Material Aging and Degradation Detection and Remaining Life Assessment for Plant Life Management

One of the major factors that may impact long term operations is structural material degradation, Detecting materials degradation, estimating the remaining useful life (RUL) of the component, and determining approaches to mitigating the degradation are important from the perspective of long term operations. In this study, multiple nondestructive measurement and monitoring methods were evaluated for their ability to assess the material degradation state. Metrics quantifying the level of damage from these measurements were defined, and evaluated for their ability to provide estimates of remaining life of the component. An example of estimating the RUL from nondestructive measurements of material degradation condition is provided.

Bayesian prognostics↗

Life cycle assessment and tempo-spatial optimization of deploying dynamic wireless charging technology for electric cars

Dynamic wireless power transfer (DWPT), or dynamic wireless charging technology, enables charging-while-driving and offers opportunities for eliminating range anxiety, stimulating market penetration of electric vehicles (EVs), and enhancing the sustainability performance of electrified transportation. However, the deployment of wireless charging lanes on highways and urban road networks can be costly and resource-intensive. A life cycle assessment (LCA) is conducted here to compare the sustainability performance of DWPT applied in a network of highways and urban roads for charging electric passenger cars. The assessment compares DWPT to stationary wireless charging and to conventional plug-in charging using a case study of Washtenaw County in Michigan, USA over 20 years. The LCA is based on three key sustainability metrics: costs, greenhouse gas (GHG) emissions, and energy burdens, encompassing not only the use-phase burdens from electricity and fuel, but also the upfront deployment burdens of DWPT infrastructure. A genetic algorithm is applied to optimize the rollout of DWPT infrastructure both spatially and temporally in order to minimize life cycle costs, GHG, and energy burdens: (1) spatial optimization selects road segments to deploy DWPT considering traffic volume, speed, and pavement remaining service life (RSL); (2) temporal optimization determines in which year to deploy DWPT on a particular road segment considering EV market share growth as a function of DWPT coverage rate, future DWPT cost reduction, and charging efficiency improvement. Results indicate that optimal deployment of DWPT electrifying up to about 3% of total roadway lane-miles reduces life cycle GHG emissions and energy by up to 9.0% and 6.8%, respectively, and enables downsizing of the EV battery capacity by up to 48%, compared to the non-DWPT scenarios. Roadside solar panels and storage batteries are essential to significantly reduce life cycle energy and GHG burdens but bring additional costs. Breakeven analysis indicates a breakeven year for solar charging benefits to pay back the DWPT infrastructure burdens can be less than 20 years for GHG and energy burdens but longer than 20 years for costs. A monetization of carbon emissions of at least $250 per metric tonne of CO 2 is required to shift the optimal “pro-cost” deployment to the optimal “pro-GHG” deployment. A roadway segment with volume greater than about 26,000 vehicle counts per day, speed slower than 55 miles per hour (1 mile ≈ 1.609 km), and pavement RSL shorter than 3 years should be given a high priority for early-stage DWPT deployment.

33 ADVANCED PROPULSION SYSTEMS↗

Prognostics and Health Monitoring: Application to Electric Vehicles

As more and more autonomous electric vehicles emerge in our daily operation progressively, a very critical challenge lies in accurate prediction of remaining useful life of the systemssubsystems, specifically the electrical powertrain. In case of electric aircrafts, computing remaining flying time is safety-critical, since an aircraft that runs out of power (battery charge) while in the air will eventually lose control leading to catastrophe. In order to tackle and solve the prediction problem, it is essential to have awareness of the current state and health of the system, especially since it is necessary to perform condition-based predictions. To be able to predict the future state of the system, it is also required to possess knowledge of the current and future operations of the vehicle.Our research approach is to develop a system level health monitoring safety indicator either to the pilotautopilot for the electric vehicles which runs estimation and prediction algorithms to estimate remaining useful life of the vehicle e.g. determine state-of-charge in batteries. Given models of the current and future system behavior, a general approach of model-based prognostics can be employed as a solution to the prediction problem and further for decision making.

Prognostics↗

Investigating the Effect of Damage Progression Model Choice on Prognostics Performance

The success of model-based approaches to systems health management depends largely on the quality of the underlying models. In model-based prognostics, it is especially the quality of the damage progression models, i.e., the models describing how damage evolves as the system operates, that determines the accuracy and precision of remaining useful life predictions. Several common forms of these models are generally assumed in the literature, but are often not supported by physical evidence or physics-based analysis. In this paper, using a centrifugal pump as a case study, we develop different damage progression models. In simulation, we investigate how model changes influence prognostics performance. Results demonstrate that, in some cases, simple damage progression models are sufficient. But, in general, the results show a clear need for damage progression models that are accurate over long time horizons under varied loading conditions.

