, development of load control is a highly active field of research. However, practical use of residential loads for grid balancing remains rare, in part due to the cost of communicating with large numbers of small loads and also the limited experimentation done so far to demonstrate reliable operation. To establish a basis for the safe and reliable use of fleets of compressor loads as distributed energy resources, we constructed an experimental testbed in a laboratory, so that load coordination schemes could be tested at extreme conditions. Here, this experimental testbed was used to tune a simulation testbed to which it was then linked, thereby augmenting the effective size of the fleet. Modeling of the system was done both to demonstrate the experimental testbed's behavior and also to understand how to tune the behavior of each load. Implementing this testbed has enabled rapid turnaround of experiments on various load control algorithms, and year-round testing without the constraints and limitations arising in seasonal field tests with real houses. Experimental results show the practical feasibility of an ensemble of small loads contributing to grid balancing.

Air Conditioners

A System Level Comparative Study of SecondarySide Rectifiers for UAV Wireless Power Transfer in High-Altitude Airborne Energy Platforms

Wireless power transfer (WPT) systems for unmanned aerial vehicles (UAVs) must satisfy stringent design requirements to ensure reliable operation under constraints related to efficiency, thermal performance, altitude, weight, and reliability, particularly in airborne and high-altitude environments. Thermal management becomes increasingly challenging at higher altitudes due to reduced air density, while reliability is strongly affected by the number and complexity of active components. The weight and compactness of secondary-side rectifiers directly impact UAV flight endurance and system integration, influencing energy consumption and payload allocation. These factors collectively define the practical feasibility of UAV WPT systems and guide rectifier topology selection. This paper presents a comparative and experimentally validated evaluation framework for secondary-side rectifiers under UAV-specific constraints. Three representative rectifier architectures are analyzed using component-based assessment of weight, thermal behavior, and reliability, together with experimental efficiency measurements obtained from a 1 kW WPT prototype. The results show that the single-switch active rectifier achieves the highest peak efficiency of approximately 93.2% and an overall efficiency of 91%, while also offering advantages in weight and reliability. The findings demonstrate how constraint-oriented analysis, combined with experimental validation, enables informed selection of secondary-side rectifiers for UAV wireless power transfer applications, including emerging airborne and high-altitude platforms.

Asa, Erdem [ORNL] (ORCID:0000000190884812)

Thermocouple and RTD Drift Due to Neutron Irradiation and Temperature for Space Nuclear Applications: A Review

Temperature measurement is a key factor in the safe and reliable operation of nuclear reactors. Thermocouples and resistance temperature detectors (RTDs) are among the most common and reliable tools deployed for temperature measurement, and some are capable of operating in extreme environments such as very high temperature and neutron radiation fields anticipated in nuclear thermal propulsion (NTP) or fission surface power. These devices are known to exhibit drifting behavior in their temperature readings throughout their operational lifetimes. Here, to help select appropriate instrumentation, it is important to identify the factors that influence drift as well as typical behavior in these environments. This work is focused on identifying contributing factors in the performance of thermocouples and RTDs. An extensive literature review is included that discusses several experimental results in different environments. Although individual instrument performance may vary with construction methods, materials selection, and vendors, this review aims to assist in the selection process and identify typical expected behaviors of several devices.

Chesser, Ryan J. [Oak Ridge National Laboratory (O

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]

MegaWatt Mayhem: Grid Operator Challenges Center Loads

This report provides a summary of the challenges faced by United States electricity grid operators in accommodating and anticipating the rapid deployment of large loads, particularly data centers, based on academic literature and industry working groups. The report highlights the unique requirements and operational characteristics of data centers, which differ significantly from traditional industrial loads. Key issues addressed utility planning considerations, with emphasis on the implications for grid operators, impacts to normal operations for grid operators, reliability considerations during periods of grid stress, and resilience considerations for the changing operational paradigms based on data centers. Real-world examples are used to highlight these challenges and the changes that grid operators must address. The findings underscore the necessity for coordinated efforts and innovative solutions from both grid operators and regulatory bodies to ensure the stable integration of large loads into the grid. This report is the first in a series that will explore the challenges of data center deployments based on several key power system perspectives.