Daigle, Matthew↗

Analysis of HFIR Dosimetry Experiments Performed in Cycles 400 and 401

The High Flux Isotope Reactor (HFIR) has been in operation at Oak Ridge National Laboratory since 1966. To upgrade and enhance capabilities for neutron science research at the reactor, a larger HB-2 beam tube was installed in April of 2002. To assess, experimentally, the impact of this larger beam tube on radiation damage rates [i.e., displacement-per-atom (dpa) rates] used in vessel life extension studies, dosimetry experiments were performed from April to August 2004 during fuel cycles 400 and 401. This report documents the analysis of the dosimetry experiments and the determination of best-estimate dpa rates. These dpa rates are obtained by performing a least-squares adjustment of calculated neutron and gamma-ray fluxes and the measured responses of radiometric monitors and beryllium helium accumulation fluence monitors. The best-estimate dpa rates provided here will be used to update HFIR pressure vessel life extension studies, which determine the pressure/temperature limits for reactor operation and the HFIR pressure vessel's remaining life. All irradiation parameters given in this report correspond to a reactor power of 85 MW.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On-Orbit Glass Stress Measurement Tool Development

Exposed window surfaces on-orbit are vulnerable to a variety of damage including impacts. These impacts impart stress into the panes and reduce the remaining life of the window. Spacecraft windows are evaluated before and after flight to determine the minimum strength of the glass prior to launch. Currently, no method exists to accurately evaluate the windows on-orbit. An on-orbit optical system is under development to evaluate spacecraft windowpane material for remaining flight life by directly measuring the stress in the glass. This optical system builds on the industry-standard practice of calculating the amount of impact-induced stress through birefringence measurement. In industry, the birefringence is imaged through the pane with a detector and light source on opposite sides. On-orbit, there is only access to one side of the pane. This system has been designed to image birefringence by reflecting the light off the pane to a detector on the same side of the glass. Previous studies have shown a correlation between material stress distribution and the associated K-value. This system is designed to determine low strength areas which can be caused by defects due to impact damage. Glass samples will be imaged and broken in order to correlate impact-induced stress to the fracture strength of the material. Once this correlation is determined, a quantitative assessment of the stress areas in spacecraft windows will occur prior to and during mission operations to reliably determine the overall strength of the glass.

Max J Schneiderman↗

Automatic ultrasonic inspection system for wear determination in calandria tubes of Embalse Nuclear Power Plant

Embalse Nuclear Power Plant (CNE) (CANDU design) is reaching its end of life and due to elapsed operating time the problem of deformation by accelerated creep occurs in the pressure tubes (PT), leading to a possible contact between calandria tubes (CT), concentric to the PT, and some Liquid Injection Shutdown System (LISS) nozzles that pass underneath them. With determination of CT wear, after the predicted contact occurs, the wear rate of the TC could be determined and thus take less conservative measures over the remaining life of the component. This paper presents the development of an ultrasonic technique for measuring wear in CT, with nominal thickness of 1.34 mm. Because the only access is through the interior of PT, to perform this measurement it is necessary to pass through three different interfaces.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Physics-of-Failure Approach to Prognostics

As more and more electric vehicles emerge in our daily operation progressively, a very critical challenge lies in accurate prediction of the electrical components present in the system. In case of electric vehicles, computing remaining battery charge is safety-critical. In order to tackle and solve the prediction problem, it is essential to have awareness of the current state and health of the system, especially since it is necessary to perform condition-based predictions. To be able to predict the future state of the system, it is also required to possess knowledge of the current and future operations of the vehicle. In this presentation our approach to develop a system level health monitoring safety indicator for different electronic components is presented which runs estimation and prediction algorithms to determine state-of-charge and estimate remaining useful life of respective components. Given models of the current and future system behavior, the general approach of model-based prognostics can be employed as a solution to the prediction problem and further for decision making.