24 - POWER TRANSMISSION AND DISTRIBUTION

Characterization of UV optical components for photon detector calibration in liquid argon TPCs

Large liquid argon time projection chambers (LArTPCs)require stable and well-characterized delivery of ultraviolet (UV)light for in situ calibration of photosensors at cryogenictemperatures. This article reports bench-top and cryogenicmeasurements of the optical components used in a UV lightcalibration system, including multi-mode fused-silica fibers,SMA-to-SMA connectors, optical fiber feedthroughs, andlight-diffuser assemblies. Light loss in several fiber types and SMAconnectors was measured across wavelengths from275–970 mm. In addition,light-loss measurements of the tested fibers after severalliquid-nitrogen thermal cycles showed no statistically significantdegradation relative to baseline measurements, and high-rate pulsedexposure (30–90 million pulses from a275 nm LED) likewise showed nomeasurable aging in jacketed fibers. A compact, palm-sized,3D-printed PEEK diffuser housing with stacked UV-grade fused-silicadiffusers yields Lambertian emission and the most uniform angulardistribution. Optical components exhibiting improved UV transmissionwere deployed successfully in multiple DUNE small- and large-scaleprototypes, demonstrating reliable operation of UV light calibrationsystem. These findings inform component selection and calibrationprocedures for achieving reliable, uniform UV light delivery inlarge-scale cryogenic detectors such as DUNE.

Behera, B. [South Dakota Sch. Mines Tech.] (ORCID:

Digital Twin Framework for PIP-II Linac: AI-Driven Multi-Scale Modeling from Ion Source to 800 MeV

The PIP-II linac will enable >1.2 MW beam power for DUNE, requiring unprecedented operational reliability across its warm front-end (RFQ, MEBT) and five distinct SRF sections operating at 162.5/325/650 MHz. We present a comprehensive digital twin framework uniquely combining a fully differentiable fast beam transport code with neural network surrogates trained on high-fidelity PIC simulations, capturing space charge and nonlinear dynamics beyond traditional envelope codes while achieving 10⁴ speedup at <1% accuracy. End-to-end differentiability enables gradient-based optimization across 500+ parameters simultaneously previously impossible with conventional tools while the model incorporates static/dynamic errors and serves as a virtual commissioning platform for diverse hardware integration. The framework facilitates reinforcement learning for pulsed/CW mode transitions, predictive maintenance through anomaly detection, and autonomous tuning algorithm development with real-time execution capability. Validation against physics simulations shows excellent agreement for the front-end, with initial results demonstrating potential for 30% commissioning time reduction and proactive fault mitigation, providing a scalable blueprint for operating next-generation high-intensity accelerators.

Pathak, Abhishek [Fermilab] (ORCID:000000021704208

Digital Twin Framework for PIP-II Linac: AI-Driven Multi-Scale Modeling from Ion Source to 800 MeV

The PIP-II linac will enable >1.2 MW beam power for DUNE, requiring unprecedented operational reliability across its warm front-end (RFQ, MEBT) and five distinct SRF sections operating at 162.5/325/650 MHz. We present a comprehensive digital twin framework uniquely combining a fully differentiable fast beam transport code with neural network surrogates trained on high-fidelity PIC simulations, capturing space charge and nonlinear dynamics beyond traditional envelope codes while achieving 10⁴× speedup at <1% accuracy. End-to-end differentiability enables gradient-based optimization across 500+ parameters simultaneously—previously impossible with conventional tools—while the model incorporates static/dynamic errors and serves as a virtual commissioning platform for diverse hardware integration. The framework facilitates reinforcement learning for pulsed/CW mode transitions, predictive maintenance through anomaly detection, and autonomous tuning algorithm development with real-time execution capability. Validation against physics simulations shows excellent agreement for the front-end, with initial results demonstrating potential for 30% commissioning time reduction and proactive fault mitigation, providing a scalable blueprint for operating next-generation high-intensity accelerators.