Kulkarni, Chetan S.↗

Update on Evaluation of Steam Cycle Upgrades to Improve the Competitiveness of U.S. Coal Power Plants

Under an award issued by the U.S. Department of Energy (DE-FE0031535), the Electric Power Research Institute (EPRI) is leading project to examine the technical and economic feasibility of a series of steam cycle upgrades to the two most prevalent types of U.S. coal power plants (including both subcritical and supercritical cycle configurations). The retrofit upgrade options are focused on evaluating increasing main steam and reheat steam temperatures from 1000°F (538°C) to hotter temperatures, ranging from ultra-supercritical (USC) (i.e., 1100°F or 593°C) to advanced USC (AUSC) conditions (≥1300° or 704°C) while maintaining steam pressures at their original values. By maintaining the original operating steam pressures as well as the original boiler and furnace enclosure envelopes, we aim to minimize the modifications required to the existing power plant, while still providing a significant improvement in heat rate. A unique aspect of this study is that the economic value of the heat rate improvement of each technically feasible option will be determined by detailed modeling of unit dispatch, over the remaining future plant life, in several regional power markets, using EPRI’s US-REGEN model. The capital cost estimates will be compared to the increased revenue estimated by the dispatch modeling to determine the overall economic attractiveness of each upgrade option. The results of this study have the potential to be applicable at up to 80% of the existing U.S. coal-fired power generation fleet. The project team, led by the Electric Power Research Institute, has completed the technical feasibility evaluation, and is currently executing the unit dispatch and capital cost evaluation portions of the work scope. This will describe the motivation for the project, explain the project’s structure and schedule, and provide details on the work scope and preliminary results of the technical feasibility evaluation.

01 COAL, LIGNITE, AND PEAT↗

SSL and LED life prediction and assessment of CCT shift

Solid-state lighting (SSL) products can have a predicted life of 70% lumen output (L70) from 26,000 to 40,000 hours using the LM-80-08 testing standards. Chromaticity shift, correlated color temperature (CCT) and lumen maintenance (LM) will dramatically reduce the nominal life of SSL luminaires. In this work, an off-the-shelf luminaire from Philips (AmbientLED) has been aged in a standard wet hot temperature operating life (WHTOL) of 85% relative humidity and 85°C (85/85) in order to assess reliability of prolonged exposer in a harsh environment. Failure criterion has been derived using the Arrhenius equation from the LM-80-08 standard, as well as the 60W LED Lamp test report from an isothermal environment of 45°C. This is a similar luminaire to the test vehicle used in this research. Data characterization between the two data sets has been carried out to determine the luminaires reliability and life under the 85/85 test conditions. This characterization allows for the determination of poor quality luminaire products in the market place. The distribution properties of the shifting mean values of CCT and LM were incorporated into the Bayesian Linear Regression (BLR) to determine the degradation pattern, in order to predict the remaining useful life (RUL) of the system due to aging before the end-of-life (EoL).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear Ultrasonic Techniques to Monitor Radiation Damage in RPV and Internal Components

The objective of this research is to demonstrate that nonlinear ultrasonics (NLU) can be used to directly and quantitatively measure the remaining life in radiation damaged reactor pressure vessel (RPV) and internal components. Specific damage types to be monitored are irradiation embrittlement and irradiation assisted stress corrosion cracking (IASCC). Our vision is to develop a technique that allows operators to assess damage by making a limited number of NLU measurements in strategically selected critical reactor components during regularly scheduled outages. This measured data can then be used to determine the current condition of these key components, from which remaining useful life can be predicted. Methods to unambiguously characterize radiation related damage in reactor internals and RPVs remain elusive. NLU technology has demonstrated great potential to be used as a material sensor – a sensor that can continuously monitor a material’s damage state. The physical effect being monitored by NLU is the generation of higher harmonic frequencies in an initially monochromatic ultrasonic wave. The degree of nonlinearity is quantified with the acoustic nonlinearity parameter, β, which is an absolute, measurable material constant. Recent research has demonstrated that nonlinear ultrasound can be used to characterize material state and changes in microscale characteristics such as internal stress states, precipitate formation and dislocation densities. Radiation damage reduces the fracture toughness of RPV steels and internals, and can leave them susceptible to IASCC, which may in turn limit the lifetimes of some operating reactors. The ability to characterize radiation damage in the RPV and internals will enable nuclear operators to set operation time thresholds for vessels and prescribe and schedule replacement activities for core internals. Such a capability will allow a more clear definition of reactor safety margins. The research consists of three tasks: (1) materials sensing and monitoring; (2) physics-based materials and damage evolution modeling; and (3) remaining life estimation by integrating sensing, modeling and uncertainty.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On the Language of Reliability: A System Engineer Perspective

In its classical definition, risk is defined by three elements: what can go wrong, what are its consequences, and how likely is it to occur? While this definition makes sense in a regulatory-based framework where for the current fleet of operating light water reactors (LWRs), the risks associated with nuclear power plants typically are characterized in terms of core damage and large early release frequency (LERF), this approach does not provide a useful snapshot of the health of the plant from a broader perspective. This is due to the very narrow context in which the term “risk” typically is defined as nuclear safety aspects that have the potential to impact public health. In this paper, we take the viewpoint of nuclear safety that is reflective of the current fleet of operating LWRs for which core damage frequency and LERF are appropriate metrics. For other advanced reactor designs, other more applicable technology neutral metrics of reactor safety metrics would be specified. A possible alternate path would start by redefining the word risk with a broader meaning that better reflects the needs of a system health and asset management decision-making process. Rather than asking how likely an event could occur (in probabilistic terms), we can ask how far this event is from occurring. Our approach starts by defining and quantifying component and system health in terms of a “distance” between its actual and limiting conditions, i.e., determination of the margin that exists between the current state/condition and the state where the component/system is no longer capable of achieving its intended function. A margin is a measure that is more reflective of the current state or performance of a component, and therefore more closely tied to decisions that are made on an ongoing basis. Further, we will show how, given the data available from plant equipment reliability and monitoring (e.g., pump vibration data) and prognostic (e.g., component remaining useful life estimation) data, a margin can be described and determined for all types of maintenance approaches (e.g., corrective or predictive maintenance). We show how classical reliability models (e.g., fault trees) can be used to quantify the system margin provided component margin values. In the approach described in this paper, the propagation of margin values through classical reliability models are not performed using classical probabilistic calculations applied to sets (as performed in a typical plant probabilistic risk assessment). Instead, we show how it is possible to propagate margin values through Boolean logic gates (i.e., AND and OR operators) through distance-based operations.

97 MATHEMATICS AND COMPUTING↗

Biochemical and genetic studies define the functions of methylthiotransferases in methanogenic and methanotrophic archaea

Methylthiotransferases (MTTases) are radical S-adenosylmethionine (SAM) enzymes that catalyze the addition of a methylthio (-SCH 3 ) group to an unreactive carbon center. These enzymes are responsible for the production of 2-methylthioadenosine (ms 2 A) derivatives found at position A37 of select tRNAs in all domains of life. Additionally, some bacteria contain the RimO MTTase that catalyzes the methylthiolation of the S12 ribosomal protein. Although the functions of MTTases in bacteria and eukaryotes have been established via detailed genetic and biochemical studies, MTTases from the archaeal domain of life are understudied and the substrate specificity determinants of MTTases remain unclear. Here, we report the in vitro enzymatic activities of an MTTase (C4B56_06395) from a thermophilic Ca. Methanophagales anaerobic methanotroph (ANME) as well as the MTTase from a hyperthermophilic methanogen – MJ0867 from Methanocaldococcus jannaschii. Both enzymes catalyze the methylthiolation of N 6 -threonylcarbamoyladenosine (t 6 A) and N 6 -hydroxynorvalylcarbamoyladenosine (hn 6 A) residues to produce 2-methylthio-N 6 -threonylcarbamoyladenosine (ms 2 t 6 A) and 2-methylthio-N 6 -hydroxynorvalylcarbamoyladenosine (ms 2 hn 6 A), respectively. To further assess the function of archaeal MTTases, we analyzed select tRNA modifications in a model methanogen – Methanosarcina acetivorans – and generated a deletion of the MTTase-encoding gene (MA1153). We found that M. acetivorans produces ms 2 hn 6 A in exponential phase of growth, but does not produce ms 2 t 6 A in detectable amounts. Upon deletion of MA1153, the ms 2 A modification was absent, thus confirming the function of MtaB-family MTTases in generating ms 2 hn 6 A modified nucleosides in select tRNAs.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of life for a polyimide-epoxy alternator insulation system

Tests were conducted to predict remaining electrical insulation life of a polyimide epoxy insulated 60 KW, 208 volt homopolar inductor alternator, following completion of 23,130 hours of turbo-alternator endurance tests. The sectioned armature winding of this alternator stator was used as means to evaluate and measure end-life at several aging temperatures for development of an Arrhenius plot. A one-half life rate of 11.3 C was established from these data with a predicted remaining life of 60,000 hours at an armature winding temperature of 248 C and a total life, including endurance test time, of 61,645 hours.

Penn, W. B.↗

Experimental study of A0 Lamb wave tomography

Corrosion damage in inaccessible regions presents a significant challenge to the petrochemical industry, and determining the remaining wall thickness is important to establish the remaining service life. Guided wave tomography is one solution and involves transmitting Lamb waves through the area of interest and using the received signals to reconstruct the remaining wall thickness. This avoids the need to access all points on the surface, making the technique well suited to inspection beneath supports. For this purpose a tomography system for pipe inspections is developed using low frequency A0 Lamb waves that are excited and detected with two arrays of electromagnetic acoustic transducers (EMATs). Two different defect depths are considered with different contrasts relative to the nominal wall thickness and in a first step, the repeatability of the measurements is demonstrated. Due to the limited view array configuration, the maximum depth of the reconstruction underestimates the true depth. In a second experimental study, the influence of a pipe clamp on the thickness reconstruction is considered, representing an inspection problem with restricted access. Preliminary results have shown that the maximum defect depth is further underestimated when compared to the thickness reconstructions without the clamp. However, it is possible to detect the defect underneath the clamp for all conducted experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of Cable Condition Monitoring Technologies to Assess Age-Related Degradation of Industrial Cables Installed in Harsh Environments

The aging of electrical cables has been the subject of substantial research and development (R&D) projects performed by national and international laboratories, universities, and private organizations for many years. This R&D was conducted to develop guidance, equipment, and techniques to support aging management of in-service cables in industrial facilities such as nuclear power plants, research reactors, waste facilities, and fuel fabrication plants. Through these research efforts, condition monitoring technologies have been developed that can determine the severity of age-related degradation that occurs in industrial cables and insulation polymers during service. This paper summarizes the results of aging assessments that were performed for cables installed in two U.S. nuclear power plants, one a pressurized water reactor and one a boiling water reactor. These cables had been in service for over 40 years and during plant operation were exposed to harsh environmental conditions including elevated temperatures and radiation. For these assessments, a comprehensive series of measurements was performed to assess the aged condition of the cables. These cables came from different manufacturers, were manufactured in different years, and were constructed with a variety of jacket and insulation polymers including chloro-sulfonated polyethylene (CSPE), cross-linked polyethylene (XLPE)/cross-linked polyolefin (XLPO), neoprene, and ethylene propylene rubber (EPR). The goal of these assessments was to determine the current aged condition of the cable polymers and provide an estimate of how long the cable insulation materials could remain exposed to their in-service environmental conditions before reaching their end-of-life condition. Both nuclear power plants have received license renewals to extend their operation from 40 to 60 years, and the utilities need objective evidence to show that critical components such as cables will be able to function safely and reliably during the extended operating period. Furthermore, the results of these assessments showed that the cables exhibited different aged conditions depending on the type of polymers they were constructed with and the environment they were exposed to during service. Some of the cables and insulation polymers showed signs of significant age-related degradation and were estimated to have approximately 5 years of remaining service life. Other cables exhibited no signs of significant age-related degradation and were estimated to have 50 years or more of remaining service life. Using the results of these cable aging assessments, plant personnel were able to (1) determine the overall aged condition of cables and insulation polymers using objective test results, (2) identify aged or degraded cables before they caused operability issues, and (3) avoid unnecessary and costly replacement of cables that can continue to operate safely and reliably.

36 MATERIALS SCIENCE↗

A Testbed for Implementing Prognostic Methodologies on Cryogenic Propellant Loading Systems

Prognostics technologies determine the health state of a system and predict its remaining useful life. With this information, operators are able to make maintenance-related decisions, thus effectively streamlining operational and mission-level activities. Experimentation on testbeds representative of critical systems is very useful for the maturation of prognostics technology; precise emulation of actual fault conditions on such a testbed further validates these technologies. In this paper we present the development of a pneumatic valve testbed, initial experimental results and progress towards the maturation and validation of component-level prognostic methods in the context of cryogenic refueling operations. The pneumatic valve testbed allows for the injection of time-varying leaks with specified damage progression profiles in order to emulate common valve faults. The pneumatic valve testbed also contains a battery used to power some pneumatic components, enabling the study of the effects of battery degradation on the operation of the valves.

Prognositcs↗

Prediction of the Creep-Fatigue Lifetime of Alloy 617: An Application of Non-destructive Evaluation and Information Integration

A relatively simple method using the nominal constant average stress information and the creep rupture model is developed to predict the creep-fatigue lifetime of Alloy 617, in terms of time to rupture. The nominal constant average stress is computed using the stress relaxation curve. The predicted time to rupture can be converted to number of cycles to failure using the strain range, the strain rate during each cycle, and the hold time information. The predicted creep-fatigue lifetime is validated against the experimental measurements of the creep-fatigue lifetime collected using conventional laboratory creep-fatigue tests. High temperature creep-fatigue tests of Alloy 617 were conducted in air at 950°C with a tensile hold period of up to 1800s in a cycle at total strain ranges of 0.3% and 0.6%. It was observed that the proposed method is conservative in that the predicted lifetime is less than the experimentally determined values. The approach would be relevant to calculate the remaining useful life to a component like a steam generator that might fail by the creep-fatigue mechanism.