Pathak, Abhishek [Fermilab] (ORCID:000000021704208

Data Centers and Digital Assurance Workshop 2 – Prioritizing Digital Assurance Challenges, Session 2

The second session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 10, 2025, focused on prioritizing digital assurance challenges at the intersection of data centers and the electric grid. Building on the foundational concepts introduced in Workshop 1, this session deepened the application of the Threat–Vulnerability–Consequence (TVC) framework and emphasized the urgency of addressing cybersecurity, supply chain integrity, and operational reliability. Participants explored the growing convergence of digital and physical systems, the expanding attack surface due to global supply chain dependencies, and the implications of AI-driven load behavior. Real-world incidents—including the Volt Typhoon campaign and vulnerabilities in Solarman and Deye platforms—were analyzed to illustrate the risks of unpatched systems, insecure APIs, and inadequate vendor oversight. Key themes included architecture and interface weaknesses, governance gaps, and human and procedural shortcomings. The workshop also examined the evolving regulatory landscape, highlighting new federal mandates around Foreign Entity of Concern (FEOC) compliance and large-load reliability standards. Through interactive exercises, stakeholders ranked and mapped digital assurance risks from their respective perspectives—utilities, operators, and vendors—laying the groundwork for mitigation strategies and shared accountability models to be developed in Workshop 3. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION

Novel Organosulfur-Based Electrolytes for Safe Operation of High Voltage Li-ion Batteries over a Wide Operating Temperature

This project addresses the failure of conventional electrolytes and enables high-voltage operation of lithium-ion batteries (LIBs) by developing a novel organosulfur-based electrolyte system. To achieve this goal, we first designed and synthesized new organosulfur solvents that functionalized with strong electron-withdrawing groups such as fluoroalkyl and cyano substituents. Through regio-specific molecular engineering, supported by theoretical calculations, we lowered the highest occupied molecular orbital (HOMO) energy levels of these molecules to increase their anodic stability for high-voltage operation. We then optimized the formulation of the organosulfur-based electrolyte with additives, co-solvents and salts tailored to the newly synthesized solvent molecules. In parallel, we utilized advanced spectroscopic techniques—including in situ FTIR, EIS, and DEMS—to thoroughly elucidate the mechanisms of interaction between the electrolyte and electrode materials. Finally, we evaluated 2 Ah pouch cells under both normal and extreme conditions. Pouch cells with the newly developed electrolyte system demonstrated >90% capacity retention after 500 cycles under 4.5 V operating voltage, >80% capacity retention after 1000 cycles in coin cell level. In addition, the cells exhibited high safety and reliable operation capability over a wide temperature range from −30 °C to +45 °C.

25 ENERGY STORAGE

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)

A Review of Quantum Computing Technologies in Power System Optimization

As modern power grids increasingly integrate variable renewable generation, distributed energy resources, and energy storage systems, classical optimization techniques are facing unprecedented challenges. This review examines the emerging application of quantum computing to overcome these challenges in power system optimization, including optimal power flow (OPF), unit commitment (UC), economic dispatch (ED), and intelligent switching and topology optimization (IS-TO). Recent research has introduced various quantum methodologies—such as gate-based, annealing-based, variational algorithms, and quantum-inspired algorithms—to address the combinatorial complexity inherent in grid reconfiguration and energy management. The review summaries the quantum algorithms, quantum devices and the power system test cases, highlighting hybrid quantum–classical strategies that leverage the complementary strengths of both paradigms. Some quantum advantages have been observed, including theoretical speedup, accurate simulation results, scalable qubit usage, efficient QUBO mapping. In particular, the review emphasizes the importance of integrating quantum optimization techniques with classical control frameworks, these hybrid approaches demonstrate the potential to improve real-time grid management and operational reliability. A significant portion of the analysis is devoted to the practical limitations of current quantum devices. Present-day quantum hardware, operating in the noisy intermediate-scale quantum (NISQ) era, remains highly sensitive to noise and limited in qubit connectivity, which constrains the scale and accuracy of implemented algorithms. The review delves into specific challenges such as the need for qubit-efficient encoding techniques and error mitigation strategies that are critical for handling real-world grid optimization problems. In addition, the work draws attention to the performance discrepancies between theoretical quantum speedups and experimental validations, underscoring the importance of rigorous benchmark studies using representative power grid test cases. In summary, this review highlights both the promise and limitations of quantum computing for power system optimization. It provides a comprehensive overview of the state-of-the-art technologies, categorizes recent advancements in algorithm design, and discusses practical considerations for implementation, and serves as an informative resource on current research. Future research directions include developing robust hybrid frameworks, advancing qubit-efficient formulations, and scaling up experimental demonstrations to confirm the theoretical advantages of quantum methods in large-scale power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION

Reducing Methane Emissions with an Engine Fuel Reformer

Southwest Research Institute (SwRI) designed and demonstrated a compact, plasma-based fuel reformer designed to reduce methane leaks from natural-gas engines used in pipeline compression and industrial power applications. The system uses pulsed electrical discharges to convert a small portion of methane (CH4) into hydrogen (H2) and light hydrocarbons, promoting more complete combustion and reducing unburned methane in the exhaust. The reformer was evaluated through bench-scale testing, high-flow facility testing, and engine-integration testing on representative low-speed and high-speed natural-gas engines. Measured methane-leak reductions ranged from 1 to 27 percent, depending on engine type and operating condition, while reformer energy consumption remained below one percent of total engine output. Design refinements addressed thermal and electrical challenges, resulting in reliable operation with minimal impact on engine control systems. The project achieved all performance objectives within budget and schedule, produced a patentable pulsed-power system design, and established a scalable, energy-efficient pathway for mitigating methane leaks from existing natural-gas engine infrastructure.

03 NATURAL GAS

A Prognostics Framework for Battery Health Monitoring Integrated with Thermal Modeling

Urban Air Mobility (UAM) promises to revolutionize transportation in major cities, offering passenger travel, cargo delivery, and emergency medical services through a network of electric vertical takeoff and landing (eVTOL) aircraft. However, the limited range of current eVTOLs, due to the low specific energy of lithium-ion batteries along with a possibility of thermal runaway conditions poses significant safety concerns, leading to potentially compromising operational safety. To address this critical challenge, researchers are actively evaluating the impact of flight and environmental conditions on onboard lithium-ion battery health. This involves carefully assessing the performance of battery packs under laboratory and operational conditions for developing models to estimate future health using prognostics framework. This study examines the effectiveness of evaluating battery degradation leading to catastrophic failures under varying operational conditions in laboratory. These are captured using physics based models of underlying phenomenons and integrated into the prognostics framework. A fully charged battery undergoes controlled discharge cycles at varying C-rates based on the simulated power draw profile, with current and voltage, temperature data recorded throughout the experiment. The observed data provides valuable insights into how different operating conditions and mission profiles affect battery performance. This information is crucial for developing strategies to optimize battery systems, enhance range, and ultimately ensure the safe and reliable operation of UAM vehicles.

Thermal Modeling

A Prognostics Framework for Battery Health Monitoring Integrated with Thermal Modeling

Urban Air Mobility (UAM) promises to revolutionize transportation in major cities, offering passenger travel, cargo delivery, and emergency medical services through a network of electric vertical takeoff and landing (eVTOL) aircraft. However, the limited range of current eVTOLs, due to the low specific energy of lithium-ion batteries along with a possibility of thermal runaway conditions poses significant safety concerns, leading to potentially compromising operational safety. To address this critical challenge, researchers are actively evaluating the impact of flight and environmental conditions on onboard lithium-ion battery health. This involves carefully assessing the performance of battery packs under laboratory and operational conditions for developing models to estimate future health using prognostics framework. This study examines the effectiveness of evaluating battery degradation leading to catastrophic failures under varying operational conditions in laboratory. These are captured using physics based models of underlying phenomenons and integrated into the prognostics framework. A fully charged battery undergoes controlled discharge cycles at varying C-rates based on the simulated power draw profile, with current and voltage, temperature data recorded throughout the experiment. The observed data provides valuable insights into how different operating conditions and mission profiles affect battery performance. This information is crucial for developing strategies to optimize battery systems, enhance range, and ultimately ensure the safe and reliable operation of UAM vehicles.

Thermal Modeling

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY